Вы находитесь на странице: 1из 3

Integrated Membranes Solutions Design Software, 2017

Created on: 30-03-2019 01:44:53

Basic Design
Project name Page : 1/3
Calculated by Nadim Permeate flow/train 12.00 m3/h
HP Pump flow 20.00 m3/h Raw water flow/train 20.00 m3/h
Feed pressure 14.9 bar Permeate recovery 60.00 %
Feed temperature 25.0 °C(77.0°F) Element age 3.0 years
Feed water pH 7.00 Flux decline %, per year 5.0
Chem dose, mg/l, - None Fouling factor 0.86
Specific energy 0.86 kwh/m3 SP increase, per year 7.0 %
Pass NDP 10.2 bar Inter-stage pipe loss 0.2 bar
Average flux rate 26.9 lmh
Feed type Brackish Well Non-Fouling

Pass - Perm. Flow / Vessel Flux DP Flux Beta Stagewise Pressure Perm. Element Element PV# x
Stage Flow Feed Conc Max Perm. Boost Conc TDS Type Quantity Elem #
m3/h m3/h m3/h lmh bar lmh bar bar bar mg/l
1-1 8.9 10 5.6 29.9 0.6 33.1 1.16 0 0 14.3 45.5 CPA3 8 2 x 4M
1-2 3.1 11.1 8.0 20.9 0.8 23.8 1.1 0 0 13.4 115.7 CPA3 4 1 x 4M
Permeate
Ion (mg/l) Raw Water Feed Water Water Concentrate 1 Concentrate 2
Hardness, as CaCO3 0.00 0.00 0.000 0.0 0.0
Ca 0.00 0.00 0.000 0.0 0.0
Mg 0.00 0.00 0.000 0.0 0.0
Na 1377.25 1377.25 25.078 2465.5 3408.8
K 0.00 0.00 0.000 0.0 0.0
NH4 0.00 0.00 0.000 0.0 0.0
Ba 0.000 0.000 0.000 0.0 0.0
Sr 0.000 0.000 0.000 0.0 0.0
H 0.00 0.00 0.003 0.0 0.0
CO3 0.00 0.00 0.000 0.0 0.0
HCO3 0.10 0.10 0.003 0.2 0.2
SO4 0.00 0.00 0.000 0.0 0.0
Cl 2122.75 2122.75 38.651 3800.0 5254.0
F 0.00 0.00 0.000 0.0 0.0
NO3 0.00 0.00 0.000 0.0 0.0
PO4 0.00 0.00 0.000 0.0 0.0
OH 0.00 0.00 0.000 0.0 0.0
SiO2 0.00 0.00 0.000 0.0 0.0
B 0.00 0.00 0.000 0.0 0.0
CO2 0.02 0.02 0.02 0.02 0.02
TDS 3500.10 3500.10 63.74 6265.64 8662.98
pH 7.00 7.00 5.50 7.12 7.24

Saturations Raw Water Feed Water Concentrate Limits


CaSO4 / ksp * 100, % 0 0 0 400
SrSO4 / ksp * 100, % 0 0 0 1200
BaSO4 / ksp * 100, % 0 0 0 10000
SiO2 saturation, % 0 0 0 140
CaF2 / ksp * 100, % 0 0 0 50000
Ca3(PO4)2 saturation index 0.0 0.0 0.0 2.4
CCPP, mg/l 0.00 0.00 0.00
Langelier saturation index 0.00 0.00 0.00 2.5
Ionic strength 0.06 0.06 0.15
Osmotic pressure, bar 2.8 2.8 6.9

Product performance calculations are based on nominal element performance when operated on a feed water of acceptable quality. The results shown on the printouts produced by this program are
estimates of product performance. No guarantee of product or system performance is expressed or implied unless provided in a separate warranty statement signed by an authorized Hydranautics
representative. Calculations for chemical consumption are provided for convenience and are based on various assumptions concerning water quality and composition. As the actual amount of chemical
needed for pH adjustment is feedwater dependent and not membrane dependent, Hydranautics does not warrant chemical consumption. If a product or system warranty is required, please contact your
Hydranautics representative. Non-standard or extended warranties may result in different pricing than previously quoted. Version : 1.218.78 %

Email : imsd-support@hydranauticsprojections.net
Integrated Membranes Solutions Design Software, 2017

