The following contents are stated on the product and the operation
manual, including usage, precautions against personal harm and
property loss, and the methods of using the product correctly and safely.
After fully understanding the following contents (identifiers and icons),
read the text body and observe the following rules.
Identifier description
Identifier Meaning
Means improper handling may lead to
Warning
personal death or severe injury.
Means improper handling may lead to
Caution
personal injury or property loss.
[Note]: 1. “Harm” means injury, burn and electric shock which need
long-term treatment but need no hospitalization
2. “Property loss” means loss of properties and materials.
Icon description
lcon Meaning
It indicates forbidding. The forbidden subject-matter is
indicated in the icon or by images or characters aside.
It indicates compulsory implementation. The compulsory
subject-matter is indicated in the icon or by images or
characters aside.
Warning
2. System structure diagram
Cloud Servers
PC
CCM15
XYE
LAN F1 F2 E
Laptop
Laptop Router CCM30 Indoor units Max.64
Internet
Optional
Cloud Servers
PC CCM15
XYE
Laptop
Laptop LAN F1 F2 E
Router CCM30
Internet
Optional
Fig.2.2 Outdoor units
Iphone Pad
NOTE
If there’s no XYE communication terminals in the indoor unit PCB,
connect it to XYE communication terminals in the outdoor unit .
III. Installation and con-
figuration instruction
Hardware instruction
Indicator LED Running
light status Instruction
colour
Flashing when 485
485 Green Flash
communication is normal
Flashing when Ethernet
IP Green Flash
connecting is normal
Connect to the
Ethernet
communication
RESET
terminal 485 terminal
Power supply
Fig.3.2
terminal
Instruction
Name Qty. Outline
a. Data converter which equips
WEB/HTTP/TCP/IP functions Data
provides convenience and efficiency converter 1
to users for visiting LAN/WAN and
remote accesses to multi-connected
central air-conditioning system.
Installa-
b. WEB system functions achieve tion
webpage visiting to the multi- operation 1
connected system, including manual
air-conditioner status browsing,
air-conditioner control, and system
settings.
Power
adaptor 1
c. Please follow the installation manual
to operate and assembling according
to the following steps strictly. The Wiring
manufacturer assumes no responsi- 3-terminal
bility or liability for any equipment and 1
damage caused by personal 1
bags of
maloperations. fixed
screws
2.Take the data converter out and power
it on to see if the device is normal
( POWER indicator lights up)
“CMD” path: click “Start menu” - ”operation” - ”CMD” or click “Start ” ”All programs” -
”Accessories” - ”CMD” to enter. Fig.3.5
If it appears “Request timed out” and “Lost=4”, it indicates our network segment
doesn’t have this address. Thus, we can begin “C static address” operations.
If it appears Lost=0”, it indicates our network segment has been occupied. Thus, we
process “B data converter address configuration ”
There is no
such an
address in
this LAN
There’s such
an address
in this LAN
Fig.3.6
IP 192.168.1.201, subnet mask 255.255.255.0 is not in the same segment as IP
172.10.4.120, subnet mask: 255.255.255.0 Input “ipconfig /all”in CMD and press “Enter”
When finishing connecting the device, When entering the “Local Area Connec-
enter into “Network and Internet ”. Click tion Properties”, double click “Internet
“Network and Sharing Connection ”to protocol Version4(TCP/IPv4)” or click
enter “Local Area Connection Proper- “Properties” to enter into Internet
ties” , as shown in the figure : protocol Version4(TCP/IPv4)properties
dialogue. Choose “Use the following IP
address”
Fig.3.10
Fig.3.11
As shown in the figure, choose “Use the following IP address(s)” and input
192.168.1.xxx in “IP address”, xxx ranging from 0 to 255. Don’t input 200; Input
255.255.255.0 in the Default Gateway. Click ”OK” after finishing configuring and log off.
Fig.3.12
When finishing configuring the IP address, open IE browser and input 192.168.1.200
to enter into the WEB page of the data converter, as shown in the figure:
202.104.30.246
NOTE
xxxx
After finishing setting click ”Down-
load settings”. After completing the
settings manually restart. Note:
Please take care of your IP address
and avoiding forgetting.
