Вы находитесь на странице: 1из 1

Project Job no.

Calcs for Start page no./Revision


2
Calcs by Calcs date Checked by Checked date Approved by Approved date
F 20/06/2017

Details for strip


No. Width Tributary Starting Weight of Vertical
strip reinforcement
w idth distance of t w
from left edge
b d (m) t w (m) d s (m) W s (kN) A sv (mm 2 )
Strip 1 0.700 1.200 0.000 15.8 226
Strip 2 0.600 1.600 1.200 14.6 226
Strip 3 0.700 1.200 2.800 17.5 226

Material details
Material properties
Concrete compressive strength; f’ c = 40.00 MPa
Reinforcement yield strength; fy = 500.00 MPa
Modulus of elasticity for steel; E s = E S3600 = 200000.00 MPa
Density of concrete;  c = 24.0 kN/m 3
Modulus of elasticity for concrete; E c = (1 kg / m 3  1.5  0.043  (f’ c)  1 MPa 0.5 = 31975.35 MPa
Compressive stress factor;  2 = max(min(1.0 – 0.003  f’c / 1 MPa, 0.85), 0.67) = 0.850
Stress block depth factor;  = max(min(1.05 – 0.007  f’c / 1 MPa, 0.85), 0.67) = 0.770

Reinforcement details
Singly/doubly reinforced; Singly
Effective depth of reinforcement; d = 75 mm

Strip Vertical reinforcement Horizontal reinforcement


No.

Bar dia No of A sv_prov Bar dia Spacing A sh_prov


bars 2
(mm) (mm ) (mm) S v (mm) (mm 2 )
Strip 1 12 2 226 12 150 3732
Strip 2 12 2 226 12 150 3732
Strip 3 12 2 226 12 150 3732
Loading details
Concentrated vertical loading (Point loads)
No. Dead load Floor live load
P DL xDL e p_DL P LL xLL e p_LL
(kN) (m) (mm) (kN) (m) (mm)
1 150.0 1.500 0 0.0 0.000 0
Lateral loads
Wind load
Design wind speed; V des. = 40 m/sec
Aerodynamic shape factor
External pressure coefficient on windward; C fig_we = 0.70
External pressure coefficient on leeward; C fig_le = -0.75
Possitive internal pressure coefficient; C fig_ps = 0.20

Вам также может понравиться