Вы находитесь на странице: 1из 6

MULTIZONE PA MIX POWER AMPLIFIER

INSTRUCTION MANUAL

NF03933-1.0
INDEX TROUBLE SHOOTING

01 SAFETY RELATED SYMBOLS 1 Symptom Likely Cause What to do


Amplifier not connected Verify that speaker is connected and that the circuit is on
02 WARNING 1 No sound
Power not switched on Switch on power and verify that power Led is on
03 IMPORTANT SAFETY INSTRUCTION 2 Amplifier power cable is faulty *Re-seat the power cable at both ends;
No sound,
amplifier is or improperly connected. *Substitute a known-good power cable
04 INTRODUCTION 3 connected
Blown fuse *Check fuse & replace with same type "spare fuse in holder"
*Check if the signal LED indicators are lit on
05 CONTROL ELEMENTS 3 Signal source (mixer, Amp *Verify that the tape or CD is playing;
instrument) is not sending *Use headphones to verify that the instrument is actually sending
No sound
06 INSTALLATION & CONNECTION 6 Speaker comes on
an audio signal
*Disconnect and re-seat signal cables;
Faulty cables & connections
07 BLOCK DIAGRAM 7 *Replace suspected cable with a known-good cable

No sound with The EON does not supply phantom power. Switch to a dynamic
Microphone requires microphone, use a battery powered microphone (if possible),
08 TECHNICAL SPECIFICATION 8 microphone connected
phantom power use an external phantom power supply for condenser type
to MIC / LINE input
microphones.
09 TROUBLE SHOOTING 9 Signal sounds distorted Excessive input signal, trying *Reduce the output level of the source;
and very loud,LIMIT light to exceed the capabilities of *Turn down the level controls on the speaker;
is lit most of the time the speakers *Use additional EON speakers
*Make sure that the MIC / LINE switch is in the LINE(disengaged)
position;
Lots of hiss in sound, *Reduce the level settings at speaker, Review the Owner's Manual
mixer controls are Improper gain adjustment for your mixer and adjust controls as needed;
at very low settings. or settings *Input sensitivity(gain);
*Channel faders;
*Master faders;
Improper A/Cgounding, *"lift" audio ground by using XLR/F to XLR/M adapter on one end
ground loops *Re-route audio cables away from AC power and lighting cables.
*Use the balanced outputs(if available)of your mixer or source
Excessively long unbalanced equipment to drive your EON speakers.
Hum or Buzz
cable run *Use"DI"(direct injection) box to convert unbalanced equipment
output to a balanced output.
Improper system gain Reduce the INPUT level controls and increase the output level
settings of your source devices.

Microphone are pointed into Move the speakers so they do not point at the microphone's
Speakers feed back the speakers pickup pattern.
and howl when the
microphone volume Incorrect Equalizer settings Locate the feedback frequency and reduce it using the mixer EQ
is turned up or an external equalizer.
Excessive gain Reduce the gain at the mixer and move the microphone closer to
the sound source.