Fig.3.14
C. Static address settings As shown in the figure, enter into
“Network and Internet ”. Click “Network
After finishing setting the IP address, and Sharing Connection ”to enter
connect the device to a router or “Local Area Connection Properties”
transformer, the connecting way is
shown in the figure:
Fig.3.15
Fig.3.16
When entering the “Local Area Connection Properties”, double click “Internet
protocol Version4(TCP/IPv4)” or click “Properties” to enter into Internet protocol
Version4(TCP/IPv4)properties dialogue. Choose “Use the following IP address”
Fig.3.17
IP address: having found IP
address in step A, input a
different address that don’t
conflict with the host and
device in the same segment ,
such as 10.46.4.75
After finishing
settings, click “OK”
to confirm.
Fig.3.18
NOTE
5. 485 communication wire connection
Connect the device to 485 communication wire after device settings(Refer to the
schematic diagram). Pay attention to A2,B2,E terminals have been connected to XYE
terminals of the central air-conditioner outdoor unit or to F1,F2,E terminals of the
transformer;
Connect to E terminal
Connect to Y or F2 terminal
Connect to X terminal or
F1 terminal
Fig.3.19
6. Enter into the webpage
After connecting to the multi-connected system, it will enter into the project WEB
page. Input http://XXX.XXX.XXX.XXX(Data converter IP address) which is being set
in the previous steps in the browser. Refresh the page to see if it has connected to
the unit.
1. Enter http:// www.imdv.com.cn to apply an ID.
Users use the system through the webpage(http:// www.imdv.com.cn ) or IOS app so
that we should do the following operations
Fig.3.20
First of all, input the address of air-conditioner cloud center, click registration and enter
into the registration page.
In the registration page, input your password and verification code(Note: the code
should be a 6~8-digit number). Submit after confirmation.
Fig.3.21
Fig.3.22
2. Enter into data converter WEB page configuration
Open the browser and input IP address of the device and enter into the webpage,
click “settings” on the top right corner.
Fig.3.23
After inputting your ID and code, click “download settings” to complete the
configuration and go back.
3. Enter into the cloud center page
Fig.3.24
Log in central air-conditioner cloud service center and input your ID number
and password.
IV. Webpage instruction of the Master computer
1. Master computer websites and air-conditioner browser interface instruction.
Fig.4.1
● Refresh: Refresh the webpage
●All Ctrl: can set and control all the indoor units.
●All off: can turn off all the indoor units.
●Schedule: can set the weekly schedule function.
●Rename: can rename the region name.
●Add/Del Region: can add a new region or delete the region.
●Add/Delete AC: can add or delete the indoor unit.
●Error Table: can check the error codes
●Alarms: can check the fault records.
2. Master computer websites and air-conditioner browser interface instruction.
Click the air-conditioner which is need to be controlled to control a single unit.
Click group control to control all the computers together. Shown as the following
picture:
● Mode settings:Cooling,
heating, fan only and
auto mode.
3. Change the password
Users can change the password according to their needs.
Preserve your password properly after changing.
Fig.4.3
NOTE
password is a 6~8 digit number.
4.1 Group control function instructions
Fig.4.4
Input user’s ID, password and tick “As Group User” . Click “Login” to enter into
group user control interface.
Fig.4.5
Click the "Edit" button on the left bottom can set it.
Fig.4.6
Add device or location names in “Name” column as shown above. Input the
corresponding.User’s ID and password in “UserID” and “Pwd” columns. Click
“Apply” to finish adding.
Fig.4.7
Shown as the figure above, click the device name to control air-conditioners in
the region
VI. Android App Instructions
Please log in central air-conditioning cloud server http://imdv.com.cn, and Click the
Android icon shown as the following to download the app.
Fig.7.1
After installing the app input the applied user’s ID and your
password, then click log in to Enter.
Fig.7.2
Air-conditioner zone
Add a new
air-conditioner zone
Group control all-off
Settings
Fig.7.3
Click “Settings” to enter into configuration interface, click “Connection 1”. Input the
user’s ID and password and confirm.
Fig.7.4
After configuration and refreshment, the screen will show the connected air-
conditioner,Click the air-conditioner which needs to be controlled to enter into the
controlling interface,Control on/off status, temperature and mode for a certain
air-conditioner.
Fig.7.5
Version:MD13IU-005DW
202055100964