Comment Resolution Sheet (RT)

Doc No. Project Title Date

HITECH-1003-STS-PDO-WSV18064-RT-01-02 LEKHWAIR WATER SYSTEM IMPROVEMENT PROJECT 05.03.2019

Cl. No. Client's Comment Comment Status STS/HITECH Response Client Comment/Acceptance

Gen. Add - cover sheet with document number Incorporated.

Add - Contractor / Manufacturer shall have a dedicated film interpreter Kindly note, RT activity performed by STS appointed sub-
3.3 who is independent of NDE contractor involved in inspection (Testing) & Incorporated contractor on behalf of STS. STS QC inspector shall review the Refer below Client comment.
shall be approved by the Company. RT films & sign the report.

Please refer the SP1173. Extract and our compliance below.

STS as a manufacturer appointed Hitech as a Sub-contractor for


RT & RTFI. RT crew will perform RT at STS shop. RTFI is different
person who will only review films and endorse the report.

Approval of RTFI - NDE personal is not mandatory as per


Refer response. specification and RTFI approval requirement specifically not
mentioned in MR. however we will provide RTFI - Hitech CV for
review.

Please note SP1173 specification asks for independent person


not Independent party. Hence, Manufacturer RTFI requirement is
not in a part of STS scope. if it is mandatoryly required it shall be
considered as additional scope upon agreement with cost and
delivery impact.