9
TECHNICAL SPECIFICATIONS SAFETY RELATED SYMBOLS Unplug this apparatus during lightning
storms or when unused for long periods
Power Supply: 110-120V~ 60Hz or 220-240V~50/60Hz Selectable of time.
CH1- 4:Mic/Phantom:-50dBV; Line: -10dBV balance External Connection
Inputs Sensitivity: CH5: -10dBV unbalance
The symbol is used to indicate that The external wiring connected to the output
Telephone paging: -10dBV hazardous live terminals requires installation
some hazardous live terminals are
Frequency response: 60-17000Hz(-3dB) involved within this apparatus, even by an instructed person, or the use of ready-
Treble: 10dB at 10KHz under the normal operating conditions. made leads or cords.
Tone control:
Bass: 10dB at 100Hz
The symbol is used in the service Do not Remove any Cover
T.H.D.: 1% documentation to indicate that specific There are maybe some areas with high
Mic. 65dB component shall be only replaced by voltages inside, to reduce the risk of electric
S/N ratio: Line 75dB the component specified in that shock, do not remove any cover if the power
Documentation for safety reasons. supply is connected.
Tel. 65dB
Priority for Mic-1: mute CH2-CH5 Protective grounding terminal. The cover should be removed by the qualified
Outputs impedance: 4 ,8 personnel only.
Alternating current /voltage.
Output constant voltage: 25V,70V,100V No user serviceable parts inside.
Hazardous live terminal .
Power output: RMS120W X 4 (at 4 )
ON: Denotes the apparatus turns on. Fuse
Monitor output: 1W RMS
OFF: Denotes the apparatus turns off, bec- To prevent a fire, make sure to use fuses
Phone output: 1V ( 47ohm) with specified standard (current, voltage,
ause of using the single pole switch, be sure
Line out: 2.0V(BAL) to unplug the AC power to prevent any type). Do not use a different fuse or short
Monitor Line out: 1V( 600 ) electric shock before you proceed your circuit the fuse holder.
5 Gain controls for Ch1-5 service. Before replacing the fuse, turn OFF the
8 Volume controls for Ch1-5, tel. paging, monitor, phone WARNING: Describes precautions that apparatus and disconnected the power
should be observed to prevent the danger source.
4 Master volume control
of injury or death to the user.
5 Trebel controls Protective Grounding
Controls: 5 Bass controls Disposing of this product should Before turning the product ON, make sure that
4 Zone select switch for each channel not be placed in municipal waste it is connected to Ground. This is to prevent the
4 Zone monitor select switch and should be separate collection. risk of electric shock. Never cut internal or
external Ground wires. Likewise, never remove
5 mute controls
CAUTION: Describes precautions that Ground wiring from the Protective Ground
1 AC select switch should be observed to prevent danger of the Terminal.
1Bluetooth PAIR Switch apparatus. Never cut off the internal or external pro-
5VU meters (LED type) tective grounding wire or disconnect the
Indeicate LED: 1 Power indicator
WARNING wiring of protective grounding terminal.
5 Mute indicators Power Supply
The apparatus shall be connected to a mains
1 Bluetooth PAIR indicators Ensure the source voltage matches the socket outlet with a protective earthing
voltage of the power supply before turning connection.
Dimensions:(WxHxD) 483mm(W) x 133mm(H) x 395mm(D)
ON the apparatus.
8 1
Operating Conditions Protect the power cord from being walk- BLOCK DIAGRAM
This apparatus shall not be exposed to ed on or pinched particularly at plugs,
dripping or splashing and that no objects convenience receptacles, and the point
filled with liquids, such as vases, shall be where they exit from the apparatus.
placed on this apparatus.
Cleaning
To reduce the risk of fire or electric shock, When the apparatus needs a cleaning, you
do not expose this apparatus to rain or can blow off dust from the apparatus with
moisture. a blower or clean with rag etc.
Do not use this apparatus near water. Don't use solvents such as benzol, alcohol,
Install in accordance with the manufacture-r's or other fluids with very strong volatility and
instructions. Do not install near any heat flammability for cleaning the apparatus body.
sources such as radiators, heat registers, Clean only with dry cloth.
stoves, or other apparatus (including am-
plifiers) that produce heat. Do not block Servicing
any ventilation openings.
Refer all servicing to qualified personnel. To
No naked flame sources, such as lighted
reduce the risk of electric shock, do not
candles, should be placed on the apparatus.
perform any servicing other than that
contained in the operating instructions unless
IMPORTANT SAFETY INSTRUCTIONS you are qualified to do so .

Read these instructions. Servicing is required when the apparatus has


Follow all instructions. been damaged in any way , such as power
Keep these instructions. supply cord or plug is damaged , liquid has
been spilled or objects have fallen into the
Heed all warnings.
apparatus, the apparatus has been exposed
Only use attachments/accessories spec- to rain or moisture , does not operate
ified by the manufacturer. normally, or has been dropped.
Power Cord and Plug
Do not defeat the safety purpose of the
polarized or grounding type plug.

The mains plug is used as the disconnect device,


the disconnect device shall remain readily
operable.

A polarized plug has two blades with


one wider than the other. A grounding
type plug has two blades and a third
grounding prong. The wide blade or the
third prong are provided for your safety.
If the provided plug does not fit into your
outlet, consult an electrician for replace-
ment of the obsolete outlet.
2 7
INSTALLATION & CONNECTION INTRODUCTION
This unit is a Multizone PA. Mix Power Amplifier for professinal use. It is designed as 3U height
unit, built-in 4 independent power amplifier with RMS 120W. Through setting the zone switch,
4 zones can broadcast independently at the same time. Its main functions are as below:
* 5 independent input channels, among which there are 4 MIC/LINE mixing inputs and 1 LINE
input channel;
* Individual treble, bass and gain control per input channel.
* 4 independent amp output, with 4 OHM & 8 OHM rated impedance output & 25V/70V/100V
rated voltage output in each amp.
* Individual output VU display in each amp.
* Phone out in front panel and monitor out in rear panel, easily operation.
*1 telephone paging input interface.
* Priority broadcast function for telephone input and INPUT 1.
* Built-in fan with intelligent startup function, can reduce energy consumption and for heat
Monitor
Line Out
G +
Monitor
1W 8
+
Priority Tel. Paging

