Вы находитесь на странице: 1из 1

Image not found Image not found

https://www.laboratory-equipment.com/templates/cart/images/terra-universal-logo.png https://www.laboratory-equipment.com/templates/cart/images
714-578-6000
M-F, 5:30am - 5:30pm, L.A. Time

Lambda 365 UV/Vis Spectrophotometer with UV Lab Software

Price: $11,224.00 EA
Part #: 5102-30

Usually ships in 10-20 days

Manufacturer: Perkin Elmer Health Sciences

U.S. orders include packaging.

Product URL: https://www.terrauniversal.com/product/5102-30

Designed for high-performance and versatility


Dual beam optics for high stability and low stray light
<span>• Requires connection to PC for operation
• Includes: UV Express Software #N4108000 auto aligns optional multi-cell changers
• Dimensions: 19.5 x 19.7 x 10.6in (495 x 500 x 270 mm)
• Electrical: 100―240 V 50/60 Hz
• Source Lamp: Tungsten/Deuterium
• Monochromator Blazed holographic grating with 1200 gr/mm, Czerny― Turner with 0.2 m focal
length
• Detector: Si diodes, Sample and Reference
• Photometric System: Double Beam Optics
• Wavelength Range: 190―1100 nm
• Spectral Bandwidth: 0.5, , 1, 2, 5, 20 nm
• Data Interval: 0.05, 0.1, 0.5, 1, 2 nm
• Wavelength Accuracy: ±0.1 nm at D2 peak @ 656.1 nm, +/― 0.3 nm for full range
• Wavelength Reproducibility: ±0.1 nm
• Photometric Range: +/― 4 A
• Photometric Accuracy: +/― 0.002A (0―.5 Abs), +/― 0.004A (.5―1 Abs)
• Photometric Reproducibility: &lt;0.001AU @ 0.5 and 1.0 AU, &lt;0.002AU(60 mg/L Potassium
Dichromate)
• Stray Light: &lt; 1.0% ( 198 nm KCL )</span>;<span> &lt;0.02% (220 nm Nal)</span>;<span> &lt;0.02% (340 nm NaNO2 )
• Photometric Noise: &lt; 0.00005 Abs (at 700 nm, RMS )
• Interface: USB</span>
• Compact and modular UV/Vis Spectrophotometer
• Double beam optics for high stability and low stray light
• Extremely high signal to noise ratio
• Modular design and a large number of accessories provides for maximum usability
• Large sample compartment fits more than 10 sampling accessory combinations
• Ideal for use in biotechnology, environmental, genetics, manufacturing, pharmaceutical QA/QC and
academic labs
• Use in: applications requiring regulatory compliance, kinetic measurements, determination of
nucleic acid concentration, determining the thickness and reflectance/transmission of films
• Accessories sold separately: Transmission and Reflectance Holders, Variable and Fixed Angle
Reflectance Accessories and Base Plates, Peltier Controlled Systems, Lambda 365 Software

Electrical: 120/240 V V, A, W, P, Hz
Package Type: Box