Вы находитесь на странице: 1из 27

IWCF Surface Well Control

Exercise No. 11
API (Field Units)

SURFACE WELL CONTROL EXERCISE NO. 11

EQUIPMENT

Name: ______________________________________ Date: ___________________

1. The gauges on the Driller’s remote BOP control panel are used to observe the
status of the surface BOP control unit while drilling.

Figure S11-001 shows a set of gauge readings with a change that is occurring
(the BOP has not been operated and the electrically driven pump is not running).

Figure S11-001

What are the possible reasons for the low accumulator pressure reading?
(Select TWO Answers)

a) There is a faulty electric pressure switch.

b) The manifold regular bypass valve is leaking.

c) There is a hydraulic leak in the system.

d) The accumulator pre-charge pressure has been set too low.

Revised February 2010 1


IWCF Surface Well Control
Exercise No. 11
API (Field) Units

2. On the central hydraulic control unit (Koomey Unit) for the BOP there is a
unit/remote switch. The purpose of this device is?

a) To allow the Driller to adjust the cut in / cut out pressure settings on the air
and electric charge pumps for the accumulator unit from the Driller’s remote control
panel for the BOP.
b) To allow the Driller to adjust the opening / closing pressure of the ram preventers
from the Driller’s remote control panel for the BOP.
c) To allow the Driller to adjust pressures of the annular preventer from the Driller’s
remote control panel for the BOP.
d) To allow the Driller to adjust the accumulator pressure from the Driller’s remote
control panel for the BOP.

3. Using the BOP configuration illustrated in Figure S11-002 below answer the
following six questions by answering YES or NO.
(The questions are based on whether the operations can be physically
performed and do not represent the field practice or operating procedure of any
company).

Figure S11-002

3a. With drill pipe in the hole, is it possible to shut the well in under pressure and
repair the side outlets on the drilling spool?

a) YES
b) NO

Revised February 2010 2


IWCF Surface Well Control
Exercise No. 11
API (Field Units)

3b. With drill pipe in the hole, and the well shut using the ram preventer. Is it
possible to circulate down the drill pipe and take returns to the choke manifold?

a) YES
b) NO

3c. With drill pipe in the hole, is it possible to shut the well in under pressure and
change out the Blind Shear Ram inserts?

a) YES
b) NO

3d. With drill pipe in the hole, is it possible to shut the well in under pressure and
repair a leaking hydraulic valve on the choke line?

a) YES
b) NO

3e. With drill pipe in the hole, is it possible to shut the well in under pressure and
repair a leaking annular preventer?

a) YES
b) NO

3f. With drill pipe in the hole, and the well shut in under pressure using the annular
preventer. Is it possible to repair a leaking hydraulic side outlet valve?

a) YES
b) NO

4. The manifold regular by-pass valve on the central hydraulic control unit
(Koomey Unit) is normally kept closed. This valve can also be operated from the
Driller’s remote control panel. Which of the following will happen if it is opened?

a) It will put accumulator pressure on the annular preventer.

b) It will reduce the accumulator pressure to 1500 psi.

c) It will put the accumulator pressure on the manifold selector valves.

d) It will isolate the rams preventers, bleeding off all positive closing pressure.

Revised February 2010 3


IWCF Surface Well Control
Exercise No. 11
API (Field) Units

5. A 15,000 psi working pressure BOP stack has a closing ratio of 11.56:1. The fluid
volume required to operate all of the BOP functions is 135 gallons. The pre-
charge pressure is 1000 psi and the maximum system hydraulic working
pressure is 3000 psi. Calculate the minimum number of 10 gallon accumulator
bottles required for this system.

Answer: bottles

6. Figure S11-003 illustrates a hydraulic BOP control unit.

Figure S11-003

Match the correct numbers to the descriptions below.


