Вы находитесь на странице: 1из 116

Energy Management

The Smart Choice for Lighting Control and Energy Solutions


Energy Management

ENERGY CODES AND STANDARDS ARE THE LAW OF THE LAND.


ASHRAE 90.1 2010, IECC, California Title 24 2013 and numerous other local and
national codes and standards demand advanced energy-saving controls lighting
by either mandating compliance or encouraging it with tax incentives and utility
rebates. Programs like LEED Certification offer businesses incentives for meeting
benchmarks guided by national codes and standards. In areas such as California,
energy efficiency isn’t simply an option--it is a requirement to legally operate and
occupy buildings.

COMPETITIVE ADVANTAGE COMMERCIAL STATE ENERGY CODE STATUS


Energy costs are rising faster than As of June 2015
ever before, making the reduction of
energy consumption by businesses
an increasingly more powerful
competitive advantage. With over
38% of a typical business’ energy
bill related to lighting, energy saving
controls for lighting are squarely at
the center of any effort to reduce
energy expenditures.

2
Energy Management Lighting Control Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Sensing Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
LevNet RF™ Wireless Self-Powered Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Wall Switch Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Provolt™ Self-Contained Sensors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Line Voltage Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Low Voltage Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Power Packs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Power Base Adaptor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Outdoor Motion Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Photocells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Room Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
LevNet RF™ Wireless Self-Powered Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Lumina™ RF Wireless Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Integrated Room Control (IRC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Hospitality Key Card Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70

Table of Contents
Centralized Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
GreenMAX® Relay Control System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Track Light Limiting Panel (TLLP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
EZ-MAX® Plus Standalone Relay Control System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Distributed Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Sector® Intelligent Digital Lighting Control System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
VerifEye™ Submetering Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90

www.leviton.com/les 3
4
LEVITON COMMERCIAL LIGHTING CONTROL SOLUTIONS
Every industry, facility and application has different lighting control needs. Some needs can be met with a simple solution, such
as an occupancy sensor, while others require the advanced customization and control of GreenMAX® and Sector® systems.
Leviton offers a spectrum of lighting control and energy management strategies to meet any application:
• Occupancy and Vacancy Sensing Control - A complete line of PIR, ultrasonic, multi-technology and daylight harvesting sensors
• Room Control - LevNet RF™ Wireless Self-Powered Solutions, and Integrated Room Control (IRC)
• Centralized Control - EZ-MAX® Plus and GreenMAX® Relay Control Systems
• Distributed Control - Sector® Intelligent Digital Lighting Control Systems
• Hybrid Controls - Combined Leviton technologies to meet any application with customized control
• Metering Solutions - VerifEye™ Submetering Solutions include submetering equipment, data collection and software
products, for energy monitoring and tenant billing options

Lighting Control Solutions | Commercial

*Please see the Leviton Commercial Entertainment Product Catalog for more information, or visit Leviton.com/Entertainment.
**Please see the Leviton Commercial Architectural Controls Catalog for more information, or visit Leviton.com/Architectural.

www.leviton.com/les 5
Leviton Lighting Control Solutions can be selected and tailored to commercial, institutional and industrial
applications including:
• Single, small, midsize and large office complexes • Retail spaces • Airports
• K-12 schools and college campuses • Municipalities • Warehouses
• Museums, convention centers and lecture halls • Houses of worship • Restaurants
• Health care and hospital facilities • Shopping malls and complexes • Government facilities
• Prison and correctional facilities • National parks and monuments

Leviton Lighting Control Solutions help facilities meet energy saving and lighting control goals. Using simple and advanced
methods, Leviton solutions leverage energy saving technologies for:

Code Compliance Implementing a Leviton solution as a new construction or retrofit project can meet requirements set by
state, federal and local municipal codes for sustainability and energy efficiency. Tax incentives and utility company rebates
are also available for eligible projects. Leviton devices can help meet ASHRAE Standard 90.1 2010, California Title 24 2013,
IECC and LEED certification requirements. Learn more about specific product code compliance at
www.leviton.com/energycodes.
Dimming Reduces
Dimming and Switched Lighting Whether switching lights ON or OFF based on incandescent energy
occupancy or subtly dimming multiple zones, reducing lighting is one of the easiest ways lights by: consumption by:
Lighting Control Solutions | Commercial

to reduce overall electricity consumption. Leviton dimming and switching products


10% 10%
include: box-mounted dimmers; scene dimming stations and controllers; and sophisticated
multizone dimming systems that incorporate dimming and relay cabinets, architectural 25% 20%
lighting and more. These products can help buildings meet mandatory ASHRAE 90.1 and 50% 40%
Title 24 requirements. 75% 60%

LED Ready LED lighting is one form of adaptive lighting with dimming capabilities and dramatically reduces energy needed to
power light fixtures. LEDs can be used with a variety of control types including 1-10V dimming, sourcing, sinking, 0-120VAC
reverse and forward phase, DMX and other applications.

Occupancy Detection Occupancy sensing takes the burden of lighting control from occupants and into a self-contained,
automated system. Numerous styles of occupancy sensors accommodate a broad range of coverage areas and patterns of
usage. Leviton’s occupancy sensor line includes commercial and residential, self-powered wireless, wide-view and high-bay,
dual-relay and outdoor models for a broad range of coverage areas and patterns. These products can help buildings meet
mandatory ASHRAE 90.1, IECC and Title 24 requirements, and are applicable toward earning LEED certification points.

Timed Controls Using timers to automate switching of lights and other loads is a simple way to ensure that devices are
only on for a set period of time. Sophisticated relay systems (such as EZ-MAX Plus and GreenMAX) provide advanced load
scheduling based on scheduled or astronomical time. Leviton offers preset and programmable timer switches as well as relay
systems that integrate with lighting and other building controls in commercial and industrial applications. These products
can help buildings meet mandatory ASHRAE 90.1, IECC and Title 24 requirements, and are applicable toward earning LEED
certification points.

Integration with Building Controls Integrating lighting, security, HVAC and other building management systems into a single
control system provides optimal energy efficiency. Integrated systems provide superior interoperability as well as essential
function for companies participating in load shedding programs. Leviton energy management components are building
blocks that can interact with other Leviton products and, in some cases, with non-Leviton building controls.

Demand Response Demand response POTENTIAL SAVINGS WITH LIGHTING CONTROL STRATEGIES
is an energy conservation strategy that
involves reducing lighting loads during 100% 95%
peak energy usage times. These high- 85%
demand times of day are communicated 80%
by the utility company to the facility
through the use of building automation
60% 60%
systems (BAS) or building management
systems (BMS). Demand response is 46%
mandatory to meeting California Title 40%
24 code requirements. GreenMAX Relay
27% 26%
Control Systems, IRC, Dimensions® 20% 23% 23%
20%
D4000 and Sector Distributed Control
Systems all provide demand response
capabilities. 0%
All Strategies Occupancy + Occupancy + Occupancy + Load Dimming: Dimming: Occupancy Bi-Level
Daylighting + Daylighting Hold Off Shedding Task Tuning Daylighting Sensors Switching
Task Tuning Photocell

6
Daylighting By utilizing present natural light within Average Daylighting Savings for Commercial Facilities
a space, facilities reap the dual benefits of reduced
energy usage and a more pleasant, ambient building
environment. Photocells and timed systems (such as Standard Savings
GreenMAX, EZ-MAX Plus, IRC and Sector) measure light

Cost of Lighting Energy $/sf/yr


From Task
-8¢ Lighting (20%)
provided by windows, skylights and open spaces and dim
or switch OFF overhead lighting accordingly. Leviton offers
photocells, occupancy sensors, relay cabinets, dimmers From Daylighting
and dimming systems for daylighting strategies. These -13¢
(35%)
products can help buildings meet mandatory code and 40¢
standard requirements. From Occupancy
32¢ -6¢ Sensors (18%)

19¢
BENEFITS FROM DAYLIGHTING 13¢
• Energy savings
• Reduce peak electric load Source: Midwest Energy Efficiency Alliance

• Allow continued operation during power outages


• Connecting people to their external environment

Lighting Control Solutions | Commercial


• Improved productivity and health

Lighting, heating and air conditioning account for up to 70% of all energy being consumed in today’s modern buildings.
Daylighting controls are the best way to optimize the low cost, natural resource of daylight.

Key energy saving points for daylighting


• Architectural daylighting design utilizing top, side and surface lighting can reduce glare and heat concerns
• Assuring lights are only utilized when light is required and space is occupied
• Automatically balancing natural and artificial light for optimized lighting usage
• Switched or dimmed light loads have less heat emissions which reduces cooling costs
• Solar screening controls lights without eliminating it
• Lighting and Energy Solutions provide total energy efficient control and savings

Source: Commercial Buildings Energy Consumption Survey (CBECS) 1995, released July 1998 by the Energy Information Administration

GREATER HEALTH, WELL BEING Daylight Harvesting


AND PRODUCTIVITY
Studies done by the United States Green
Building Council (USGBC) have shown that
daylighting can improve health, well-being
and productivity of individuals, co-workers,
students and employees. The determining
factors for this are not only from the amount
of natural scenery and light, but from the
quality and color of the artificial lamp light.
Daylight harvesting technology strives to
achieve this optimal color temperature and
rendition to provide visual stimulation for
health, well-being and productivity.

www.leviton.com/les 7
OCCUPANCY SENSING CONTROL
Occupancy sensors deliver one of the simplest and most effective methods of reducing energy usage. Basic rooms such as
restrooms, private offices, medical exam rooms and meeting rooms will see a significant drop in lighting costs when an
occupancy sensor is installed.

GOOD SOLUTION
OCCUPANCY SENSOR WITH MANUAL-ON/OFF CONTROL

PROBLEM: Occupancy sensor control is desired, but manual


overrides by occupants may occasionally be necessary to
accommodate temporary needs.

Wall Switch PIR Sensor


SOLUTION: Occupancy sensors with manual-ON/OFF control
add a level of flexibility to the occupancy sensing solution.
Users can manually override the sensors by switching ON or
OFF to accommodate temporary needs.
• Combines the energy savings of occupancy sensing with
the convenience of manual-ON/OFF switching
Zone 1
• Cost-effective method of regulating lighting usage
Lighting Control Solutions | Commercial

• Ideal Applications: Smaller enclosed areas such as


private offices, conference rooms and storage spaces

SOLUTION REQUIREMENTS
PRODUCT QUANTITY
Occupancy Sensor Good –OS Wall-box Only, 1 Zone
ODS10-IDW PIR Wall Switch Occupancy Sensor
OR OSSMT-MDW Multi-Technology Wall Switch Occupancy Sensor 1
ODS0D-IDW Dual Relay PIR Wall Switch Occupancy Sensor
OR OSSMD Dual Relay Multi-Technology Wall Switch Occupancy Sensor

BETTER SOLUTION
OCCUPANCY SENSOR WITH AUTO-ON/OFF CONTROL

PROBLEM: Facility contains rooms that are sporadically


occupied and do not require manual override capabilities. Provolt PIR
Sensor

SOLUTION: A single auto-ON/OFF occupancy sensor takes


the burden of lighting control off the occupants, ensuring
lights are ON when they are needed and OFF when they
are not.
• Works best in enclosed spaces without obstructions
• Economical solution with immediate results
• Saves a significant amount of energy over traditional
Zone 1
switch-operated spaces
• Ideal Applications: Restrooms, conference rooms,
closets and storage areas

SOLUTION REQUIREMENTS
PRODUCT QUANTITY

Provolt Line Voltage Self-Contained PIR Ceiling Mount Occupancy Sensor


1
ODC04-IDW

Good – OS Only, 1 Zone

8
BEST SOLUTION
OCCUPANCY SENSOR MULTI-ZONE/BI-LEVEL
SWITCHING SOLUTION

PROBLEM: Room is used in multiple applications, and the


same levels of light are not always desired.
Decora®
SOLUTION: By dividing a space into zones, lighting Wall
becomes more versatile. Multi-zone/bi-level switching, Switches
controlled by an occupancy sensor, allows occupants to
accommodate A/V presentations, computer usage and
other tasks where full overhead lighting is not desired.
The integration of occupancy sensors with HVAC relays
Provolt
lends the option of incorporating heating and cooling Multi-Tech
systems into the occupancy sensor control for Zone 1 Zone 2 Ceiling
additional energy savings. Sensor

• Multi-zone/bi-level lighting maximizes energy savings


through use of both manual and automatic controls

Lighting Control Solutions | Commercial


• Offers various lighting settings for different tasks and preferences
• Occupancy sensing adds a valuable, low-cost, energy saving technique
• Flexibility with two zone settings, manual switching controls and HVAC integration
• Ideal Applications: Meeting and conference rooms, classrooms, training areas and small commercial spaces

SOLUTION REQUIREMENTS
PRODUCT QUANTITY
Provolt Line Voltage Occupancy Sensor
O2C15-IDW PIR Ceiling Mount Occupancy Sensor 1
OR 02C20-MDW Multi-Technology Ceiling Mount Occupancy Sensor

Decora Plus Rocker Commercial Grade Switch


2
56081-2

OCCUPANCY SENSING CASE STUDIES

BRONNER’S CHRISTMAS WONDERLAND


Commercial Warehouse Space, Frankenmuth, Michigan
Bronner’s Christmas Wonderland contained a large storage, shipping and receiving
area that was normally illuminated when unoccupied. Leviton divided the warehouse
into separate aisleways, with each aisle containing an OSFHU high-bay fixture-mount
occupancy sensor. Once installed, switching the lights OFF when aisles were unoccupied
equated to a 90% reduction in energy usage.

LAVA BEDS NATIONAL PARK


Parks and Recreation, Tulelake, CA
Lava Beds National Monument contains 47,000 acres of park lands including lava tube
caves, rugged desert terrain and historical sites. Leviton’s LevNet RF products were
selected to help control lighting in common areas, offices and restrooms. The results
were annual savings of approximately 65,000 kWh and $6,400 in energy costs.

www.leviton.com/les 9
BEST SOLUTION
OCCUPANCY SENSOR STAIRWELL SOLUTION

PROBLEM: Stairwell contains two relays that are always


Load 2 Load 1 Load 2 Load 1
ON regardless of occupied state and available natural ON Provolt ON ON Provolt OFF
light. Relays burn out quickly and increase energy costs. Multi-Tech Multi-Tech
Sensor Sensor
SOLUTION: By using Provolt Dual Relay Multi-Technology
Occupancy Sensors, load controls are balanced with
alternating relays while utilizing daylighting to extend the
life of the relays.
Down Up Down Up
• Both loads will automatically turn ON when occupancy
is detected
• Load 1 and Load 2 alternate between ON and OFF when
the sensor’s time delay expires, so that one load is
always ON
• While under daylighting control, if the natural light level Person 1 Person 1
Enters Exits
is sufficient then both loads will be turned OFF,
Lighting Control Solutions | Commercial

regardless of occupancy state


• The manual switch can be used to turn only one load
OFF at a time
• Title 24 Compliant Load 2 Load 1 Load 2 Load 1
ON Provolt ON OFF Provolt ON
• Ideal Application: Stairwells in office buildings and
Multi-Tech Multi-Tech
parking garages Sensor Sensor

Down Up Down Up

Person 2
Person 2
Enters
Exits

SOLUTION REQUIREMENTS
PRODUCT QUANTITY

Occupancy Sensor
2
O2C05-MDW

10
ROOM CONTROL
Leviton Room Control solutions build on the foundation of occupancy sensing to add value and convenience for facilities.
Room controls introduce daylighting capabilities, which takes advantage of natural light entering a space from windows,
skylights and other open spaces. Utilizing daylight to evenly light a room while improving productivity and user experience
diminishes the amount of overhead lighting necessary to light the space.

GOOD SOLUTION
LEVNET RF MULTI-LOCATION SWITCHING
SOLUTION

PROBLEM: Facility wants to implement an occupancy


sensing and daylight harvesting solution, but cannot Wall
interrupt building functionality with a costly wiring Switch
Receiver
project.

SOLUTION: Versatile, easy-to-retrofit and maintenance-


free, LevNet RF offers an ideal energy management
solution. Switches and sensors communicate wirelessly
and respond to ambient light and occupancy within the

Lighting Control Solutions | Commercial


space to turn lights ON and OFF. Self-
Powered
Zone 1 Occupancy
• Energy harvesting solution is easy to install with no Remote Sensor
need to pull or run wires, speeding up installation and Switch
significantly reducing costs
• No batteries means associated labor, material and
maintenance costs are eliminated
• Ideal Applications: Private offices, meeting and
conference rooms, hotel rooms and classrooms with
windows and/or skylights

SOLUTION REQUIREMENTS
PRODUCT QUANTITY

LevNet RF Self-Powered Wireless Occupancy Sensor


1
WSC12-M9N

LevNet RF Remote Switch


1
WSS0S-D9W

LevNet RF Wall Switch Receiver


1
WSS20-G9N (no neutral), -N9N (neutral)

www.leviton.com/les 11
GOOD SOLUTION
IRC 2-ZONE SOLUTION

PROBLEM: Single office space has a daylighting zone


next to windows and a second interior zone, which Controlled
Receptacles
operate at varying levels based on ambient lighting.
Zone 1
SOLUTION: The IRC system allows separate zones to be
Multi-Tech
controlled individually. Connected occupancy sensors Ceiling
and photocells account for different levels of light and/ Sensor
or occupancy in each zone. The IRC keeps lights OFF when Photocell
the room is unoccupied and allows for dimming the lights Lighting Power
in areas where levels of occupancy are not the same. The Zone 2 Control Pack
IRC dimming solution creates a more ambient space by Station

allowing natural light to be utilized in place of overhead IRC,


lighting, which reduces energy use while increasing user 2-Zone
satisfaction.

• Cost-effective solution allows separate zones to be


Lighting Control Solutions | Commercial

centrally controlled with separate dimming needs for


different levels of light and occupancy for each zone
• Adjusts overhead lighting based on daylight present in
each space
• User-friendly system incorporates multiple occupancy
sensors and photocells for streamlined programming
and ease-of-use
• Ideal Applications: Windowed and skylit spaces such
as classrooms, private offices, conference rooms and
small shops

SOLUTION REQUIREMENTS
PRODUCT QUANTITY

IRC Kit for 2 Zones, 2 Relays - includes IRC, sensor, photocell, and control station
RCD20-102

IRC for 2 Zones, 2 Relays


MZD20-102

Multi-Tech Ceiling Mount Occupancy Sensor 1


2000SF, OSC20-R0W

Photocell, Indoor
ODC0P-00W

Lighting Control Station


RLVSW-4LW

OPP20 Super Duty Power Pack


1
OPP20-0D1

Marked “Controlled” Receptacles


1
5362-S1W

12
BETTER SOLUTION
IRC 3-ZONE DAYLIGHTING & DIMMING SOLUTION IRC,
3-Zone
PROBLEM: Room requires manual control of staggered
zones of lights, from the windowed daylighting zone on
back. Additionally, occupants require the flexibility to
manually dim and switch the zones ON and OFF to
Lighting
accommodate temporary needs for presentations, media Control
viewing, etc. in order to comply with conservation codes. Station

SOLUTION: Stagger the dimming of light loads with the


IRC. This room-in-a-box solution includes all necessary Photocell
components of a simple 3-zone system, including the
photocell, occupancy sensor and low voltage switch.
The IRC responds to ambient light, occupancy and
manual input signals to dim lighting based on the
needs of each individual zone. Zones can be manually Multi-Tech
Ceiling Power
dimmed to compensate for specific occupant needs, Sensor Pack
such as switching lights near a projection screen OFF

Lighting Control Solutions | Commercial


during a presentation.

• IRC offers full-range 1-10V dimming to automatically


adjust light levels based on the amount of daylight in
the space
• Occupancy sensors keep lights OFF when the space
is empty, while the photocell measures and manages
Controlled
lighting when occupied for better ambience and energy Receptacle
conservation Zone 1 Zone 2 Zone 3

• Daylight harvesting of 3 zones offers a more


comfortable, ambient environment which increases
end user satisfaction
• Includes demand response capabilities and plug load
control for conservation code compliance
• Ideal Applications: Education applications, hospital
waiting areas and lobbies

SOLUTION REQUIREMENTS
PRODUCT QUANTITY

IRC Kit for 3 Zones, 3 Relays - includes IRC, sensor, photocell, and control station
RCD30-101

IRC for 3 Zones, 1 Relays


MZD30-101

Multi-Tech Ceiling Mount Occupancy Sensor 1


2000SF, OSC20-M0W

Photocell, Indoor
ODC0P-00W

Lighting Control Station


RLVSW-4LW

OPP20 Super Duty Power Pack


1
OPP20-0D1

Marked “Controlled” Receptacles


1
5362-S1W

www.leviton.com/les 13
BEST SOLUTION
LEVNET RF ZONAL AND INDIVIDUAL FIXTURE CONTROL

RF Wireless
Receptacle Sensor RF
Receptacle
Fixture
Wireless
Controller
Dual Rocker
Wall Station
Wireless Dimming
Dimming
Sensor Photocell
Photocell

Wall Switch
Receiver

Daylighting Zone Wall Switch Daylighting Zone

Switch Receiver
Receiver
Relay
Area
Wireless Receiver
Controller
Wireless
Dual Rocker
Sensor
Wall Station
Lighting Control Solutions | Commercial

Fixture Fixture Fixture Fixture


Wall Switch Controllerr Controller Controller Controller
Area Area Area Receiver
Controller Controller Controller
Wireless Energy Wireless Wireless
Sensor Harvesting Sensor Sensor

Fixture Fixture Fixture Fixture


Controller Controller Controller Controller

Dimming
Photocell

Dimming
Photocell Fixture Fixture Fixture Fixture
Controller Controller Controller Controller

Wireless Wireless Wireless Wireless


Sensor Sensor Sensor Sensor

Fixture Fixture Fixture Fixture


Controller Controller Controller Controller

Zone 1 Zone 2 Zone 3

Daylighting Zone Daylighting Zone

PROBLEM: Facility with multiple rooms wants to implement one energy management system as a retrofit. Some overhead
lights should respond to occupancy sensing and daylighting controls as one controlled zone, while other fixtures require
individual manual and sensing controls.

SOLUTION: LevNet RF system components can be combined to create dynamic lighting options for a variety of spaces.
Zones can be designated in rooms by connecting LevNet RF dimmer modules to ganged fixtures, which respond to the
occupancy sensor, and switch signals to dim lighting by groups of lights incrementally further from daylight sources. In large
open spaces where windows are not present, individual fixtures or small groups of fixtures can be switched ON or OFF by
occupancy sensors and manual switching.

• Easy-to-retrofit, energy harvesting technology can be installed and modified to accommodate evolving needs of the space,
significantly reducing labor and material costs
• Create zonal control by assigning one dimmer module to a ganged set of fixtures and an associated switch, or individual
fixture control by placing one line voltage per dimmer module fixture to respond to occupancy sensor signals. The entire
area can be manually controlled ON or OFF by switch for low-cost flexibility.
• Ideal Applications: Schools, college campuses, libraries, municipal buildings, mixed-use commercial and residential spaces
and hospitality

14
SOLUTION REQUIREMENTS
PRODUCT QUANTITY
LevNet RF Fixture Controller
16
WSD05-9D0

LevNet RF Area Controller


5
WSD20-9D0

LevNet RF Energy Harvesting Occupancy Sensor


11
WSC12-M9N

LevNet RF Wall Switch Receiver


4
WSS20-9GN

LevNet RF Dual Rocker Energy Harvesting Wall Station


2
WSS0S-D9W

LevNet RF Receptacle (15A)


2

Lighting Control Solutions | Commercial


WSG15-S9W or WSG15-D9W

ODC0P Low Voltage 1-10V Dimming Photocell


4
ODC0P-D0W

ROOM CONTROL CASE STUDY

UC SANTA CRUZ SCIENCE AND ENGINEERING LIBRARY


Post-Secondary Education, Santa Cruz, California
The Science and Engineering Library is one of two libraries that serve
over 16,000 students on the UC Santa Cruz campus. Faced with time
constraints and the high cost of conventional wired technologies, the
energy group chose to use Leviton’s energy harvesting technologies to
achieve their energy goals. LevNet RF receivers paired to self-powered
occupancy sensors and light sensors contributed to the energy retrofit
of the existing fluorescent fixtures from T12 to T8 and saved an actual
50% of energy consumption in the facility—an anticipated $48,000
energy cost savings annually.

www.leviton.com/les 15
CENTRALIZED CONTROL
Total facility control from one access point is the goal of Leviton’s Centralized Control Solutions. Relay panels, including the
EZ-MAX Plus and GreenMAX models, integrate multiple room controls into a single system that reduces troubleshooting,
narrows the scope of maintenance and expedites installation, which translates into significant labor cost savings. With
advanced features such as GreenMAX’s programmable Behaviors, centralized control systems open up new possibilities for
managing energy use while making the facility safer, smarter and more user-friendly.

GOOD SOLUTION
EZ-MAX PLUS RELAY ZONAL CONTROL
Controlled
Receptacles
PROBLEM: More precise energy control is required in
the building, such as programming a school’s daily class
schedule. Low
Voltage
Switch EZ-MAX
SOLUTION: EZ-MAX Plus offers programmed energy Plus
management in an affordable, compact, stand-alone
relay panel system. The system can be easily programmed
to automatically turn lights ON or OFF based on planned
times (open/close) or astronomical clock (sunrise/
Lighting Control Solutions | Commercial

Photocell
sunset). Occupancy sensor and photocell integration
enhance programmed settings with daylight harvesting
and ON/OFF occupancy switching.

• Single point of facility control saves on labor and


maintenance costs
• Programmable ON/OFF features consistently keep
lights ON when lighting is needed and OFF when it is
Multi-Tech
unnecessary Ceiling
• Time clock feature is useful for controlling common Sensor
areas and site lighting for added safety in courtyards,
parking lots, etc.
• ASHRAE 90.1 and Title 24* Compliant
• Ideal Applications: Restaurants, offices, houses of
worship and retail spaces
* Note: Receptacle control is not required to meet California Title 24
2013 compliance in classrooms. Visit www.leviton.com/title24 for more
information.

SOLUTION REQUIREMENTS
PRODUCT QUANTITY

EZ-MAX Plus 8-Relay Panel


1
R08BD-L30

Multi-Technology Ceiling Mount Occupancy Sensor


1
OSC20-RMW
ezMax 2 zone
Photocell*
1
ODC0P-00W

Low Voltage 2-Button Switch


1
00LVS-02W

Marked “Controlled” Receptacles


1
CR020-1PW

*Upgrade to 1-10V Dimming Photocell ODC0P-D0W for daylight harvesting applications

16
BETTER SOLUTION
EZ-MAX PLUS RELAY—A/V CLASSROOM
Controlled
Receptacles
PROBLEM: Facility seeks to incorporate timing and
astronomical clock control into a facility where Low
overhead lights are designed to be manually controlled Voltage
to accommodate presentations, media viewing, etc. 4-Button
EZ-MAX
Zone 1 Zone 2 Zone 3 Switch Plus
SOLUTION: The EZ-MAX Plus solution allows for modern
schools to accommodate evolving classroom needs.
Many classes now include dynamic visuals requiring the
use of projection screens, TV and computer monitors
Photocell
as presentation tools. EZ-MAX Plus can be programmed
to control the lighting zone at the head of the class
separately from the lights over desks.

• Reduce eye strain from trying to watch A/V


presentations in full overhead light
• Allows instructors to adjust lighting in presentation

Lighting Control Solutions | Commercial


area while the student zone remains lit by ambient and
overhead lighting for note-taking Multi-Tech
Ceiling
• ASHRAE 90.1 and Title 24* compliant Sensor
• Ideal Applications: K-12 classrooms, college campuses
and office training facilities
* Note: Receptacle control is not required to meet California Title 24
2013 compliance in classrooms. Visit www.leviton.com/title24 for more
information.

SOLUTION REQUIREMENTS
PRODUCT QUANTITY

EZ-MAX Plus 8-Relay Panel


1
R08BD-L30

Multi-Technology Ceiling Mount Occupancy Sensor


1
OSC20-RMW

Photocell*
1
ODC0P-00W

Low Voltage 4-Button Switch


1
00LVS-04W ezMax 3 zone

Marked “Controlled” Receptacles


1
CR020-1PW

*Upgrade to 1-10V Dimming Photocell ODC0P-D0W for daylight harvesting applications

www.leviton.com/les 17
BEST SOLUTION
GREENMAX RELAY CONTROL PANEL CAMPUS SOLUTION

Controlled Controlled
GreenMAX Receptacles
Receptacles

Multi-Tech
Photocell Ceiling 4-Button Multi-Tech
Sensor Digital Ceiling
Switch Sensor
4-Button
Digital
Switch Zone 1 Zone 2 Zone 3 Zone 4
Zone 1 Zone 2 Zone 3

1-Button Digital Switch 1-Button Digital Switch


Lighting Control Solutions | Commercial

4-Button 4-Button
Digital Digital
Switch GreenMAX
Switch

Multi-Tech Multi-Tech
Ceiling Ceiling
Sensor Controlled Sensor
Photocell Controlled Receptacles
Receptacles

Multi-Tech Multi-Tech
Ceiling Ceiling
Sensor Sensor

Zone 1 Zone 2 Zone 3


Zone 1 Zone 2 Zone 3
Key Switch

PROBLEM: Commercial facility has several rooms that utilize occupancy sensors and daylighting technologies, but does not
require specific zonal controls.

SOLUTION: Installing several GreenMAX panels allows for similar rooms to be controlled from a central location.
Pre-programmed Behaviors can be set to anticipate daily routine patterns of usage, along with circumstances such as
closures and breaks. GreenMAX system offers demand response capabilities for Title 24 compliance.