HOT COM GND


Line Mic Line Mic
Line Out Bal./Unbal.
Zone 1 G - + Com 4
Power Amp. Output
8 25V 70V 100V dissipation.
Phantom Phantom
MADE IN CHINA

TEL
Line Out Bal./Unbal.
Zone 2 G - + Com 4
Power Amp. Output
8 25V 70V 100V
It can be used in following electromagnetic environment:residential, commercial and light
Zone Volume
110-120V~ 220-240V~

Ch.3 Ch.1(PRI) industrial, urban outdoors.It is the apparatus intended for rack mounting.
Line Out Bal./Unbal. Power Amp. Output
POWER CONSUMPTION: 1200W
Ch.5
BT Line
Phantom
Line Mic
Phantom
Line Mic
Zone 3 G - + Com 4 8 25V 70V 100V

It can be connected only to a supply with system impedance no more than 0.40ohm.
Line

Use only with a 250V fuse


Line Out Bal./Unbal.
Zone 4 G - + Com 4
Power Amp. Output
8 25V 70V 100V In case necessary, please consult your supply authority, for system impedance information.
Under the EM disturbance, the ratio of signal-noise may be changed above 3dB.
GND 110-120V~60Hz FUSE:T12AL 250V
220-240V~50/60Hz FUSE:T6.3AL 250V
All power amp. output terminals
Ch.4 Ch.2 must connect with Class 2 wiring.

The maximum length of cables: Audio input less than 10m.


For this unit, the peak inrush current is 34.9A.

CONTROL ELEMENTS
FRONT PANEL
1 2 3 4 5 17 11 12 14

CH 1(PRI) CH 2 CH 3 CH 4 CH 5 Professional Multi-Zone Amplifier

GAIN GAIN GAIN GAIN GAIN


ZONE 1 ZONE 2
10 +20 10 +20 10 +20 10 +20 10 +20
PL
VOLUME VOLUME ON
TREBLE TREBLE TREBLE TREBLE TREBLE
10 +10 10 +10 10 +10 10 +10 10 +10

BASS BASS BASS BASS BASS


0 10 0 10
10 +10 10 +10 10 +10 10 +10 10 +10 MON MON OFF

MUTE MUTE MUTE MUTE MUTE PAIR


POWER
ZONE 3 ZONE 4

VOLUME VOLUME
VOL VOL VOL VOL VOL
0 +10 0 +10
0 10 0 10 0 10 0 10 0 10 Headphone Monitor
Volume Volume

Z1 Z2 Z1 Z2 Z1 Z2 Z1 Z2 Z1 Z2
0 10 0 10

Total impedance:4 Ohm Total impedance:8 Ohm Z3 Z4 Z3 Z4 Z3 Z4 Z3 Z4 Z3 Z4 Headphone MON MON

ZONE SELECTOR ZONE SELECTOR ZONE SELECTOR ZONE SELECTOR ZONE SELECTOR

6 7 8 9 16 10 13 15
1 Gain
This knob controls input gain, Turn clockwise & the input will be increased. Turn counter
clockwise and the input will be decreased.
2 Treble
This knob set high frequencies. Used to eliminate noises in high frequencies or enhance
Connecting the speakers with a 25V output Connecting the speakers with a 70V output Connecting the speakers with a 100V output the sound of cymbals, or high harmonics of human voice. The gain range goes from -10dB
to 10dB, with a central frequency of 10kHz.

