Table of Contents
I. Safety precautions......................................................................................... 1
II.System introduction of the data converter..................................................... 2
III. Installation and configuration instruction...................................................... 4
IV. Webpage instruction of the Master computer............................................ 24
V. iPhone app instruction.................................................................................31
VI. iPad app instruction....................................................................................34
VII. Android App Instructions...........................................................................38
VII.Technical indicators and requirements...................................................... 43
I. Safety precautions

The following contents are stated on the product and the operation
manual, including usage, precautions against personal harm and
property loss, and the methods of using the product correctly and safely.
After fully understanding the following contents (identifiers and icons),
read the text body and observe the following rules.

 Identifier description
Identifier Meaning
Means improper handling may lead to
Warning
personal death or severe injury.
Means improper handling may lead to
Caution
personal injury or property loss.
[Note]: 1. “Harm” means injury, burn and electric shock which need
long-term treatment but need no hospitalization
2. “Property loss” means loss of properties and materials.

 Icon description
lcon Meaning
It indicates forbidding. The forbidden subject-matter is
indicated in the icon or by images or characters aside.
It indicates compulsory implementation. The compulsory
subject-matter is indicated in the icon or by images or
characters aside.


Warning

Please entrust the distributor or professionals to install


the unit. The installers must have the relevant know-how.
Delegate
Improper installation performed by the user without perm
Warning
arning installation
ission may cause fire, electric,shock, personal injury or w
ater leakage.

Do not spray flammable aerosol to the wire


Forbid
controller directly. Otherwise, fire may occur.
Usage Do not operate with wet hands or let water enter the wire
Forbid
Warning
arning controller. Otherwise, electric shock may occur.

II. System introduction of


the data converter
1. Product Description
The system is mainly made of the
This data converter is an equipment
central air-conditioning system, data
which is based on the TCP/IP protocol
converters, Routing, cloud service and
and RS-485 protocol. It provides TCP/IP
control ends. Users can control the
access interface to the multi-connected
air-conditioning system remotely
central air-conditioner system, and
through terminal devices, such as
realize WEB/HTTP based on the
computers, mobile phones and PAD.
protocols. Users can realize remote
Connect the data converter to Ethernet,
accesses to multi-connected central
and connect it to A bus of the central
air-conditioning system efficiently and
air-conditioning or RS-485 protocol
conveniently through LAN/WAN by
network bus of CCM03 through RS-485
WEB/HTTP/TCP/IP.
protocol interface.


2. System structure diagram

Cloud Servers
PC
CCM15

XYE
LAN F1 F2 E
Laptop
Laptop Router CCM30 Indoor units Max.64
Internet
Optional

Fig.2.1 Schematic diagram of connecting the indoor unit through


Iphone Pad
CCM03 to the central air-conditioning system.

Cloud Servers
PC CCM15

XYE
Laptop
Laptop LAN F1 F2 E
Router CCM30
Internet
Optional
Fig.2.2 Outdoor units

Iphone Pad
NOTE
If there’s no XYE communication terminals in the indoor unit PCB,
connect it to XYE communication terminals in the outdoor unit .


III. Installation and con-
figuration instruction
 Hardware instruction

Fig.3.1 Structure dimension drawing


Indicator LED Running
light status Instruction
colour
Flashing when 485
485 Green Flash
communication is normal
Flashing when Ethernet
IP Green Flash
connecting is normal

Yellow Constantly Constantly light after


POWER
light powering on

Status indicator light

Connect to the
Ethernet
communication
RESET
terminal 485 terminal
Power supply
Fig.3.2
terminal


 Instruction
Name Qty. Outline
a. Data converter which equips
WEB/HTTP/TCP/IP functions Data
provides convenience and efficiency converter 1
to users for visiting LAN/WAN and
remote accesses to multi-connected
central air-conditioning system.
Installa-
b. WEB system functions achieve tion
webpage visiting to the multi- operation 1
connected system, including manual
air-conditioner status browsing,
air-conditioner control, and system
settings.
Power
adaptor 1
c. Please follow the installation manual
to operate and assembling according
to the following steps strictly. The Wiring
manufacturer assumes no responsi- 3-terminal
bility or liability for any equipment and 1
damage caused by personal 1
bags of
maloperations. fixed
screws

1. Unpack the packing box to see if


the accessories are all in readiness.
Data converter is shown as the
following figure:


2.Take the data converter out and power
it on to see if the device is normal
( POWER indicator lights up)

POWER indicator lights up


Fig.3.3 Fig.3.4
3. Data converter installation
precautions Debugging as the following steps
a. Don’t install it in the place where
flammable gas leaks easily.Once A. Device address instruction
flammable gas leakage occurs and
stagnate around the device, it may Initial address of the data converter is
result in fire. 192.168.1.200. To avoid address
b. Keep the device from heating conflict, check if there’s the address in
element as far as possible. LAN before accessing the device.
c. Don’t install it in the place that is too Open CMD interface and input “ping
dirty or humid. 192.168.1.200”.
4. Access the master computer and
debugging

Use cables to connect the data


converter to a router or a transformer
and connect the router or the
transformer to a PC. Electrify the
adaptor and debug after it can be
electrified normally.IP address of the
data converter is http//192.168.1.200.