• Practical solution for large buildings with many smaller rooms, but not requiring numerous zonal configurations
• Centralized control for time-settings; ready to integrate with building automation systems
• Ideal Applications: Office buildings, schools, college campuses, municipal buildings, airports

18
SOLUTION REQUIREMENTS
GREENMAX RELAY SYSTEM COMPONENTS

PRODUCT QUANTITY

GreenMAX Relay Cabinet, 8-Relay Size


1
R08TC-100

GreenMAX Relay Cabinet, 32-Relay Size


1
R32TC-100

GreenMAX Main Command Module


2
RPM16-316

GreenMAX Relay Insert Panel - 8-Relay Size


1
R0800-000

GreenMAX Relay Insert Panel - 16-Relay Size with 16 GreenMAX Dimming


Relays 2
R1616-1DS

Lighting Control Solutions | Commercial


GreenMAX Dimming Relays
8
RELAY-1DS

GREENMAX EXTERNAL SYSTEM COMPONENTS


PRODUCT QUANTITY

GreenMAX Handheld Display Unit (HDU)


1
RHDUI-300

GreenMAX Digital Switch, 4-Button


4
RDGSW-4DW

GreenMAX Digital Switch, 1-Button


2
RDGSW-1DW

GreenMAX Digital Switch, Keyswitch


1
RGDSW-1KS

Multi-Technology Ceiling Mount Occupancy Sensor


6
OSC20-M0W

Photocell
2
ODC0P-0DW

Marked “Controlled” Receptacles


4
16352-1PW

www.leviton.com/les 19
BEST SOLUTION
GREENMAX ZONAL CONTROL

GreenMAX GreenMAX

Controlled Controlled
Receptacles Receptacles

Photocell
Multi-Tech
4-Button Ceiling
4-Button Digital
Multi-Tech Sensor
Digital Switch
Ceiling
Switch
Sensor

1-Button Digital Switch 1-Button Digital Switch

1-Button Digital Switch 1-Button Digital Switch

4-Button
Digital
4-Button
Switch
Lighting Control Solutions | Commercial

Digital
Switch

GreenMAX
GreenMAX

MT Ceiling MT Ceiling
Mount OS Mount OS

Photocell
Controlled Controlled
Receptacles Receptacles

MT Ceiling MT Ceiling
Mount OS Mount OS

Key Switch

PROBLEM: Large commercial space has areas that must be controlled independently, and each room has areas that may
need to be segregated by zone for customizable control. The length and amount of wire needed to bring all room controls to
one centralized location would be labor and cost-prohibitive.

SOLUTION: GreenMAX allows large areas, or rooms divided into zones, to be centrally controlled. Pre-programmed Behaviors
can be set in advance to control rooms on common-use settings or for separate circumstances such as closures and breaks.
GreenMAX system offers demand response capabilities for Title 24 compliance.

• Rooms are equipped with photocells and occupancy sensors to achieve optimal daylight harvesting
• Using the sensors and switches allows shorter and less expensive wiring options
• Incorporating smaller panels allows for less wiring and lower installation and maintenance costs
• Centralized control for time-settings; ready to integrate with building automation systems
• Ideal Applications: Office buildings, schools, college campuses, municipal buildings, airports

20
SOLUTION REQUIREMENTS
GREENMAX RELAY SYSTEM COMPONENTS

PRODUCT QUANTITY

GreenMAX Relay Cabinet, 8-Relay Size


4
R08TC-100

GreenMAX Main Command Module


4
RPM16-316

GreenMAX Relay Insert Panels, 8-Relay Size


4
R0800-000

GreenMAX Dimming Relays


32
RELAY-1DS

GREENMAX EXTERNAL SYSTEM COMPONENTS


PRODUCT QUANTITY

Lighting Control Solutions | Commercial


GreenMAX Handheld Display Unit (HDU)
1
RHDUI-300

GreenMAX Digital Switch, 4-Button


4
RDGSW-4DW

GreenMAX Digital Switch, 1-Button


4
RDGSW-1DW

GreenMAX Digital Switch, Keyswitch


1
RGDSW-1KS

Multi-Technology Ceiling Mount Occupancy Sensor


6
OSC20-M0W

Photocell
2
ODC0P-0DW

Marked “Controlled” Receptacles


4
16352-1PW

GREENMAX CASE STUDY

JFK INTERNATIONAL AIRPORT


New York, New York
Receiving more international passengers than any other airport, the JFK
International Airport is the gateway to the United States. As part of a $1.4
billion dollar investment in JFK, Leviton GreenMAX relay control panels were
employed to control general area lighting. The size of the facility proved
challenging, as long network runs between relay panels were required
to connect the Terminal 4 GreenMAX system with the other JFK airport
systems. The GreenMAX system readily handled the challenges of lengthy
network runs and dynamics of one of the world’s largest and busiest
airports. As a result, Levtion enabled Terminal 4 to revolutionize the airport
experience while saving time and conserving energy.

www.leviton.com/les 21
DISTRIBUTED CONTROL
Flexibility, cost-effectiveness and energy efficiency are the goals of Leviton’s Distributed Control Solutions. Sector Intelligent
Digital Lighting Control Systems and SectorFlex integrates scheduling, daylighting, occupancy sensing, dimming and manual
control into an intelligent digital lighting control system. The Sector system is easy to design, install and program and provides
energy savings and increased occupant comfort and productivity.

BEST SOLUTION
SECTOR BALLAST INDIVIDUAL CONTROL

Sector Relay

Sector
Multi-Tech
Lighting Control Solutions | Commercial

Sector Ceiling Sector


Photocell Sensor Sector Multi-Tech
5-Button Ceiling
Switch Sensor
Sector
5-Button
Switch
Sector Bus
Controller

Sector
Sector 5-Button
Multi-Tech Sector
Switch
Ceiling 5-Button
Sensor Switch

Sector
Multi-Tech
Sector Ceiling
Photocell Sensor

Sector
Multi-Tech
Ceiling
Sensor

Sector
Multi-Tech
Ceiling
Sensor

22
PROBLEM: New construction is beginning on a facility that will have multiple uses, and may be configured in different ways in
the future based on changing tenants. Each room will be used in unique ways: there will be some cubicle areas where users
would prefer to control lights directly above and around them, and other areas where overhead lights should be controlled as
one seamless unit.

SOLUTION: The Sector solution includes Sector 1-10V LED drivers, controllers, occupancy sensors, photocells and switches
and a GUI software interface for a scalable solution that serves a variety of facilities. Individual control allows occupants to
control their light from their personal computer, and also frees up a space to be used in various, evolving ways. For example,
a large open space can be built with Sector implemented for a retail application, but in the future easily reconfigured for
smaller offices and shops. The fixtures can be programmed to work together within the newly defined space with a few
clicks using the GUI software.

• Vary zones of light to any scale, large or small, and change at any time without needing to switch out hardware. One
investment saves on numerous material and labor costs, presenting a superior value to facilities
• Sector combines daylighting technologies with occupancy sensing and manual control, offering a solution which
encompasses all major energy-saving technologies: occupancy sensing, dimming and switching, daylight harvesting and
manual overrides
• Ideal Applications: Newly constructed schools, college campuses, office buildings, commercial spaces, shopping malls,
airports and other commercial facilities

Lighting Control Solutions | Commercial


SOLUTION REQUIREMENTS
PRODUCT QUANTITY

Relays
43
SBCS0-L00

Sector Bus Controller


1
SBP00-00M

Sector 5-Button Switch


4
SDS00-15W

Sector Multi-Technology Ceiling Mount Occupancy Sensor


6
OSC20-MSW

Sector Photocell
2
ODC0P-0SW

www.leviton.com/les 23
BEST SOLUTION
SECTOR ZONAL LIGHTING WITH RELAY CONTROL

Sector Relay

Sector
Multi-Tech
Ceiling
Sector Sensor
Photocell

Sector
2-Button Sector
Switch 2-Button
Switch

Sector Sector
Lighting Control Solutions | Commercial

2-Button 2-Button
Sector Bus Switch
Controller Switch

Sector
5-Button
Switch
Sector
5-Button
Switch

Sector
Sector
Multi-Tech
Multi-Tech
Ceiling
Sector Ceiling
Sensor
Photocell Sensor

Sector Sector
Multi-Tech Multi-Tech
Ceiling Ceiling
Sensor Sensor

PROBLEM: Existing facility desires the flexible features of the Sector system to control overhead lighting by zones, but the
building has existing non-Sector ballasts. Replacing all ballasts would be cost-prohibitive.

SOLUTION: The Sector solution contains all of the flexibility and features of Sector into a system that can be implemented
with any 1-10V ballast or load. This makes Sector ideal for retrofit projects where ballasts already exist. Ballasts can later
be upgraded to Leviton Sector ballasts to allow for energy usage tracking. Sector relays allow the integration of the Sector
system without completing an entire overhaul of a structure’s existing ballast systems.

• Controls lighting areas by zones with the ability to add and merge zones as lighting needs evolve
• Contains all of the flexible options of Sector without requiring immediate replacement of existing ballasts
• Ideal Applications: Retrofit applications such as hotels, schools, universities, hospitals, airports, and other pre-existing
structures

24
SOLUTION REQUIREMENTS

PRODUCT QUANTITY

Sector Relay
15
SBCS0-L00

Sector Bus Controller


1
SBP00-00M

Sector 5-Button Switch


2
SDS00-15W

Sector 2-Button Switch


4
SDS00-12W

Sector Multi-Technology Ceiling Mount Occupancy Sensor


5
OSC20-MSW

Sector Photocell
2

Lighting Control Solutions | Commercial


ODC0P-0SW

www.leviton.com/les 25
VERIFEYE SUBMETERING SOLUTIONS
VerifEye Submetering Solutions enhance any application
by allowing facilities to accurately track actual energy
usage. By measuring energy usage over days, weeks and
months, trends can be identified and the effectiveness of
conservation efforts can be proven.

Implementing a submetering strategy in your facility is


simple, and with Leviton’s options, scalable to your
project’s needs. Start your solution with VerifEye
Metering Kits, which include the meter (indoor or outdoor)
and required current transformers. Make translation of
data easy with our VerifEye Communication Products and
Software Solutions, which translate data collected from
meters into user-friendly, real-time reports. Leviton helps
facilities implement a metering solution that fits any
project’s needs, regardless of size or requirements. To
learn more, visit www.leviton.com/VerifEye.
Lighting Control Solutions | Commercial

VERIFEYE METERING PHILOSOPHY


Consultative Approach Each project is tailored to each
customer’s needs - from a basic meter hardware system
to an advanced communication system that includes
BAS/BMS integration.

Open Protocol By designing open protocol products and operating systems, Leviton ensures ease of communication with
use of Leviton AMR and DAS equipment. The result is scalable, streamlined solutions that are easy to integrate with new and
existing systems.

Scalable System VerifEye solutions can be implemented as an entire solution or in stages, based on the project and the
customer’s needs for ease and flexibility. Options for future upgrades and additions are available with Leviton’s flexible
solution—no need to purchase an entire new system, adding long-term value and cost savings.

VERIFEYE SUBMETERING SOLUTIONS DELIVER ACCURATE INFORMATION FOR:


• Energy monitoring, load profiling and benchmarking
• Tenant billing and cost allocation
• Measurement and verification (M & V)
• Energy conservation and cost reduction
• Green building initiatives and government mandates
• AMR/BAS/BMS/EMS integration
• Usage aggregation
• Simple energy code compliance for Title 24 as well as LEED and Energy Star projects

See the VerifEye Submetering Solutions section for more information on product offerings.

26
www.leviton.com/les 27
SAVE ON ENERGY COSTS
Lighting energy consumption typically accounts for 38% of all energy used in today’s commercial facilities. With rising energy
costs and increased code compliance mandates, turning lights OFF in unoccupied spaces is a necessity. One of the best ways
to ensure that energy is not wasted is by installing occupancy sensors. To learn more, visit www.leviton.com/Sensors.

An E Source survey, focusing only on the addition of occupancy sensors, highlights the significant energy savings their
adoption can provide:

TYPICAL SAVINGS WITH OCCUPANCY SENSORS


Private Office
(Save 13 to 15%)

Open-Plan Office
(Save 20 to 28%)

Classroom
(Save 40 to 46%)

Conference Room
(Save 22 to 65%)
Sensing Control

Bathrooms
(Save 30 to 90%)

Corridors
(Save 30 to 80%)

Storage Area
(Save 45 to 80%)

According to a Midwest Energy Efficiency Alliance study, their cost-saving potential is considerable:

40¢ ANNUAL LIGHTING ENERGY COST ($/SQ.FT.)

-6¢ Occupancy Sensors Save 18%


(equal to 6¢ / ft2)
-8¢ Lighting Design Saves 20%
(equal to 8¢ / ft2)
-13¢ Daylight Harvesting Controls Save 35%
(equal to 13¢ / ft2)
Source: Midwest Energy Efficiency Alliance

SAVE ON MATERIAL AND LABOR COSTS


Though the energy savings from occupancy sensors remains their most compelling feature, the reduced frequency of lamp
replacement over time and the associated decline in maintenance costs can also provide significant savings. Their ease of
installation makes their use a cost effective and viable energy saving alternative in both new construction and retrofit
applications.

28
SAVE ON ENERGY CODE COMPLIANCE COSTS
Occupancy and/or vacancy sensors are an integral component of all modern energy codes. Occupancy sensors provide a
very cost-effective means of compliance. They also offer an easy way to achieve higher levels of voluntary certification for
implementation of energy saving measures, resulting in potential income tax credits for building owners or tenants who meet
these “green” standards.

ASHRAE STANDARD 90.1 2010


• Requires occupancy sensors that turn lights OFF in all buildings. All spaces must have a lighting control that is either manual-
ON or auto-ON to <50% of lighting load.
• Occupancy sensors required:
- In certain non K-12 classrooms - Conference/meeting rooms /lecture halls - Copy and print rooms
- Office spaces up to 250 square feet - Restrooms, locker and fitting rooms - Training rooms
- Employee lunch and break rooms - Storage and supply rooms between
(if no multi-scene control is in place) 50 and 1,000 sq ft
• Plug Load Controls: Section 8.4.2 allows for automatic control of 50% of all 125V, 15A and 20A receptacles serving private
offices, open spaces and computer classrooms. Receptacles shall be controlled by an automatic control device such as an
occupancy sensor.

IECC LIGHTING CONTROL PROVISIONS


• Used by government agencies to formulate requirements for minimum energy efficiency in commercial building design
• Section 805.2.2.1 allows occupancy sensors to be used in open areas as an alternative to a provision requiring manual
control that uniformly reduces lighting by at least 50%

Sensing Control
CALIFORNIA TITLE 24 2013
California Title 24 2013, Part 6, applies to nonresidential and residential high-rise buildings as well as hotel/motel occupancies.
Title 24 compliance is mandatory to legally operating and occupying buildings in California. Key provisions now in effect include:
Area Controls: An occupancy sensor that turns lights OFF within 30 minutes after the space is vacated for all areas enclosed
by ceiling height partitions
Multi-Level Lighting Controls: General lighting for any enclosed space 100 sq. ft. or larger where connected lighting load
exceeds 0.8 watts per sq. ft. for the space and has more than one light source shall have at least one control step that is
between 50% and 70% and allow the power of all lights to be manually turned OFF (Occupancy sensors that switch alternate
rows of lighting fixtures based on occupancy are a possible solution)
Shut-off Controls: For every floor, all interior lighting must have a separate automatic control – an occupancy sensor or some
other device – capable of automatically shutting off the lighting. Occupancy sensor is required for Offices ≤ 250 sq. ft.;
Multipurpose room < 1000 sq. ft.; Classrooms of any size; Conference rooms of any size. Shall allow lights to be manually shut
off regardless of sensor status.
New Single and Low-Rise Residential Structures: Bathroom, garage, laundry room, utility room and outdoor lighting in
single residences as well as lighting in common areas of low-rise residential buildings with four or more dwelling units must
be from high-efficacy luminaires. If luminaires are used in these locations that are not high efficacy, occupancy sensors must
control them. Lighting in other areas of residential buildings that is not from high-efficacy luminaires is only permitted if
controlled by either a dimmer switch or an occupancy sensor.
Demand Responsive Lighting Controls: Buildings >10,000 sq. ft. require automatic demand responsive lighting controls;
uniformly reduce lighting power consumption ≥ 15%; Exception: Non-habitable spaces and spaces <0.5w/sq. ft. Each luminaire
shall be controlled by at least one of the following:
• Manual Dimming • Automatic Daylight Controls • Demand Response Controls
Self-Contained Devices: Requirements for self-contained lighting controls include time switch controls, automatic daylight
controls, dimmer controls, occupancy, motion and vacancy sensing controls.
Receptacle Control: At least 50% of receptacles in hotel and motel guest rooms shall be automatically turned off via sensor,
captive key switches or automatic controls within 30 minutes after the space is vacated.

LEED VOLUNTARY CERTIFICATION PROGRAM


• Voluntary program developed and administered by the U.S. Green Buildings Council (USGBC)
• Four-tiered rating and certification system
• Focus on daylighting to reduce a building’s operating costs and occupancy sensors for better control of lights and HVAC systems
• LEED requires compliance with ASHRAE and as such occupancy sensors are required

For more information, visit leviton.com/cenergycodes.

www.leviton.com/les 29
ABOUT SENSING TECHNOLOGIES
Passive Infrared (PIR)
Infrared occupancy sensors are passive devices designed to detect the movement of heat-emitting bodies. They are installed
to monitor areas where there are no physical obstructions to block the sensor’s field of view.

Ultrasonic (US)
Ultrasonic sensing technology provides highly accurate small-motion detection. Leviton sensors employing ultrasonic
technology are well suited to monitoring areas, especially smaller or narrow ones, with inanimate objects (such as furniture)
that block the line of site and hence are likely to block the field of view of PIR sensors. They are also ideal where more
sensitive detection is required.

Multi-Technology
Multi-technology occupancy sensors combine ultrasonic sensing for maximum sensitivity with PIR technology to prevent
false triggers from air conditioning and corridor activity. These sensors are ideal for large, open areas including office areas
with cubicles, general workspaces, warehouse and storage facilities, cafeterias, and public areas in commercial facilities.

Adaptive Definition
A dedicated internal microprocessor continually analyzes the room environment and adjusts itself automatically. The internal
timer, detection sensitivity and thresholds are automatically adjusted. Once installed, a sensor incorporating adaptive
technology should not require manual adjustment or calibration.

OCCUPANCY SENSOR INSTALLATION TYPES AND TIPS


Passive Infrared (PIR) Occupancy Sensors
• Use a semiconductor to sense movement of infrared heat from the
Sensing Control

human body
• Require an unobstructed line-of-sight for accurate detection—any
furniture or decorations that block the sensor’s view will prevent
occupant’s movement from being “seen”
• Respond to larger movements than ultrasonic sensors
• Work best in small, enclosed areas with high levels of occupant motion
• Locate PIR sensors with a clear line-of-view of the area to be covered,
perpendicular to the likely movement

Ultransonic (U/S) Occupancy Sensors


• Continually transmit ultrasonic sound waves and respond to shifts in
position of a person relative to the sensor (doppler shift), and do not
require an unobstructed line-of-sight
• More effective at sensing motion around corners and in cubicles, and
locations where only small amounts of motion are taking place
• Since U/S sensors are omni-directional, locate sensors away from
doorways, room openings or adjacent areas, or closer than 6 feet of
HVAC ducts to avoid unwanted sensing of motion
• Carpeting, partitions and ceiling tiles will absorb U/S waves and reduce
range, while hard surfaces such as tile or metal will increase sensitivity
• Most effective when mounted at a height of 8 feet or lower

Multi-Technology Occupancy Sensors


• Combine PIR and U/S technology to provide the most reliable
detection means possible, with PIR’s long-range detection and U/S
high sensitivity
• Must be located with an unobstructed line-of-sight view of a room’s
entrance
• Must be located at least 6 feet from HVAC ducts
• Locate where small-motion work occurs, such as desks and
workstations

30
ABOUT DIFFERENT SENSOR DESIGNS
Sensor Type When to Use
Wall Switch This sensor replaces an existing wall switch. Get both occupancy sensing and manual on/off
switching in a single device.

Ceiling-Mount For 180° or 360° coverage of an area (360° sensor shown).

Wall-Mount For coverage of irregularly shaped areas and those with varying ceiling heights, as well as
narrow hallway and high-bay corridor applications. For detection in spaces outside the field of
view of other occupancy Adjustable swivel neck rotates 80° vertically and 60° horizontally to
allow wall or ceiling mount installation.

Fixture-Mount For mounting on or in fixtures.

Sensing Control
SELECTION & PLACEMENT
Sensors can be mounted in the middle of walls, in corners, or on ceilings. Occupancy sensors must be intelligently placed in
order to ensure that motion is detected throughout an entire space. With a variety of models from which to choose, care
should be taken to select the proper combination of sensors to cover an entire area with motion detection.

Factors to consider before selecting and placing an occupancy sensor include:


• Size and shape of area needing coverage compared to ranges of occupancy sensors
• Obstacles that may block the sensor’s line of sight • How much activity there is in a space • Ceiling height
• Airflow that can falsely register as motion • Location of HVAC ducts

OCCUPANCY LAYOUT SERVICES


Leviton’s Lighting and Energy Solutions team provides a complimentary occupancy sensor layout service. This service
provides suggested sensor selection and placement on a customer’s drawings in either paper or electronic form, along
with a bill of material detailing the components necessary for that layout. Register for this complimentary service at
portal.leviton.com.

UNDERSTANDING SENSOR CATALOG NUMBERS


First 2 Letters 3rd Character: Last 2 Characters – 1st Character of Suffix: 2nd Character of 3rd Character of
type of product sensor technology Suffix: voltage Suffix: color
OS = Occupancy C = Ceiling Mount 02 = 200SF or 2A F = 10 min delayed-OFF for 2nd relay 1 = 120V W = White
Sensor W = Wall Mount 04 = 400SF or 4A G = Neutral not required 2 = 230V I = Ivory
OD = Occupancy P = Power Pack 05 = 500SF or 5A I = Infrared 3 = 347V T = Light Almond
Detector A = Add-A-Relay 10 = 1000SF or 10A M = Multi-technology 4 = 480V G = Gray
WS = Wireless S = Switch Mount 12 = 1200SF or 12A R = Relay (HVAC) 7 = 277V E = Ebony/Black
Sensor F = Fixture Mount 15 = 1500SF or 15A P = Self-powered 8 = 240V R = Red
D = Dimmer 20 = 2000SF or 20A T = CA Title 24 Compliant, 2nd Relay D = 120-277V 0 = N/A
G = Plug 0D = Dual relay U = Ultrasonic U = Universal
R = Room Controller 0S = Self-contained 0 = N/A N = NAFTA/
0 = N/A CG = Cage Q = Auto ON/Auto OFF Only Buy America*
V = Vacancy HU = High Bay 0 = N/A
LR = Long Range
MD = Multi-Tech
Dual Relay
MT = Multi-Tech
Single Relay
RA = Raceway
Adapter
WV = Wide View *Contact Leviton for NAFTA/Buy America compliant occupancy sensors.

www.leviton.com/les 31
WIRELESS SELF-POWERED SENSORS
LevNet RF 902 MHz Wireless Self-Powered Sensors are part of LevNet RF’s complete
line of wireless self-powered solutions. The occupancy sensors have built-in solar
cells that draw on available ambient light within a space to power themselves and can
operate for up to 48 hours in total darkness. The self-powered sensor design also
overcomes the placement and coverage challenges of traditional sensors.
Self-powered sensors enable flexible placement, allowing sensors to be mounted
wherever needed without the complexity of moving or installing new wiring.

SPECIFICATIONS & FEATURES


• Zero Power Consumption: Solar power provides the energy to keep the device on and sensor technology turns the lights
off, eliminating additional expenses to the end user’s energy bill
• Zero External Power Required: With no power wire limitations, this enables the installer to place the sensor in the optimal
location of any application to capture minor motion and reduce false OFFs
• Switching Control of LED drivers
• No Additional Wiring: Self-powered wireless technology eliminates the need to pull additional wire making installation
quick and easy and increasing labor savings with little to no impact to business during conversion
• Advanced Field-of-View: Superior detection for parallel and perpendicular motion; innovative technology detects motion
Sensing Control | Wireless Self-Powered

moving directly towards the sensor; 360° rotation to fine tune location of solar cells and field-of-view for the most accurate
sensing possible

IDEAL APPLICATIONS
• Retrofits, new construction, restrooms, conference rooms, classrooms, private/executive offices, retail spaces

TESTING & CODE COMPLIANCE


• CA Title 24 /ASHRAE 90.1 Compliant
• FCC Certified for wireless communication
• Backed by a limited five-year warranty

LEVNET RF 902 MHZ WIRELESS SELF-POWERED OCCUPANCY SENSORS


COMMERCIAL GRADE
DESCRIPTION CAT. NO. COVERAGE COLOR
LevNet RF 902 MHz Low Profile Self-Powered PIR Surface Mount WSC12-M9N 360°, 1,200SF
Occupancy Sensor White
LevNet RF 902 MHz Self-Powered PIR Wall Mount Occupancy Sensor WSWDR-H9W 180°, 1600SF*
NOTE: For more information on LevNet RF, see the LevNet RF Wireless Self-Powered Solutions section (pages 59-68)
*Multiple lenses included, see data sheet for more coverage information

TOP VIEW
15
LONG RANGE
Top View
10 77°

22 ft (6.7 m) 21.5° 14°


6.5°
0 11 ft (3.4 m) 27°
0 Center
Line
11 ft (3.4 m)
10
22 ft (6.7 m)

3 ft 7 ft 25 ft 35 ft 100 ft 150 ft
(1 m) (2.2 m) (7.6 m) (10.7 m) (30.48 m) (45.7 m)
15

Minor Motion
SIDE VIEW
Side View
Major Motion
10 6-8 ft
(2.1 -2.4 m)

0 3 ft 7 ft 25 ft 35 ft 100 ft 150 ft
16 14 11 9 4 3 0 3 4 9 11 14 16 (1 m) (2.2 m) (7.6 m) (10.7 m) (30.48 m) (45.7 m)

WSC12 Field of View (in feet) WSWDR Field of View (in feet)

32
DECORA® WALL SWITCH OCCUPANCY SENSORS
Convenient switch and occupancy sensor combo utilizes Decora® wallplates for sleek aesthetics. Advanced passive infrared
technology provides highly accurate monitoring in a variety of commercial and residential applications. The OSSMD and
OSSMT multi-technology unit combines passive infrared and ultrasonic technologies to provide maximum sensitivity with
immunity to false triggering.

Robust latching
Exclusive dual PIR
mechanical relay
sensors detect IR
signal

Patented adjustable
blinders block
peripheral signals

Vandal-resistant Fresnel
lens for optimal
field of view

Sensing Control | Wall Switch


Additional Features
Exclusive self-adjusting
feature on Time, range and
select models light adjustments

Exclusive Leviton Photocell detects light


High Inrush to enable energy-saving
Circuitry (H.I.S.) ambient light override
Zero crossing point
ensures maximum Ground clip to ensure
contact life solid connection

LED indicator flashes Push button


when sensor for manual on/off
detects motion

TESTING & CODE COMPLIANCE


• UL and cUL Listed (ODS10, ODS15, ODS0D-ID, OSSNL OSSMT-MD, MDS10 and MDS15)
• ETL and cETL Listed to UL 508 and CSA C22.2 No. 14 (OSSMT-GD and OSSMD-MD)
• CA Title 20/24 compliant (ODSXX-, and OSSMX models) and meets ASHRAE Standard 90.1 2010 requirements
• Backed by a limited five-year warranty

www.leviton.com/les 33
DECORA PIR WALL SWITCH OCCUPANCY AND VACANCY SENSORS
COMMERCIAL GRADE+
DESCRIPTION CAT. NO. RATING COVERAGE COLOR*
ODS06-ID Incandescent: 600W @ 120V. LED Fluorescent: 800VA @
Decora PIR Wall Switch Occupancy Sensor W, I
ODS06-IN 120V, 1500VA @ 277V. 50/60Hz, Motor: 1/4 HP @ 120V
Decora PIR Wall Switch Occupancy Sensor Incandescent: 3470W @ 347V. LED Fluorescent: 3470W @
ODS10-I3 W
347V Only Model 347V. 50/60Hz, Motor: 1/4HP @ 347V
W, I, T,
Decora PIR Wall Switch Occupancy Sensor ODS10-ID
G, E, R
Decora PIR Wall Switch Vacancy Sensor ODS10-TD Incandescent: 800W @ 120V. W, I, T
LED Fluorescent: 1200VA @ 120V, 2700VA @ 277V.
Decora PIR Wall Switch Occupancy Sensor- Auto-ON/ For 50/ 60Hz AC only.
ODS10-IQ W, I, E
Auto-OFF Only Model Motor: 1/4HP @ 120V
Decora PIR Wall Switch Occupancy Sensor with
MDS10-ID
Self-Adpative Technology - Lev-Lok Model W, I, T,
Decora PIR Wall Switch Occupancy Sensor 180°, G, E
ODS15-ID
with Self-Adaptive Technology 2100SF
Incandescent: 1800W @ 120V.
Decora PIR Wall Switch Occupancy Sensor with LED Fluorescent: 1800VA @ 120V, 4000VA @ 277V.
ODS15-TD W, I, T
Self-Adaptive Technology - Vacancy Model 50/60Hz.
Motor: 1/4HP @ 120V
Decora PIR Wall Switch Occupancy Sensor with W, I, T,
MDS15-ID
Self-Adaptive Technology - Lev-Lok Model G, E
Sensing Control | Wall Switch

Decora Dual-Relay PIR Wall Switch Occupancy Sensor Primary Relay– LED Fluorescent: 1200VA @ 120V,
with Self-Adaptive Technology. 2700VA @ 277V; Incandescent: 800W @ 120V. W, I, T,
ODS0D-ID
Default setting = Conference Room mode, Secondary Relay– LED Fluorescent: 800VA @ 120V, G, E, R
alternate setting = Classroom mode** 1200VA @ 277V; Incandescent: 800W @ 120V. 50/60Hz.
Incandescent: 800W @ 120V. W, I, T,
Decora PIR Wall Switch with LED Night Light OSSNL-ID
LED Fluorescent: 1200VA @ 120V, 2700VA @ 277V. G, E
Decora PIR Wall Switch with LED Night Light, CA Title 50/60Hz.
OSS10-IN W, I, E
24 - Vacancy Model Motor: 1/8 HP @ 120V
Protective Cage for Wall Switch Sensors OSWWG-POW — — W

RESIDENTIAL GRADE
DESCRIPTION CAT. NO. RATING COVERAGE COLOR*
Decora PIR Wall Switch Vacancy Sensor, Single-Pole IPV02-1L 300W Incandescent/FL Ballast, 150W LED/CFL, W,T
Decora PIR Wall Switch Occupancy Sensor, Single-Pole IPS02-1L 1/6 HP Motor, 2.5Amp Resistive W, I, T
Decora PIR Wall Switch Vacancy Sensor, Single-Pole IPV05-1L 600W Incandescent/LED FL Ballast, 150W LED/CFL,
Z
Decora PIR Wall Switch Occupancy Sensor, Single-Pole IPS05-1L 1/6HP Motor, 5A Resistive
180°,
Decora PIR Wall Switch Occupancy Sensor, Single-Pole
IPS06-1L 600W Incandescent, 150W LED 900SF W
or 3-Way
Decora PIR Wall Switch Dimming Vacancy Sensor,
IPVD6-1L
Single-Pole or 3-Way
600W Incandescent, 150W LED/CFL
Decora PIR Wall Switch Dimming Occupancy Sensor,
IPSD6-1L
Single-Pole or 3-Way
Decora Wall Switch Relay Vacancy Sensor, Single-Pole 180°,
IPV15-1L Z
or 3-Way 1800W Incandescent, 600W LED/CFL, 900SF,
Decora Wall Switch Relay Occupancy Sensor, 1800VA Fluorescent Ballast, 1/2 HP neutral
IPS15-1L required
Single-Pole, 3-Way
Decora Sensor Remote, 120VAC, Manual-ON, Auto-OFF,
IPVOR-1L — —
For use with IPS15 or IPV15 Sensor

DECORA RESIDENTIAL GRADE WALL SWITCH HUMIDITY SENSOR AND FAN CONTROL
DESCRIPTION CAT. NO. RATING COLOR*
600W Incandescent, 150W LED/CFL400VA MLV/Fluorescent,
Humidity Sensor & Fan Control IPHS5-1L W, I, T
1/6 HP (3A) Fan

Z — Comes packaged with three colors: White, Ivory and Light Almond.

