Вы находитесь на странице: 1из 2

PROJECT: DESIGN OF THREE-STOREY BUILDING

Location: Hibago, Ocampo, Camarines Sur


Owner:
Type of Occupancy: School Building

DESIGN CRITERIA
I. APPLICABLE CODES/REFERENCES
1. National Structural Code of the Philippines, Sixth Edition (NSCP 2010)
2. National Building Code of the Philippines
3. AISC Load Resistance Factor Design

II. LOADINGS
1. DEAD LOADS
a. Concrete 24.00 kN/m3
b. Topping 1.15 kN/m2
c. Ceiling (acoustical Fiber board) 0.05 kN/m2
d. Electrical works 0.10 kN/m2
e. Machanical Duct Allowance 0.19 kN/m2
f. Parapet weight 0.93 kN/m2

2. LIVE LOADS
2
a. Classroom 1.92 kN/m
b. Corridors 3.83 kN/m2
c. Offices 2.40 kN/m2

3. Wind Load
2
Applicable provisions for Zone 1 2 kN/m
( Wind Velocity = 250 kph )

4. SEISMIC LOAD
Applicable provisions for Zone 4

Soil Profile type: SD


Seismic Source type : A

I 1.00 NSCP Table 208-1


Z 0.40 Seismic Zone Factor NSCP Table 208-3
Nv 1.00 Near Source Factor NSCP Table 208-5
Cv 0.64 Seismic Coefficient NSCP Table 208-8
R 8.50 Numerical Coefficient NSCP Table 208-11
Nₐ 1.00 Near Source Factor NSCP Table 208-4
Cₐ 0.44 Seismic Coefficient NSCP Table 208-7
III. MATERIAL STRENGTH
Structural Steel: Beams, girders, columns
Fy = 36 ksi
Fu = 58 ksi

Structural Steel Bolts


Fu = 120 ksi
Concrete: Base Plate
f'c = 24 kn/m

IV. LOAD COMBINATIONS


a) 1.4DL
b) 1.2DL + 1.6LL
c) 1.2DL + 0.5LL WHERE:
d) 1.2DL + 0.8WL E = ρEh + Ev
e) 1.2DL + 0.5LL + 1.6WL assume ρ=1.1
f) 1.2DL + 0.5LL + 1E Ev = 0.5CaID
g) 1.2DL + 0.5LL - 1E Eh= horizontal component of earthquake force
h) 0.9DL + 1.6WL using lateral force procedure
i) 0.9DL +1E Ev= Vertical Component of earthquake forces
j) 0.9DL - 1E