6 3
19 Power socket
3 Bass 10 Monitor volume control
This knob set low frequencies. Enhances Allows you to connect the supplied power cord.
This knob allows you to set the monitor
male voice &low frequencies from guitars. volume output level. 20 Fuse
The system will sound bigger than what it
is. The gain range goes from -10dB to 11 Zone1volume control This fuse protects the alternating current circuit of the unit, and can be replaced only in case
10dB, with a central frequency of 100Hz. Use this knob to control the volume of the fuse broke.
level of the Zone 1 signal output. 21 Voltage selector
4 Mute
12 LED VU-meter Use this switch to select the voltage according to the zone where you want to install the
Press to mute the signal output of the amplifier.
selected channel. Indicates the overall output signal level.
22 Monitor line out
5 Mute LED 13 Monitor selector This terminal allows you to connect other device, such as amplifier, recorder, etc.
Lights on when mute button was pressed.
Press Monitor, the signal from the 23 1W8Ohm monitor
6 Volume amplifier 1 will connect to monitor Use this terminal to connect small external speakers, which will be powered by an auxiliary
Use this knob to control the volume volume. Press Monitor once again, and power amplifier, offering a 1W of nominal output.
level of the selected channel. If you the connection will be cut. Other three 24 Priority terminal
turn it to right, the volume will raise, buttons are operated in the same way.
if you turn it to left, the volume level When these terminals are in short circuit(e.g. Using an electrical switch), the audio signal
14 PL
will decrease. from channels 2-5 are attenuated.
Lights on when the amplifier is on. 25 TEL paging input
7 Zone Selector
15 On/Off switch Use these terminals to connect an auxiliary signal. The input features of Voice Priority function,
Press the desired buttons to assign a Use this switch to power on / off which overrides all other input signals once, an auxiliary message is sent.
zone. All zones can be operated at the the amplifier. 26 a) TEL Zone
same time. There are 4 dip switches, Move the switch up to select the zone, where you want to listen
16 Pair
8 Phone volume to the signal sent by the phone line.
It can be paired with mobile phones b) TEL volume
Set the volume level of the device tablets or PC Bluetooth adpter to play
plugged to Phone connector. Allows you to set the audio signal output volume from the phone line. When you don't use
stereo audio the phone line, we recommend to use the volume level to 0.
9 Phone with one LED in dicator 27 Line in
The amplifier's audio signal can be sent 17 Power on for 2~3 seconds, the Bluetiooth Allows you to set the audio signal output volume from the phone line. When you don't Use
to the connected headphones. LED flash quickly. this connector to plug an external audio source with a high signal output level, such as AM/
FM tuner, tape deck, CD player, etc. Use sensitive input switches suitable for different
devices. You can connect devices with RCA connectors &non/balanced signals.
28 Mic/Line channel(Mono)
These are channels 1-4 you can connect low impedance-balanced microphones to XLR
REAR PANEL
connector. Into the 1/4" connector you can plug a microphone or line instrument. Do not
17 20 21 22 23 24 27 28 29 30
connect a non-balanced microphone to XLR connectors, otherwise, the amplifier and the
Monitor Monitor Priority Tel. Paging Line Out Bal./Unbal. Power Amp. Output
microphone can be damaged.
Line Out 1W 8
G + + HOT COM GND Zone 1 G - + Com 4 8 25V 70V 100V

MADE IN CHINA
Line
Phantom
Mic Line
Phantom
Mic
29 Phantom switch
110-120V~ 220-240V~
Zone
TEL
Volume
Line Out Bal./Unbal.
Zone 2 G - + Com 4
Power Amp. Output
8 25V 70V 100V If you move the switch to LINE position, you can connect an audio source with a high output
POWER CONSUMPTION: 1200W
Ch.3 Ch.1(PRI)
Line Out Bal./Unbal. Power Amp. Output
level in the channels1-4.
Ch.5

Placing the switch into MIC position, the channels1-4 can be used to connect a dynamic
Zone 3 G - + Com 4 8 25V 70V 100V
Phantom Phantom
BT Line Line Mic Line Mic

Use only with a 250V fuse


Line
Line Out Bal./Unbal.
Zone 4 G - + Com 4
Power Amp. Output
8 25V 70V 100V
microphone with a low impedance.
GND 110-120V~60Hz FUSE:T12AL 250V
220-240V~50/60Hz FUSE:T6.3AL 250V
Finally, if you place the switch to Phantom, the amplifier sends energy to PIN2 and 3.
All power amp. output terminals
Ch.4 Ch.2 must connect with Class 2 wiring.
Being perfect to use this connector to plug condensed microphones. We recommend to use
this switch with the main volume to minimum.
18 19 25 26 30 Balanced/non-balanced line out
18 Fan
These terminals can be used to connect other devices such as amplifier, recorder, etc.
When the temperature is under 50 , the fan stops. But if the temperature is over 50 , the
31 Power amplifier output
fan will start to run and the speed of the fan will be increased until the temperature decreases.
Use these terminals to wire the speakers.
4
5

Вам также может понравиться