34
DECORA MULTI-TECHNOLOGY WALL SWITCH OCCUPANCY AND VACANCY SENSORS
COMMERCIAL GRADE+
DESCRIPTION CAT. NO. RATING COVERAGE COLOR*
Incandescent/Tungsten: 800W @ 120V.
Decora Multi-Technology Wall Switch W, I, T, G,
OSSMT-MD LED Fluorescent: 1200VA @ 120V, 2700VA @ 277V.
Occupancy Sensor with Self-adaptive Technology E, R
Motor: 1/4HP @ 120V, 50/60 Hz
Incandescent/Tungsten: 800W @ 120V.
Decora Multi-Technology Wall Switch Sensor -
OSSMT-TM LED Fluorescent: 1200VA @ 120V, 2700VA @ 277V. W, I, T
Vacancy Model
Motor: 1/4HP @ 120V, 50/60 Hz
Incandescent/Tungsten: 800W @ 120V.
Decora Multi-Technology Wall Switch
OSSMT-MQ LED Fluorescent: 1200VA @ 120V, 2700VA @ 277V. W, I, E
Occupancy Sensor - Auto-ON/Auto-OFF Only Model
Motor: 1/4HP @ 120V, 50/60 Hz
Incandescent/Tungsten: 800W @ 120V.
Decora Multi-Technology Wall Switch Occupancy
OSSMT-M3 LED Fluorescent: 1200VA @ 120V, 2700VA @ 277V, W, I
Sensor - 347V Only Model
1500VA @347V. Motor: 1/4HP @ 120V.
Decora Multi-Technology Wall Switch Occupancy W, I, T, G,
OSSMT-GD
Sensor. No neutral wire required for installation. 180°, E, R
Incandescent/Tungsten: 800W @ 120V. 2400SF
Decora Multi-Technology Wall Switch Sensor with No
OSSMT-GT LED Fluorescent: 1200VA @ 120V, 2700VA @ 277V. W, I, T
Neutral - Vacancy Model
Motor: 1/4HP @ 120V, 50/60 Hz
Decora Multi-Technology Wall Switch Occupancy
OSSMT-GQ W, I, E
Sensor with No Neutral -Auto-ON/Auto-OFF Only Model

Sensing Control | Wall Switch


Incandescent/Tungsten: 800W @ 120V.
Decora Multi-Technology Wall Switch Occupancy
MSSMT-GD LED Fluorescent: 1200VA @ 120V, 2700VA @ 277V.
Sensor with No Neutral -Lev-Lok Model
60 Hz. Motor: 1/4HP @ 120V.
Decora Dual-Relay Multi-Technology Wall Switch Primary Relay:
OSSMD-MD W, I, T,
Occupancy Sensor with Self-Adaptive Technology LED Fluorescent: 1200VA @ 120V, 2700VA @ 277V.
Incandescent: 800W @ 120V. G, E
Decora Dual-Relay Multi-Technology Wall Switch Secondary Relay:
Occupancy Sensor with Self-Adaptive Technology. OSSMD-GD LED Fluorescent: 800VA @ 120V, 1200VA @ 277V.
No neutral wire required for installation. Incandescent: 800W @ 120V.
Motor: 1/4HP @ 120V, 50/60 Hz
Protective Cage for Wall Switch Sensors OSWWG-POW — — W
* Add to end of catalog number suffix for color of switch: White (W), Ivory (I), Light Almond (T), Gray (G), Ebony (E) and Red (R) available on select models.
Wallplates sold separately.
** In Conference Room Mode, both primary and secondary relays respond to ambient light override. In Classroom Mode, primary relay responds only to ambient
light override.
+ Consult with factory for 208, 220, 230 and 240V models.

www.leviton.com/les 35
DECORA WALL SWITCH VACANCY & OCCUPANCY SENSORS DIMENSIONS

1.35
(33.6)

2.66
4.11 (67.5)
(104.4)

1.75
(44.5)

ODS10-ID/ ODS10-TD/ODS10-IQ/MDS10-ID/ ODS0D-ID OSSNL-ID /OSS10-IN


ODS15-ID /ODS15-TD/MDS15-ID Shown with Night Light ON
Sensing Control | Wall Switch

1.35
(33.6)

2.66
4.11 (67.5)
(104.4)

1.75
(44.5)
OSSMT-MD/OSSMT-GD/OSSMT-GT/ OSSMD-MD
OSSMT-GQ, MSSMT-GD Multi-Tech Dual Relay Sensor
Multi-Technology Sensor

1.75 1.75 1.75


(44.5) (44.5) (44.5)

2.72 2.72
2.72 4.13
4.13 (69) (69)
4.13 (69) (104.8)
(104.8) (104.8)

1.75 1.75
1.75
(44.5) (44.5)
(44.5)

IPS02, IPV02, IPS05, IPV05, IPSD6, IPV06 IPHS5


IPS06, IPS15, IPV15

36
DECORA WALL SWITCH VACANCY & OCCUPANCY SENSOR FIELDS OF VIEW
TOP VIEW TOP VIEW TOP VIEW

40 30 15

30 20
6

15 0
0

6
0

20
15
15 SIDE VIEW
30
SIDE VIEW 5
5 4
4
0 0
30 0 8 15 27 30
Major Motion, IR 0 20 40
Minor Motion, IR
40
Major Motion, PIR Major Motion, U/S
SIDE VIEW
5 Major Motion, PIR Major Motion, U/S
4
0
0 15 40
Minor Motion = Dual Technology coverage. This also represents the IPSD6/IPVD6,
maximum ultrasonic range coverage.
OSSXX-ID/ODSXX-ID IPS02/IPV02/IPS05/IPV05,
Field of View (in feet)
ODSXX-ID OSSMT Field of View (in feet) IPS06, IPS15/IPV15 (in feet)

Sensing Control | Wall Switch


TOP VIEW TOP VIEW
8’
15’
6’

4’
10’
2’
6’ 0’

2'

0’ 4'

6'
6’ 8'

10’ 10' SIDE VIEW

0’
15’
2'
7 SIDE VIEW
4'
4
6'
0
8'
0 5 8 15 27 30 10' 8' 6' 4' 2' 0' 2' 4' 6' 8' 10'

IPHS5-1L Field-of-View  OSF10 Field of View


IPHS5-1L Field-of-View (in feet)

TOP VIEW TOP VIEW TOP VIEW

30
30 30

20
20 20

10 10 10

0 0 0

10 10 10

20 20
20

30 30
30

SIDE VIEW SIDE VIEW


0 SIDE VIEW 0
0
S S
H H
E E
20 20 L L
V V
15 E E
30 30 S S
20
40 30 20 10 0 10 20 30 40
30 20 10 0 10 20 30 30 20 10 0 10 20 30

360° High-Bay 360° Low-Bay Aisle Mask


(White lens) (Blue lens)
OSFHU Field of View (in feet)

www.leviton.com/les 37
PROVOLT SELF-CONTAINED SENSORS — DAYLIGHT HARVESTING CAPABLE MODELS
The Leviton Provolt Series of Occupancy Sensors features self-contained line-voltage occupancy sensors and photocells in
one unit. The integrated design alleviates the need for separate power pack, occupancy sensor, and photocell wiring making
it a low-cost and efficient energy management solution for new construction and retrofits. For true daylight harvesting
applications, integrated photocells provide consistent daylight design levels by actively switching the connected load(s)
ON and OFF in response to available natural light to maximize energy savings. The Provolt Series also includes a line of
vacancy sensors that features selfcontained line-voltage vacancy sensing technology.

FEATURES • Industry-exclusive High Inrush Stability (H.I.S.) technology


• Includes occupancy sensing, daylight harvesting, and for unmatched durability and service
manual-ON/auto-OFF override control in a single unit • Mechanically held 10A latching relay provides
• Provides additional energy savings with true daylight dependability and robust performance for all load types
harvesting capabilities • Zero-crossing circuitry for extended life of the relay
- Occupancy sensor models include an angled light pipe • Simplified commissioning
and flat light pipe for open loop and closed loop • Visual LED status indicators
daylight harvesting applications
• Lenses are easily replaceable and color-coded for
- Auto-Calibration – photocell intelligently measures light contractors and end-users to easily identify lenses from
levels to determine optimal daylight design levels for the ground:
closed loop applications
Sensing Control | Self-Contained

- Mid-Range: Red — included with multi-technology and


• Switching Control of LED drivers PIR models
• Dual Relay Modes Include: - High Density: Blue
- Fan Control - Extended Range: Black
- Auto ON/Manual ON • Integrated photocell tested to less than 1 FC accuracy
- Stairwell Control • Easy installation into junction boxes with Leviton
- Step Dimming - Alternating Daylighting Levels exclusive screw guides, coasters and terminal blocks
- Step Dimming - Load 1 Primary • Tested to exceed 2 million switching cycles under
• Auto-adapting - time delay and sensitivity are continually standard loads
adjusted to room occupancy pattern • Passed rigorous NEMA410 testing for electronic ballast
• Output short circuit protection - protection against low rating
voltage wiring errors
• BMS input/emergency override TESTING & CODE COMPLIANCE
• Industry-exclusive self-configuring local manual switch • CA Title 24 Compliant, UL773A (Occupancy Standard),
input supports momentary and maintained switches — UL924 (Emergency Equipment), cUL Listed, CE Compliant,
no special control stations required NOM Certified, RoHS Compliant, NY LLC48 Compliant
• Industry-exclusive “fail-safe” circuitry assures lights ON
to meet life safety requirements

PROVOLT SELF-CONTAINED CEILING-MOUNT OCCUPANCY SENSORS —


DAYLIGHT HARVESTING CAPABLE
DESCRIPTION CAT. NO. COVERAGE COLOR INPUT VOLTAGE, RATING
Provolt Line Voltage Ceiling Mount PIR Occupancy Sensor ODC04-IDW 120V, 50/60Hz
450SF,
w/Integrated Photocell, High-Density Lens installed, O2C04-IDW 8A, Electronic Ballast,
120-277V
Mid-Range Lens included (Dual Relay) 800W/VA, Tungsten Ballast,
Provolt Line Voltage Ceiling Mount PIR Occupancy Sensor ODC15-IDW 1/4 HP Motor
1500SF,
w/Integrated Photocell, Extended Range Lens installed, O2C15-IDW
120-277V 230V, 50Hz
Mid-Range Lens included (Dual Relay)
W 6A/6AX, Electronic Ballast,
Provolt Line Voltage Ceiling Mount U/S Occupancy ODC05-UDW Magnetic Ballast,
500SF,
Sensor w/Integrated Photocell, Extended Range Lens O2C05-UDW 1200W/VA, 1/3 HP Motor
120-277V
installed (Dual Relay)
Provolt Line Voltage Ceiling Mount U/S Occupancy ODC10-UDW 230V, 50Hz
1000SF, 6A, Electronic Ballast,
Sensor w/Integrated Photocell, Extended Range Lens O2C10-UDW
120-277V 1200VA, 1/3 HP Motor
installed (Dual Relay)

38
PROVOLT SELF-CONTAINED CEILING MOUNT OCCUPANCY SENSORS —
DAYLIGHT HARVESTING CAPABLE
DESCRIPTION CAT. NO. COVERAGE COLOR INPUT VOLTAGE, RATING
Provolt Line Voltage Ceiling Mount U/S Occupancy ODC20-UDW 277V, 50/60Hz
2000SF,
Sensor w/Integrated Photocell, Extended Range O2C20-UDW 5A, Electronic Ballast,
120-277V
Lens installed (Dual Relay) 800W/VA, Tungsten Ballast,
Provolt Line Voltage Ceiling Mount Multi-Technology ODC05-MDW 1/3 HP Motor
500SF,
Occupancy Sensor w/Integrated Photocell, Extended O2C05-MDW
120-277V 230V, 50Hz
Range Lens installed (Dual Relay)
W 6A/6AX, Electronic Ballast,
Provolt Line Voltage Ceiling Mount Multi-Technology ODC10-MDW
1000SF, Magnetic Ballast, 1200W/VA,
Occupancy Sensor w/Integrated Photocell, Extended O2C10-MDW
120-277V 1/3 HP Motor
Range Lens installed, Mid-Range Lens included (Dual Relay)
Provolt Line Voltage Ceiling Mount Multi-Technology ODC20-MDW 277V, 50/60Hz
2000SF,
Occupancy Sensor w/Integrated Photocell, Extended O2C20-MDW 5A, Electronic Ballast,
120-277V
Range Lens installed, Mid-Range Lens included (Dual Relay) 1200VA, 1/3 HP Motor

Sensing Control | Self-Contained


PROVOLT SELF-CONTAINED CEILING-MOUNT VACANCY SENSORS
DESCRIPTION CAT. NO. COVERAGE COLOR INPUT VOLTAGE, RATING
120V, 50/60Hz
O3C15-IDW
1500SF, 8A, Electronic Ballast,
Provolt Line Voltage Ceiling Mount PIR Vacancy Sensor 04C15-IDW
120-277V 800W/VA, Tungsten Ballast,
(Dual Relay)
1/4 HP Motor

O3C10-MDW 230V, 50Hz


Provolt Line Voltage Multi-Technology Ceiling Mount 1000SF,
04C10-IDW W 6A/6AX, Electronic Ballast,
Vacancy Sensor 120-277V
(Dual Relay) Magnetic Ballast, 1200W/VA,
1/3 HP Motor
O3C20-MDW
Provolt Line Voltage Multi-Technology Ceiling Mount 2000SF, 277V, 50/60Hz
04C20-IDW
Vacancy Sensor 120-277V 5A, Electronic Ballast,
(Dual Relay)
1200VA, 1/3 HP Motor

Angled Light Pipe

ODC20-MDW

Flat Light Pipe


ODC20-MDW (top view)

www.leviton.com/les 39
FIELD OF VIEW FOR PROVOLT SELF-CONTAINED CEILING-MOUNT SENSORS
PROVOLT SERIES INFRARED SENSORS
TOP VIEW TOP VIEW TOP VIEW
15
20
12

10

10
5 5

0
0 0

5
10
10

15
12 SIDE VIEW
20

SIDE VIEW Minor Motion, Infrared 20

12 Major Motion, Infrared


SIDE VIEW
12

0
12 9 7 5 3 0 3 5 7 9 12 20 15 11 9 5.6 3 0 3 5.6 9 11 15 20 30 25 20 15 10 5 0 5 10 15 20 25 30

ODC04-IDW, O2C04-IDW ODC15-IDW, O3C15-IDW, Mid-Range Lens — Mounting up to


(High Density: Blue Lens) O2C15-IDW, O4C15-IDW 20 feet (Included with all PIR and
(Extended Range: Black Lens) Multi-Tech Models)
Sensing Control | Self-Contained

PROVOLT SERIES ULTRASONIC SENSORS

TOP VIEW TOP VIEW

11.5
11.5
8.5
8.5

8.5

11.5
8.5

11.5

Minor Motion, Ultrasonic


Minor Motion, Ultrasonic Major Motion, Ultrasonic
Major Motion, Ultrasonic

5 0 10 20 0
17 23 23 17 17 23

ODC05-UDW, O2C05-UDW ODC10-UDW, O2C10-UDW

TOP VIEW

16

11.5

11.5

16

Minor Motion, Ultrasonic


Major Motion, Ultrasonic

0
32 22.5 22.5 32

ODC20-UDW, O2C20-UDW

40
FIELD OF VIEW FOR PROVOLT SELF-CONTAINED CEILING-MOUNT SENSORS
PROVOLT SERIES MULTI-TECHNOLOGY SENSORS

TOP VIEW
20

TOP VIEW
11.5 20

8.5
11.5
8.5

0
0

8.5 8.5
11.5 11.5

Major Motion, IR 20 Major Motion, IR


20
SIDE VIEW Minor Motion, Ultrasonic
8 Minor Motion, Ultrasonic SIDE VIEW
8 Major Motion, Ultrasonic
Major Motion, Ultrasonic

0 0
0 3 5.6 9 11 15 20 23
20
17
15 11 9 5.6 3 0 3 5.6 9 11 15
17
20
23
17 23

Sensing Control | Self-Contained


ODC05-MDW, O2C05-MDW ODC10-MDW, O3C10-MDW,
(High Density: Blue Lens) O2C10-MDW, O4C10-MDW
(Extended Range: Black Lens)

TOP VIEW
15

TOP VIEW
10
20
16
5
11.5

0
5

11.5 10

8.5
15
20 SIDE VIEW
Major Motion, IR
20
Minor Motion, Ultrasonic
SIDE VIEW Major Motion, Ultrasonic
8

0
20 15 11 9 5.5 3 0 3 5.5 9 11 15 20
32 22.5 22.5 32
30 25 20 15 10 5 0 5 10 15 20 25 30

ODC20-MDW, O3C20-MDW, Multi-Range Lens — Mounting up to 20 feet


O2C20-MDW, O4C20-MDW (Included with all PIR and Multi-Tech Models)

www.leviton.com/les 41
SELF-CONTAINED OCCUPANCY SENSORS
SPECIFICATIONS & FEATURES
• Sensor and switching relay combined in a single, self-contained unit—no control
unit (power pack) required
• Switching control of LED drivers
• Ambient light override option prevents lights from turning on when there is ample
natural light
• ODC and ODW Power Base Combo Sensors combine sensors with the OPB15
Power Base Adaptor to convert low voltage sensors into self-contained line
voltage sensors for immediate energy savings
• Adjustable delayed-OFF-time settings from 20 seconds (for test mode) to
15 minutes
• Small, unobtrusive self-contained unit
Ideal Uses
• Storage areas, small bathrooms, copy rooms, and a variety of small spaces ODC0S-I1W
without wall switches

TESTING & CODE COMPLIANCE


Sensing Control | Self-Contained

• UL/cUL Listed
• CA Title 24 compliant and meets ASHRAE Standard 90.1 2010 requirements
• Backed by a limited five-year warranty

SELF-CONTAINED PIR CEILING MOUNT OCCUPANCY SENSORS


COMMERCIAL GRADE
DESCRIPTION CAT NO. RATING COVERAGE COLOR
Incandescent: 1000W
Self-Contained PIR Ceiling @120V. LED Fluorescent:
Mount Occupancy Sensor ODC0S-I1W 1000VA @ 120V.
and Switching Relay, 120V Motor: 1HP @ 120V.
For 50/60Hz
Incandescent: 1000W
Self-Contained PIR Ceiling 360°, 530SF* White
@220V. LED Fluorescent:
Mount Occupancy Sensor ODC0S-I2W
500VA @ 220V.
and Switching Relay, 220V
For 50Hz AC only
Self-Contained PIR Ceiling
LED Fluorescent: 2700VA
Mount Occupancy Sensor ODC0S-I7W
@277V. For 50/60Hz
and Switching Relay, 277V
Protective Cage for
ODCCG-000 - - -
Ceiling Mount Sensors
*When surface mounted on standard, 8-foot ceiling.

ODC0S-I Field of View (in feet)

42
LINE VOLTAGE SENSORS WITH FACTORY INSTALLED OPB15 POWER BASE ADAPTOR
5.0
TESTING & CODE COMPLIANCE (127)
• UL/cUL Listed
• CA Title 24 compliant and meets ASHRAE Standard 90.1 2010 requirements
• ARRA Compliant
• Backed by a limited five-year warranty
5.50
(139.7)
LINE VOLTAGE WALL MOUNT SENSORS
COMMERCIAL GRADE
DESCRIPTION CAT NO. RATING COVERAGE COLOR ODWxx
Line Voltage Wall Mount
Multi-Technology
ODW12-MDW 1200SF 2.80
Occupancy Sensor with
(71.1)
Power Base Combo
Line Voltage Wall Mount
PIR Wide View
ODWWV-IDW 115°, 2500SF
Occupancy Sensor with 15A, 120V Incandescent;
Power Base Combo 15A, 277V Fluorescent
White
Ballast; Motor: 3/4 HP @

Sensing Control | Line Voltage


Line Voltage Wall Mount
PIR Wide View 120V, 277V @ 2HP 55ft.,7ft. side
ODWHB-IDW
Occupancy Sensor with @30ft. high
Power Base Combo
Line Voltage Wall Mount
PIR Long Range 100ft., 110°
ODWLR-IDW
Occupancy Sensor with @ 10ft. high
Power Base Combo

www.leviton.com/les 43
SELF-CONTAINED PIR FIXTURE-MOUNT HIGH-BAY & INTEGRAL LUMINAIRE OCCUPANCY SENSORS
SPECIFICATIONS & FEATURES
PIR Fixture-Mount High-Bay Occupancy Sensor
• Universal unit includes interchangeable lenses for 360° high-bay and 360° low bay at no additional cost
• Cold storage models for applications as low as -40° F and 480V models available in non-neutral versions
• Switching control of LED drivers
• Mounts directly to industrial-style fluorescent luminaires or electrical junction box
• Self-contained PIR sensor and relay turn individual fixtures ON/OFF based on occupancy
• Up to 40 ft mounting height for quick and easy installation 42” leads included
• Relay uses zero-crossing circuitry for enhanced reliability and long-life operation
• Bright green LED status indicator blinks to signify that the sensor is functioning properly
• Delayed-OFF time adjustment from 30 sec to 20 min OSFHU
• Offset Adaptor Accessory snaps into 1/2" knockout to position sensor below fixture body for improved
field of view with deep-body fixtures
Infrared Fixture Mount Integral Luminaire Occupancy Sensor
• Easy installation with longer 21” leads allows for easy connection to any ballast eliminating the need to splice
additional wiring
• Integrated photocell prevents lights from turning ON when room is illuminated by natural light for maximum energy savings
• 8’ to 10’ mounting heights
• Adjustable Time Delay and Light Level dials located on sensor housing for easy access
Sensing Control | Line Voltage

Ideal Uses:
• OSFHU: Commercial facilities with high ceilings, including warehouses, manufacturing, cold storage, and others.
• OSF10: Task lighting, cabinet lighting, cubicles, small bathroom lighting.

TESTING & CODE COMPLIANCE


• UL/cUL Listed • CA Title 24 compliant
• Backed by a limited five-year warranty

OSF10
COMMERCIAL GRADE†
DESCRIPTION CAT. NO. RATING COVERAGE
Fluorescent: 800VA @ 120V,
OSFHU-ITW (120-230-277-347V)
Fixture Mount High-Bay PIR Occupancy 1200VA @ 277V, 1500VA @ 347V,
OSFHU-CTW (cold storage)
Sensor with Two Interchangeable Lenses 2400VA @ 480V (OSFHU-x4W
OSFHU-I4W (480V)
for 360° High-Bay, 360° Low Bay models only). 50/60Hz.
OSFHU-C4W (cold storage)
Motor: 1/4 HP @ 120V
Fixture Mount High-Bay PIR Occupancy 360° high-bay lens - 2:1 spacing
Input: 20mA, Output: 120mA,
Sensor with Two Interchangeable Lenses OSFHP-ILW (24V) to mounting height under 20 ft.
HVAC: 1A, 30VDC
and Light Sensor, Low Voltage and 1.5:1 spacing to mounting
OSFHP-ITW (120-230-277-347V) height @ 40 ft 360° low-bay lens
Fixture Mount High-Bay PIR Occupancy OSFHP-I4W (240-480V) - 2:1 spacing to mounting height
Sensor with Two Interchangeable Lenses Dual Relay: Fluorescent: 800VA @ 120V, @ 8 ft. to 20 ft.
and Light Sensor OSFHD-ITW (120-230-277-347V) 1000VA @ 230VAC, 1200VA @
OSFHD-CTW (cold storage) 277VAC, 1500VA @ 347VAC,
2000VA @ 480VAC, 50/60Hz.
Fixture Mount High-Bay PIR Occupancy Motor: 1/4 HP @ 120V
OSFHD-IAW (120-230-277-347V)
Sensor with Two Interchangeable Lenses
OSFHD-CAW (cold storage)
and Alternating Relay
800VA @ 120VAC Ballast
Surface Mount PIR High Bay 1200VA @ 277VAC Ballast
OSFHS-ITW 55ft., 7 ft side @ 30 ft high
Occupancy Sensor 1500VA @ 347VAC Ballast;
Motor: 120V @ 1/4 HP
OSF10-I0W (120-230-277V)
Incandescent: 598W @ 120V.
OSF10-IUW 240VDC
Integral Luminaire Fixture Mount PIR Fluorescent: 800VA @ 120 VAC, 360°, 1:1 spacing to mounting
OSF10-PPW (power pack)
Occupancy Sensor 1000VA @ 230VAC, 1200VA @ height up to 8’
(120-230-277V)
277VAC 50/60Hz.
OSFCA-36W (36” connection cable)
OSFLN-00W (High-Bay Lens)
Lenses for High-Bay Sensors
OSFLN-00B (Low-Bay Lens)
— —
Offset Adaptor Accessory for Fixture- OSFOA-00W
Mount High-Bay Occupancy Sensor OSFLO-00W
— —
Protective Cage for High-Bay Sensors OSFCG-00W — —
Agency Listings & Code Compliance: UL/cUL Listed and CA Title 24 Compliant * Available in White only. Consult with factory for 208, 220, 230 and 240V models.

44
CEILING MOUNT MULTI-TECHNOLOGY OCCUPANCY SENSORS
These advanced motion sensors combine infrared and ultrasonic technology for highly accurate monitoring without false
triggers. All-digital self-adjusting technology provides "install and forget" solution for automatic lighting control. Available in
a variety of coverage patterns to suit many applications. Use with Leviton Power Pack.

SPECIFICATIONS & FEATURES 1.55


(39.4)
Functional
• Ultrasonic sensing for maximum sensitivity combined with passive infrared (PIR)
sensing to prevent false triggers from air conditioning and corridor activity
• Self-adjusting settings continuously analyze and adjust sensitivity, timer operation,
and air current compensation for reliable, long-term performance 4.20
• Isolated relay supports HVAC or other Class 2 low voltage signals (106.7)

• Supports 24VAC/VDC power supplies


• Ambient light override prevents lights from turning on when there is ample natural light
• Manual delayed-off-time settings of 30 seconds to 30 minutes
• Self-adjusting delayed-off-time interval settings for 30 seconds to 30 minutes OSC05-M0W
• Compensates for real-time occupancy patterns—prevents unnecessary on/off switching
• Non-volatile memory preserves all automatic and manual settings during power outages 1.55
(39.4)
Physical

Sensing Control | Low Voltage


• Small, unobtrusive unit blends in with any décor
• Fast, simple installation using 4 color-coded low-voltage wires and a single mounting post
• Compatible with Wiremold® surface raceways for mounting to hard ceilings
4.20
Ideal Uses (106.7)
• Classrooms, office areas with cubicles, cafeterias, and public areas in commercial facilities

TESTING & CODE COMPLIANCE


• CUL/US, FCC and NOM Certified
• CA Title 24 compliant and meets ASHRAE Standard 90.1 2010 requirements
• Backed by a limited five-year warranty OSC20-M0W

COMMERCIAL GRADE OPERATING


DESCRIPTION CAT. NO. FREQUENCY COVERAGE COLOR
Multi-Technology Ceiling Mount Occupancy Sensor OSC05-M0W 180°, 500SF
40kHz
Multi-Technology Ceiling Mount Occupancy Sensor OSC10-M0W 360°,1000SF Off-White
Multi-Technology Ceiling Mount Occupancy Sensor OSC20-M0W 32kHz 360°, 2000SF
Multi-Technology Ceiling Mount Occupancy Sensor with Isolated Relay OSC05-RMW 180°, 500SF
40kHz
Multi-Technology Ceiling Mount Occupancy Sensor with Isolated Relay OSC10-RMW 360°, 1000SF White
Multi-Technology Ceiling Mount Occupancy Sensor with Isolated Relay OSC20-RMW 32kHz 360°, 2000SF
Power Base Adaptor OPB15-0DW - -
Cosmetic Adaptor OPBCA-00W - - Off-White
Protective Cage for Ceiling-Mount Sensors ODCCG-000 - -
NOTE: Use low-voltage wiring to connect sensors to OSPXX Power Pack.