(One point for each correct answer)

6a. ____ Bypass Valve


6b. ____ Air Filter
6c. ____ Accumulator shut off valve
6d. ____ Annular Preventer "Unit/Remote" switch
6e. ____ Annular Pressure Gauge
6f. ____ Manifold Pressure Gauge

Revised February 2010 4


IWCF Surface Well Control
Exercise No. 11
API (Field Units)

7. What is understood by the expression "Stand-off between flanges”, when


installed and made up?

a) The external diameter of the flange.


b) The total height of the two flange assembly.
c) The internal diameter of the flange.
d) The distance between the two flanges when installed with the studs and nuts
tightened.

Answer questions 8 and 9 based on the following gauges seen on an air-operated


Master BOP Panel.

Accumulator Manifold Annular Rig Air


Pressure Pressure Pressure Pressure
(psi) (psi) (psi) (psi)

2800 1500 400 110

8. Could a ram preventer be operated from this panel, and closed within the API
specified time?

a) Yes.
b) No.

9. Could the annular preventer be operated from this panel, and closed within the
API specified time?

a) Yes.
b) No.

10. The accumulator charge pumps on the main hydraulic control unit are controlled
by their respective pressure switches and should operate:

a) When the accumulator pressure has decreased to less than 90% of its operating
pressure, and will shut itself off when its pressure reaches its maximum operating
pressure.
b) When the accumulator pressure has decreased to less than 70% of its operating
pressure, and will shut itself off when its pressure reaches its maximum operating
pressure.
c) When the accumulator pressure has decreased by more than 90% of it’s operating
pressure, and will shut itself off when its pressure reaches the maximum operating
pressure.

Revised February 2010 5


IWCF Surface Well Control
Exercise No. 11
API (Field) Units

11. A regulator can be adjusted to give an increased accumulator pressure for


shearing S135 drill pipe?

a) True.
b) False.

12. Use the illustration of the mud gas separator in Figure S11-004 and the following
data to calculate the maximum allowable operating pressure before gas blow-
through may occur:-

H1 - body height = 26 feet. H2 - dip tube height = 16 feet.


H3 - derrick vent line height = 130 feet. Mud density = 12.6 ppg

Figure S11-004

a) 10.0 psi.
b) 10.5 psi.
c) 27.6 psi.
d) 27.3 psi.
e) 10.6 psi

Revised February 2010 6


IWCF Surface Well Control
Exercise No. 11
API (Field Units)

13. Can a regulator on a BOP control unit be set to apply accumulator pressure on
either the opening or closing side of a ram preventer?

a) Yes.
b) No.

14. Figure S11-005 illustrates a Cameron U-Type Ram BOP.

Figure S11-005

Match the correct numbers to the descriptions below.


(One point for each correct answer)

14a. ____ Bonnet


14b. ____ Operating Piston
14c. ____ Ram assembly
14d. ____ Operating cylinder
14e. ____ Body
14f. ____ Ram Lock Screw
14g. ____ Intermediate flange

15. Which Ram type Preventer on a Cameron 13-5/8, 10,000-psi BOP stack is
equipped with thicker intermediate flanges?

a) Pipe rams.

b) Blind rams.

c) Shear rams.

d) Variable rams.

Revised February 2010 7


IWCF Surface Well Control
Exercise No. 11
API (Field) Units

`
16. The manifold regulator on a surface BOP control unit can be adjusted at the
master remote driller’s panel provided the control switch is in the "remote"
position?

a) True.
b) False.

17. Some components in Figure S11-006 are numbered.

Figure S11-006

Enter the appropriate number which matches the component description.

17a. ____ Closing port


17b. ____ Opening port
17c. ____ Donut
17d. ____ Piston
17e. ____ Ring groove

Revised February 2010 8


IWCF Surface Well Control
Exercise No. 11
API (Field Units)

18. On a ram type preventer, in which position will the 4-way valve be put to assist
with the removal of the bonnet after backing off the bonnet bolts?

a) Open.
b) Close.
c) Neutral (Block).
d) Any position, it does not matter.