“CMD” path: click “Start menu” - ”operation” - ”CMD” or click “Start ” ”All programs” -
”Accessories” - ”CMD” to enter. Fig.3.5

If it appears “Request timed out” and “Lost=4”, it indicates our network segment
doesn’t have this address. Thus, we can begin “C static address” operations.
If it appears Lost=0”, it indicates our network segment has been occupied. Thus, we
process “B data converter address configuration ”

There is no
such an
address in
this LAN

There’s such
an address
in this LAN

Fig.3.6


IP 192.168.1.201, subnet mask 255.255.255.0 is not in the same segment as IP
172.10.4.120, subnet mask: 255.255.255.0 Input “ipconfig /all”in CMD and press “Enter”

Check IP address informa-


tion here in this LAN

For detailed information about


the IP address segments, please
refer to the related information.
Due to the limited space, we
don’t do Detailed explain. Fig.3.7
We can see the “Default
Gateway” is our default
gateway: 10.46.4.1,
“Subnet Mask” is the
subnet mask:
255.255.255.0. Thus, we
need to change our device
IP address to this
segment’s IP address,
such as:
Change IP address to
10.46.4.100ˈ
Change Subnet Mask to:
Fig.3.8
255.255.255.0

Connect the data converter to the transformer or router to debug after we confirm the
Default Gateway and Subnet Mask in the LAN

B. Configure the data transformer IP address


If IP address segment of the device is the same as that of the PC, this configuration
is unnecessary then. Directly enter into C step: static IP address configuration.
Otherwise the IP address needs to be changed.
Firstly, connect the device to a computer. There’s no need to go through the
transformer or router. If there’s one, please unplug the cable to the computer firstly
,and then connecting as the figure shown below (cross line).Connect the device with
PC by cross line only.

cross line Fig.3.9


When finishing connecting the device, When entering the “Local Area Connec-
enter into “Network and Internet ”. Click tion Properties”, double click “Internet
“Network and Sharing Connection ”to protocol Version4(TCP/IPv4)” or click
enter “Local Area Connection Proper- “Properties” to enter into Internet
ties” , as shown in the figure : protocol Version4(TCP/IPv4)properties
dialogue. Choose “Use the following IP
address”

Fig.3.10

Fig.3.11

As shown in the figure, choose “Use the following IP address(s)” and input
192.168.1.xxx in “IP address”, xxx ranging from 0 to 255. Don’t input 200; Input
255.255.255.0 in the Default Gateway. Click ”OK” after finishing configuring and log off.

Fig.3.12


When finishing configuring the IP address, open IE browser and input 192.168.1.200
to enter into the WEB page of the data converter, as shown in the figure:

Click the setting page on the top right Fig.3.13


corner, do page settings and change
the IP address.

In the example of A step, we see the


Default Gateway: 10.46.4.1, Subnet DATA
Mask: 255.255.255.0, thus we need to with CCM03-0
change the IP address of this segment
10.46.4.100 3562
as IP˖10.46.4.100Subnet˖
255.255.255.0
255.255.255.0
10.46.4.100

202.104.30.246
NOTE
xxxx
After finishing setting click ”Down-
load settings”. After completing the
settings manually restart. Note:
Please take care of your IP address
and avoiding forgetting.
Fig.3.14

C. Static address settings As shown in the figure, enter into
“Network and Internet ”. Click “Network
After finishing setting the IP address, and Sharing Connection ”to enter
connect the device to a router or “Local Area Connection Properties”
transformer, the connecting way is
shown in the figure:

Fig.3.15

Fig.3.16


When entering the “Local Area Connection Properties”, double click “Internet
protocol Version4(TCP/IPv4)” or click “Properties” to enter into Internet protocol
Version4(TCP/IPv4)properties dialogue. Choose “Use the following IP address”

Fig.3.17


IP address: having found IP
address in step A, input a
different address that don’t
conflict with the host and
device in the same segment ,
such as 10.46.4.75

Subnet mask: : having found


Subnet Mask address in step
A, then input Subnet Mask:
255.255.255.0

Input the Default Gateway


address which has been
found in Step A.

After finishing
settings, click “OK”
to confirm.

Fig.3.18

NOTE

Note: set the IP address according


to the situation. It’s only an example
above .