20 TOP VIEW TOP VIEW


20 TOP VIEW
20

16
11.5
11.5
8.5 11.5
8.5

0 0 0

8.5
8.5
11.5 11.5
11.5
16

20
20
20

SIDE VIEW SIDE VIEW SIDE VIEW


8 8
8

0 0 Minor Motion, IR
0 3 5.6 9 11 15 20 20 15 11 9 5.6 3 0 3 5.6 9 11 15 20 20 15 11 9 5.5 3 0 3 5.5 9 11 15 20
17 23 23 17 17 23
Minor Motion, IR Major Motion, IR32 22.5 22.5 32

OSC05-M0W Field of View (in feet) OSC10-M0W Field of View (in feet) OSC20-M0W Field of View (in feet)
Minor Motion, IROSC10-M0W Major Motion, IR Minor Motion, Ultrasonic
OCS05-M0W

Major Motion, IR Minor Motion, Ultrasonic Major Motion, Ultrasonic


OSC20-M0W

Minor Motion, Ultrasonic Major Motion, Ultrasonic

Major Motion, Ultrasonic


www.leviton.com/les 45
ULTRASONIC CEILING-MOUNT OCCUPANCY SENSORS 1.34 (34.0)
Advanced ultrasonic sensing technology for highly accurate monitoring, including small-motion
detection. All-digital self-adjusting technology provides an "install and forget" solution for
automatic lighting control. Use with Leviton Power Pack.

SPECIFICATIONS & FEATURES 4.20


Functional (106.7)

• Ultrasonic sensing for maximum range and sensitivity combined with accurate small-motion
detection
• Self-adjusting settings continuously analyze and adjust sensitivity, timer operation, and air
current compensation for reliable, long-term performance OSC05-U0W
• Ambient light override to prevent lights from turning on when there is ample natural light
• Manual delayed-off-time settings of 30 seconds to 30 minutes
1.34 (34.0)
• Self-adjusting delayed-off time interval settings for 30 seconds to 30 minutes.
Compensates for real-time occupancy patterns—preventing unnecessary ON/OFF switching
• Non-volatile memory preserves all automatic and manual settings during power outages
Physical
• Small, unobtrusive unit blends in with any décor 4.20
(106.7)
• Fast, simple installation using 4 color-coded low-voltage wires and a single mounting post
Sensing Control | Low Voltage

• Compatible with Wiremold® surface raceways for mounting to hard ceilings


Ideal Uses
• Restrooms, office areas with cubicles, warehouse and storage facilities, cafeterias, and public
areas in commercial facilities OSC20-U0W

TESTING & CODE COMPLIANCE


• CUL/US Certified
• Meets ASHRAE Standard 90.1 2010 requirements
• Backed by a limited five-year warranty

COMMERCIAL GRADE OPERATING


DESCRIPTION CAT. NO. FREQUENCY COVERAGE COLOR
U/S Ceiling Mount Occupancy Sensor OSC05-U0W 180°, 500SF
40kHz
U/S Ceiling Mount Occupancy Sensor OSC10-U0W 360º, 1000SF Off-White
U/S Ceiling Mount Occupancy Sensor OSC20-U0W 32kHz 360°, 2000SF
U/S Ceiling Mount Occupancy Sensor with Isolated Relay OSC05-RUW 180º, 500SF
40kHz
U/S Ceiling Mount Occupancy Sensor with Isolated Relay OSC10-RUW 360º, 1000SF White
U/S Ceiling Mount Occupancy Sensor with Isolated Relay OSC20-RUW 32kHz 360º, 2000SF
Cosmetic Adaptor OPBCA-00W - -
Protective Cage for Ceiling-Mount Sensors ODCCG-000 - - Off-White
Power Base Adaptor OPB15-0DW - -
NOTE: Use low-voltage wiring to connect sensors to OSPXX Power Pack.

11.5 16

8.5 11.5
11.5

8.5

0 0
0

11.5
8.5 8.5
16
11.5 11.5

5 0 10 20 0 0
17 23 23 17 17 23 32 22.5 22.5 32
Minor Motion, IR
OSC05-U0W Field of View (in feet) OSC10-U0W
Minor Motion, IR Field of View (in feet)
Major Motion, IR OSC20-U0W Field of View (in feet)
OSC10-U0W
Major Motion, IR Minor Motion, Ultrasonic OSC20-U0W

OSC05-U0W
Minor Motion, Ultrasonic Major Motion, Ultrasonic
Major Motion, Ultrasonic

46
CEILING MOUNT PIR OCCUPANCY SENSORS
1.55
SPECIFICATIONS & FEATURES (39.4)
Functional
• Self-adjusting settings continuously analyze and adjust sensitivity, timer operation, and
long-term performance
• Isolated relay supports HVAC or other Class 2 low voltage signals
• Supports both 24VAC/VDC power supplies 4.20
(106.7)
• Ambient light override prevents lights from turning on when there is ample natural light
• Manual delayed-off-time settings of 30 seconds to 30 minutes
• Self-adjusting delayed-off-time interval settings for of 30 seconds to 30 minutes.
Compensates for real-time occupancy patterns—preventing unnecessary on/off switching
• Non-volatile memory preserves all automatic and manual settings during power outages OSC04-I0W
Physical
• Small, unobtrusive unit blends in with any décor
• Fast, simple installation using 4 color-coded low-voltage wires and a single mounting post
• Compatible with Wiremold® surface raceways for mounting to hard ceilings
Ideal Uses

Sensing Control | Low Voltage


• Small offices, closets, open offices, and other areas in commercial facilities with unobstructed view of the sensor

TESTING & CODE COMPLIANCE


• CUL/US Certified
• Meets ASHRAE Standard 90.1 2010 requirements
• Backed by a limited five-year warranty

COMMERCIAL GRADE
DESCRIPTION CAT. NO. COVERAGE COLOR
PIR Ceiling Mount Occupancy Sensor OSC04-I0W 360°, 450SF
Off-White
PIR Ceiling Mount Occupancy Sensor OSC15-I0W 360°, 1500SF
PIR Ceiling Mount Occupancy Sensor with Isolated Relay OSC04-RIW 360°, 450SF
White
PIR Ceiling Mount Occupancy Sensor with Isolated Relay OSC15-RIW 360°, 1500SF
Power Base Adaptor OPB15-0DW
-
Cosmetic Adaptor OPBCA-00W -
Protective Cage for Ceiling Mount Sensors ODCCG-000 Off-White
NOTE: Use low-voltage wiring to connect sensors to OSPXX Power Pack.

TOP VIEW TOP VIEW


12
20

5 10

0 0 Minor Motion, IR
Major Motion, IR

5 Minor Motion, Ultrasonic


10
Major Motion, Ultrasonic

12
20
SIDE VIEW
8
SIDE VIEW
8

0
9 7 5 3 0 3 9
20 15 11 9 5.6 3 0 3 5.6 9 11 15 20
12 5 7 12
OSC04-I0W Field of View (in feet) OSC15-I0W Field of View (in feet)

OSC04-I0W OSC15-I0W www.leviton.com/les 47


4.12
(104.6)
WALL MOUNT/CEILING MULTI-TECHNOLOGY OCCUPANCY SENSORS
Advanced motion sensors combine infrared and ultrasonic technology for highly accurate
monitoring without false triggering. Advanced Passive Infrared technology for highly 3.67
accurate monitoring in a variety of commercial applications. All-digital self-adjusting (93.2)
technology provides “install and forget” solution for automatic lighting control.
5.50
(139.7)
SPECIFICATIONS & FEATURES
• Ultrasonic sensing for maximum sensitivity combined with passive infrared (PIR) sensing
to prevent false triggers from air conditioning and corridor activity
• Isolated relay supports HVAC and other Class 2 low voltage signals
• Supports both 24VAC and 24VDC power supplies 2.80
(71.1)
• Adjustable swivel neck rotates 80° vertically and 60° horizontally. Can be used for ceiling
or wall mounting OSW12-M0W

• Self-adjusting settings continuously analyze and adjust sensitivity, timer operation, and
4.12
air current compensation for reliable, long-term performance (104.6)
• Ambient light override to prevent lights from turning on when there is ample natural light
• Manual delayed-off-time settings of 30 seconds to 30 minutes 3.67
(93.2)
• Self-adjusting delayed-off-time interval settings of 30 seconds to 30 minutes.
Compensates for real-time occupancy patterns, preventing unnecessary on/off switching
Sensing Control | Low Voltage

• Non-volatile memory preserves all automatic and manual settings during power outages
• Fast, simple installation using 3 color-coded low-voltage wires and a single mounting post 5.50
(139.7)
Ideal Uses
• Conference rooms, stairwells, high-ceiling rooms, open areas, storage rooms, and
classrooms—including corner mounting in a variety of applications

2.80
TESTING & CODE COMPLIANCE (71.1)
• CUL/US Certified
OSW12-RMW
• Meets ASHRAE Standard 90.1 2010 requirements Field of View (in feet)
• Backed by a limited five-year warranty TOP VIEW
58

COMMERCIAL GRADE OPERATING


DESCRIPTION CAT. NO. FREQUENCY COVERAGE COLOR 31

Wall Mount
16
Multi-Technology OSW12-M0W Off-White 11.5

Occupancy Sensor 0

Wall Mount 32kHz 115°, 1200SF


11.5
Multi-Technology 16
OSW12-RMW White
Occupancy Sensor
31
with Isolated Relay
Power Base Adaptor OPB15-0DW
-
Cosmetic Adaptor OPBCA-00W 58
- -
Protective Cage for
OSWCG-P0W Off-White 8 SIDE VIEW
Wall-Mount Sensors
NOTE: Use low-voltage wiring to connect sensors to OPP20 or OSPxx Power Pack or OPB15 Power Base Adapter
0
0 3 8 15 31 68
23 32

OSW12-M0W Field of View (in feet)

OSW12-M0W
Minor Motion, IR
Major Motion, IR

Minor Motion, Ultrasonic


Major Motion, Ultrasonic

48
INFRARED INDOOR WALL MOUNT/CEILING OCCUPANCY SENSORS 4.12
(104.6)
Advanced PIR technology for highly accurate monitoring. All-digital self-adjusting
technology provides an "install and forget" solution for automatic lighting control.
Use with Leviton Power Pack. 3.67
(93.2)
SPECIFICATIONS & FEATURES
• Self-adjusting settings continuously analyze and adjust for optimum performance 5.50
(139.7)
• Isolated relay supports HVAC or other Class 2 low voltage signals OSWxx-RIW
• Supports both 24VAC/VDC power supplies
• Adjustable swivel neck rotates 80° vertically and 60° horizontally. Can be used for ceiling
or wall mounting 2.80
(71.1)
• Ambient light override prevents lights from turning on when there is ample natural light
• Manual delayed-off-time settings of 30 seconds to 30 minutes 4.12
(104.6)
• Self-Adjusting delayed-off-time interval settings for 30 seconds to 30 minutes.
Compensates for real-time occupancy patterns—preventing unnecessary ON/OFF switching
• Non-volatile memory preserves all automatic and manual settings during power outages
• Fast, simple installation using 3 color-coded low-voltage wires and a single mounting post OSWxx-I0W
Ideal Uses 5.50

Sensing Control | Low Voltage


• OSWWV-I: conference rooms, stairwells, high-ceiling rooms, large open areas, parking (139.7)

garages, storage rooms, and rooms with pendant fixtures. Also ideal for corner mounting
• OSWHB-I & OSWLR-I: monitoring long, narrow spaces such as warehouse aisles,
hallways, closets, and storage areas. Also ideal for corner mounting
2.80
TESTING & CODE COMPLIANCE (71.1)

• CUL/US Certified • Meets ASHRAE Standard 90.1 2010 requirements • Backed by a limited five-year warranty
Field of View (in feet)
COMMERCIAL GRADE
TOP VIEW
DESCRIPTION CAT. NO. COVERAGE COLOR 58
Wall Mount PIR Wide-View
OSWWV-I0W 115°, 2500SF
Occupancy Sensor
Wall Mount PIR High-Bay 55 ft., 7 ft. wide
OSWHB-I0W Off-White 29
Occupancy Sensor @ 30 ft. high
Wall Mount PIR Long-Range 100ft., 110º
OSWLR-I0W
Occupancy Sensor @ 10ft. high 0
Wall Mount PIR Wide-View
OSWWV-RIW 115°, 2500SF
Occupancy Sensor with Isolated Relay
Wall Mount PIR High-Bay 55ft., 7ft wide
OSWHB-RIW White 29
Occupancy Sensor with Isolated Relay @ 30ft. high
Wall Mount PIR Long-Range 100ft., 110°
OSWLR-RIW
Occupancy Sensor with Isolated Relay @ 10ft. high 58

Power Base Adaptor OPB15-0DW


Cosmetic Adaptor OPBCA-00W - Off-White 8
SIDE VIEW

Protective Cage for Wall-Mount Sensors OSWCG-P0W


Field of View (in feet)
NOTE: Use low-voltage wiring to connect sensors to OPP20 or OSPxx Power Pack or OPB15 Power Base Adapter
0
TOP VIEW 0 3 8 15 31 68
Field of View (in feet)
16.6 OSWWV Field of View (in feet)
TOP VIEW

3.5
0 0
3.5
OSWWV-I0W

16.6 30 SIDE VIEW


Minor Motion, IR

10 SIDE VIEW Major Motion, IR

Minor Motion, Ultrasonic


Major Motion, Ultrasonic

0
0 3 13 25 52
0 14 42 71 100

OSWLR Field of View (in feet) OSWHB Field of View (in feet)
OSWHB-I0W

OSWLR-I0W www.leviton.com/les 49
OCCUPANCY SENSOR POWER PACKS 3.66
Power packs provide power for occupancy sensors as well as load (93.0)
switching circuitry. A Leviton Power Pack is required with any low
voltage occupancy sensor. Add-A-Relay units can be used to ex-
pand control capability.

SPECIFICATIONS & FEATURES 2.35


OPP20 Super Duty Power Pack (59.7)
• Robust and reliable mechanically held 20A latching relay provides
dependability and robust performance for all load types and pro-
vides power savings over electrically held relay power packs
• Industry exclusive fail-safe circuitry - in the event of product
failure, Return-to-Closed capability causes relay to default to OSP20-RDH
a closed position (ON) for safe operation and alleviates safety
concerns
• Industry exclusive H.I.S. (High Inrush Stability) circuit designed to
3.81
handle high inrush LED and electronic ballast loads
(96.8)
• Switching control of LED drivers
• Submitted and passed for stringent testing
- Tested over 1,500,000 loaded cycles
Sensing Control | Power Packs

- Passed NEMA 410 testing for electronic ballast current 2.40


overload at 16A (60.9)
- CA Title 24 Compliant
- Meets ASHRAE Standard 90.1 2010 requirements
- UL/cUL 916 Listed for Energy Management Equipment
• Multiple compliance and regulatory UL and CSA testing - consult OPP20-RD4
factory for details
• Output short circuit protection
• Optimal installation flexibility
- Class 2 wires are Teflon coated for UL2043 Plenum Rated
applications
- Mounts inside or outside fluorescent ballast cavity
- Mounts inside or outside junction box
OPP20-0D2
• Exclusive self-detect configurable local manual control with standard momentary or maintained wall switch
• Configurable for Auto-ON and Manual-ON occupancy sensor inputs
• Complies with CA Title 24
OPP20-RD3
• Auto-ON occupancy sensor input
• Photocell (switching only) ready
OPP20-RD4
• Exclusive self-detect configurable local switch input - momentary or maintained
• Configurable for Auto-ON and Manual-ON occupancy sensor inputs
• Photocell (switching only) ready
• CA Title 24 Compliant
OSP20-RDH Power Pack
• Auto-ON and manual-ON inputs for occupancy sensors
• Hold-ON and Hold-OFF capabilities
• Switches incandescent, magnetic and electronic fluorescent, magnetic and electronic low voltage, and motor loads
• Compact size and light weight allows easy mounting through knockout in junction box (from either inside or outside
the box) with a simple twist-on nut

50
Add-A-Relay
• Expands power pack load capacity by functioning as a supplementary relay
• Provides ability to switch loads in different voltage systems
• Compatible with electronic ballasts
• Same compact size and mounting features as Power Pack
• Zero-crossing switching circuitry for outstanding durability
Nipple Adaptor
• Simplifies the connection of an occupancy sensor to the low-voltage side of a power pack mounted inside a fluorescent
ballast cavity
• 1/2" conduit lock nut included with all power packs

TESTING & CODE COMPLIANCE


• CUL/US, FCC and NOM Certified
• Meets ASHRAE Standard 90.1 2010 requirements
• Backed by a limited five-year warranty

POWER PACKS
COMMERCIAL GRADE POWER
POWER CONTROL SUPPLY

Sensing Control | Power Packs


DESCRIPTION CAT. NO. INPUT* RELAY RATING INPUT OUTPUT
Super Duty Power Pack with 20A, 2400W @ 120V — Resistive
Auto-ON, Manual-ON, and 20A, 2400W @ 120V — General Purpose
OPP20-0D2 20A, 2400W @ 120V — Incandescent
Local Switch Inputs, CA Title
24 Compliant 20A, 2400W @ 120V — LED Fluorescent
20A, 5540W @ 277V — Resistive
20A, 5540W @ 277V — General Purpose
Super Duty Power Pack 225mA,
20A, 5540VA @ 277V — LED Fluorescent
with Auto-ON and Photocell OPP20-RD3 24VDC,
16A, 4430VA @ 277V — Electronic Ballasts
Input 120-230- 5.4W
1/2 HP @ 120V — Motor Load
277VAC, 2 HP @ 240/277V — Motor Load
Super Duty Power Pack with 50/60 Hz OPP20-RD4 is for general purpose plug load
Auto-ON, Manual-ON, Local control - 20A, 2400W @ 120V - complies
OPP20-RD4 2mA,
Switch, and Photocell Input, with ASHRAE 90.1 and CA Title 24 Plug Load 24VDC
CA Title 24 Compliant Control Requirements
Power Pack with HVAC Relay 20A Incandescent @ 120V, 20A
with Auto-ON and Manual- LED Fluorescent @ 120-230-277/347VAC; 225mA,
OSP20-RDH
ON Inputs for 1/2HP @ 120V, 2HP @ 240-277V; 24VDC
Occupancy Sensors HVAC: 0.5A @ 120VAC, 1A @ 30VDC
15A fluorescent @ 347V; 1HP @ 120V,
347VAC, 120mA,
Power Pack with HVAC relay OSP15-R30 2HP @ 240V;
60 Hz 24VDC
HVAC: 0.5A @ 120VAC, 1A @ 30VDC
Add-A-Relay Unit with 15A incandescent @ 120V,
OSA20-R00 — —
HVAC relay HVAC: 0.5A @ 125VAC, 1A @ 30VDC
* Consult with factory for 208, 220, and 240V models.
NOTE: For use with the following Low Voltage Switches:
- 56081-02I/W Low Voltage Momentary Contact Decora Rocker Switch
- 12021-02I /W Low Voltage Standard Toggle Switch
- 56021-02I /W Low Voltage Decora Rocker Switch

POWER PACK CAPACITY FORMULA


Leviton power packs can be used to provide power to one or more occupancy sensors. Since current consumptions of
occupancy sensors may vary, the best way to ensure you order the correct number of power packs and add-a-relays is by
using this formula: # of sensor Model As # of sensor Model Bs
# of Add a Relays
X X
+
Sensor A current Sensor B current
+ X <
- 225mA
50mA
consumption rating consumption rating

SENSOR CURRENT CONSUMPTION


OSC04-RI, OSC15-RI, OSWHB-RI, OSWLR-RI, OSWWV-RI 10-15mA
OSC05-RU, OSC05-RU, OSW12-RU 25mA
OSC10-RU, OSC10-RU 30mA
OSC20-RU, OSC20-RU 40mA
OSA20-R00 Add a Relay 50mA

www.leviton.com/les 51
SELF-CONTAINED POWER BASE ADAPTOR
• Patented design converts Leviton low voltage ceiling sensors to line voltage
• Ideal for both existing buildings with limited access to low-voltage wiring and
new constructions with line-voltage circuiting only.
• Mounts easily in standard 2.125" deep x 4" octagon or 2.125" deep x 4" square 4.50
electrical box with a 2-gang mud ring; flying leads provide fast line voltage (114.3)
connections
• Two-piece terminal block provides fast, easy low-voltage connections to the sensor
• Relay uses zero-crossing circuitry for enhanced reliability and long-life operation

Ideal Uses 1.75


(44.5)
• Lavatories, remodels in hard ceiling spaces, energy conservation retrofits and any
installation with limited access for low-voltage wiring.
OPB15-0DW

TESTING & CODE COMPLIANCE


• NOM Certified
Sensing Control | Power Base Adaptor

POWER BASE ADAPTOR*


DESCRIPTION CAT. NO. POWER INPUT/OUTPUT RATING COLOR
Power Input: 120-230-277VAC, 50/60Hz
Converts select Leviton low-voltage
Control Input: 24VDC, 5mA Power Output:
ceiling or wall mount occupancy
OPB15-0DW 120VAC @ 15A incandescent; 277VAC @ 15A
sensor models to a self-contained Off-White
15A fluorescent; Motor: 120VAC 3/4HP,
line voltage unit
277VAC 2HP Control Output: 24VDC, 40mA
Cosmetic Adaptor OPBCA-00W — —
Agency Listings & Code Compliance: NOM Certified.
* Available in Off-White only. Consult with factory for 208, 220, 230 and 240V models.
NOTE: Coverts OSCxx-I, OSCxx-M and OSCxx-U. Does not convert OSCxx-R.

OPB15-0DW (Occupancy sensor not included)

NEUTRAL (WHITE)

LOAD
HOT (BLACK)
120-277V LOAD (BLUE)

OPB15 Power Base


Any Leviton Low-Voltage
Ceiling or Wall Mount Sensor

OPB15-0DW Wiring Diagram

52
www.leviton.com/les 53
OUTDOOR MOTION SENSORS 9.16
Passive Infrared (PIR) outdoor motion sensors provide outstanding value in (232.7)
security lighting, as well as convenience, safety and energy savings for a wide
range of commercial and residential applications.
5.36
SPECIFICATIONS & FEATURES (136.1)

Professional Series 4.50


(114.3)
• Adjustable sensitivity and immunity to RFI signals reduces false triggers
• Ambient light override prevents lights from turning on when there is ample 2.43
(63.0)
natural light
• Surge suppression minimizes likelihood of damage due to electrical surges
• Temperature compensation feature ensures uniform performance in extreme
hot or cold weather and during temperature fluctuations
PS200
Residential Series
• Ideal for a wide range of residential settings including backyards, garages, Field of View (in feet) Field of View (in feet)
entranceways, porches, swimming pool areas, doorways, and private docks
TOP VIEW TOP VIEW
• Adjustable sensitivity reduces false triggers 50 50

Both Series 1.838


(00.0)
• Sensor neck adjustment allows accurate monitoring: 110° vertical, 180°
horizontal, 110° rotational
Sensing Control | Outdoor

• With or without a dual floodlight lampholder


0
• Adjustable delayed-off-time settings from 20 seconds (for test mode) to
0

15 minutes
• Provides automatic, test and continuous modes. Test mode simulates
automatic operation with short delayed-OFF-time for easy adjustments.
Continuous mode enables manual override for constant
­­ "lights ON" operation
(when used with standard ON/OFF switch) 50 50

Ideal Uses SIDE VIEW SIDE VIEW


10 10
• A wide range of commercial/industrial settings including parking areas,
storage facilities, warehouses, loading docks, marina, garages, walkways,
0 0
0 50 0 50

campus grounds, and outbuildings PS110/RS110 PS200


PS110 Field of View PS200 Field of View
TESTING & CODE COMPLIANCE (in feet) (in feet)
• UL and cUL Listed
• Meets ASHRAE Standard 90.1 2010 requirements
• Backed by a limited five-year warranty

COMMERCIAL GRADE
DESCRIPTION CAT. NO. RATING COVERAGE COLOR
Outdoor PIR Motion Sensor PS200-10
200°
Outdoor PIR Motion Sensor with Dual Floodlight Lampholder PS200-1F
Incandescent: 1000W @ 120V. For 60Hz AC only
Outdoor PIR Motion Sensor PS110-10
110°
Outdoor PIR Motion Sensor with Dual Floodlight Lampholder PS110-1F
Outdoor PIR Motion Sensor PS200-70W
277VAC, 60Hz. 7.22 incandescent, 5A ballasts. White
Outdoor PIR Motion Sensor with Dual Floodlight Lampholder PS200-7FW
200°
Outdoor PIR Motion Sensor PS200-40W
220-240VAC, 50/60Hz. 10A incandescent, 5A ballasts.
Outdoor PIR Motion Sensor withDual Floodlight Lampholder PS200-4FW
Outdoor PIR Motion Sensor PS110-70W
277VAC, 60Hz. 7.22 incandescent, 5A ballasts. 110°
Outdoor PIR Motion Sensor with Dual Floodlight Lampholder PS110-7FW

RESIDENTIAL GRADE
DESCRIPTION CAT. NO. RATING COVERAGE COLOR
Outdoor PIR Motion Sensor RS110-10W
Incandescent: 500W @ 120V. For 60Hz AC only 110° White
Outdoor PIR Motion Sensor with Dual Floodlight Lampholder RS110-1FW

54
PHOTOCELLS
Leviton’s Photocell sensors precisely monitor either
task or ambient light levels. As part of a Leviton energy
management system, photocells work with other
components in the system to automatically adjust light
levels to a user-defined level. Photocells are most
suitable for installation in rooms with windows and open
spaces receiving substantial ambient light.

Photocells must be hardwired to a compatible Leviton


lighting control system. The photocell measures ambient
light in a specific area and sends this data to a dimmer
or relay that, in turn, adjusts fixtures to a constant
lighting level as measured in that specific area. Daylight
harvesting is achieved as lights in a room (with windows
or significant, artificial ambient light) automatically
brighten or dim depending on how much light the
photocell detects.

Daylight Harvesting

Sensing Control | Photocells


With daylight harvesting, ambient (often natural) light
supplements in-room, artificial light in order to keep a
constant lighting level while saving energy. This constant
level is programmed into a compatible control device.
Once hardwired to the photocell, the dimmer or relay
will receive the photocell’s real-time light measurement
and maintain a steady level within the photocell’s area of
detection.

Rules of Operation
Measured light level = Light Maintain Level Action: Output to lights remains constant
Measured light level < Light Maintain Level Action: Lights are brightened
Measured light level > Light Maintain Level Action: Lights are dimmed

Energy
Savings
Footcandles Begin

Light
Maintain Perceived
Level Light
Level

Min.
Light
Level
6AM 8AM 10AM NOON 2PM 4PM 6PM

Light generated from Ambient light


fixture attached to Leviton
Lighting Control System

www.leviton.com/les 55
SPECIFICATIONS & FEATURES
• Indoor photocells are designed with a flat Fresnel lens • PCIND indoor photocell with 60° clear Fresnel lens is
that looks downward in a 60° cone of reference to default setting = 75-800FC sensing range; can be field
measure actual light on the work surface, and reducing adjusted to 800FC max sensing range; PCIND should be
the influence of stray light striking the photocell from mounted to the ceiling, facing down
nearby windows or incidental side lighting • PCIND-0SV side view photocell for applications where
• Outdoor photocells are IP54 rated to guarantee ultimate ceiling mounting is required yet the view should be of
protection from dirt, dust, oil and other non-corrosive the lighting entering the space through a window; or,
material for installation to the wall of skylights where the view
• Measures light from any source in the visible spectrum should be up into the skylight; default setting = 0-3FC
within a 60º cone or 180º angle of response depending sensing range; can be field configured with a jumper for
on the model a 3FC, 30FC, 300FC, or 600FC max sensing range
• Constant lighting at the optimal level for greater visual • PCOUT outdoor photocell is enclosed in a weatherproof
comfort and acuity, which contributes to improved housing with a visor for shading and lens protection;
productivity default setting = 50-750FC sensing range
• Provides convenient, automatic hands-free daylight • PCOUT-0SV side view photocell for applications where
harvesting when integrated with Leviton lighting control wall mounting is required yet the view should be of the
products lighting entering the space through a top/side and/or
• Lowers electric bills by reducing usage of lighting where face of the photocell; reference placement diagrams;
ambient natural light is also present default setting = 0-3FC sensing range; can be field
configured with a jumper for a 3FC, 30FC, 300FC, or
Sensing Control | Photocells

• Lumen maintenance opportunity compatible 600FC max sensing range


• ODC0P-00W photocell with 60° clear lens operates • PCATR atrium photocell with opaque dome lens filters
between 1-1600FC; ODC0P-00W should be surface 33% of light level in upper atrium; default setting =
mounted or direct to ceiling box 215-2690FC sensing range; can be field adjusted to
• ODC0P-S0W switching photocell with 60° clear lens 2690 FC max sensing range
operates between 1-1600FC; ODC0P-S0W should be • PCSKY skylight photocell with dark dome lens filters
surface mounted or direct to ceiling box 90% of light level in skylight; default setting = 1076-
• ODC0P-D0W dimming photocell with 60° clear lens 8072FC sensing range; can be field adjusted to 8072FC
operates between 1-1600FC. ODC0P-D0W should be max sensing range
surface mounted or direct to ceiling box
• PCCxD-00W, PCCxS-00W, PCCSD-00W line voltage
photocells with 60° clear lens for applications where
zone control switching, dimming, and demand response
are required. Operates between 1-1600FC. PCC-XXX
photocells should be mounted to the ceiling in standard
4”x4” square or octagon electrical boxes

PHOTOCELLS
ORDERING INFORMATION
CAT. NO. DESCRIPTION LENS SENSING RANGE
ODC0P-00W Photocell
ODC0P-S0W Switching Photocell
Clear 1-1600FC
ODCOP-D0W Dimming Photocell
PCCxx-00W Line Voltage Photocell
PCIND-000 Indoor Photocell Fresnel 75-800FC
PCIDN-0SV Indoor Side View Photocell 3, 30, 300 or 600FC
Clear Hood
PCOUT-000 Outdoor Photocell 50-750FC
PCOUT-0SV Outdoor Side View Photocell Diffuse 0-300FC
PCATR-000 Atrium Photocell 215-2690FC
Dome/Frost
PCSKY-000 Skylight Photocell 1,076-8,072FC

56
www.leviton.com/les 57
LevNet RF™ is Leviton’s family of self-powered radio frequency wireless products.
Self-powered technology allows LevNet RF Transmitters (i.e., occupancy sensors and switches) to operate without external
power or batteries. Self-powered Transmitters receive power from the motion of a switch actuation, light on a solar cell or
temperature differentials in the environment for a true zero-maintenance self-powered device. Operating in the 902 MHz
band provides minimal competing traffic and greater transmission range than other technologies.