19. A test cup for 9 5/8 casing is used to test a BOP stack to a pressure of 10,000 psi
using 5 inch drill pipe.
The area of the test cup subjected to pressure is 42.4 inch2.
What is the minimum grade of drill pipe to use (exclude any safety margin)

a) Grade E-75 Premium Drill Pipe - Tensile Yield strength = 311,200 lbs.
b) Grade X-95 Premium Drill Pipe - Tensile Yield strength = 394,200 lbs.
c) Grade G-105 Premium Drill Pipe - Tensile Yield strength = 436,150 lbs.
d) Grade S-135 Premium Drill Pipe - Tensile Yield strength = 560,100 lbs.
e) Any grade will withstand the stress of testing.

20. Why are some choke manifolds equipped with a Glycol or Methanol injection
system?
a) To minimise the effects of hot dry desert environments.
b) To help prevent hydrate formation while circulating a kick.
c) To help fluids flow better during well testing.
d) To allow use of the latest models of remote operated chokes.

21. What is the maximum acceptable closing time for a 13 5/8 annular BOP
(According to API RP 16E)?

a) Less than 30 seconds.


b) Less than 45 seconds.
c) Less than 60 seconds.
d) Less than 2 minutes.

22. On the BOP hydraulic control (accumulator) unit the 4 way selector valves can
be placed in any one of three positions?

a) True.
b) False.

Revised February 2010 9


IWCF Surface Well Control
Exercise No. 11
API (Field) Units

23. Figure S11-007 illustrates a typical piping schematic for a surface BOP
installation. All the valves and chokes have been numbered. The well is shut in
on the annular BOP.
It is planned to circulate from the mud pumps through the drill string and bleed
off through the manual choke to the mud gas separator.

Figure S11-007

Which one of the following groups of valves and chokes must be open?

a) 2, 3, 5, 8, 9, 10, 11, 12, 15, 17, 23.


b) 2, 3, 4, 6, 7, 8, 9, 10, 11, 14, 16, 19, 23.
c) 2, 3, 5, 8, 9, 10, 14, 16, 19, 20
d) 2, 3, 5, 8, 9, 10, 11, 14, 16,19, 23.

24. On the BOP hydraulic control (accumulator) unit, if a 4 way selector valve is in
the upright or centre position, which of the following is correct?

a) The regulated power fluid inlet will be blocked. Both outlets will be vented back into
the fluid reservoir tank.
b) The inlet and outlet ports will be blocked.
c) The inlet and both outlets will be vented back into the fluid reservoir tank.

Revised February 2010 10


IWCF Surface Well Control
Exercise No. 11
API (Field Units)

25. Figure S11-008 illustrates a pipe ram.

Figure S11-008

Match the correct numbers to the descriptions below.


(One point for each correct answer

25a. ____ Ram body


25b. ____ Extrusion plate
25c. ____ Ram assembly
25d. ____ Top seal

26. The annular regulator on a surface BOP control unit can be adjusted at the
master remote driller’s panel provided the control switch is in the "unit"
position?

a) True.
b) False.

27. Each closing unit should have a fluid reservoir with a capacity equal to at least
twice the usable fluid capacity of the accumulator system.

a) True.
b) False.

Revised February 2010 11


IWCF Surface Well Control
Exercise No. 11
API (Field) Units

Answer questions 28 to 31 based on the following gauges seen on an air-operated


Master BOP Panel.

Accumulator Manifold Annular Rig Air


Pressure Pressure Pressure Pressure
(psi) (psi) (psi) (psi)

3000 1500 1000 20

28. Could a ram preventer be operated from this panel, and close within the API
specified time?

a) Yes.
b) No.

29. Could an annular preventer be operated from this panel, and close within the API
specified time?

a) Yes.
b) No.

30. Could any preventer be operated from the main hydraulic control unit (Koomey
Unit)?

a) Yes.
b) No.

31. What is a 7 1/16 inch, 10,000-psi flange?

a) This flange is designed for RX ring gasket type.


b) This flange has a 10,000-psi test pressure and 5,000-psi working pressure.
c) This flange has a 10,000-psi working pressure and 7 1/16 inch ID.
d) This flange has a 7 1/16 inch OD and a 10,000-psi working pressure.

32. Could a regulator be adjusted at the main hydraulic control unit (Koomey Unit)?

a) Yes.
b) No.