5. 485 communication wire connection
Connect the device to 485 communication wire after device settings(Refer to the
schematic diagram). Pay attention to A2,B2,E terminals have been connected to XYE
terminals of the central air-conditioner outdoor unit or to F1,F2,E terminals of the
transformer;

Connect to E terminal
Connect to Y or F2 terminal
Connect to X terminal or
F1 terminal

Fig.3.19


6. Enter into the webpage
After connecting to the multi-connected system, it will enter into the project WEB
page. Input http://XXX.XXX.XXX.XXX(Data converter IP address) which is being set
in the previous steps in the browser. Refresh the page to see if it has connected to
the unit.

 WEB page configuration


● Webpage and computer configuration requirements.
● WEB browsers: IE 6.0 above, Safari 4.0 above, Chrome 18.0 above, UC 8.4
above.
● Operation systems: Windows/Linux/Unix/Mac/iOS etc.
● Operation platforms: PC/Notebook/PAD/Smart phone (iPhone, Android etc).
● Input the URL address of our cloud server(http:// www.imdv.com.cn) to log in our
cloud server. The air-conditioner will be monitored after logging in.
● Take Windows XP and IE 6.0 as an example to do interface instruction. Operations
are the same in other platforms and browsers, but displays may be different. Due
to compatible problems in explaining HTML and JAVASCRIPT by browsers, we
suggest to use a higher browser version to solve some compatible problems.


1. Enter http:// www.imdv.com.cn to apply an ID.

Users use the system through the webpage(http:// www.imdv.com.cn ) or IOS app so
that we should do the following operations

Fig.3.20


First of all, input the address of air-conditioner cloud center, click registration and enter
into the registration page.

In the registration page, input your password and verification code(Note: the code
should be a 6~8-digit number). Submit after confirmation.

Fig.3.21


Fig.3.22

Registration successfully, please remember your personal information. It’s a


personal ID, please take care of it.


2. Enter into data converter WEB page configuration
Open the browser and input IP address of the device and enter into the webpage,
click “settings” on the top right corner.

User defined name


Corresponding CCM03
Modbus address
Data module IP address Subnet mask
Cloud Server IP
Default gateway
Input your ID
and word

Fig.3.23

After inputting your ID and code, click “download settings” to complete the
configuration and go back.


3. Enter into the cloud center page

Input "http://www.imdv.com.cn"on the browser, it will login the cloud services


webpage and enter the following dialog:

Fig.3.24

Log in central air-conditioner cloud service center and input your ID number
and password.


IV. Webpage instruction of the Master computer
1. Master computer websites and air-conditioner browser interface instruction.

Fig.4.1
● Refresh: Refresh the webpage
●All Ctrl: can set and control all the indoor units.
●All off: can turn off all the indoor units.
●Schedule: can set the weekly schedule function.
●Rename: can rename the region name.
●Add/Del Region: can add a new region or delete the region.
●Add/Delete AC: can add or delete the indoor unit.
●Error Table: can check the error codes
●Alarms: can check the fault records.

2. Master computer websites and air-conditioner browser interface instruction.
Click the air-conditioner which is need to be controlled to control a single unit.
Click group control to control all the computers together. Shown as the following
picture:

● Mode settings:Cooling,
heating, fan only and
auto mode.

● Air flow speed settings:


high speed, middle
speed and low speed.

● Temp. settings: set temp.


from 17 °C to 30°C
according to your need.

● Back: go back to the


previous page.

● Lock: can lock the


mode,setting tempera-
ture, fan speed and
remote controller.
Fig.4.2


3. Change the password
Users can change the password according to their needs.
Preserve your password properly after changing.

Fig.4.3

NOTE
password is a 6~8 digit number.


4.1 Group control function instructions

Fig.4.4

Input user’s ID, password and tick “As Group User” . Click “Login” to enter into
group user control interface.


Fig.4.5

Click the "Edit" button on the left bottom can set it.


Fig.4.6
Add device or location names in “Name” column as shown above. Input the
corresponding.User’s ID and password in “UserID” and “Pwd” columns. Click
“Apply” to finish adding.


Fig.4.7

Shown as the figure above, click the device name to control air-conditioners in
the region



VI. Android App Instructions
Please log in central air-conditioning cloud server http://imdv.com.cn, and Click the
Android icon shown as the following to download the app.

Fig.7.1


After installing the app input the applied user’s ID and your
password, then click log in to Enter.

Fig.7.2


Air-conditioner zone

Add a new
air-conditioner zone
Group control all-off

Group control all on

Settings

Fig.7.3


Click “Settings” to enter into configuration interface, click “Connection 1”. Input the
user’s ID and password and confirm.

Fig.7.4


After configuration and refreshment, the screen will show the connected air-
conditioner,Click the air-conditioner which needs to be controlled to enter into the
controlling interface,Control on/off status, temperature and mode for a certain
air-conditioner.

Fig.7.5


Version:MD13IU-005DW

202055100964