Created on: 30-03-2019 01:44:53

Basic Design
Project name Page : 2/3
Calculated by Nadim Permeate flow/train 12.00 m3/h
HP Pump flow 20.00 m3/h Raw water flow/train 20.00 m3/h
Feed pressure 14.9 bar Permeate recovery 60.00 %
Feed temperature 25.0 °C(77.0°F) Element age 3.0 years
Feed water pH 7.00 Flux decline %, per year 5.0
Chem dose, mg/l, - None Fouling factor 0.86
Specific energy 0.86 kwh/m3 SP increase, per year 7.0 %
Pass NDP 10.2 bar Inter-stage pipe loss 0.2 bar
Average flux rate 26.9 lmh
Feed type Brackish Well Non-Fouling

Pass - Perm. Flow / Vessel Flux DP Flux Beta Stagewise Pressure Perm. Element Element PV# x
Elem #
Max
Stage Flow Feed Conc Perm. Boost Conc TDS Type Quantity
m3/h m3/h m3/h lmh bar lmh bar bar bar mg/l
1-1 8.9 10 5.6 29.9 0.6 33.1 1.16 0 0 14.3 45.5 CPA3 8 2 x 4M
1-2 3.1 11.1 8.0 20.9 0.8 23.8 1.1 0 0 13.4 115.7 CPA3 4 1 x 4M
Permeat Permeate
Pass - Element Feed Pressure Conc NDP e Water Water Beta Permeate (Passwise cumulative)
Stage no. Pressure Drop Osmo. Flow Flux TDS Ca Mg Na Cl
bar bar bar bar m3/h lmh
1-1 1 14.9 0.19 3.2 11.9 1.2 33.1 1.12 28.3 0 0 11.141 17.17
1-1 2 14.7 0.16 3.6 11.3 1.2 31.1 1.13 32.7 0 0 12.858 19.816
1-1 3 14.6 0.13 4.2 10.6 1.1 29 1.15 38.2 0 0 15.042 23.183
1-1 4 14.4 0.1 5 9.8 1 26.7 1.16 45.5 0 0 17.894 27.578

1-2 1 14.1 0.23 5.4 8.9 0.9 23.8 1.08 49.5 0 0 19.471 30.01
1-2 2 13.9 0.2 5.8 8.2 0.8 21.9 1.1 53.8 0 0 21.175 32.635
1-2 3 13.7 0.18 6.3 7.6 0.7 20 1.1 58.5 0 0 23.031 35.496
1-2 4 13.5 0.16 6.9 6.9 0.7 18.2 1.08 63.7 0 0 25.062 38.626

Product performance calculations are based on nominal element performance when operated on a feed water of acceptable quality. The results shown on the printouts produced by this program are
estimates of product performance. No guarantee of product or system performance is expressed or implied unless provided in a separate warranty statement signed by an authorized Hydranautics
representative. Calculations for chemical consumption are provided for convenience and are based on various assumptions concerning water quality and composition. As the actual amount of chemical
needed for pH adjustment is feedwater dependent and not membrane dependent, Hydranautics does not warrant chemical consumption. If a product or system warranty is required, please contact your
Hydranautics representative. Non-standard or extended warranties may result in different pricing than previously quoted. Version : 1.218.78 %

Email : imsd-support@hydranauticsprojections.net
Integrated Membranes Solutions Design Software, 2017

Created on: 30-03-2019 01:44:53

Basic Design
Project name Page : 3/3
Temperature : 25.0 °C Element age, P1 : 3.0 years

Stream No. Flow (m3/h) Pressure (bar) TDS (mg/l) pH Econd (µs/cm)
1 20.0 0 3500 7.00 6316
2 20.0 14.9 3500 7.00 6316
3 11.1 14.3 6266 7.12 10766
4 7.99 13.4 8663 7.24 14521
5 8.89 0 45.5 5.35 99.9
6 3.12 0 116 5.75 251
7 12.0 0 63.7 5.50 139

Product performance calculations are based on nominal element performance when operated on a feed water of acceptable quality. The results shown on the printouts produced by this program are
estimates of product performance. No guarantee of product or system performance is expressed or implied unless provided in a separate warranty statement signed by an authorized Hydranautics
representative. Calculations for chemical consumption are provided for convenience and are based on various assumptions concerning water quality and composition. As the actual amount of chemical
needed for pH adjustment is feedwater dependent and not membrane dependent, Hydranautics does not warrant chemical consumption. If a product or system warranty is required, please contact your
Hydranautics representative. Non-standard or extended warranties may result in different pricing than previously quoted. Version : 1.218.78 %

Email : imsd-support@hydranauticsprojections.net