Embedded Module
User Guide
Version 0.1
The Embedded PLCC modem is based on the Differential Code Shift Keying (DCSK)
Technology. This technology in Power Line Carrier (PLCC) communication is well known for its
high immunity to electrical noise persistent in the power line.The PLCC Modem is in the form of a
ready-to-go circuit module, which is capable of transferring data over the power cable at the low
voltage end of the power transformer of a 3-phase/ 4-wire distribution network. A pair of
Embedded PLCC Modems connected on the power line can provide low speed bi-directional data
communication at a baud rate of 9600 bps.
Modulation
○ Differential Code Shift Keying- DCSK
Frequency Band
○ CENELEC : 20-80 kHz outdoor), 95-125 kHz(indoor)
Selectable TTL and RS232C level serial interface to user's data devices.
The following figure highlights some of the key components of the PLCC Board.
The Embedded PLCC modem operates at 5 V. A power supply of 5 V, 1A rating is required and
output should be connected to pin 2 (VCC ) of serial interface connector ( CON J2 on PLCC board).
For details refer Figure 11 and Table 3.
100 mm
AC
R
S
Line Driv er 2
3
M ain
controlle r
2
50
T
mm
T
L
Xformer
SMD Programming Con
Main
Controller
Automatic meter reading (AMR), is the technology used for automatic collection of energy
consumption, diagnostic, and status data for billing and analysis purposes. AMR system gathers
this data and transfer it to central database through networking topology.
Embedded PLCC module is a key component of AMR system employed for energy meter data
collection.
The modules provides bi-directional half-duplex data communication over the mains of any
voltage up to 250 V A.C. and for frequency of 50 or 60 Hz. Data communication of the modules is
transparent to user's data terminals and is protocol independent; as a result, multiple units can be
connected to the mains without affecting the operation of the others. The use of DCSK modulation
technique ensures high noise immunity and reliable data communication. There is no hassle of
building interface circuits. Interface to user's data devices is a simple data-in and data-out serial
link. It has a built-in on board AC coupling circuit, which allows direct and simple connection to
the mains.
In the demo application AMR network is a Tree network structure controlled by a main device
(Master device ) located at level 0 of the network.Network depth can be upto 7 levels and at each
level upto 255 nodes ( Slave devices ) can be connected.Master can send both unicast as well as
broadcast commands in the network.
Master device can be connected to a AMR database server through a serial RS232 port and
nodes ( slave devices) to energy meters.Commands sent from master device will be received by
nodes over power lines and will send data in response to commands received.
Prodigy Labs has developed an architecture for Street Light Control application.In this architecture
there are two modes, one is Base support mode and the other is autonomous mode.
In Base Support mode, the control is through the central server station. Street light control
can be done through this server. In Autonomous mode, the nodes at each of the street light
has its own intelligence to control itself. However, data about its operation will be relayed over to
the central control station.
Control Station
Control station is core intelligence of the whole system. This block is responsible for the street
light switching control when operating in base-support mode. This station
has an user interface through which the control is possible. This control station can be
accessed by the power line concentrator module through GSM/GPRS interface.
The above schematic is a typical dual street light controller node. Each such node can
monitor and control two street lights at a time.
● The sensor and IO control unit can detect ON/OFF status of each streetlight and can also
detect burn out condition of each light as well.
● This has an ambiance light sensor for autonomous operation. With this feature, the street
light can be automatically turned ON if the surrounding light intensity goes below a preset
threshold. Similarly, the light can be turned OFF, if ambiance light detected is higher than
a preset threshold.
● This can measure the amount of energy consumed by each of the lights so as to report to
the central station its energy usage.
The quality and range of a PLCC is dependent on a number of key factors. These
include, but are not limited to, the physical environment/media in which the transmissions take
place.The maximum communication distance depends on various factors like noise and impedance
on the power line at the sender and at the receiver side.
Line driver performance is also related to the network impedance.The following table shows the
peak to peak voltage levels over a range of resistive loads. These values are only to be used as a
guide. These figures are for the CENELEC A band Analogue Front End.
The Embedded PLCC modem has many mechanisms to make the communication more robust.
These
are built-in hardware features such as:
• CRC (Cyclic Redundancy Checksum)
• FEC (Forward Error Correction)
• CSMA/CA (Carrier Sense Multiple Access / Carrier Avoidance)
• LQI (Line Quality Indication)
• 3 different communication modes (Standard Mode, Robust Mode, Extremely
Robust Mode)
The maximum communication distance depends on various factors like noise and impedance
on the power line at the sender and at the receiver side.Line attenuation factor is negligible
(approx 1dB/100m) as compared to the other factors mentioned above.With relatively low noise
level and high line impedance a distance of more than 1000m is easy to achieve.This can be even
expanded when routing technologies of the network layer are utilized.
4-4 Summary
In summary PLCCs are well adapted and robust systems for a range of automation tasks.
The Embedded PLCC module developed by Prodigy Labs Pvt Ltd is well suited for reliable data
communication.
Figure 10 shows the minimal hardware setup required for AMR demo, of course user can add more
than one slave nodes. The requirement for additional PC at slave end can be completely knocked
off by configuring slave nodes to send data in response to pre defined master commands.
In another minimal demo application user can comprehend the functionality simply by running PC
communication program such as Hyperterminal without the need of any emulation software. Just
run the Hyperterminal application at 9600 bps baud rate and send data from the terminal.The
data sent will be received by another PLCC device over power line and can be seen on the
respective PC's Hyperterminal.
The following figure and table below shows the connection and signal name for each connector pin
J10
1-2 MASTER
2-3 SLAVE
Test Application
Connect the Master unit Plug to mains and perform the following steps :
1. Connect the Master Unit serial port connector to the PC with a serial cable ( 1:1 connection
) with a running terminal program as e.g Hyper Terminal.
2. Select the following setting for the terminal application
○ 9600 baud
○ Data bits 8
○ Parity none
○ Stop bits 1
○ Flow control : none
3. Switch ON the master unit.
4. Some information should appear on your PC terminal screen.
5. Similarly connect the two nodes as shown in Fig13 and Fig14 and connect the load like
light,fan etc as load ( load must be less than 6 mA ) , after that switch ON the two nodes.
6. Enter the node id that you want to switch ON/OFF the load, after that next command will
appear on the terminal screen
7. If you enter a 1 the load will ON , if you enter a 0 the load will OFF .
and their applicability in providing optimal solutions. We regard these as a catalyst to establish a
viable and mutually beneficial business relationship with our clients.