PRODUCT OVERVIEW
There are two main types of LevNet RF Products: Transmitters and Receivers.

Transmitter, such as a switch, generates a wireless RF control signal (e.g., “ACTUATE RELAY”). All transmitters are self-
powered products which can be located anywhere and send transmission signals. Transmitters are available in Occupancy
Sensor, Control Extender, Decora Rocker Self-Powered Switch and Handheld Remote varieties.

Receiver receives a control signal from a Transmitter and performs the appropriate action (e.g., activate or deactivate the
relay). All Receivers are connected to a power source and a load which the Receiver then operates when the RF signal is
received. Receivers are available in Decora Rocker Wall Switch, Relay Power Pack, Receptacles and Area and Fixture Controller
styles.

FEATURES AND BENEFITS


• Easy to install for new construction and retrofitting applications, requiring minimal labor or disruption to operations
Room Control | LevNet RF™

• Requires no new wiring and installs in ¼ the time of hardwired sensors, translating into faster turnaround and reduced costs
• With no batteries to replace and no maintenance to perform, plus annual energy savings and rebates that can total up to
80% in reduced costs, LevNet RF revolutionizes efficiency and savings
• Lowest power consumption of any RF device with less than one Watt per device used annually, saving approximately 70%
over other RF devices
• California Title 24 2013 and ASHRAE Standard 90.1 2010 compliant
• LevNet RF is the only energy harvesting wireless solution that fulfills LEED requirements to earn LEED points for both wireless
control and no battery.

WIRED VS. WIRELESS COSTS

* Installation time per device: 45-50 minutes for hardwire vs. 10-15 minutes for wireless devices

58
HOW TO PUT IT ALL TOGETHER
TIP: A good way to visualize your wireless system is to imagine that the “wires” connecting each device are invisible wires or “unique addresses.”
LEVNET RF LEVNET RF
LOADS RECEIVERS TRANSMITTERS

Switching

Commercial Self-Powered
Lights Occupancy Sensor
Wall Switch
Reciver
Control
Signal
Up To
Dimming 150 ft.

Commercial 1-10 V
Lights Area Controller,
20A

Switching

Power Pack, Self-Powered


Heating & Cooling 20A Wall Switches

Control
Signal
Up To

Room Control | LevNet RF™


150 ft.

Switching

Task Lighting, Self-Powered


Computer Monitor, 4-Button
Cell Phone Charger RF Receptacle
Handheld Remote

Switching

RF Receptacle
Television Continuously ON

STEP Determine what LOADS you want to control — lighting, HVAC, lamp, TV, etc.
1

STEP Pick the appropriate RF RECEIVER


2
LevNet RF Energy Harvesting Wired-In Receivers

Receives One Way Communication

STEP Pick the appropriate Energy Harvesting RF TRANSMITTER (sensor or switch)


3
LevNet RF Energy Harvesting Transmitters

One Way Communication

www.leviton.com/les 59
LevNet RF Wireless Self-Powered Solutions
Frequency 902 MHz
Range 50-150 feet (Design to 75 feet)
Listings FCC Certified for Wireless Communication (U.S.), I.C. Certified (Canada)*
Warranty Limited 5-year

RECEIVERS AND TRANSCEIVERS


WALL SWITCH RECEIVERS
ADVANCED WALL SWITCH RECEIVERS
with Color Change Kit
WSS20-N9N | WSS20-G9N
Use for larger rooms with multiple loads.
Pairing for rocker, momentary and toggle.
Input Voltage 120-230-277VAC
Power Consumption 120V < 1/2 Watt; 277V < 2/3 Watt
Memory Stores up to 20 Transmitter IDs
Button Pairing Modes Rocker, Momentary and Toggle
Vacancy Confirmation 30 seconds
Room Control | LevNet RF™

Mode Presentation
Time Delay 2 min (test); 10, 20, 30 min
General Duty: 10A
LED: 400W @ 120V
Incandescent: 800W @ 120V
Load Rating
Fluorescent Ballasts: 1200VA @ 120V, 2700VA @ 277V
Motor: 1/4 HP Load @ 120V
For non-neutral models: 25W minimum load required (reduce range by 15’)
Additional Listings ETL/cETL: UL508, CA Title 24 Compliant, CAN/CSA C22.2 #14
All WSS20 models ship with a Color Change Kit which includes a White, Ivory and Light Almond faceplate.

POWER PACK

LINE VOLTAGE RELAY RECEIVER


WSP20

Memory Stores up to 20 transmitter IDs

Power Supply Input 100-277 VAC, 50/60 Hz


General Duty: 20A
Tungsten (Incandescent): 20A
Max Loads/Contact
Fluorescent Ballast: 20A
Rating
Motor Load: 1HP
Power up state: Selectable N.O. or N.C.
Output Channels 1 Form A Latching Relay, N.O. or N.C.
Time Delay 15 min
ETL (U.S.): UL 60730,
UL 2043 Plenum rating
Additional Listings
ETL (Canada): CSAc22.2#1405
CE (International): IEC 60730

60
CONTROL EXTENDER

CONTROL EXTENDER
WSTLT-9D0
Communicates with receivers that control virtually any ON/OFF device

Power Supply Input 100-277VAC, 50/60 Hz


Addressing Factory set unique ID (1 of 4 billion)
UL 60730 (Safety), UL 2043 (Plenum), CSA C22.2#14-05 (Safety), CE-IEC 60730,
Additional Listings
CA Title 24 Compliant

1-10V DIMMING CONTROLLERS

5A FIXTURE CONTROLLER 20A AREA CONTROLLER


WSD05 WSD20

Memory Stores up to 20 Transmitter IDs


Power Supply Input 100-277VAC, 50/60 Hz
Output Rating - 10mA source

Room Control | LevNet RF™


1 - 1-10V input signal
Input Channels -
1 mA source
1 - latching FORM A relay,selectable N.O. or N.C. power up state
Output Channels
1 - 1-10V output signal (sink 100mA, source 1mA)
Load Rating 5A 20A
UL 60730 and UL 2043, C-ETL: CSAc22.2#14-05,
Additional Listings
C-ETL: CSAc22.2#14-05, CA Title 24 Compliant

RF RECEPTACLE

SPLIT DUPLEX RECEIVER DUPLEX RECEIVER


WSG15-S9W WSG15-D9W

Power Supply 125V AC, 60 Hz, 15A


Power Consumption 120V AC @10mA AC (320mW typical)
General Use/Resistive: 15A
Switched Side:
Incandescent: 1800W
Max Loads/
Inductive: 1800VA
Contact Ratings
1/2HP, 120V AC
Listings A Title 24 Compliant, ASHRAE Standard 90.1 2010 Compliant, TR Receptacle
Controlled Single (Top) Dual
Comes packaged with five color faceplates: White and Ivory, Light Almond, Gray and Black.

www.leviton.com/les 61
TRANSMITTERS
Sensors

CEILING MOUNT OCCUPANCY SENSOR WALL MOUNT OCCUPANCY SENSOR


WSC12-M9N WSWDR-H9W

Coverage 1200SF 1600/2200 SF


Power Consumption (Self-Powered)
30 minutes @ 0.5FC (5 LUX);
Transmission 60 seconds (+/- 10 sec) 15 minutes @ 1.0FC (10 LUX);
30 seconds @ 20FC (200 LUX)
Minimum Light Required 5FC (50 LUX) For auto-OFF Only 1.5FC (15 LUX)
Minimum Charge Time 1 minute @ 1.5FC (15 LUX);
1 minute @ 20FC (200 LUX)
to Begin Operation 5 seconds @ 20FC (200 LUX)
Maintain Charge Time 3 hours per 24 hours @ 20FC (200 LUX)
Operating Life at Full Charge 80 hours 48 hours
Additional Listings CA Title 24 Compliant, FCC Certified for Wireless Communication (U.S.), I.C. Certified (Canada)

REMOTE WALL STATIONS Controls virtually any on/off device


Room Control | LevNet RF™

HANDHELD
SINGLE ROCKER DUAL ROCKER
4-BUTTON
DECORA™ WALL STATION* DECORA™ WALL STATION*
REMOTE
WSS0S-S9x WSS0S-D9x
WSS0S-R9W

Buttons 2 Buttons (1 Rocker) 4 Buttons (2 Rockers) 4 Buttons (2 Rockers)


Output Channels Only limited by number of Receivers in range
Addressing Factory set unique ID (1 of 4 billion)
* Available in White (-W), Ivory (-I), Light Almond (-T), Gray (-G) and Ebony (-E).
Note: Wall Stations are both switches and dimmers depending on the receiver they are paired to - see the Wall Station data sheet for details.

62
LEVNET RF WIRELESS SELF-POWERED SOLUTIONS
WIRELESS SELF-POWERED SENSORS
DESCRIPTION CAT. NO.* COVERAGE COLOR
LevNet RF 902 MHz Self-Powered Wireless Low
WSC12-M9N 360°, 1200SF
Profile PIR Ceiling Mount Occupancy Sensor
W
LevNet RF 902 MHz Self-Powered Wireless PIR Wall
WSWDR-H9W 1600/2200 SF
Mount Occupancy Sensor

WALL SWITCH RECEIVERS


DESCRIPTION CAT. NO.* RATING COLOR
Incandescent: 800 @ 120V, 2000W @ 277V
LevNet RF 902 MHz Decora Rocker Wall Switch Fluorescent Ballasts: 1200VA @ 120V, 2700VA @ 277V.
WSS20-G9N
Receiver, Non-Neutral LED: 400W @ 120V
Motor: 1/4 HP Load @ 120V
Incandescent: 800 @ 120V, 2000W @ 277V W, I, T
Fluorescent Ballasts: 1200VA @ 120V, 2700VA @ 277V.
LevNet RF 902 MHz Decora Rocker Wall Switch LED: 400W @ 120V
WSS20-N9N
Receiver, With Neutral Motor: 1/4 HP Load @ 120V
Non-Neutral: 25W minimum load required
(reduce range by 15’)
Note: All WSS20 models ship with a Color Change Kit which includes a White, Ivory and Light Almond wall plate.

WALL STATIONS

Room Control | LevNet RF™


DESCRIPTION CAT. NO. * COLOR
LevNet RF 902 MHz Single Rocker Decora Wall Station WSS0S-S9X
W, I, T, G, E
LevNet RF 902 MHz Dual Rocker Decora Wall Station WSS0S-D9X
LevNet RF 902 MHz Handheld 4-Button Remote WSS0S-R9W W
* Colors available as listed, add suffix to catalog number as follows: Ivory (-I), White (-W), Light Almond (-T), Gray (-G), Ebony (-E).

CONTROL EXTENDER
DESCRIPTION CAT. NO. COLOR
LevNet RF 902 MHz Control Extender, 100-277 VAC WSTLT-9D0 W

LINE VOLTAGE POWER PACK


DESCRIPTION CAT. NO. COLOR
Line Voltage Relay Receiver, 100-277V, 50/60 Hz WSP20-9D0 W

1-10V DIMMING CONTROLLERS


DESCRIPTION CAT. NO. COLOR
LevNet RF 902 MHz Wireless 5A Relay 1-10V Dimming Fixture Controller, 100-277V WSD05-9D0
W
LevNet RF 902 MHz Wireless 20A Relay 1-10V Dimming Area Controller, 100-277V WSD20-9D0

RF RECEPTACLE
DESCRIPTION CAT. NO. COLOR
LevNet RF 902 MHz Split Duplex TR Receptacle Receiver, top controlled WSG15-S9W
W, I, T
LevNet RF 902 MHz Duplex Receptacle Receiver, dual controlled WSG15-D9W

www.leviton.com/les 63
LUMINA™ RF
Lumina™ RF offers a low-cost wireless energy management solution for fast and simple installation at a fraction of the price
of traditional wireless interfaces. Business owners with multiple locations such as franchises and chains benefit from free
multi-location control with no access or control fees. The Lumina Gateway is a self-contained wireless automation controller
with remote capabilities that combines traditionally separated components into a single, ready-to-go boxed solution.

LUMINA GATEWAY HUB


• Functions as an energy management coordinator allowing for
automated control of loads and remote control from a tablet or
smartphone using the Lumina Mobile app
• Wireless energy management for small commercial, retail or
restaurant environments
- Sensors
- Lighting control
- High wattage load control
- Temperature/humidity

LUMINA RF WIRELESS SENSORS


• Window/Door Sensor
Room Control | Lumina™ RF

- Reports open/closed status of windows and doors


- Compact size
-Three color LED event indication/confirmation
• Motion Detector
- Reports occupancy/vacancy within its viewing range
-Three color LED event indication/confirmation
- Coverage area: approximately 16 feet

LUMINA RF PIR OCCUPANCY SENSOR


• Overcomes placement and coverage challenges of traditional
sensors
• Establishes twice as many zones of detection as traditional
sensors with a 4-element PIR located behind a multi-zone
optical lens
• Compatible with other 2.4 GHz Lumina RF products

LUMINA RF RECEIVER SWITCH


• Designed to replace existing switches for load control
• Top ON/bottom OFF
• Top mounted finder LED

LUMINA RF PLUG-IN APPLIANCE MODULE


• Designed for loads up to 15A
• Simple installation
• Current reporting

64
LUMINA RF WIRELESS LOAD CONTROL -
5A AND 30A MODULES
• Used for high current applications like water heaters, pool pumps
and fountains
• Self-contained enclosure
• No local control without a magnet

TEMPERATURE AND HUMIDITY CONTROL


• Omnistat2 Wireless Single-Stage Conventional & Heat Pump
- Gas, oil, steam, hydronic, forced air, radiant and electric
- Air-to-air heat pump and dual fuel
- Proximity sensing
• Lumina RF Universal Thermostat
- Multi-stage universal thermostat
- Two stages of cooling and three stages of heating
- Geothermal heat pump
• Omnistat2 Wireless Multi-Stage & Heat Pump
- Multi-stage thermostat with humidity sensing
- Supports humidification and dehumidification

Room Control | Lumina™ RF


OMNITOUCH 7 TOUCHSCREEN
• Designed to be utilized either as an interface for the Omni
Systems or Lumina RF Gateway
• Access all thermostats including humidity settings
• View crisp IP surveillance video footage without additional
hardware
• Free multi-location access and control for business owners
with multiple locations.

INDOOR/OUTDOOR MINI DOME IP CAMERA


• Capable of 30 frames per second communication
• Supports MJPEG and H.264 formats
• Black and white switching for low light applications

www.leviton.com/les 65
ORDERING INFORMATION
DESCRIPTION CAT. NO. COLOR
Lumina Gateway Hub and setup software 74A00-1 Black
Lumina RF Wall Mount Motion Sensor LURMD-00W
Lumina RF Wall Mount Window/Door Sensor LURDW-00W
White
Lumina RF Ceiling Mount Self-Powered PIR Occupancy Sensor, 450 SF ZSC04-IXW*
Lumina RF Ceiling Mount Self-Powered PIR Occupancy Sensor, 1550 SF ZSC15-IXW*
White, Ivory,
Lumina RF Decora Wall Switch, 2.4GHZ wire-in receiver, 120-277VAC, 50/60 Hz ZSS10-NXZ*
Light Almond
15 Amp Plug-In Load Control Module 89A00-1ZB White
5A Wireless Load Control Module 73A00-3ZB
-
30A Wireless Load Control Module 73A00-4ZB
Omnistat2 Wireless Single-Stage Conventional & Heat Pump RC-1000BLZB Black
Omnistat2 Wireless Single-Stage Conventional & Heat Pump RC-1000SLZB Silver
RC-1000WHZB
Lumina RF Universal Thermostat RC-2000WHZB White
RC-1500WHZB
Room Control | Lumina™ RF

Omnistat2 Wireless Multi-Stage & Heat Pump w/humidity control RC-2000BLZB Black
Omnistat2 Wireless Multi-Stage & Heat Pump w/humidity control RC-2000WHZB White
Omnistat2 Wireless Multi-Stage & Heat Pump w/humidity control RC-2000SLZB Silver
OmniTouch 7 Touchscreen 99A00-001 White
OmniTouch 7 Touchscreen 99A00-002 Black
Indoor/Outdoor Mini Dome IP Camera 68A11-001 White
Lumina Mobile App for iOS and Android - free in iTunes and Android stores - -
*x = Contact factory for a (A) ARRA compliant product. NAFTA compliant and Made in USA models available.

66
www.leviton.com/les 67
INTEGRATED ROOM CONTROL (IRC)
Featuring 1-10V Dimming, Daylight Harvesting and Demand Response Capabilities
Designed to deliver an easy code compliant solution for ASHRAE 90.1 2010 and California Title 24 2013, the Leviton
Integrated Room Control (IRC) combines single room occupancy sensing, daylighting, 1-10V dimming, Partial ON, Partial
OFF and demand response capabilities into a single, easily installed package. IRC features several methods of Ladderless
Commissioning™ for install-and-forget convenience. The performance, features and capabilities of the IRC product provide a
simple and cost-effective stand-alone energy management solution to maximize energy efficiency and meet energy code
mandates for virtually any commercial room control application.

FEATURES
• Stand-alone simplified daylight harvesting with full range
dimming
• Demand response capabilities
• 2 or 3 zone control for LED lighting
• Kitted with factory configured sensor, photocell and 4-button
switch
• 4-button switch available with ON, Bright, Dim and ON/OFF
buttons with optional engraving
• 2 entry stations for individual manual zone control included
with 2 zone, 2 relay kit (RCD20-102)
• CA Title 24 2013 Stairwell Application Control
Room Control | IRC

• Provides plug load control when paired with OPP20 Super Duty
Power Pack
• Cost-effective energy code compliance
• Ladderless Commissioning provides install-and-forget IRC Integrated Room
convenience Control (IRC)
(MZD20-102)
• Convenient occupancy sensor and photocell integration Zone 1 Zone 2

• Autocal automatic photocell target level calibration


• Accepts external time clock input to provide an OFF Sweep
Photocell
Function or modify the partial OFF function (ODC0P)
Multi-Technology
Occupancy Sensor
(OSC20-M0W)
• Simplified integration with emergency systems
• Controls maximum lighting output for additional energy
savings potential and Task Tuning Low-Voltage
Switch
• Daylight switching, full range 1-10V dimming (RLVSW-4LW)

• Partial ON control for initial light level in either manual switch


or occupancy sensor auto modes
• Partial OFF control for minimum continuous light level
• Adjustable minimum light level shut off value
• Emergency input drives auxiliary zones to full

TYPICAL IRC INSTALLATION

68
INTEGRATED ROOM CONTROL (IRC) LOAD RATINGS
• 20A per relay, 120/277V
• 15A per relay, 347V
• 1-10VDC LED drivers, Fluorescent, non-dimmed and 1-10V dimmed
• 120mA power output for operation of occupancy sensors, photocells, etc.

ORDERING INFORMATION
ROOM-IN-A-BOX KITS - Order a Complete System with One Part Number
CAT. NO. DESCRIPTON
IRC Dimming Room Control Kit, includes Low Voltage devices; 2 Zone Room Controller w/(2) 1-10V outputs
RCD20-102 and (2) 120/277V relays, M/T Occupancy Sensor (OSC20-M0W), 4 Button Switch (RLVSW-4LW),
Photocell (ODC0P-00W), 120/277VAC, 50/60Hz
IRC Dimming Room Control Kit, includes Low Voltage devices; 3-Zone Room Controller w/(3) 1-10V outputs
RCD30-101 and (1) 120/277V relay, M/T Occupancy Sensor (OSC20-M0W), 4 Button Switch (RLVSW-4LW),
Photocell (ODC0P-00W), 120/277VAC, 50/60Hz
IRC Dimming Room Control Kit, includes Low Voltage devices; 2-Zone Room Controller w/(2) 1-10V outputs
RCD20-C02 and (2) 347V relays, M/T Occupancy Sensor (OSC20-M0W), 4 Button Switch (RLVSW-4LW),
Photocell (ODC0P-00W), 347VAC Canadian model, 50/60Hz
IRC Dimming Room Control Kit, includes Low Voltage devices; 3-Zone Room Controller w/(3) 1-10V outputs
RCD30-C01 and (1) 347V relay, M/T Occupancy Sensor (OSC20-M0W), 4 Button Switch (RLVSW-4LW),

Room Control | IRC


Photocell (ODC0P-00W), 347VAC Canadian model, 50/60Hz

INDIVIDUAL IRC MODELS


CAT. NO. DESCRIPTION
MZD20-102 IRC Dimming Version, 2 zone, 2 relay, 120V or 277VAC
MZD30-101 IRC Dimming Version, 3 zone, 1 relay, 120V or 277VAC
MZD20-C02 IRC Dimming Version, 2 zone, 2 relay, 347VAC
MZD30-C01 IRC Dimming Version, 3 zone, 1 relay, 347VAC

INTEGRATED ROOM CONTROL (IRC) LIGHTING CONTROLLER


The Integrated Room Control (IRC) Lighting Controller is a Decora® device for controlling non-dimmable
and dimmable luminaries connected to the IRC. The IRC Lighting Controller provides a unique control
station with multi-function capabilities available in a 4-button or simple 2-button configuration.

ORDERING INFORMATION
CAT. NO. DESCRIPTION
RLVSW-4LW 4-button dimming ON/OFF Controller for use with IRC System
RLVSW-2LW 2-button ON/OFF Controller for use with IRC System
RDGSW-2Ex* 2-button Color Change Kit
RLVSW-1LW 1-button ON/OFF Controller for use with IRC System
RDGSW-4Ex* Color Change Kits
RDGSW-2Fx* 2-Button Custom Engraved Color change Kit
RDGSW-4Fx* Engraved Color Change Kits
*Replace X to indiciate color: White (W), Ivory (I), Light Almond (T), Gray (G), Black (E) and Red (R).

www.leviton.com/les 69
HOSPITALITY KEY CARD SWITCHES
Leviton key card switches are designed to provide energy savings for the hospitality industry by ensuring that no devices are
left on when the room is not in use. These switches control electrical circuits by simply inserting or removing the guest’s
access card into the device. Both line voltage and low voltage switches are available for application flexibility.

FEATURES AND BENEFITS


• Functions as dependable vacancy sensor when guest leaves and removes card
• Reduce energy costs by ensuring circuits are ON only during occupancy (when keycard is in switch)
• Attractive low profile design with color change kit to meet the most common room designs or décor
• LED lighting illuminates the card slot for easy location in a dark room
• High Inrush Stability (H.I.S. Technology)
- Zero crossing circuitry optimizes relay operation for reliable, long-life operation
- Robust mechanical latching relay is durable for all load types
• No neutral model (HKSWP-GDX) is specially designed for retrofit applications where neutral wires are not available
• Low voltage model is compatible with applica­tions utilizing building automation systems, energy management
systems, and lighting control panels
• Fully rated to protect the entire circuit with UL Listing and 20A relay
Room Control | Key Card Switches

HOSPITALITY KEY CARD SWITCHES


DESCRIPTION CAT. NO.

Hospitality Key Card switch with color change kit, 120-277V HKSWP-0DX*
Hospitality Key Card switch with color change kit, 120-277V, no neutral HKSWP-GDX*
Hospitality Key Card switch with color change kit, 24V HKSWP-0LX*
Faceplate, Gray, 25 pack HKSWP-00G*
Faceplate, Ebony, 25 pack HKSWP-00E*
*All HKSWP models ship with the Color Change kit — includes a White, Ivory and Light Almond faceplate
HKSWP

70
www.leviton.com/les 71
GREENMAX® RELAY CONTROL SYSTEM
Smart Lighting Control
Designed for the contractor, specifier and end user, the GreenMAX Relay Control System offers the best performance,
reliability, flexibility and energy savings of any relay control available. GreenMAX easily integrates various lighting control
strategies like switching, dimming, behavior controls, scheduling, occupancy sensing and daylight harvesting To learn more
visit www.leviton.com/GreenMAX.

FEATURES
• Scalable solution offers future expansion opportunities
• California Title 24 2013 code compliance, including demand response
• ASHRAE Standard 90.1 2010 compliance
• Eligible for LEED certification points
Photocell Occupancy
• Daylight harvesting capabilities Sensor
- Dimming - Switching
- Open Loop - Closed Loop
0-10V BALLAST
• Highest Short Circuit Current Rating (SCCR) of 25,000A
at 277VAC for maximum equipment performance Loads

• Robust latching Relay Modules are rated 30A general

LumaCan
fluorescent ballast and 20A incandescent in 1-pole and GreenMAX 16 - Relay Cabinet
Centralized Control | GreenMAX®

2-pole configurations with the same footprint, available


with or without the Return to Closed (RTC) functionality
• 1-10 VDC dimming control with dimming relay modules Digital Switch - 1 button

• 1-10V and timed control using Leviton’s exclusive


behavioral design - use with low voltage sensors,
photocells and switches Digital Switch - 2 buttons
• Programming and monitoring of the system is
conveniently done with a portable Handheld Display
Unit (HDU) and simplified Behavior settings in the space Digital Switch - 4 buttons
being controlled rather than from the electrical room
• Modular system was designed to ship the empty cabinet
enclosure, complete with doors and covers, to the job site Photocell Occupancy
to make installation of the cabinet and conduits easier Sensor
• Communication over LumaCAN and Ethernet – to simplify
configuration and ensure start simplicity Remote Low Voltage Cabinet
• Accommodates low voltage inputs such as occupancy
sensors, photocells, contact closures, and switches Low Voltage Switch
• Wiring area covers and isolation barriers conceal the
circuit wiring and provide maximum arc flash protection
0-10V BALLAST
when installed allowing work to be done with power on
without chance of exposure to high voltage – no Arc Loads
GreenMAX 8 - Relay Cabinet
Flash Suit needed
• Custom engraving available on digital switches and wall
Keyswitch
plates
• Relay pulse control provides control of large mechanical
contactors Digital Switch - 4 Button Dimmer Control
• Easy updates—loading firmware is automated and only
requires plugging in a USB memory stick and pressing a
button
• System can be connected via Ethernet or LumaCAN networks
• All network connections are made with RJ45 connectors and cabling is standard CAT6
• Low Voltage Remote Input Card can be combined with LevNet RF Self-Powered Wireless
Solutions to create a wireless hybrid system of inputs
• All programming and configurations are stored in a MicroSD memory card, which eliminates
the need for non-volatile memory
• BMS interface through BACnet I/P

72
APPLICATIONS
• Heavy retrofit applications
• New construction projects
• Government facilities
• Office buildings
• Hospitals/medical offices
• Universities
• Restaurants
• Large campuses
• Any other location where centralized lighting
control, programming and monitoring are required

Command Module
LumaCAN Ethernet Twin 35W Main Low Voltage Communication Link
Port Port Power Processor 16-Input Card (Between Command
USB Port Supply Module and Relay

Centralized Control | GreenMAX®


Insert Panel)

Wiring
Diagram

Lock

Relay
Insert
Panel
Door with
Split Hinges
Right
Panel
Cover

Power and
Lighting
Left Panel 2-Pole Wire Way
Cover Relay

Grounding Manual
Points Actuator
Lower Ventilation
Cover

www.leviton.com/les 73
GREENMAX RELAY CABINETS
• GreenMAX cabinet has a 25,000A at 277 VAC Short Circuit Current
Rating (SCCR) for increased reliability and durability
• Empty cabinet enclosures ship separately from electronic
components – Command Module and Relay Insert Panel – making
the cabinets lighter and easier to handle and requiring less effort
to install
• Empty cabinet also provides unobstructed access to conduit entry
points and reduces the risk of damaging electronics
• Relay cabinets can hold 8, 16, 32 and 48 relays, each with unlimited
and flexible configuration capabilities; the 1-10 VDC dimming and
switching relay models can be installed in any available relay slot
• Increased arc flash protection—the cabinet door opens to expose
only the low voltage area of the cabinet
• Remote Low Voltage Panels allow the connection points of the
low voltage wiring enclosure to be installed closer to the devices it
serves, reducing wiring and labor costs and making commissioning
or troubleshooting easier
• Takes only eight screws to assemble the internal Relay Insert
Centralized Control | GreenMAX®

Panels and Command Module of a 48-Relay GreenMAX cabinet


• A single relay or group of relays can be separated by sliding an
isolation barrier between relays to eliminate the need for an
additional cabinet to handle emergency loads and allows voltages
from mixed sources in the same cabinet
• Native communication network protocols—BACnet/IP and Ethernet
—are built into each Command Module to offer unparalleled
connectivity; no additional devices are needed to communicate
with other products utilizing these protocols
• GreenMAX system connects together with CAT6 cable and RJ45
connectors; power is provided to devices over this network running
the LumaCAN protocol

GREENMAX RELAY MODULES


• All GreenMAX relay modules have a 25,000A at 277 VAC Short
Circuit Current Rating (SCCR) for increased reliability and durability
• Rated at 30A general fluorescent ballast and 20A incandescent,
HID, electronic ballast and LED
• All GreenMAX Relay Modules are 1-pole or 2-pole latching relay
types that reduce parasitic energy use. All relay modules are the
same physical size, allowing the optimal mix of relays to be
customized for each application
• Self-contained Dimming and Switching Relay Module in 1-pole
configurations features daylight harvesting capabilities
• All four wires required for 1-10V dimming ballast wiring connect
directly to the module—no additional control board required
• All relays are latching with a manual actuator that allows users to
manually bypass the system to turn lights ON or OFF without CPU
power

74
HANDHELD DISPLAY UNIT (HDU)
• Allows programming, system configuration, and scheduling to be
done in the space being controlled rather than the electrical room
to make commissioning and set-up functions easier
• Configure and control the entire GreenMAX system (or multiple
systems) from any convenient network access point—relay
cabinets, switches, or remote low voltage cabinets with just
one HDU
• Provides interface with all devices and relays in the system
• Can be stored in the cabinet or designated docking station
• Communicate via LumaCAN
• 7 hour run time on a single full charge
• Astronomical clock – sunrise/sunset
• HDU does not need to be connected to system during operation.
The full computing power of a PC remains in the palm of your hand
• Comes complete with a set of rechargeable batteries