Revised February 2010 12


IWCF Surface Well Control
Exercise No. 11
API (Field Units)

33. A surface BOP stack has one annular preventer, three ram preventers and two
hydraulic H.C.R. valves. To close, open and close all of the above functions will
require 20 x 10 gallon accumulator bottles. The accumulator pre-charge
pressure is 1000 psi. If the working pressure of the control unit is 3000 psi and
the minimum working pressure is 200 psi above pre-charge pressure, how many
gallons of usable fluid is stored in the accumulator bottles?

Answer: gallons

34. Using the information is question 33, if the minimum working pressure was
increased from 1200 psi to 1470 psi. How many additional 10 gallon accumulator
bottles would now be required?

Answer: bottles

35. Using the information is question 33. Calculate the total accumulator volume of
this number of bottles.

Answer: gallons

36. The purpose of a weephole on a ram preventer is:

a) It can be used as an inspection port to determine the wear on seals or on that part
of the ram shaft.
b) To inject plastic packing into a retaining ring around the ram shaft in the seal area.
c) It will prevent a build-up of pressure in the ram shaft seal area if a mud seal fails.
d) As it is open to atmosphere it will provide pressure stability to the ram shaft seals.

37. According to API recommended practice, what is the usable fluid volume of an
accumulator bottle?

a) The total volume to be stored in the accumulator bottle.


b) The volume of fluid recoverable from an accumulator bottle, between the
accumulator operating pressure and 200 psi above the bottle pre-charge pressure.
c) The volume of fluid recoverable from an accumulator bottle, between the
accumulator operating pressure and the pre-charge pressure.
d) None of the above.

Revised February 2010 13


IWCF Surface Well Control
Exercise No. 11
API (Field) Units

38. Figure S11-009 illustrates a style of diverter commonly used when drilling with a
surface BOP.

Figure S11-009

Match the correct numbers to the descriptions below.


(One point for each correct answer).

38a. ____ Flow line


38b. ____ Vent line
38c. ____ Diverter close port
38d. ____ Actuating piston
38e. ____ Body

Revised February 2010 14


IWCF Surface Well Control
Exercise No. 11
API (Field Units)

39. On a surface installation the accumulator pumps should be capable of closing


the annular preventer on the size of drillpipe being used, plus opening the
hydraulically operated choke line valve and obtain a minimum of 200 psi
pressure above accumulator pre-charge pressure on the closing unit manifold
within two minutes or less?
a) True.
b) False.

40. There is only one inside BOP with NC50 pin connection on the rig and the drill
string consists of 5 inch drill pipe, 5 inch HW drill pipe (NC50) and 8 inch drill
collars (6 5/8 inch REG). Which one of the following crossovers must be on the
floor in case of a kick whilst tripping?
a) NC50 (4 ½ inch IF) Box x 7 5/8 inch REG Pin.
b) NC50 (4 ½ inch IF) Box x 6 5/8 inch REG Box.
c) 6 5/8 inch REG. Box x 7 5/8 inch REG Pin.
d) NC50 (4 ½ inch IF) Box x 6 5/8 inch REG Pin.

41. Pump pressure rating requirements: Each closing unit must be equipped with
pumps that will provide a discharge pressure equivalent to the rated working
pressure of the closing unit.
a) True.
b) False.

42. What is the purpose of the Blind/Shear Rams?


a) To shear tubulars like drill pipe while simultaneously sealing the hole.
b) To shear tubulars like drill pipe without sealing the hole.
c) To effect a seal with drill collars in the hole.

43. What would be the effect of fitting a 7 1/16 inch x 5,000-psi flange to a working
10,000 psi rated BOP stack?
a) The rating would remain at 10,000-psi.
b) The rating would become 5,000-psi.
c) The rating would become 7,500-psi.

44. On a surface installation the 4 way selector valves can be placed in any one of
three positions from the drillers remote air operated master panel.
a) True.
b) False.

Revised February 2010 15


IWCF Surface Well Control
Exercise No. 11
API (Field) Units

45. On a Cameron shear ram fitted with a rambooster to shear drill pipe, the
intermediate flange needs to be thicker in order to avoid damaging the shear
blades when closed.

a) True.
b) False.

46. Figure S11-009 illustrates an inside blowout preventer.

Figure S11-009

Match the correct numbers to the descriptions below.


(One point for each correct answer).

46a. ____ Valve spring


46b. ____ Release tool
46c. ____ Valve seat
46d. ____ Valve release rod
46e. ____ Upper body

Revised February 2010 16


IWCF Surface Well Control
Exercise No. 11
API (Field Units)

47. What is the main function of the choke in the overall BOP system?

a) To direct fluid to the mud degasser via the choke manifold.


b) To direct hydrocarbons to the flare.
c) To shut the well in softly to avoid exceeding the MAASP.
d) To maintain back pressure in the system.

48. Select three items of equipment that may warn of increasing formation pressure
while drilling overbalanced?
(Select THREE answers)

a) ROP recorder.
b) Pump stroke counter.
c) Gas detector.
d) Casing pressure gauge.
e) Mud temperature recorder.
f) Stand pipe pressure gauge.

49. The degasser is normally positioned up-stream of the choke in a well control
situation.

a) True.
b) False.

50. The blow-down lines are normally situated on the down stream side of the
mud/gas separator.

a) True.
b) False.

51. The liquid seal pressure is a term applied to poor boy degasser’s (Mud Gas
Separator). Which of the following best describes the liquid seal?

a) Liquid seal pressure is the maximum safe operating pressure limit within
the vessel.
b) Liquid seal pressure is the minimum safe operating pressure limit within
the vessel.
c) Liquid seal pressure or a pressure in excess of it, will exceed the operating
pressure limit of the vessel.

Revised February 2010 17


IWCF Surface Well Control
Exercise No. 11
API (Field) Units

52. What is the normal operating position of the 4-way valves on the BOP hydraulic
control (accumulator) unit while drilling?

a) Neutral (Block) position for all valves.


b) Open or closed depending on BOP stack function.
c) All valves in open position.
d) All valves in closed position.

53. Where are the proximity (activating) switches for the BOP remote panel lights
situated?

a) On the pressure gauge mounted on the remote control panel.


b) On the BOP hydraulic control (accumulator) unit.
c) Inside the BOP operating chambers.
d) On the remote control panel operating handles.

54. What is the purpose of the master control valve on an air operated remote BOP
panel?

a) Activates the hydraulic fluid circuit at the panel.


b) Activates the air circuit at the panel.
c) Activates the electric circuit for the open/close lights.
d) Adjusts pipe ram closing pressure.

55. When aluminium drill pipe is used, special consideration must be given to ram
size selection.

a) True.
b) False.

56. Ram preventers are not designed to be pressure tested from the top side.

a) True.
b) False.

Revised February 2010 18


IWCF Surface Well Control
Exercise No. 11
API (Field Units)

57. Field experience has proven that ram preventers are more likely to leak with a
low wellbore pressure than a high pressure.

a) True.
b) False.

58. All ram preventers with a rated working pressure of 5000 psi and above, should
be equipped with secondary piston rod seals in case the primary rod seal fails.
The secondary seal is plastic which is stored in a cavity until it is activated by
forcing it around the ram rod. This plastic seal is used only during emergency
situations and is designed for static conditions, any movement of the rod after
this plastic packing has been activated, will cause rapid wear to both seal and
rod.

a) True.
b) False.

59. The primary rod seal must always be replaced when the emergency is over.

a) True.
b) False.

60. The front elements of ram seals have steel plates bonded to the rubber. As the
rams are brought together, these steel plates meet before the preventer is fully
closed. Further movement of the ram bodies causes extrusion of the rubber
element, thereby effecting a seal.
If the rams are used for stripping pipe, the front face of the ram sealing element
will wear. The self-feeding action brought about by the steel plates, will ensure
that rubber from the packing element moves forwards to replace that which is
worn away.
a) True.
b) False.

61. Standard pipe rams are designed to centralise and pack off around one specific
size of drillpipe or casing.

a) True.
b) False.