Centralized Control | GreenMAX®


GREENMAX SWITCHES
• GreenMAX digital key switch provides secure button presses on
the network
• Manual control as required by energy codes
• Available in 1, 2, 4 and 8 button configurations, and key switch
version with custom engraved labeling available on switch buttons
and screwless wall plates
• Switch colors available: white, light almond, ivory, gray, black, and
red; all come with a matching wallplate. Keyswitch comes with
a stainless steel wallplate and tamper-resistant screws (tool
included)
• Each digital switch button has a green LED pilot light to report the
corresponding relay state
• Switches can be ganged together in wallboxes (multi-gang
wallplate sold separately)
• RJ45 connectors to provide inline connection to the LumaCAN
network
• Any 4-button switch model can be configured to control 0-10 VDC
dimming circuits
• Button assignments (temporary manual overrides with ability to
have daylight harvesting, dimming, & bi-level switching control at
the switch)
- ON* - BRIGHT - DIM - OFF
(optimal most used – dimming capabilities – used in offices)
- ON* - PRESET1 (on at 35%) - PRESET2 (on at 65%) - OFF
(optimal second most used – dimming capabilities at preset level
used in classrooms)
- ON/OFF Relay 1 - ON/OFF
Relay 2 - ON/OFF Relay 3 - ALL OFF (turns ON/OFF at full)
- ON1 - OFF1 - ON2 - OFF2
(bi-level switching – new timers or A/B switching – old timers)
• Easy to access port on top of switch provides connectivity for the
GreenMAX HDU
* Initiates daylight harvesting

www.leviton.com/les 75
PROGRAMMING GREENMAX WITH LIGHTING BEHAVIORS
LIGHTING CUSTOMIZATION
GreenMAX controls allow different Behavior settings to be programmed throughout the day. Using the HDU, any room
can be set with just a few button selections:

• Select the Behavior desired and time Behavior will take place
• Choose any additional Behavior transitions and the time transition will take place
• Optional override to sunrise/sunset astronomical clock prevents lights from activating prematurely in summer or too late
in winter
• Set Behaviors to scale on a daily, weekly, monthly or holiday schedule
• Up to 24 Behaviors per 24 hour period can be programmed and can be as close together as one minute

SIMPLE AND EASY PROGRAMMING


• Using the HDU, select the number on the screen corresponding with the desired Behavior
• Enter time and dates to be in effect and any corresponding Behavior Modifiers. Behaviors can be set for entire system or
individual rooms/relays

BEHAVIORS
Centralized Control | GreenMAX®

OCCUPANCY
NUMBER DESCRIPTION SENSOR PHOTOCELL SWITCH TIME
Lights turned ON with the switch.
B1 Can be turned OFF with switch. OFF - ON/OFF -
Occupancy Sensor will turn OFF upon vacancy.
Lights turned ON with the Occupancy Sensor.
B2 Can be turned OFF/ON with switch. ON/OFF - ON/OFF -
Occupancy Sensor will turn OFF upon vacancy.
B3 Occupancy sensor turns lights ON/OFF. ON/OFF - - -
B4 Switch ON/OFF. - - ON/OFF -
Time triggers a Blink Warn sequence, an OFF blink followed by a
variable ON delay.
B5 - - ON/OFF Blink/OFF
Switch interrupts sequence and starts override timer.
Will automatically turn OFF relay if override timer reaches zero.
B6 Turn ON at specific time. - - - ON
B7 Turn OFF at specific time. - - - OFF
Occupancy sensor turns ON lights with occupancy.
Measured light levels above Photocell trigger point turns OFF or keep lights
B8 ON/OFF OFF - -
OFF, below set-point allows control by Occupancy Sensor.
Occupancy Sensor turns OFF lights with vacancy.
Switch turns ON/OFF lights.
Measured light levels above Photocell trigger point turns OFF or keep lights
B9 OFF OFF ON/OFF -
OFF, below set-point allows control by Occupancy Sensor.
Occupancy Sensor turns OFF lights with vacancy.
Occupancy Sensor turns ON lights with occupancy.
Measured light levels above Photocell trigger point turns OFF or keep lights
B10 OFF, below set-point allows Occupancy Sensor control. ON/OFF OFF ON/OFF -
Switch can turn ON/OFF lights by over-riding Occupancy Sensor control.
Occupancy Sensor will turn OFF lights upon vacancy.
Switch ON/OFF.
B11 Measured light levels above Photocell trigger point turns OFF or keep lights - OFF ON/OFF -
OFF, below set-point allows Switch control.
Turn ON at specific time.
B12 Measured light levels above Photocell trigger point turns OFF or keep lights - OFF - ON
OFF, below set-point reliquishes control to the constant ON state.
Occupancy sensor turns lights partially ON. Switch turns lights ON full bright
B13 ON/OFF - ON/OFF -
or turns them OFF
Lights ON at minimum level. Occupancy sensor raises/lowers light level
B14 ON/OFF - - -
between Partial-ON and full ON

76
BEHAVIORS, CONT.
AUTO-PROMPT CUSTOMIZATIONS
NAME DESCRIPTION VALUE RANGE
2.5, 5, 10, 15, 30, 60, 90, 120
Switch OFF Delay When relay is turned ON with the switch, length of time before relay will automatically turn OFF.
minutes, and Constant ON
Occupancy Sensor 0, 0.5, 2.5, 5, 10, 20, 30
When vacancy is determined, length of time before relay will automatically turn OFF.
OFF Delay minutes
Photocell Delay Delay before action is taken after a Photocell trigger point has been crossed. 0, 0.5, 2.5, 5, 10, 20 minutes
Blink Warn -
The length of the OFF Blink used to notify occupants than an OFF sequence has been initiated. 0.5-25.4 seconds
Blink Duration
This period follows the Blink and lasts the length of the specified time. If button is pressed
Blink Warn - Delay during this period, the Delay timer stops and the Override Time starts. If no buttons are pressed, 1-254 minutes
the lights will turn OFF.
The relay will remain ON for the duration of this timer. A new Blink Warn sequence will be
Blink Warn -
initialized at the end of this period. If the relay had been OFF previously and a button is pressed to 1-254 minutes
Override Time
turn the relay ON, this timer will be started again.

DESCRIPTION CAT. NO. DESCRIPTION CAT. NO.


TUBS AND COVERS (ALL CABINETS ARE SURFACE MOUNT WITH A RELAYS
LOCKING DOOR)

Centralized Control | GreenMAX®


GreenMAX Latching Relay, 1-Pole RTC Basic RELAY-1CB
GreenMAX Relay Cabinet, 8-Relay Size, NEMA 1 R08TC-100
GreenMAX Latching Relay, 1-Pole dimming and RELAY-1DS
GreenMAX Relay Cabinet, 16-Relay Size, NEMA 1 R16TC-100 switching, 1-10VDC dimming, sinking, LED Control
GreenMAX Relay Cabinet, 32-Relay Size, NEMA 1 R32TC-100 GreenMAX Latching Relay, 1-Pole Basic RELAY-1TB
GreenMAX Relay Cabinet, 48-Relay Size, NEMA 1 R48TC-100 GreenMAX Latching Relay, 2-Pole RTC RELAY-2CB
COMMAND MODULES (INCLUDES POWER SUPPLY WITH MAIN GreenMAX Latching Relay, 2-Pole Basic RELAY-2TB
PROCESSOR UNIT, OPTION 24VDC LOW VOLTAGE INPUT CARD)
Blank Filler Module RELAY-BFM
Main Command Module, 100-277V AC, 50/60Hz, RPM00-300
no inputs, LumaCAN3 DIGITAL SWITCHES AND COLOR CHANGE KITS

Main Command Module with 8-Port Low Voltage RPM08-308 GreenMAX Digital Switch, 1-Button, LumaCAN3 RDGSW-1Cx*
Input Card, 100-277V AC, 50/60Hz, LumaCAN3 GreenMAX Digital Switch, 2-Button, LumaCAN3 RDGSW-2Cx*
Main Command Module with 16-Port Low Voltage RPM16-316 GreenMAX Digital Switch, 8-Button, LumaCAN3 RDGSW-8Cx*
Input Card, 100-277V AC, 50/60Hz, LumaCAN3
GreenMAX Digital Switch, 4-Button, LumaCAN3 RDGSW-4Cx*
PANEL INTERIORS (ALL PANELS ARE 16-POSITION, RATED 30A, 120-
GreenMAX Keyswitch RDGSW-1KS
230-277/347V AC, 50/60HZ)
GreenMAX 1-Button Color Change Kit RDGSW-1Ey**
Relay Insert Panel, Empty with 8 Empty Spaces R0800-000
GreenMAX, 8-Button Color Change Kit RDGSW-8Ey**
Relay Insert Panel, Empty with 16 Empty Spaces R1600-000
GreenMAX 2-Button Color Change Kit RDGSW-2Ey**
Relay Insert Panel with 16 1-Pole Basic Relays R1616-1CB
GreenMAX 4-Button Color Change Kit RDGSW-4Ey**
Relay Insert Panel with 16 1-Pole Dimming and R1616-1DS
Switching Relays GreenMAX 1-Button Engraved Color Change Kit RDGSW-1Fy**
Relay Insert Panel with 16 1-Pole Basic Relays R1616-1TB GreenMAX 2-Button Engraved Color Change Kit RDGSW-2Fy**
Relay Insert Panel with 16 2-Pole RTC Relays R1616-2CB GreenMAX 4-Button Engraved Color Change Kit RDGSW-4Fy**
Relay Insert Panel with 16 2-Pole Basic Relays R1616-2TB GreenMAX, 8-Button Engraved Color Change Kit RDGSW-8Fy**
HANDHELD DISPLAY UNIT (HDU) CABINET ACCESSORIES
Handheld Display Unit, Cabinet Mounting, LumaCAN3 RHDU1-300 GreenMAX Voltage Barriers for 8-Relay Cabinets RGBAR-008
Handheld Display Unit, Mounting Bracket Requires 2 RHDU1-001 GreenMAX Voltage Barriers for 16-, 32- and 48-Relay RGBAR-016
Gang Back Box Cabinets
REMOTE INPUTS WITH POWER SUPPLY (ALL CABINET POWER *Replace x with the following color codes — (W) White, (I) Ivory, (T) Light Almond.
SUPPLIES RATED 120-277V AC, 50/60HZ) **Replace y with the following color codes — (W) White, (I) Ivory (T) Light Almond,
(G) Gray, (E) Black, (R) Red
Remote Low Voltage Input Cabinet, 8 Inputs, NEMA 1 RLV08-308
Enclosure, LumaCAN3
Remote Low Voltage Input Cabinet, 16 Inputs, NEMA RLV16-316
1 Enclosure, LumaCAN3

www.leviton.com/les 77
TRACK LIGHT LIMITING PANEL (TLLP)
FEATURES
• Enables designer lighting to easily
meet energy code watt density requirements
• California Title 24 2013 Track Light
Supplementary Overcurrent Protection
Panel
• Assists track lighting schemes in
meeting energy code regulations
including CA Title 24 2013, ASHRAE Standard
90.1 2010 and City of Seattle guidelines
• Excellent for use in retail and
restaurant settings
• Simplifies load calculations by using
volt-ampere rating of the breaker
as opposed to calculated values on
Centralized Control | Track Light Limiting Panel

the track
• Reduces installation costs
• Available in 16 or 32 circuit panels
• NEMA 1 surface or flush mount enclosure
• Factory configured to your specifications
— arrives ready to install

ORDERING KEY

SPACES MOUNT VOLTAGE # OF NEMA 1 CIRCUIT


BREAKERS INSTALLED
16 = 16 Spaces F = Flush 1 = 120VAC
Mount Indicate 2-digit multiples of
32 = 32 Spaces 7 = 277VAC
2, available from 02-32*
S = Surface
Mount

NOTE: Specify breaker size and configuration on configuration form


NOTE: Completed configuration form must be accompanied with order
Available breaker sizes: 0.5A, 1A, 2A, 3A, 4A, 5A, 6A, 7A, 8A, 10A, 13A, 15A, 16A, 20A, 25A, 30A, 32A, 40A, 50A, 60A

78
EZ-MAX® PLUS RELAY CONTROL PANELS
EZ-MAX Plus relay lighting control panels pack power and performance in compact and cost-effective 8-circuit and 24-circuit
models. EZ-MAX Plus is the ideal solution for smaller, stand-alone applications that do not require the field configuration or
advanced networking features like the GreenMAX Relay Control systems.

Programming is easy with the EZ-MAX Plus with a large LCD screen on the panel or an off-line editor. EZ-MAX Plus includes
standard programming configurations for occupancy sensors and photocells as well as a built-in astronomical time clock
(ATC) with 101 major city and states programmed into the system.

Centralized Control | EZ-MAX® Plus

www.leviton.com/les 79
FEATURES
• Large, bright LCD screen with oversize buttons for easy programming
• Easy standard programming configuration:
- Occupancy sensors: manual-ON or auto-ON applications
- Photocells: interior or exterior application modes
- Photocell light level trip points: ON or OFF
• Built-in astronomical time clock and scheduler
- 101 major cities and states programmed for easy astronomical setup
- Sunrise/sunset time clock events
• Auto detection/auto assign of installed network switches
• Enable/disable of low voltage and digital input devices minimizes power consumption
• Clearly labeled access points allow installer to locate optimum knock-out locations
• ON/OFF timed control of LED - use with low voltage sensors, photocells and switches
• UL and cUL Listed Industrial Control Equipment and Emergency Lighting Equipment for 120V, 277V and 347V Panels
• ASHRAE Standard 90.1 2010 compliant
• CA Title 24 compliant and listed
Centralized Control | EZ-MAX® Plus

• Rated for 100% load capacity


• Backed by a limited 10-year warranty on relays and a limited 2-year warranty on panels

APPLICATIONS
• Low voltage control
• Site lighting
• Daylight harvesting
• Occupancy sensor integration
• Parking garage/parking lot lighting
• Smart replacement of time clock/contactor installations
• Any application requiring reliable and cost-effective automatic on/off lighting control

DESCRIPTION CAT. NO.


EZ-MAX Plus 8 Relay Panel, 120V, 277V, and 347V Control Input, No Relays R08BD-000
EZ-MAX Plus 8 Relay Panel, 120V, 277V, and 347V Control Input, (4) 1-pole 30A (NO/NC) Latching Relays R08BD-L04
EZ-MAX Plus 8 Relay Panel, 120V, 277V, and 347V Control Input, (8) 1-pole 30A (NO/NC) Latching Relays R08BD-L08
EZ-MAX Plus 8 Relay Panel, 120V, 277V, and 347V Control Input, (8) 20A 2-pole (NO/NC) Latching Relays R08BD-208
EZ-MAX Plus 24 Relay Panel, 120, 277, and 347V Control Input, No Relays R24BD-000
EZ-MAX Plus 24 Relay Panel, 120V, 277V and 347V Control Input, (16) 1-pole 30A (NO/NC) Latching Relays R24BD-L16
EZ-MAX Plus 24 Relay Panel, 120V, 277V, and 347V Control Input, (24) 1-pole 20A (NO/NC) Latching Relays R24BD-L24
EZ-MAX Plus 24 Relay Panel, 120V, 277V and 347V Control Input, (16) 2-pole 20A (NO/NC) Latching Relays R24BD-216
EZ-Max Plus 24 Relay Panel, 120V, 277V, 347V Control Input, (24) 2-pole 20A (NO/NC) Latching Relay R24BD-224
EZ-MAX Plus 8 Relay Panel, 230V Control Input, No Relays R08BF-000
EZ-MAX Plus 8 Relay Panel, 230V Control Input (8) 1-pole 30A (NO/NC) Latching Relays R08BF-L08
EZ-MAX Plus 24 Relay Panel, 230V Control Input, No Relays R24BF-000

80
EZ-MAX PLUS RELAY CARDS
EZ-MAX Plus Panels use individual relay cards for each circuit allowing for the most flexibility in matching the relay type to
your specific load requirements. The benefit of a single relay card for a single circuit allows an infinite arrangement of relay
types to position in your system and supports individual replacement should the need ever occur.

• For maximum equipment protection, standard 30A relay card has a Short Circuit Current Rating (SCCR) of 20,000A
• Relay cards individually replaceable
• Mechanical attachment to panel of each relay card is with a single screw
• Listed for use with ballasted loads
• From the panel, each relay card can be controlled as follows:
- Override ON
- Override OFF
- Locked Override ON
- Locked Override OFF
- Timed ON
- Timed Override OFF
• Backed by a limited 10-year warranty on relays

Centralized Control | EZ-MAX® Plus


EZ-MAX PLUS RELAY CARDS
DESCRIPTION CAT. NO.
EZ-MAX Relay, 120-277VAC, 1-Pole 30A NO/NC, with Manual Override RELAY-L30
EZ-MAX Relay, 208-480V, 2-Pole 20A NO RELAY-2PL
EZ-MAX Relay 20A NO, 347 RELAY-347

ACCESSORIES*
DESCRIPTION CAT. NO.
Low Voltage Switch Adapter for GE 5-wire switches
RAC00-2SB
(installed at the switch itself, cabinet has terminations for ON/OFF/LED/+1/com)
xx Button, Low Voltage Switch, White 00LVS-xxW*
xx Button, Digital Switch, White ZMDSW-xxW*
Outdoor Photocell, 1-10V, 0-250 FC PCOUT-000
Indoor Photocell, 1-10V, 0-100 FC PCIND-000
Atrium Photocell, 1-10V, 0-1000 FC PCATR-000
Skylight Photocell, 1-10V, 0-2000 FC PCSKY-000

* For a complete range of occupancy sensors for use with EZ-MAX Plus, refer to www.leviton.com/occupancysensors

www.leviton.com/les 81
EZ-MAX PLUS VS. GREENMAX:
THE BEST SYSTEM FOR SPECIFIC APPLICATIONS
Leviton offers multiple options in relay control for contractors, developers, architects and facility managers. Please see below
for details on which system offers the most value for different applications.

EZ-MAX PLUS GREENMAX


• Small scale, simple installations with 8 or less relays • Specified structures with over 8 relays to control
to control • Multiple lighting applications such as site lighting, individual
• Primarily time clock control for common areas and offices/tenants, daylight harvesting, dimming control, etc.
site lighting • Varying needs for many zones of lighting control and
• Provides simple lighting control strategies throughout ON/OFF times throughout the structure/campus
the structure

EZ-MAX PLUS GREENMAX


FEATURES
• Smart replacement for time clock/contactor installations • Switching
Centralized Control | EZ-MAX® Plus

• Low-voltage control devices • Dimming


• Site lighting • Behavior controls
• Simple daylight harvesting • Scheduling
• Occupancy sensor integration • Occupancy sensing
• Parking garage/parking lot lighting • Daylight harvesting
• Any application requiring reliable and cost-effective • Scalable for future expansion
automatic lighting control • Building Mangement System interface
• Room control

EZ-MAX PLUS GREENMAX


COMMON APPLICATIONS
• Restaurants (fast food, café, sit-down, etc) • Multi-building, large-scale campuses
• Small commercial office spaces • Schools (K-12, college)
• Strip malls with simple site lighting • Large indoor shopping malls
• Free-standing shops • Convention centers
• Parking garages • Hotels
• Houses of worship • Hospitals
• State/federal parks • Large office buildings
• Department stores
• Theme parks
• Government buildings

82
www.leviton.com/les 83
SECTOR® INTELLIGENT DIGITAL LIGHTING CONTROL SYSTEM
The Sector Intelligent Digital Lighting Control System combines occupancy sensing, daylighting and flexible dimming lighting
control in one conveniently integrated system that saves time, money and energy. This topology-free, polarity-free system
allows the entire network to be installed using the same wiring for all components and accessories, making it one of the
easiest lighting control systems to install. All components are on a single bus, with accessories connected to the network,
not the ballast. The Sector family of products provides a scalable solution that offers maximum flexibility and coverage in any
application – from a single room to a campus of buildings in retrofit or new construction projects. To learn more, visit
www.leviton.com/Sector

FEATURES
SECTOR INTELLIGENT DIGITAL LIGHTING CONTROL SYSTEM
• Topology free
• California Title 24 2013 and ASHRAE Standard 90.1 2010 compliant
• Polarity free — Class 1 or Class 2 Wiring/standard building supported wiring in same conduit as power wiring
• No special terminations or installation requirements
• Scene control switches
• Behavior support
• Occupancy sensor feedback to BMS systems
• Personal workspace lighting control from user’s personal computer for user comfort
Distributed Control | Sector®

• Easy to commission — ultimate flexibility in design, installation and configuration


• Easy to design, easy to install and easy to maintain
• The Sector 5-button digital switch has five lighting levels for switched lighting applications:
- Max — Lights are at maximum level, system is in override status
- Bright— Turns individual zones ON and OFF depending on daylighting levels
- Dim — Manual control for dimmable lights
- On — Lights are on for Daylight Harvesting
- Off — Lights are completely OFF
• Sector 2 Button Switch - ON/OFF only
• Ideal Uses: Hospitals, offices buildings, medical offices, universities, labs, restaurants, government facilities and any other
location that could benefit from the cost savings and energy efficiency of a controlled lighting environment.

ADVANTAGES
• Easy to Use with 1-10V LED drivers
• Simple to Design — scalable system for small and large applications; devices that connect directly to the network can be
installed anywhere in the system
• Easy to Install— topology free, polarity independent, and operates on standard Class 1 or Class 2 wiring throughout the en-
tire systems to reduce installation costs by as much as 35% or more; standard wire is found in every contractor’s inventory
• Flexible to Commission— configuration and commissioning is completed from the PC application without physically having
to go to each device
• Ultimate time-saving design flexibility – easily integrate various lighting control strategies—switching, distributed dimming,
scheduling, occupancy sensing, and daylight harvesting – in one system offering future expansion opportunities
• Easy energy code compliance and eligibility for LEED points
• Control and customization from occupant’s desktop as well as remote control and administrator software interface
• SectorFlex system controls Sector and non-Sector 1-10V ballasts or LED dimmers by any manufacturer, allowing for
flexibility in implementation
• Minimal installation time — color coded easy-insert connectors simplify wiring and minimize installation time
• Miswire protection prevents lamp failure if wired incorrectly
• Smooth fade through dimming range of 1% to 100% for flicker-free dimming
• Lamps turn on at any dimmed level without flashing to full brightness, extending lamp life and providing a better user
experience
• Non-volatile memory restores all ballast settings after power failure

84
SECTOR RELAY
• Provides switching control for non-dimming devices and 1-10V control
for sinking and sourcing controllable loads like LED drivers, ballasts and
incandescent dimmers
• Used for both switching only loads and dimming loads controllable with
a 1-10 control signal
• Provides additional system design options, allowing control of ballast
incandescent, LED, cold cathode or other sources that may attempt a
1-10VDC control input

SECTOR BUS CONTROLLER


• Contains the brain and the power supply for the Sector system in a
single component
• Controls a maximum of 64 devices on a system with the ability to
expand and include a maximum of 250 systems

SECTOR OCCUPANCY SENSORS

Distributed Control | Sector®


• Turns lights ON/OFF based on vacancy or occupancy
• Multi-technology and infrared (PIR) models available
• Self-adjusting settings continually analyze and adjust sensitivity, timer
operation and long-term performance, reducing user complaints

SECTOR PHOTOCELL
• Daylight harvesting capabilities offer consistent lighting at desired level
for greater visual comfort

www.leviton.com/les 85
SECTOR DIGITAL SWITCH
• User controls desired light level at the push of a button
• 5 button (MAX, BRIGHT, DIM, OFF Daylight Harvesting ON) and 2 button (ON, OFF) available
• 2 button (ON/OFF)

SECTOR HANDHELD REMOTE


• User controls desired light level at the push of a button (ON, MAX, BRIGHT, DIM, OFF)
• Controls lighting levels up to 25 feet from anywhere in the room

SECTOR LOW VOLTAGE INTERFACE


• Allows integration of Sector System with non-Sector occupancy sensors and photocells
• Provides for cost and install time savings by utilizing existing site components

SECTORNET SOFTWARE
• Personal Dimming Option (PDO) — Individual control for the lights above a user’s
workspace right from their desktop PC
• Central control — Facility personnel and lighting administrators can re-configure control
as needed with Illustrator layout tool
Distributed Control | Sector®

• A computer is only needed to initially configure the system. Afterward, Sector can be
ran as an independent system
• Commissioning quickly associates fixtures to Sector devices for easy configuration that
can be remotely controlled
• Data acquisition for energy usage monitoring
• Ladderless commissioning — remotely configure and control system components
• 3 levels of load shed allow user to automatically adjust power consumption across the
entire system by simply clicking a button

86
2 Button 2 Button
Switch Switch
Remote
Occupancy
Sensor 2 Button
Switch
Photocell

Photocell Non-Dim Device


1-10V Signage Occupancy
LED Fixture Sensor

Power
1-10V
Sector
LED Fixture Relay 1-10V
LED Fixture
~Voltage
Line ~
Line

SectorNet Wiring
Sector Voltage ~ Line

Min 18AWG
Relay Voltage
Sector
Line Relay Sector
Relay
~ Voltage
Max Longest Run - 1000’

Area 2 Area 4 Area 6 Area 8


Dimmer

Distributed Control | Sector®


Areas 2 - 7
1-10V

CLASS 1 OR 2 WIRING
LED Fixture
SectorNet Network

Sector 0-10V
Relay Control
& Power
Occupancy
~
Line
Sensor
Voltage
2 Button
Switch
2 Button
Switch Sector
2 Button Relay
Switch ~
Line
SectorNet Network

Voltage
Occupancy
Sensor

Area 7
Occupancy
SectorNet Network

Sensor

Occupancy 1-10V Photocell


Sensor LED Fixture
1-10V
SectorNet Network

LED Fixture
1-10V Sector
Relay 1-10V LED
Sector LED Fixture
Fixture
Relay Sector
Relay
~
Line
Line Voltage ~Line
~Voltage
To other Bus Controllers
Line Voltage
~ Voltage
Sector
*Power Relay
Terminate each end Supply
of the LumaCAN Bus *Power
network by pushing Controller Supply
blue button Bus
Area 1 Area 3 Area 5 Controller
~

LumaCAN Network CLASS 2 WIRING LumaCAN Network

Wiring may follow any Max 32 input


Up to 8 areas Max distance between Up to 250 devices are
topoology, daisy chain, 64 SectorNet devices (Switch,
per Bus Bus Controller & last supported on each
star, home run etc. devices per Photocell, or
Controller device on line is LumaCAN subnet.
or “T” at any point in Bus Controller Occupancy
1,000’/304 Meters A Bus Controller counts
the network. Sensor
as (1) device
SectorNet Network
is also poliarity free!
* Max 256mA per Power Supply

www.leviton.com/les 87
ORDERING INFORMATION
DESCRIPTION CAT. NO.
Sector Bus Controller/Power Supply,
SBP00-00M
120-277V, 50/60Hz
Sector Relay, 120-347V 20A Output,
SBCS0-L00
120-277V, 50/60Hz Input
Sector 4-Module Enclosure (to hold a
SEN04-000
maximum of 4 Bus Controllers)
Sector PIR Occupancy Sensor, White,
OSC04-ISW
450SF
Sector Multi-Technology Occupancy
OSC20-MSW
Sensor, White, 2000 SF
Sector Photocell ODC0P-0SW
5-Button Digital Switch, White SDS00-15W
2-Button Digital Switch, White SDS00-12W
Artwork Kit, Scene 1, Raise, Lower,
SDSP1-R5W
Max, OFF
Artwork Kit, Scene 1, Max, OFF SDSP1-M2W
Distributed Control | Sector®

Artwork Kit, Scene 1, OFF SDSP1-02W


Artwork Kit, Scene 1, Scene 2, Scene
SDSP4-05W
3, Scene 4, OFF
Artwork Kit, Zone 1 Toggle, Zone 2
SDSP4-G1W
Toggle, All OFF
Artwork Kit, High, Low, OFF SDSP4-G2W
Sector Handheld Infrared Remote
SHH00-000
Controller
USB-to-LumaCAN Adapter SLM00-000
SectorNET Administrative Software SIF00-000
SectorNET Client Software SIFPD-000
SectorNET Low Voltage Interface
Module for Occupancy Sensors and SLIQD-000
Photocells
SectorNET Low Voltage Interface
SLIQS-000
Module for Switches, 5-Channel

88
www.leviton.com/les 89
SMARTER METERING. SMARTER CONTROL. REAL SAVINGS.
THE BENEFITS OF SUBMETERING
VerifEye delivers a comprehensive line of leading-edge submeters, communication products, and software solutions as the
key building blocks to help you better manage costs and conserve energy.

Develop your strategic energy management plan using revenue grade real-time energy usage information to measure,
monitor, and manage operations to improve your bottom line. From tenant billing to energy measurement & verification
(M&V) software solutions, VerifEye offers cost effective scalability and integration to provide you with the solution you
need today and in the future.

For additional energy savings, combine VerifEye with Leviton lighting controls for a complete energy management
solution from a single source.

VERIFEYE DELIVERS ACCURATE INFORMATION FOR:


• Tenant billing/cost allocation
• Load profiling & benchmarking
• Measurement & verification (M&V)
• Energy conservation programs
• LEED projects
• Government mandates
VerifEye™ Submetering Solutions

• AMR/BMS/EMS integration
• Renewable and bi-directional applications
• Compliance with green building initiatives

90
EXCELLENCE COMES STANDARD
• Open architecture design provides easy integration with third party building management system (BMS) platforms
• UL 916 Listed or recognized for Energy Monitoring Equipment and UL 61010 Electrical Equipment for Measurement
and Control
• Installer friendly, reverse phase LED indicator arrow and power and load indicators provide installation diagnostics by visually
confirming that the product is properly installed and functioning
• Leviton Series 1000, 2000 and 3500 meters are available as an indoor steel or outdoor NEMA 4X enclosure at the same low
price; Series 4000 and 4100 meters available as DIN rail and NEMA 4X
• VerifEye offerings include a wide range of meters to meet the needs of any application. Automated data collection solutions
and energy reporting and analysis software to easily and intelligently manage energy consumption
• Solutions are confidently backed by a best in the industry 5 year warranty

LEVITON METERING PHILOSOPHY


Consultative Approach
Each project is tailored to each customer’s needs - from a basic meter hardware system to an advanced communication
system that includes BAS/BMS integration

Scalable System
Options for future upgrades and additions are available with Leviton’s flexible solution—no need to purchase an entire

VerifEye™ Submetering Solutions


new system

Open Protocol
Ease of communication with the use of Leviton Data Acquisition Communication equipment

Automated Data Collection

On-Site Software

ModHopper
Add to any VerifEye system
for wireless metering
EMH
Energy Monitoring Hub*
BillSuite

18/2 Wire

Building Management System

HD Pulse Web-Based Software


Module
CAT5 CAT5

Ethernet Advanced Communication All-in-One


Pulse Only Meters
Meter Meters Meter & Hub
Energy Manager and BMO 2.0*
*BMO 2.0 is free with purchase of a VerifEye Hub

Series 1000 Series 2000 Series 3500 Series 4000/ Series 8000 EMH+ All-in-One
Series 4100 Meter & Hub*

3rd Party
Protocols: Protocols: Protocols:
- ModBus RTU - ModBus RTU - ModBus RTU
- ModBus TCP/IP - ModBus TCP/IP - ModBus TCP/IP
- BACNet IP - BACNet IP - Optional BACNet IP
Water Gas Steam

*BMO 2.0 is FREE with purchase of a VerifEye hub

www.leviton.com/les 91
VERIFEYE METERS

MMU Mini Meter Flush Mount 0.5% Mini Meter Mini Meter Outdoor Series 8000 EMH+ All-In-One
Meter & Hub*

Residential Residential/Commercial
Series 8000
Specifications Multiple Point
Mini Meter™ 0.5% Mini Meter High Density EMH+ All-In-One
Kits Kits Meter Meter & Hub*
kWh Meter kWh Meter
1PH 2W 3PH 3W Delta
1PH 3W WYE 3PH 3W WYE
Phase/Wiring 1PH 3W 1PH 3W
3PH 3W Delta 1PH 2W
?