Revised February 2010 19


IWCF Surface Well Control
Exercise No. 11
API (Field) Units

62. Consideration for the selection of BOP packing elements:

a) Should be chosen according to the depth and geometry of the well to be drilled.
b) Should be chosen according to the type of mud system to be used.
c) Should be chosen according to the type of hydraulic fluid used in the BOP closing
unit.

63. In figure S11-010 below , identify the following types of connections on each
BOP.

Figure S11-010

Match the correct letter to the descriptions below.


(One point for each correct answer).

63a. ____ Integral clamp hub connection


63b. ____ Studded connection
63c. ____ Flange connection

Revised February 2010 20


IWCF Surface Well Control
Exercise No. 11
API (Field Units)

64. Which one of the following gaskets matches the 6BX type flange?

a) Type BX.
b) Type R Octagonal.
c) Type R Oval.
d) Type RX.
2 points

65. Given the volumes below, how much hydraulic fluid will be required to carry out
the following operations (no safety margin)?

Operations: Close, open then close again


Equipment: One annular preventer
Three pipe rams
Volumes:
Annular Preventer : 18 gallons to close, 15 gallons to open
Pipe ram : 6 gallons to close, 5 gallons to open

a) 66 gallons.
b) 102 gallons.
c) 68 gallons.
3 points

66. During a well control operation 4000 psi was shut in below the middle pipe rams:

Ram type BOP data:

MODEL: Cameron U Type


RATED WORKING PRESSURE: 15,000 psi
NOMINAL SIZE: 7 1/16 inch.
CLOSING RATIO: 6.9.
OPENING RATIO: 2.2.

It is decided to strip the tool joint through the middle pipe rams.

Which one of the following is the Driller’s next step?

a) Initially, close the upper pipe rams above the tool joint. Then open the middle pipe
rams.
b) Initially, close the upper pipe rams above the tool joint. Then activate the By-pass
function on the BOP panel to get sufficient pressure from the accumulators. Then
open the middle pipe rams.
c) Initially, close the upper pipe rams above the tool joint. Then pump in 4000 psi
pressure between the middle rams and upper pipe rams. Then open the middle
pipe ram.
3 points

Revised February 2010 21


IWCF Surface Well Control
Exercise No. 11
API (Field) Units

67. The closing pressure on annular preventers should be reduced when running
large diameter casing or coiled tubing to avoid collapse.

a) True.
b) False.

68. While drilling the lights on the drillers remote panel for the BOP should be?

a) All red.
b) All green.
c) Some red, some green.
d) It doesn’t matter as this panel is only used in an emergency.

69. Hydraulically operated ram preventers are provided with locking screw stem
extensions and large diameter hand wheels similar to the operating screws of
manually closed preventers. The main purpose of the locking screws is to
manually lock the ram in the closed position after they are closed hydraulically.
In an emergency, the screws can be used to close the rams, the closing unit
selector valve should be in the closed position. This will eliminate the possibility
of hydraulic oil being trapped on the opening side of the actuating pistons.

a) True.
b) False.

70. Bonnet (or door) seals are exposed to wellbore pressures and fluids. Since they
can be subjected to high pressures and temperatures without being backed-up
by another seal, the bonnet seals are therefore critical to the integrity of the BOP
system.

a) True.
b) False.

71. If a function is operated on the remote BOP panel on the rig floor without
operating the master control valve, the function will work:-

a) Slower.
b) Faster.
c) The same.
d) Will not work at all.

Revised February 2010 22


IWCF Surface Well Control
Exercise No. 11
API (Field Units)

72. On which ram would you be most likely to use the bypass (manifold valve)
facility.?
a) Variable bore rams.
b) Blind/Shear rams.
c) 5-inch pipe rams.
d) 31/2 inch pipe rams

73. Which gas is used to pre-charge BOP hydraulic control (accumulator) unit
bottles?
a) Air.
b) Nitrogen.
c) Oxygen.
d) Carbon Dioxide (CO2).