3PH 4W WYE 3PH 4W WYE


120/208
VerifEye™ Submetering Solutions

120/240
Voltage 208-480
120/208/240 120/208/240 240/416
Configurations 120, 240, 277VAC
277/480
480*

Amperages 100-200A 200A 100-5000A

Meter Totals: kWh, kVARh, kW, kVAR, kVA,


Measuring Voltage L-L, L-N, Current, Power Factor, Peak and
kWh kWh
Parameters Present Demand, Frequency Per Phase: Voltage L-L,
L-N, Current, Power, Power Factor

Embedded line ModBus TCP ModBus/RTU, ModBus/TCP,


Communications
Isolated powered AMR ModBus RTU TCP/IP, PPP, HTTP/HTML, FTP,
Protocol
Pulse Output equipment, (RS-485) NTP, XML, SNMP-Trap.
(Standard)
wireless network BACnet IP Optional BACnet/IP

Current
Split Core Split Core Split Core
Transformers Solid Core
Solid Core Solid Core Solid Core
Options
OEM Module
Indoor Plastic Indoor Flush Mount
Enclosure Indoor JIC Steel
Flush Mount NEMA 1 Indoor Surface Indoor Plastic Surface Mount
Options NEMA
Outdoor NEMA 4X Mount
MMU NEMA 4X
LCD or Mechanical
Display Type Counter LCD Local LCD, Scroll LCD

C12.20 +/- 0.5% C12.20 0.5% with C12.1 1% +/- 0.5% from 2%
Accuracy C12.20 +/- 0.5%
with paired CTs paired CTs to 100% of full scale
Medium, 2-4 Meters
Multiple Meter 3PH: 8 points
Large, 5-8 Meters _ _
Unit (MMU) 2PH: 12 points
Configurations Extra-Large, 1PH: 24 points
9-19 Meters
Last Reading - Last reading - 1 to 60 min
Last Reading - Last Reading - Cumulative Data in User Selectable
Data Storage
Cumulative Cumulative 15 min Intervals (default 15 min)

* With potential transformer - consult factory for availability.


**VerifEye BMO 2.0 software is included at no cost with purchase of any VerifEye Data Acquisition Hub

92
Series 1000 Series 1000 Series 2000 Series 2000 Series 3500 Series 3500 Series 4000/4100 Series 4000/4100
Indoor Outdoor Indoor Outdoor Indoor Outdoor Indoor Outdoor

Commercial
Commercial
and Industrial
Series 4100
Series 4000 Industrial
Series 1000 Series 2000 Industrial ModBus ModBus RTU and
Single Phase Three Phase Series 3500 Meter Kits BACNet MS/TP
Meter Kits Meter Kits Multi-Function Ethernet Meter Kits kWh Meter Meter Kits
kWh Meter with Optional Demand Advanced kWh Meter with Communication

Phase/Wiring 1PH 2W 1PH 3W 3PH 4W WYE 3PH 3W/4W 3PH 3W 3PH 4W 3PH 3W/4W

120/208
Voltage 120 120/208

VerifEye™ Submetering Solutions


120/240 Universal Voltage (120-480V) Universal Voltage (90-600)
Configurations 277 277/480
277/480

Split Core: 100, 200,400, 800A


Amperages 100-800A 100-1200A 100-5000A
Rogowski: 20-5000A

kWh
kWh
kWh kW (peak demand reset) Meter Totals: kVARh, kW, kVAR, kVA,
Measuring Optional kW
Optional kW Meter total: kVAR, kVA, Power Factor & kW Voltage L-L, L-N, Current, Power Factor,
Parameters (peak demand
(peak demand reset) By Phase: Volts, Watts, Amps, Power Factor Frequency
reset)
Interval Data

Isolated Pulse Output


Communications
Isolated Pulse Isolated Pulse Ethernet ModBus/RTU ModBus/RTU and
Protocol
Output Output ModBus TCP/IP Isolated Pulse Output BACnet MS/TP
(Standard)
BACnet IP

Current Split Core .333V secondary output only


Split Core Split Core Split Core
Transformers Rogowski Coil: lengths available in 12”, 18” and
Solid Core Solid Core Solid Core
Options 24”

Indoor
Indoor JIC Steel NEMA 1 Indoor Indoor Indoor
Enclosure Steel NEMA 1 Outdoor JIC Steel NEMA 1 DIN Rail Mount DIN Rail Mount
Options Outdoor NEMA 4X Outdoor Outdoor Outdoor
NEMA 4X MMU JIC Steel NEMA 4X NEMA 4X NEMA 4X Enclosure
NEMA 1
Display Type Local LCD Local LCD, Scroll LCD, Scroll LCD, Scroll

Accuracy C12.20 +/- 0.5% C12.20 +/- 0.5% C12.10 and C12.20 +/- 0.5% C12.20 0.5% C12.20 0.5%

Medium:
Multiple Meter 2-4 meters
Unit(MMU) - Large: 5-8 meters - - -
Configurations Extra-Large:
9-16 meters

Last Reading - Cumulative Peak Demand Last Reading - Cumulative Peak Demand Last Reading - Present and Peak Demand for kW
Data Storage
with Key Reset (optional) with Key Reset Data in 15 min Intervals and kVAR

www.leviton.com/les 93
MINI METER™
EQUITABLE TENANT BILLING
Some multi-tenant residential properties include energy costs in rental fees and generally charge tenants for energy based
on the square footage occupied. To be truly equitable, tenants should pay only for what they actually use. With Leviton Mini
Meters, building managers can easily track and allocate energy usage costs fairly to multiple tenants, as well as recoup
energy expenses from common-use areas (parking lots, hall lighting, etc.). Tenants benefit by paying only for the energy they
use; and when they focus on conserving energy, they can see direct financial benefits from their efforts.

FEATURES
• kWh Meter
• 120V 1PH 2W and 120/208/240V 1PH 3W
• 100-200 Amps
• Pulse Output - standard feature
• Available in indoor flush mount and surface mount enclosures and NEMA 4X outdoor individual meter enclosures and
Multiple Meter Units (MMUs) from 2 to 19 meters
• Select surface mount and flush mount models include built in tamper-proof switch or built-in wireless AMR and temperature
sensing capabilities
• 0.5% revenue grade accuracy class
• Use with solid core CTs to achieve 0.5% accuracy. Also available with split core CTs.
VerifEye™ Submetering Solutions

• Up to three sets of CTs per phase can be paralleled per meter with no multipliers
• Components of Mini Meter Kits are UL/cUL Listed Energy Usage Monitor per CCN FTRZ

Indoor Flush Mount Indoor Surface Mount Outdoor


Mini Meter Mini Meter Mini Meter

94
MINI METER KITS
Note: Kits include meter, specified enclosure and required current transformers

MINI METER KITS - INDOOR FLUSH MOUNT ENCLOSURE


VOLTAGE AMPS CTS INCLUDED CAT. NO.
100A MK240-1SW
120/208V 3W or 120/240V 1PH 3W (Split Phase) 2 Solid CTs
200A MK240-2SW

MINI METER KITS - OUTDOOR ENCLOSURE


VOLTAGE AMPS CTS INCLUDED CAT. NO.
100A MO240-1SW
120/208V 3W or 120/240V 1PH 3W (Split Phase) 2 Solid CTs
200A MO240-2SW
100A MO240-01W
120/208V 2PH 3W or 120/240V 1PH 3W (Split Phase) 2 Split CTs
200A MO240-02W

0.5% MINI METER KITS - INDOOR FLUSH MOUNT ENCLOSURE*


VOLTAGE AMPS CTs INCLUDED CAT. NO.
120/208/240V 2PH 3W 6P201-C02

VerifEye™ Submetering Solutions


120/208/240V 2PH 3W (includes Time of Use (TOU)* enabled kWh
6W201-C02
Transceiver and Tamper Proof Switch)
120/208/240V 2PH 3W (includes Time of Use (TOU) & Temperature 200A 2 Solid CTs
6W201-D02
enabled kWh Transceiver and Tamper Proof Switch)
120/208/240V 2PH 3W (includes Time of Use (TOU) & Delta
6W201-E02
Temperature enabled kWh Transceiver)

0.5% MINI METER KITS - INDOOR SURFACE MOUNT ENCLOSURE*


VOLTAGE AMPS CTs INCLUDED CAT. NO.
120/208/240V 2PH 3W 6PSMT-C02
120/240V 1PH 3W (includes Time of Use (TOU*) enabled kWh
MMSMT-C02
Transceiver and Tamper Proof Switch)
120/240V 1PH 3W (includes Time of Use (TOU) and Temperature 200A 2 Solid CTs
MMSMT-D02
enabled kWh Transceiver and Tamper Proof Switch)
120/240V 1PH 3W (includes Time of Use (TOU) and Delta Temperature
MMSMT-E02
enabled kWh Transceiver and Tamper Proof Switch)

WIRELESS REPEATER
DESCRIPTION CAT. NO.
Repeater, 5V, includes 5VDC 1A plug-in power supply and internal backup battery T101R-05V

WIRELESS DATA CONCENTRATING ACCESS POINTS (DCAPS)**


DESCRIPTION CAT. NO.
Data Concentrating Access Point (DCAP), Low Capacity (150 meter points max), built-in radio receiver T201E-151
DCAP, High Capacity (1000 meter points max), built-in radio receiver T201E-102
*For a complete wireless Automatic Meter Reading (AMR) system, data transceivers and other wireless network components (DCAPs and Repeaters) are required
as dictated by building construction.
TOU = Time of Use, providing 15-minute time-stamped kWh interval data
**All DCAPs and Gateways shipped with 6VDC, minimum 1.5 Amp power supply, Ethernet cable and USB cable

www.leviton.com/les 95
MULTIPLE METER UNITS (MMUs)
For both retrofit and new construction, Leviton Multiple Meter Units (MMUs) are fast and easy to install. They come pre-wired
per project configuration sheets with clearly labeled connections, minimizing the electrical installation time, another great
money saving feature.

All Leviton MMUs are UL Listed assemblies, giving your customers extra assurance at no extra cost. Choose from an indoor
steel model in 4/8/16 unit single- or three-phase configurations utilizing Series 2000 meters or a weatherproof outdoor
enclosure in 4/8/19 unit single-phase configurations utilizing Mini Meters. If your application requires a
different configuration, Leviton is ready to help.
VerifEye™ Submetering Solutions

Series 2000 Multiple Meter Unit (MMU) Mini Meter Multiple Meter Unit (MMU)

All MMUs are customizable and field upgradable for individual projects.
Each meter order requires submittal of a Configuration Form.
Go to leviton.com/verifeye for more information.

96
ORDERING INFORMATION

MINI METER MMUS SERIES 2000 MMUS


VOLTAGE DESCRIPTION CAT. NO. VOLTAGE DESCRIPTION CAT. NO.
MEDIUM MINI METER MMU, 2-4 METERS MEDIUM SERIES 2000 MMU, 2-4 METERS
2 Dual Element Meters 6M202-CFG 2 Three Element Meters 2M202-CFG
120/240V 120/208V
3 Dual Element Meters 6M203-CFG 3 Three Element Meters 2M203-CFG
1PH 3W 3PH 4W
4 Dual Element Meters 6M204-CFG 4 Three Element Meters 2M204-CFG
2 Dual Element Meters 6M302-CFG 2 Three Element Meters 2M402-CFG
120/208V 277/480V
3 Dual Element Meters 6M303-CFG 3 Three Element Meters 2M403-CFG
3PH 4W 3PH 4W
4 Dual Element Meters 6M304-CFG 4 Three Element Meters 2M404-CFG
LARGE MINI METER MMU, 5-8 METERS LARGE SERIES 2000 MMU, 5-8 METERS
5 Dual Element Meters 6L205-CFG 5 Three Element Meters 2L205-CFG

120/240V 6 Dual Element Meters 6L206-CFG 120/208V 6 Three Element Meters 2L206-CFG
1PH 3W 7 Dual Element Meters 6L207-CFG 3PH 4W 7 Three Element Meters 2L207-CFG

VerifEye™ Submetering Solutions


8 Dual Element Meters 6L208-CFG 8 Three Element Meters 2L208-CFG
5 Dual Element Meters 6L305-CFG 5 Three Element Meters 2L405-CFG

120/208V 6 Dual Element Meters 6L306-CFG 277/480V 6 Three Element Meters 2L406-CFG
3PH 4W 7 Dual Element Meters 6L307-CFG 3PH 4W 7 Three Element Meters 2L407-CFG
8 Dual Element Meters 6L308-CFG 8 Three Element Meters 2L408-CFG
EXTRA-LARGE MINI METER MMU, 9-19 METERS, EXTRA-LARGE SERIES 2000 MMU, 9-16 METERS,
NEMA 4X ENCLOSURE NEMA 4X ENCLOSURE
9 Dual Element Meters 6X209-CFG 9 Three Element Meters 2X209-CFG
10 Dual Element Meters 6X210-CFG 10 Three Element Meters 2X210-CFG
11 Dual Element Meters 6X211-CFG 11 Three Element Meters 2X211-CFG
12 Dual Element Meters 6X212-CFG 120/208V 12 Three Element Meters 2X212-CFG
13 Dual Element Meters 6X213-CFG 3PH 4W 13 Three Element Meters 2X213-CFG
120/240V 14 Three Element Meters 2X214-CFG
14 Dual Element Meters 6X214-CFG
1PH 3W
15 Dual Element Meters 6X215-CFG 15 Three Element Meters 2X215-CFG
16 Dual Element Meters 6X216-CFG 16 Three Element Meters 2X216-CFG
17 Dual Element Meters 6X217-CFG 9 Three Element Meters 2X409-CFG
18 Dual Element Meters 6X218-CFG 10 Three Element Meters 2X410-CFG
19 Dual Element Meters 6X219-CFG 11 Three Element Meters 2X411-CFG
9 Dual Element Meters 6X309-CFG 277/480V 12 Three Element Meters 2X412-CFG
10 Dual Element Meters 6X310-CFG 3PH 4W 13 Three Element Meters 2X413-CFG
11 Dual Element Meters 6X311-CFG 14 Three Element Meters 2X414-CFG
12 Dual Element Meters 6X312-CFG 15 Three Element Meters 2X415-CFG
13 Dual Element Meters 6X313-CFG 16 Three Element Meters 2X416-CFG
120/208V
14 Dual Element Meters 6X314-CFG
3PH 4W
15 Dual Element Meters 6X315-CFG
16 Dual Element Meters 6X316-CFG
17 Dual Element Meters 6X317-CFG
18 Dual Element Meters 6X318-CFG
19 Dual Element Meters 6X319-CFG

www.leviton.com/les 97
SERIES 8000 MULTI-POINT HIGH DENSITY METERS
The Series 8000 Multi-Point High Density Meters are designed to meter high density appli­cations such as multi-tenant
office and residential build­ings, medium-sized retail stores and institutional facilities and branch circuit monitoring. For easy
data accessibility, the Series 8000 design is based on an open protocol network to transmit data over ModBus and BACnet.
Combining revenue-grade electrical submetering with building automation communications technology, the Series 8000
Meter complies with all regulatory electric safety and communications requirements and meets stringent ANSI 0.5 %
Accuracy Class standards.

• Allows for revenue grade metering of up to 24


individual circuits in one device
• Monitors up to 24 current transformers—
- 8 circuits, 3 phase loads
- 12 circuits, 2 phase loads
- 24 circuits, 1 phase loads
• Branch circuit monitoring
• 100-5,000 Amp current transformers
• Native communications protocol—ModBus TCP,
ModBus RTU (RS-485) and BACnet IP standard
• Measures kW hours, kW demand, volts, amps
Series 8000 Meter
VerifEye™ Submetering Solutions

• Interval and net metering


• Configurable via Ethernet or ModBus RTU network
to BMS or VerifEye software solutions

ORDERING INFORMATION CHOOSING BETWEEN A WIRING


SERIES 8000 MULTI-POINT HIGH DENSITY METERS HARNESS AND TERMINAL STRIPS
VOLTAGE DESCRIPTION CAT. NO. • Wiring harnesses offer a less labor
RESIDENTIAL intensive solution when all CTs are
120/208/240V Phase Config 3x2 with Wiring Harness S8120-032 located in one panel like in a multi-family
high rise project. This eliminates the need
120/208/240V Phase Config 6x2 with Wiring Harness S8120-062
to extend CT wires out of the panel.
120/208/240V Phase Config 9x2 with Wiring Harness S8120-092
• Terminal strips are ideal for installers
120/208/240V Phase Config 12x2 with Wiring Harness S8120-122 who prefer to land each wire and not
120/208V Phase Config 8x3 with Terminal Strips S8UTS-083 use a color-coded wiring harness. For
120/208V Phase Config 12x2 with Terminal Strips S8UTS-122 CTs located in different panels or different
120/208V Phase Config 24x1 with Terminal Strips S8UTS-241 locations with a switchboard, terminal
120/208V Phase Config 8x3 with Wiring Harness S8UWH-083 strips offer an easier solution with the
ability to extend the current transformer
120/208V Phase Config 12x2 with Wiring Harness S8UWH-122
wiring back to the meter location for
120/208V Phase Config 24x1 with Wiring Harness S8UWH-241
termination. Terminal strip models also
COMMERCIAL & INDUSTRIAL carry a slightly higher cost and should be
277/480V Phase Config 8x3 with Terminal Strips 277TS-083 considered with the project budget.
277/480V Phase Config 12x2 with Terminal Strips 277TS-122
277/480V Phase Config 24x1 with Terminal Strips 277TS-241
277/480V Phase Config 8x3 with Wiring Harness 277WH-083
277/480V Phase Config 12x2 with Wiring Harness 277WH-122
277/480V Phase Config 24x1 with Wiring Harness 277WH-241
POTENTIAL TRANSFORMER (OPTIONAL)
480V Delta Delta PTs with Enclosure S480V-011

98
SERIES 1000 SINGLE PHASE METERS
• kWh meter with optional Peak Demand functionality (includes Reset Key)
• 100 - 800 Amps
• Isolated Pulse output—standard feature
• Large LCD Display
• ANSI 0.5% revenue grade accuracy class
• Utilizes split and solid core current transformers (CTs) that are certified to all revenue grade accuracy standards
• Up to three sets of CTs per phase can be paralleled per meter with no multipliers

VerifEye™ Submetering Solutions


Series 1000 Series 1000
Indoor Outdoor

ORDERING INFORMATION
SERIES 1000 SINGLE PHASE METER KITS
Note: Kits include meter, specified enclosure and required current transformers

INDOOR ENCLOSURE OUTDOOR ENCLOSURE


CTS CTS
VOLTAGE AMPS INCLUDED CAT. NO. VOLTAGE AMPS INCLUDED CAT. NO.
100 1K120-01W 100 1O120-01W
200 1K120-02W 200 1O120-02W
1 Split CT 120V 1PH 2W 1 Split CT
400 1K120-04W 400 1O120-04W
120V 1PH 2W
800 1K120-08W 800 1O120-08W
100 1K120-1SW 100 1O240-01W
1 Solid CT 120/208V 1PH 3W or
200 1K120-2SW 200 1O240-02W
120/240V 1PH 3W 2 Split CTs
100 1K240-01W 400 1O240-04W
2 Split CTs (Split Phase)
200 1K240-02W 800 1O240-08W
120/208V 1PH 3W or
400 1K240-04W 100 1O277-01W
120/240V 1PH 3W 2 Split CTs
800 1K240-08W 200 1O277-02W
(Split Phase) 277V 1PH 2W 1 Split CT
100 1K240-1SW 400 1O277-04W
2 Solid CTs
200 1K240-2SW 800 1O277-08W
100 1K277-01W
200 1K277-02W
1 Split CT
400 1K277-04W
277V 1PH 2W
800 1K277-08W
100 1K277-1SW
1 Solid CT
200 1K277-2SW

www.leviton.com/les 99
SERIES 2000 THREE PHASE METERS
• kWh meter with optional Peak Demand functionality (includes Reset Key)
• 120/208V or 277/480V 3PH 4W WYE only
• 100 - 1200 Amps
• Pulse output—standard feature
• Large LCD Display
• Revenue grade accuracy: 0.5% accuracy class
• Utilizes split and solid core current transformers (CTs) that are certified to all revenue grade accuracy standards
• Up to three sets of CTs per phase can be paralleled per meter with no multipliers
VerifEye™ Submetering Solutions

Series 2000 Series 2000


Indoor Outdoor

ORDERING INFORMATION
SERIES 2000 THREE PHASE METER KITS
Note: Kits include meter, specified enclosure and required current transformers

INDOOR ENCLOSURE OUTDOOR ENCLOSURE


CTS CTS
VOLTAGE AMPS INCLUDED CAT. NO. VOLTAGE AMPS INCLUDED CAT. NO.
100 2K208-01W 100 2O208-01W
200 2K208-02W 120/208V 3PH 200 2O208-02W
120/208V 3PH 400 3 Split CTs 2K208-04W 4W WYE kWh 400 2O208-04W
4W WYE kWh 800 2K208-08W Meter 800 2O208-08W
Meter 1200 2K208-12W 1200 2O208-12W
3 Split CTs
100 2K208-1SW 100 2O480-01W
3 Solid CTs
200 2K208-2SW 277/480V 3PH 200 2O480-02W
100 2K480-01W 4W WYE kWh 400 2O480-04W
200 2K480-02W Meter 800 2O480-08W
277/480V 3PH 400 3 Split CTs 2K480-04W 1200 2O480-12W
4W WYE kWh 800 2K480-08W
Meter 1200 2K480-12W
100 2K480-1SW
3 Solid CTs
200 2K480-2SW
100 2K208-01D
120/208V 3PH 200 2K208-02D
4W WYE Demand 400 2K208-04D
Meter 800 2K208-08D
1200 2K208-12D
3 Split CTs
100 2K480-01D
277/480V 3PH 200 2K480-02D
4W WYE Demand 400 2K480-04D
Meter 800 2K480-08D
1200 2K480-12D

100
SERIES 3500 MULTI-FUNCTION ETHERNET METERS
• Communications protocol:
- ModBus TCP/IP or BACnet IP
- Isolated pulse output
- Ethernet
• Universal voltage for 120-480V
• Measured Parameters
- Total Meter: - Per Phase:
- kWh/kW - Voltage L-N
- kVAh - Current
- kVA and kVAR - Watts
- Power Factor - VA, VAR
- Line Frequency - Power Factor
- Voltage L-L Series 3500 Meter
• Large LCD display with scroll feature
• ANSI 0.5% accuracy class revenue-grade accuracy
• Installation diagnostics
• Low voltage detection
• Real time clock with battery backup for TOU reading

VerifEye™ Submetering Solutions


• Use with split core or solid core CTs
• Up to three sets of CTs can be paralleled per meter with no multipliers
• Indoor JIC steel and outdoor (NEMA 4X) enclosure options
• UL/cUL Listed Energy Usage Monitor per CCN FTRZ

ORDERING INFORMATION
SERIES 3500 MULTI-FUNCTION ETHERNET METER KITS
INDOOR ENCLOSURE OUTDOOR ENCLOSURE
CTS CTS
VOLTAGE AMPS INCLUDED CAT. NO. VOLTAGE AMPS INCLUDED CAT. NO.
100 3KUMT-01M 100 3OUMT-01M
200 3KUMT-02M 200 3OUMT-02M
400 3KUMT-04M 400 3OUMT-04M
800 3 Split CTs 3KUMT-08M 800 3 Split CTs 3OUMT-08M
208-480VAC
1600 3KUMT-16M 208-480VAC 1600 3OUMT-16M
3P 3W/4W
3P 3W/4W
(with ModBus 3000 3KUMT-30M 3000 3OUMT-30M
(with BACnet)
TCP/IP
5000 3KUMT-50M 5000 3OUMT-50M
100 3KUMT-1SM 100 3OUMT-1SM
200 3 Solid CTs 3KUMT-2SM 200 3 Solid CTs 3OUMT-2SM
400 3KUMT-4SM 400 3OUMT-4SM

NOTE: Kits include meter, specified enclosure and required current


transformers

www.leviton.com/les 101
EMH+ ALL-IN-ONE METER AND HUB*
The VerifEye™ EMH+ combines an onboard revenue-grade power meter and Data Acquisition Hub in a flexible, all-in-one pack-
age. This simple and effective energy solution can be used to meet energy codes and mandates and is ideal for new con-
struction and commercial buildings.

• Simplicity—A complete metering system for any application


• Easy to Install—Reduces installation time and cost with
integrated meter and data acquisition capabilities
• More Features, Lower Cost—Costs up to 30% less than other
bundled meter and data acquisition devices
• Scalable—Employs other VerifEye solutions for future
upgrades
• Free Web-Based Software—Uses free online energy data
visualization BMO 2.0 software*
• Data Collection
- Logs and collects data on user selected intervals
- Non-volatile memory stores data until the next scheduled
upload or manual download
• Compatible with VerifEye BMO 2.0* online software allowing
VerifEye™ Submetering Solutions

users to quickly access energy consumption information


from a web-based platform
• Tracks real-time energy usage for demand response programs EMH+ All-In-One Meter & Hub*
• Meter data can be transferred to energy dashboards, kiosks
and software applications
• Up to 32 ModBus meters can be added downstream
• Supports BACNet and other protocols on one device
• Seamlessly integrates with BMS and BAS systems
• Monitors performance of critical systems such as lighting
and HVAC
• Set alarms notifications for targeted levels and view graphical
and historical data

LCD TOUCH SCREEN FEATURES


• Similar SmartPhone layout
• System set up from touch screen
• View live data from the EMH+ and other associated meters

ORDERING INFORMATION
EMH+ ENERGY MONITORING HUB*
AMPS CTS INCLUDED CAT. NO.
100A A8814-1S3
200A A8814-2S3 *VerifEye Building Manager Online (BMO) 2.0
300A A8814-3S3 software is included at no cost with the purchase
400A A8814-4S3 of VerifEye EMH+ All-In-One Meter and Hub.

600A 3 Split CTs A8814-6S3


800A A8814-8S3
1600A A8814-163
3000A A8814-303
5000A A8814-503

102
SERIES 4000 INDUSTRIAL MODBUS METER KITS
• Kits include meter, specified enclosure and split core and Rogowski Coil
current transformers
• Industrial Temperature Range -22-58°F (-30-70°C)
• 50/60 Hz
• 90-600V versatility including 347V (L-N) and 600V (L-L) with fewer
models to stock
• ANSI 12.20 0.2% accuracy, IEC 62053-22 Class 0.2S
• Options for 100, 200, 400m 800 and 800A split core CTs and Rogowski
CTs (20-5000A)
Series 4000 Indoor
• DIN Rail Mount
• Energy monitoring for AMR/BAS/BMS/EMS systems
• Tenant cost allocation
• Energy conservation and cost reduction
• Green building initiatives and government mandates
• Measurement and verification
• Load profiling and benchmarking

VerifEye™ Submetering Solutions


ORDERING INFORMATION
SERIES 4000 INDOOR METER KITS - DIN RAIL MOUNT
VOLTAGE AMPS CTS INCLUDED CAT. NO.
Universal 3PH 3W/4W 100 4KUMR-01M
Universal 3PH 3W/4W 200 4KUMR-02M
3 Split CTs
Universal 3PH 3W/4W 400 4KUMR-04M
Universal 3PH 3W/4W 800 4KUMR-08M
Universal 3PH 3W/4W 20-5000 3, 12” Rogowski Coil CTs 4KUMR-R12
Universal 3PH 3W/4W 20-5000 3, 18” Rogowski Coil CTs 4KUMR-R18
Universal 3PH 3W/4W 20-5000 3, 24” Rogowski Coil CTs 4KUMR-R24

SERIES 4000 OUTDOOR NEMA ENCLOSURE


VOLTAGE AMPS CTS INCLUDED CAT. NO.
Universal 3PH 3W/4W 100 4OUMR-01M
Universal 3PH 3W/4W 200 4OUMR-02M
3 Split CTs
Universal 3PH 3W/4W 400 4OUMR-04M
Universal 3PH 3W/4W 800 4OUMR-08M
Universal 3PH 3W/4W 20-5000 3, 12” Rogowski Coil CTs 4OUMR-R12
Universal 3PH 3W/4W 20-5000 3, 18” Rogowski Coil CTs 4OUMR-R18
Universal 3PH 3W/4W 20-5000 3, 24” Rogowski Coil CTs 4OUMR-R24

SERIES 4000 COMPONENTS


AMPS DESCRIPTION CAT. NO.
100 CTV01-K21
200 CTV02-K21
1 Split CT
400 CTV04-K40
800 CTV08-K40
- Fuse Pack, 1/2A, 600VAC, slow blow CTV00-FK3
20-5000 12” Rogowski Coil CTs CRV50-K62
20-5000 18” Rogowski Coil CTs CRV50-K93
20-5000 24” Rogowski Coil CTs CRV50-KC2

www.leviton.com/les 103
SERIES 4100 BIDIRECTIONAL MODBUS RTU AND BACNET
MS/TP METER KITS
The VerifEye Series 4100 Bidirectional ModBus RTU and BACNet MS/TP Meter
Kits feature bidirectional monitoring specifically designed for renewable energy
applications. The Series 4100 Meter Kits measure power imported from the
utility grid and power exported from renewable energy source like solar panels.
The Series 4100 Meter Kits are available in a standalone DIN rail mount or NEMA
4X enclosures and come with either split core or flexible rope-style Rogowski
Current Transformers (CTs).

• Bidirectional monitoring
• Industrial temperature range: -22-158°F (-30-70°C) Series 4100 Indoor

• 50/60 Hz
• 90-600V versatility including 347V with fewer models to stock
• Options for 100, 200, 400, and 800A Split Core CTs and Rogowski CTs (20-5000A)
• DIN rail mount for easy installation
• One device serves multiple locations
• User-enabled password protection to protect meter from tampering
• Bright, backlit LCD for installation in dark areas and viewing real time data
VerifEye™ Submetering Solutions

• Energy monitoring for AMR/BAS/BMS/EMS systems


• Renewable energy applications such as solar panels and wind
• System integration via ModBus RTU or BACnet MS/TP
- RS-485 Serial
• CSI approval for California Solar Initiative

ORDERING INFORMATION
SERIES 4100 BIDIRECTIONAL MODBUS RTU AND BACNET MS/TP METER KITS

INDOOR DIN RAIL MOUNT MODBUS METER KITS OUTDOOR NEMA ENCLOSURE - MODBUS METER KITS
VOLTAGE AMPS CTS INCLUDED CAT. NO. VOLTAGE AMPS CTS INCLUDED CAT. NO.
100 4DUMR-01B 100 41OUM-01B
200 4DUMR-02B 200 41OUM-02B
Split Core CTs Split Core CTs
Universal 400 4DUMR-04B Universal 400 41OUM-04B
3PH 3W/4W 3PH 3W/4W
800 4DUMR-08B 800 41OUM-08B
ModBus ModBus
RTU 20-5,000 12” Rogowski Coil CTs 4DUMR-12R RTU 20-5,000 12” Rogowski Coil CTs 41OUM-12R
20-5,000 18” Rogowski Coil CTs 4DUMR-18R 20-5,000 18” Rogowski Coil CTs 41OUM-18R
20-5,000 24” Rogowski Coil CTs 4DUMR-24R 20-5,000 24” Rogowski Coil CTs 41OUM-24R

INDOOR DIN RAIL MOUNT BACNET MS/TP METER KITS OUTDOOR NEMA ENCLOSURE - BACNET MS/TP METER KITS
100 4DUBM-01B 100 41OUB-01B
200 4DUBM-02B 200 41OUB-02B
Split Core CTs Split Core CTs
Universal 400 4DUBM-04B Universal 400 41OUB-04B
3PH 3W/4W 3PH 3W/4W
800 4DUBM-08B 800 41OUB-08B
BACnet BACnet
MS/TP 20-5,000 12” Rogowski Coil CTs 4DUBM-12R MS/TP 20-5,000 12” Rogowski Coil CTs 41OUB-12R
20-5,000 18” Rogowski Coil CTs 4DUBM-18R 20-5,000 18” Rogowski Coil CTs 41OUB-18R
20-5,000 24” Rogowski Coil CTs 4DUBM-24R 20-5,000 24” Rogowski Coil CTs 41OUB-24R

104
CURRENT TRANSFORMERS
The better the equipment, the better the measurement. Leviton meters utilize highly accurate current transformers for
revenue-grade performance certified to ANSI standards. Competing products use current sensors that do not provide the
same level of performance. Leviton Meter Kits include Split Core or Solid Core Current Transformers (CTs) for high-quality,
long-term accuracy and reliability. For added safety, all Leviton current transformers come with built-in voltage suppression
devices that prevent hazardous voltages from developing on CT secondaries should they become disconnected from a meter
with load current present.

Compact and cost-effective solid core CTs slip over power lines to measure the electrical current flowing through the line.
They are compact and cost effective. For solid core CT installation, power must be de-energized and the circuit opened, in
order to slip the CT over the power line.

ORDERING INFORMATION
SOLID CORE—FOR USE WITH SERIES 8000 METERS,
MINI METERS AND MMUS ONLY
AMP DESCRIPTION CAT. NO.
Solid Core, 0.67”, Black CDE01-K11
Solid Core, 0.67”, Blue CDE01-L11
Solid Core, 0.67”, Red CDE01-R11
100:0.1A
Solid Core, 0.72”, Black CDA01-K12

VerifEye™ Submetering Solutions


Solid Core, 0.72”, Blue CDA01-L12
Solid Core, 0.72”, Red CDA01-R12
Solid Core, 0.67”, Black CDE02-K11
Solid Core, 0.67”, Blue CDE02-L11
Solid Core Current Transformers
Solid Core, 0.67”, Red CDE02-R11 100A, 200A, 400A available
200:0.1A
Solid Core, 0.72”, Black CDA02-K12
Solid Core, 0.72”, Blue CDA02-L12
Solid Core, 0.72”, Red CDA02-R12
400:0.1A Solid Core, 1.5”, Black CDF04-K24

SPLIT CORE—SERIES 1000, 2000, 3500, 8000 METERS


AND SERIES 2000 (MMUS) ONLY
100:0.1A Split Core, .75” x .75” CTD01-K16
200:0.1A Split Core, 1” x 1” CTD02-K16
400:0.1A Split Core, 1.5”, x 1.5” CTD04-K23
800:0.1A Split Core, 3” x 3.5” CTC08-K46
1200:0.1A Split Core, 4” x 6” CTC12-K46
1600:0.1A Split Core, 4” x 6” CTC16-K96 Split Core Current Transformers
100A-5,000A available
3000:0.1A Split Core, 5” x 7” CTC30-57B**
5000:0.1A Split Core, 5” x 7” CTC50-57B**

SPLIT CORE - FOR USE WITH SERIES 4000 INDUSTRIAL


MODBUS METER KITS ONLY
100:0.333V Split Core, 1.6” x 2.1” CTV01-K21
200:0.333V Split Core, 2.2” x 2.8” CTV02-K21
400:0.333V Split Core, 6” x 5.2” CTV04-K40
800:0.333V Split Core, 6” x 5.2” CTV08-K40
Split Core Current Transformers
100A-800A available
ROGOWSKI COIL—FOR USE WITH SERIES 4000 INDUSTRIAL
MODBUS METER KITS ONLY
Rogowski Coil, 12” CRV50-K62
20-5000A Rogowski Coil, 18” CRV50-K93
Rogowski Coil, 24” CRV50-KC2

*Consult factory for availability.


System Accuracy: ±1% of reading from 10% to 100% of the rated Rogowski Coil Current Transformer
current of the CTs, accomplished by matching the CTs with electronics and 20A-5,000A available
calibrating them as a system.

www.leviton.com/les 105
VERIFEYE COMMUNICATION PRODUCTS

nergy Monitoring
E EMB Hub EMB HubLite High Density Flex I/O Module ModHopper
Hub (EMH) Pulse Module

Data Data Data Input/ Input/


Wireless ModBus/
Acquisition Acquisition Acquisition Output Output
Pulse Transceiver
Specifications

Hubs Hubs Hubs Module Module


High
Energy
EMB EMB Density Flex I/O
Monitoring ModHopper*
Hub* HubLite* Pulse Module*
Hub (EMH)*
Module*
A8812 A8810 A7810 A8911 A8332 R9120
ModBus RTU
ModBus TCP
ModBus TCP
VerifEye™ Submetering Solutions

TCP/IP
TCP/IP
PPP
PPP
Protocols

HTTP/HTML
HTTP/HTML
FTP ModBus RTU
FTP
NTP
NTP
XML
XML
SNMP-Trap
SNMP-Trap
BACnet IP
BACnet IP

Use with EMH to take Designed specifically for


advantage of plug-in wireless submetering
Use with an Ethernet (LAN) connection to push-or- communication
Applications

pull data via HTTP, XML, FTP, or any custom protocol Collect meter data from
Use with ModHopper for multiple buildings over
Connect to web-based (IP-based) software wireless communication long distances
dashboards, energy information management “Self-managed” mesh
systems and demand response systems Push-or-pull meter data network keeps system
to VerifEye kiosks and functioning with high
software applications reliability

HOW TO SELECT THE APPROPRIATE DATA ACQUISITION HUB


Configured Requires
4 Pulse 8 Flex for Leviton Separately
ModBus ModBus Inputs Inputs Energy Ordered
TCP RTU Onboard On Board* Manager Power Supply
A8812-001 EMH X X - X X -
A8812-000 EMH
X X - X - -
(non-configured)
A8810-000 EMB Hub X X - - - X
A7810-000 EMB HubLite X - X - - X
* Pulse, analog, status and resistive.

*VerifEye BMO 2.0 is free with purchase of a VerifEye Hub.

106
METERING COMMUNICATIONS SYSTEMS
To create a data network between Leviton submeters and stakeholders
(BAS, third party billing, Leviton Energy Manager software, etc.), Leviton
offers Metering Communication Systems. These solutions transmit data
from meters to end systems, creating a seamless transition between data
collection and data display. Leviton Metering Communications Systems
also enable facilities to create metering systems that can easily share data
through open protocols such as ModBus, and IP-based data transfer through
HTTP/FTP of .csv or XML files. The results are robust and reliable networks
scalable to accommodate future expansion, with data made accessible from
any internal or external location.

DATA ACQUISITION HUBS*


ENERGY MONITORING HUBS
Data Acquisition Hubs, including the Energy Monitoring Hub (EMH), EMB
Energy Monitoring Hub*
and EMB HubLite, are intelligent, flexible data acquisition servers allowing
users to collect energy data from meters and environmental sensors.
Designed to connect to IP-based applications such as enterprise energy
management, demand response and smart grid programs, Hub servers allow

VerifEye™ Submetering Solutions


you to connect thousands of energy points, benchmark energy usage and
reduce energy costs.

• Collects and logs data from connected wired or wireless devices based on
user-set intervals
• Pushes or pulls data via HTTP, XML, FTP or any custom protocol using an
Ethernet (LAN) connection
• No software required: information can be accessed through any web
browser in any location
• Plug and play connectivity EMB Hub*

• Compatible with nearly any front-end software platform allowing


customers to use a variety of reporting tools
• Push or pull meter data to energy dashboards, kiosks and software
applications
• Monitor performance of critical systems (lighting, HVAC, PDUs,
inverters, etc.)

ORDERING INFORMATION
DATA ACQUISITION HUBS*
DESCRIPTION CAT. NO.
EMB HubLite*
Energy Monitoring Hub – Configured for Leviton Energy Manager A8812-001
Energy Monitoring Hub – Non-Configured A8812-000
EMB Hub A8810-000
EMB HubLite A7810-000
Power Supply for EMB Hub and EMB HubLite YBM07-010
Refer to page 102 for the EMH+ Energy Monitoring HUB - features integrated meter and HUB.

*VerifEye BMO 2.0 is included at no cost with the


purchase of any VerifEye Data Acquisition Hub.

www.leviton.com/les 107
INPUT/OUTPUT MODULES
HIGH DENSITY PULSE MODULE
The High Density Pulse Module provides a convenient way to expand a VerifEye metering system by connecting the HD Pulse
Module to an Energy Monitoring Hub (EMH) and/or ModHopper for system expansion. The HD Pulse Module accepts up to
23 standard pulse sensors and can function as a slave device with any ModBus master. This data can easily be integrated to
a network of other critical energy sensors to provide a comprehensive energy monitoring solution. The HD Pulse Module is
ideal for applications with a high density of pulse output devices, giving users access to meters that would previously require
multiple modules.

• External communications handled via shielded twisted pair 18-22 gauge


wire allowing communication up to 4,000 ft and pulse input
communications up to 200 ft (consult factory for longer runs) using
18-24 gauge control wire
• DIN or wall mounting make installations quick and easy
• Device verification—LED indicators for each pulse input allow for fast
indication and verification of pulses to reduce installation and
troubleshooting time
• Non-volatile memory retains configuration and pulse count totals during
power failures for reliable data collection and retention
• Easily add pulse meters to ModBus network for a scalable, open protocol High Density Pulse Module
VerifEye™ Submetering Solutions

solution
• Field upgradable firmware for user-friendly future upgrades and expansion

FLEX I/O MODULE


The Flex I/O Module is a cost-effective way to collect data from meters or sensors and bring the information into a ModBus
network or energy monitoring system. As a stand-alone or bundled package, the Leviton Flex I/O Module can be incorporated
with data acquisition and metering devices to provide a cost-effective energy monitoring solution. The Flex I/O Module is
compatible with virtually any ModBus master, allowing customers the flexibility to use it in existing ModBus networks. Use
with the Leviton Energy Monitoring Hub (EMH).

• Easily add meters and sensors to the ModBus network


• 8x user selectable inputs
• 2X output relays for manual controls or pulse replication
• Non-volatile memory
• Industrial temperature range of -22-158°F (-30-70°C)
• LEDs for visual verification/status reduce installation and
troubleshooting time
• Din or wall mount for easy installation
• Field upgradable firmware for user-friendly future upgrades and expansion
Flex I/O Module

ORDERING INFORMATION
INPUT/OUTPUT MODULES
DESCRIPTION CAT. NO.
High Density Pulse Module, 23 Inputs A8911-000
Flex I/O Module, 8 User Selectable Inputs, 2 Relay Outputs A8332-000

108
WIRELESS MODBUS/PULSE TRANSCEIVER
ModHopper
The ModHopper is designed with breakthrough mesh technology that makes connecting ModBus RTU (RS485) and pulse
devices simple and cost effective. Our “smart” ModHopper transceivers eliminate the need for costly wiring runs allowing
users to wirelessly capture meter data in the most challenging retrofit and campus environments. Collect meter points in
existing buildings with minimum down-time or disruption of day-to-day operations.

• Designed specifically for wireless metering and VerifEye submetering


solutions for guaranteed compatibility
• No software or programming required and devices automatically
configure when powered, reducing labor costs and installation time
• Wireless “mesh” network—self-healing, self-optimizing for ease
of installation and maintenance
• Connect up to 32 ModBus and 2 pulse devices per ModHopper for
the ultimate expandable solution
• Long distance communication (3,000ft indoor/14 miles LOS Outdoors)
for flexibility of placement and easier future expansion
• Multiple independent network capability
• Reliable, constant two-way communication and packet verification

VerifEye™ Submetering Solutions


• Point to multi-point communication
• Field upgradable firmware for user-friendly future upgrades and expansion
ModHopper

ORDERING INFORMATION
WIRELESS MODBUS/PULSE TRANSCEIVER
DESCRIPTION CAT. NO.
ModHopper and Power Supply R9120-500

VERIFEYE NEMA COMMUNICATION BUNDLES


Leviton VerifEye NEMA Communication Bundles combine VerifEye’s Data Acquisition Products into one enclosure for a
Leviton-exclusive, all-in-one-bundled communication solution for indoor use. All VerifEye NEMA communication bundles have
one part number and are factory pre-assembled for ease of ordering eliminating the need for field assembly.

ORDERING INFORMATION
NEMA COMMUNICATION BUNDLES
DESCRIPTION CAT. NO.
Energy Monitoring EMB Hub with Line Voltage Power Supply, NEMA 4X Enclosure A8810-PS1
Energy Monitoring EMB HubLite with Line Voltage Power Supply, NEMA 4X Enclosure A7810-PS1
HD Pulse Module with Line Voltage Power Supply, NEMA 4X Enclosure A8911-PS1
Flex I/O Module with Line Voltage Power Supply, NEMA 4X Enclosure A8332-PS1

VerifEye BMO 2.0 is included at no cost with the


purchase of any VerifEye Data Acquisition Hub.

www.leviton.com/les 109
VERIFEYE SOFTWARE PRODUCTS

BillSuite Building Manager Online (BMO) 2.0 Energy Manager

Tenant Billing Software Measurement & Verification (M&V) Software


Specifications

Building Manager
BillSuite Energy Manager
Online (BMO) 2.0*
VerifEye™ Submetering Solutions

LBSSW BMOSW LEMS8


Allows users to quickly access energy
consumption information via a web- Analyzes, formats and reports data
Functions

based platform gathered from VerifEye Submetering


Primary

Automates the tenant billing process by Solutions


eliminating manual meter readings Plot charts and view data quickly
without any custom software installed Users log in to Energy Manager website
on a PC—simply log on to the BMO and access data and reports in real-time
website
Monitor energy consumption of each
tenant or whole building on a 24/7 basis Illustrates information in real time
Meters can be in a basement, wire Delivers simple graphical interface Includes an automatic reporting system
Key Features

closet or individual unit for plotting energy information and and an instant alarm notification system
Generate bills from any PC— identifying anomalies and peak demand Produces customized reports to suit
requires Windows 7 or better in near real time precise requirements
Monthly and periodic billing reports for Uploads 15 minute interval data and Collects information from 1 to 60 min
any or all VerifEye submeters displays raw data in a line graph intervals for in-depth tracking
Energy profile to identify peak demand Reporting based on 15 min intervals
and energy waste

Identify cost saving measures that can


Investigate potential building problems lead to greater profitability
Generate monthly electricity bills for
and alarms easily
each tenant, which reflect actual energy Discover energy inefficiencies that may
usage Select date ranges to display be difficult to see
information in intervals from one year
Improve cash flow and increase net Establish baselines, budgets and
to as little as an hour
operating income allocation of energy use and cost within
Key Benefits

Export your 15 min interval data to .csv an enterprise to track and analyze goals
Eliminate uncertainty of variable utility
files and performance
costs
Configure VerifEye HUB communication Develop responsible environmental goals
Delegate energy usage accountability
products remotely and conservation measures while
to tenants
Add or change the data recording measuring and managing facility’s
Improve tenant satisfaction, retention carbon footprint
interval, alarm thresholds, even the
and property values
device name Provide outstanding communication
Identify and fix energy waste, reducing and support, enabling facilities to have
Graph up to 4 different parameters for
overall costs the most advanced and intuitive energy
trending patterns
management reporting in the industry

*VerifEye BMO 2.0 is included at no cost with the purchase of any VerifEye Data Acquisition Hub.

110
VERIFEYE SOFTWARE
SAVE ENERGY, REDUCE COSTS, BE SUSTAINABLE
VerifEye software solutions provide simple, effective, turn-key solutions to monitor energy in real time. Designed to
seamlessly integrate with VerifEye submetering hardware and communication systems, VerifEye software allows facilities
to introduce smarter energy management strategies, saving money and resources.

VERIFEYE SOFTWARE INCLUDES:


• Tenant Billing
- BillSuite - provides individual tenant billing capabilities to ensure accurate and complete recovery of tenant energy costs
• Measurement & Verification (M&V)
- Building Manager Online (BMO) 2.0—web-based interval data collection software platform
- Energy Manager—energy monitoring platform which interprets submeter data and exports real-time reports in selected
time increments, stretching from hour-by-hour to year-by-year

TENANT BILLING SOFTWARE


MEASURE. MONITOR. MANAGE. BILL.
Generate billing based on actual tenant consumption. BillSuite is a PC based software program that provides individual
tenant billing capabilities to ensure accurate and complete recovery of tenant energy costs. This software solution
automates the tenant billing process by eliminating manual meter readings for simplified, more accurate measure­ment and

VerifEye™ Submetering Solutions


verification. BillSuite collects energy consumption data from all meters on a periodic basis and generates energy bills, billing
reports, energy profiles as well as graphs. Other submeters such as gas, water, BTU, etc. can be added to the tenant bill.

HOW VERIFEYE BILLSUITE TENANT BILLING SOFTWARE WORKS


SIMPLE, EFFECTIVE, TURN KEY SOLUTION TO MONITOR & BILL ENERGY USAGE

Leviton Energy BillSuite


Submeters Monitoring (Data collection, monitoring,
Hub (EMH)* billing & reporting)

• Meters record real-time kWh and kW consumption data


• Energy Monitoring Hub (EMH) receives meter data and pushes it to BillSuite
• BillSuite collects data, generates individual tenant bills using customizable utility rates, and provides graphing and
trending capabilities
• User logs into BillSuite and accesses billings and reports
*VerifEye BMO 2.0 is included at no cost with the purchase of any VerifEye Data Acquisition Hub.

www.leviton.com/les 111
VERIFEYE BILLSUITE FEATURES
• Monitor energy consumption of each tenant or whole building on a 24x7 basis
• Meters can be in a basement, wire closet or individual unit
• Billing of each tenant from the convenience of your PC
• Monthly and periodic billing reports for any or all meters
• Energy profile to identify peak demand and energy waste

BILLSUITE SOFTWARE
DESCRIPTION CAT. NO.
15 Min Interval Data
BillSuite Software 1 - 50 Meters LBSSW-01L
BillSuite Software 51 - 100 Meters LBSSW-02L
BillSuite Software 101 - 200 Meters LBSSW-03L
BillSuite Software 201 - 300 Meters LBSSW-04L
BillSuite Software 301 - 400 Meters LBSSW-05L
BillSuite Software 401 - 550 Meters LBSSW-06L
BillSuite Software 551 - 750 Meters LBSSW-07L
VerifEye™ Submetering Solutions

BillSuite Software 751 - 1000 Meters LBSSW-08L

Tenant Energy Bill

MEASUREMENT & VERIFICATION (M&V) SOFTWARE


Energy monitoring and reporting is the key to measuring and managing energy efficiency and cost.

Decision-makers everywhere are turning to VerifEye Solutions to get the information they need to make smart energy
choices. An advanced web based platform that provides real time data for your entire enterprise, VerifEye BMO 2.0 and
Energy Manager deliver the most sophisticated tools to drive energy efficiencies, reduce operating costs and create
more sustainable, environmentally sound facilities.

HOW VERIFEYE MEASUREMENT & VERIFICATION (M&V) SOFTWARE WORKS


SIMPLE, EFFECTIVE, TURN KEY SOLUTION TO MONITOR ENERGY IN REAL TIME

Leviton Energy Leviton User Interface


Submeters Monitoring Energy Manager BMO 2.0 or
Hub (EMH)* Data Center Energy Manager
Software
• Meters record real time consumption data
• Energy Monitoring Hub (EMH) receives meter data and pushes it to Energy Manager data center
• Data Center stores, manages and reports data in real time
• Energy Manager software analyzes, formats and reports the data
• User logs into Energy Manager website and accesses data and reports
*VerifEye BMO 2.0 is included at no cost with the purchase of any VerifEye Data Acquisition Hub.

112
BUILDING MANAGER ONLINE (BMO) 2.0

VerifEye™ Submetering Solutions


• Leviton hosted software application—no software installation required
• Set alarms and view graphical and historical data in intervals from one year to as little as an hour
• Provides a daily view summary of load profiles to help identify high and low consumption days and
visual daily trending patterns
• Shows the effects of energy conservation measures by tracking load profiles over a given time period
• Quickly view any building or end-user for a summary of operating parameters
• Export data to spreadsheets for analysis (.csv files)
• Plot charts to show trends and provide analytical charts with demand profiling
• Select date ranges to display information
• Copy and paste graphs into your own reports with BMO’s convenient legends

VerifEye BMO 2.0 is included at no cost with


purchase of any VerifEye Data Acquisition Hub.

www.leviton.com/les 113
ENERGY MANAGER SOFTWARE
• Simplified, easy to use with intuitive drilldown functionality
• Identify cost saving measures that can lead to greater profitability
• Discover energy inefficiencies that may be difficult to see
• Establish baselines, budgets and allocation of energy use & costs
within an enterprise
• Measure and monitor the enterprise’s carbon footprint
• Enhance LEED certification ratings with credits for measuring,
monitoring and verification
• Adopt best business practices for efficient energy use
Annual Report
• Track and trend consumption and site performance versus goals
• Highlight maintenance issues - identify sites and equipment that
need immediate attention
• Trend, compare and validate utility bills
• Provide outstanding communication and support enabling your
operations and management personnel to have the most
advanced, intuitive energy management reporting at their
fingertips in just 3 clicks!
VerifEye™ Submetering Solutions

- Real-time Report - Daily Report


- Weekly Report - Weekly Profile Report
- Monthly Report - Monthly Profile Report
- Annual Report - Comparison Report
- Carbon Emissions Report - Energy Center Report
Multiple Meter Analysis Report

ENERGY MANAGER SOFTWARE


YEAR ONE
DESCRIPTION CAT. NO.
Energy Manager Software - Base License Program -
LEMSB-000
includes (8) control points and (1) user account
Energy Manager Software - Base License Program -
includes EMH (ModBus/RS-485, Ethernet, No Modem), LEMS8-812
(8) Flex Inputs, (8) control points and (1) user account
Energy Manager Software - Specifier Version -
LEMSS-000
includes (8) control points and (1) user account
Energy Manager Software - Specifier Version -
includes EMH (ModBus/RS-485, Ethernet, No Modem), LEMS9-812 Energy Center Report
(8) Flex Inputs, (8) control points and (1) user account
Energy Manager Software - Additional User Account LEMSU-000
Energy Manager Software - Additional Points License -
LEMSP-000
includes (8) control points

ANNUAL RENEWAL
Energy Manager Software - Base License Program
Renewal – includes (8) control points and (1) user LEMSB-R00
account
Energy Manager Software – Specifier Version Renewal –
LEMSS-R00
includes (8) control points and (1) user account
Energy Manager Software – Additional User Account
LEMSU-R00
Renewal
Carbon Emissions Report
Energy Manager Software - Additional Points License
LEMSP-R00
Renewal – includes (8) control points

114
SERVICE AND SUPPORT DURING EVERY STEP OF THE PROCESS
There is much more to making lighting more energy efficient than just installing a simple device or two. System design,
product selection, installation and service: it has all got to come together. That’s where Leviton service and support
options come in. We’ll help you design your system and make the right product selections so you can create a lighting
control system that does exactly what you want it to do while saving electricity, meeting codes and standards, and even
garnering rebates.

It all starts with the Leviton sales representative. Our lighting control specialists are here to support you every step of the
way. They can perform on-site facility audits and suggest specific products and strategies for improving lighting energy
efficiency.

EXCLUSIVE WEALTH OF RESOURCES


• ASHRAE and Title 24 Apps - simplifies ASHRAE and Title 24
energy usage and lighting control requirements and provides
examples for common applications - available for Android and
Apple devices - go to www.leviton.com/apps
• ASHRAE 90.1 2010 Design Guide - Get ASHRAE information at your
finger tips—which includes real-world applications and single source
compliance strategies - go to http://ashrae.leviton.com
• California Title 24 2013 Design Guide - The basic goal of Title 24
energy standards is the reduction of energy use. Get Title 24 code
compliant solutions, information and more - go to
http://title24.leviton.com
• Dollars & Sensors® Online Energy Audit Tool - makes energy audits

Leviton Support
easier than ever - use your smart device (Android, Apple, or
Blackberry) to enter audit information and your desktop to
generate ROI reports, analyses, Bill of Materials, and a submittal
package - go to www.leviton.com/dollarsandsensors
• Occupancy sensor layout services – have a team of experts create
occupancy sensor layouts directly on your CAD drawings, complete
with a List of Equipment at no cost – go to portal.leviton.com
• LightLogger® Program – get an accurate estimate of your
energy-savings potential with this exclusive payback analysis
tool – go to www.leviton.com/logger
• ez-Learn – access education tools from the comfort of your home
or office with this exclusive 24/7 online training – go to
www.leviton.com/ezlearn
• ASAP Lighting Design software – point-and-click software allows
you to quickly and simply design, specify and enter orders – go to
www.leviton.com/asap
• Lighting control specialists at your disposal
• Field service engineers for top-level support
• Factory commissioning service
• Dedicated technical support via phone at 800 959-6004

CONTACT YOUR LOCAL LEVITON LIGHTING CONTROL


SPECIALIST TO GET YOUR FREE ENERGY AUDIT, OR
CALL 800-323-8920.

www.leviton.com/les 115
Leviton Manufacturing Co., Inc. Lighting & Energy Solutions
20497 SW Teton Avenue, Tualatin, OR 97062
tel 503-404-5500 fax 503-404-5594
tech line (6:00am–4:00pm PST Monday-Friday) 800-959-6004

Leviton Manufacturing Co., Inc. Global Headquarters


201 N. Service Rd., Melville, NY 11747-3138
tech line 1-800-824-3005 fax 1-800-832-9538

Leviton International

Middle East & Africa Canada South Korea


tel +971-4-886-4722 tel +1-514-954-1840 tel +82-2-3273-9963
fax +971-4-866-4723 fax +1-514-954-1853 fax +82-2-3273-9962
email lmeinfo@leviton.com email pcservice@leviton.com email infokorea@leviton.com

China ASEAN Countries Australia & New Zealand


tel +852-2774-9876 tel +65-9824-4468 tel +64-4-562-8327
fax +852-2774-1741 fax +65-9464-9592 fax +64-4-562-8327
email infochina@leviton.com email infoasean@leviton.com email intl@leviton.com

Latin America Europe India


tel +52-55-5082-1040 tel +47-40-60-30-30 tel +91-80-6579-1273
fax +52-55-5386-1797 fax +47-40-60-30-31 email lev_india@leviton.com
email lsamarketing@leviton.com email infoeurope@leviton.com

Visit our Website at: www.leviton.com/les

facebook.com/leviton twitter.com/leviton youtube.com/levitonmfg

G-8047D/H15-ak
REV AUG 2015

©2015 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.
‘USGBC’ and related logo is a trademark owned by the U.S. Green Building Council and is used by permission

The American Recovery And Reinvestment Act of 2009 (“ARRA”) provides federal grants and loans for projects throughout the country. Section 1605 of the Act, named the “Buy American” provision, requires
that certain materials and manufactured products used in projects funded by the Act be manufactured in the United States. The appearance of the Recovery Act Logo in relation to a Leviton product is only
intended to reflect that such product may be used in an ARRA funded project. It does not mean that such product or Leviton is sponsored or endorsed by, or that Leviton receives funds from, the federal
government or the Recovery Accountability and Transparency Board. Nothing in Leviton’s use of the logo is intended to suggest anything regarding the requirements for funding under ARRA.