74. On which two gauges on a remote control panel would a reduction in pressure
be observed when the 3 ½ inch pipe rams are closed?
(Select TWO answers)
a) Annular pressure gauge.
b) Manifold pressure gauge.
c) Air pressure gauge.
d) Accumulator pressure gauge.

75. What is the minimum recommended pre-charge pressure for the bottles on a
3,000-psi BOP hydraulic (accumulator) unit, according to API recommendations?

a) 3,000 psi.
b) 1,000 psi.
c) 1,200 psi.
d) 800 psi.

76. While drilling, the pressure on the ram opening lines between the BOP hydraulic
control (accumulator) unit and the BOP stack would normally be:

a) zero
b) 500 psi.
c) 1,500 psi.
d) 3,000 psi.

Revised February 2010 23


IWCF Surface Well Control
Exercise No. 11
API (Field) Units

SURFACE WELL CONTROL EXERCISE NO. 11

EQUIPMENT

ANSWERS

1. A, C

2. C

3a. A
3b. B
3c. A
3d. A
3e. A
3f. A

4. C

5. 31 bottles

6a. 15, Bypass valve


6b. 18, Air filter
6c. 5, Accumulator shut off valve
6d. 17, Annular preventer "unit/remote" switch
6e. 13, Annular pressure gauge
6f. 3, Manifold pressure gauge

7. D

8. A, Yes - Manifold pressure is 1500 psi

9. B, No - Annular pressure is only 400 psi

10. A, Normal hydraulic operating pressure range is between 2700 to 3000 psi

11. B, No - The regulator will increase manifold pressure not the accumulator pressure.
12. A, Hydrostatic pressure of dip tube is 12.6 x 0.052 x 16 = 10.48 psi. Operating with a
pressure above 10.48 would cause a blow-through to the shaker. Answer 10 psi.

13. B, False - The Bypass valve applies accumulator pressure. A regulator can normally
only adjust manifold pressure up to 1500 psi.

14a. 11, Bonnet


14b. 12, Operating piston

Revised February 2010 24


IWCF Surface Well Control
Exercise No. 11
API (Field Units)

14c. 3, Ram assembly,


14d. 8, Operating cylinder
14e. 4, Body
14f. 7, Ram lock screw
14g. 10, Intermediate flange

15. C, Shear rams


16. B, False - The unit/remote controls annular pressure. There is normally no pressure
adjustment for manifold pressure at the remote panel on a surface stack.

17a. 9, Closing port


17b. 4, Opening port
17c. 6, Donut
17d. 8, Piston
17e. 5, Ring groove
18. B
19. C
20. B
21. A
22. A
23. D
24. B

25a. 2, Ram body


25b. 1, Extrusion plate
25c. 3, Ram assembly
25d. 4, Top seal
26. B, False - The annular regular can only be adjusted from the remote panel when the
Unit/Remote switch is in the remote position
27. A
28. B, No
29. B, No
30. A, Yes
31. C
32. A, Yes
33. 100 gallons
34. 9 bottles
35. 200 gallons

Revised February 2010 25


IWCF Surface Well Control
Exercise No. 11
API (Field) Units

36. C
37. B
38a. 8, Flow line
38b. 5, Vent line
38c. 6, Diverter close port
38d. 3, Actuating piston
38e. 4, Body
39. A, True
40. D
41. A
42. A
43. B
44. B, False
45. A, True
46a. 7, Valve spring
46b. 2, Release tool
46c. 5, Valve seat
46d. 3, Valve release rod
46e. 4, Upper body
47. D
48. A, C, E
49. B, False
50. B, False
51. C, The liquid seal pressure is a pressure that you cannot afford to see.
52. B
53. B
54. B
55. A
56. A
57. A
58. A
59. A
60. A
61. A
62. B

63a. B
63b. A
63c. C

Revised February 2010 26


IWCF Surface Well Control
Exercise No. 11
API (Field Units)

64. A
65. B
66. C
67. A
68. B
69. A
70. A
71. D
72. B
73. B
74. B, D
75. B
76. C

Revised February 2010 27

Вам также может понравиться