Вы находитесь на странице: 1из 2

ERROR CODES LIST for the BMS2 system (VC and PWM versions)

EXTERNAL ERROR CODES:

CODE FAULT POSSIBLE CAUSES TYPE POSSIBLE VERIFICATIONS


E00 Joystick 1 (AK1) working with safety contact open. DK3 not properly connected, joystick faulty or deadband too low. VC/PWM Follow these steps:
E01 Joystick 2 (AK2) working with safety contact open. DK4 not properly connected, joystick faulty or deadband too low. VC/PWM 1. Check the wirings under the joysticks for any possible electric false connection on wires and
E02 Joystick 3 (AK3) working with safety contact open. DK5 not properly connected, joystick faulty or deadband too low. VC/PWM connectors.
E03 Joystick 4 (AK4) working with safety contact open. DK6 not properly connected, joystick faulty or deadband too low. VC/PWM 2. Replace the faulty joystick corresponding to the error code shown.
E04 Joystick 5 (AK5) working with safety contact open. DK7 not properly connected, joystick faulty or deadband too low. VC/PWM 3. Call the Hetronic service, so that the deadband software parameter can be checked.
E05 Joystick 6 (AK6) working with safety contact open. DK8 not properly connected, joystick faulty or deadband too low. VC/PWM
E06 Joystick 7 (AK7) working with safety contact open. DK9 not properly connected, joystick faulty or deadband too low. VC/PWM
E07 Joystick 8 (AK8) working with safety contact open. DK10 not properly connected, joystick faulty or deadband too low. VC/PWM
Check if there are no shortcuts on the loads; the cable has not been damaged and the maximum
E08 Over current in the circuit of E-STOP. The maximum supplying current of the radio remote control (9A) has been exceeded. supplied current to the loads doesn't exceed 9A. If the error code appears when you turn on the
VC/PWM system, call the Hetronic service.

E09 Overcurrent on a ON/OFF output (from OUT 1 to OUT 5 or Y0) Shortcut on an ON/OFF load or the ON/OFF output broken. VC/PWM Check the ON/OFF loads. Verify the cable has not been damaged. If necessary, contact the Hetronic
E10 Overcurrent on a ON/OFF output (from OUT 6 to OUT 11). Shortcut on an ON/OFF load or the ON/OFF output broken. VC/PWM service to check the radio remote control.
Check the power supply voltage of the radio remote control. If necessary, contact the Hetronic service
E11 Over voltage on the power supply. V_in > 35V (power supply voltage higher than 35 Volt)
VC/PWM to check the radio remote control.
Check the power supply voltage of the radio remote control. Verify the section of the electrical cable
E12 Under voltage on the power supply. V_in < 8V (Power supply voltage lower than 8 Volt) for the power supply: it has to be proportional to the load and to the length. If necessary, contact the
VC/PWM Hetronic service to check the radio remote control.
E13 Voltage read back error on the Y0 output (safety valve). Safety valve broken, Y0 radio output broken or faults on the cable. VC/PWM Check if there is water in side the receiver box. Verify that there are no shortcuts on the ON/OFF loads
and that the cable has not been damaged. If necessary, contact the Hetronic service to check up the
E14 Voltage read back error on the OUT1 output (start radio). Shortcut on an ON/OFF output, OUT1 of the radio broken or faults on the cable. VC/PWM radio remote control.
E15 Read back error for power supply voltage of valve 1. Radio remote control power output 1 faulty or electrovalve faulty. VC
E16 Read back error for power supply voltage of valve 2. Radio remote control power output 2 faulty or electrovalve faulty. VC
E17 Read back error for power supply voltage of valve 3. Radio remote control power output 3 faulty or electrovalve faulty. VC
E18 Read back error for power supply voltage of valve 4. Radio remote control power output 4 faulty or electrovalve faulty. VC
E19 Read back error for power supply voltage of valve 5. Radio remote control power output 5 faulty or electrovalve faulty. VC
E20 Read back error for power supply voltage of valve 6. Radio remote control power output 6 faulty or electrovalve faulty. VC
E21 Read back error for power supply voltage of valve 7. Radio remote control power output 7 faulty or electrovalve faulty. VC 1. Check the output cable, probably it's faulty or there are shortcuts on it;
E22 Read back error for power supply voltage of valve 8. Radio remote control power output 8 faulty or electrovalve faulty. VC 2. Check the electrovalves are working correctly;
E23 Read back error for proportional control voltage of valve 1. Radio remote control proportional output 1 faulty or electrovalve faulty. VC 3. Try to exchange the plugs on the distributor. If the problem is due to the hydraulic control block the
E24 Read back error for proportional control voltage of valve 2. Radio remote control proportional output 2 faulty or electrovalve faulty. VC errorcode will be changed. Otherwise the problem regards the radio or its cable.
E25 Read back error for proportional control voltage of valve 3. Radio remote control proportional output 3 faulty or electrovalve faulty. VC
E26 Read back error for proportional control voltage of valve 4. Radio remote control proportional output 4 faulty or electrovalve faulty. VC
E27 Read back error for proportional control voltage of valve 5. Radio remote control proportional output 5 faulty or electrovalve faulty. VC
E28 Read back error for proportional control voltage of valve 6. Radio remote control proportional output 6 faulty or electrovalve faulty. VC
E29 Read back error for proportional control voltage of valve 7. Radio remote control proportional output 7 faulty or electrovalve faulty. VC
E30 Read back error for proportional control voltage of valve 8. Radio remote control proportional output 8 faulty or electrovalve faulty. VC
There is a shortcut on a proportional valve. Move one by one the valves so that you can localize which
E31 Shortcut detected on a proportional PWM valve. A proportional valve is faulty or the shortcut threshold (software parameter) is too low. PWM one is faulty. If necessary, call the Hetronic service, so that the shortcut threshold can be
verified.

Hetronic South Europe Page 1 of 2 21/05/2009


ERROR CODES LIST for the BMS2 system (VC and PWM versions)

E32 Error signal received from valve n° 1 (Sauer-Danfoss). Error state for valve n° 1. VC
E33 Error signal received from valve n° 2 (Sauer-Danfoss). Error state for valve n° 2. VC
E34 Error signal received from valve n° 3 (Sauer-Danfoss). Error state for valve n° 3. VC
E35 Error signal received from valve n° 4 (Sauer-Danfoss). Error state for valve n° 4. VC The hydraulic oil distributor (Sauer-Danfoss) has sent an error message to the
E36 Error signal received from valve n° 5 (Sauer-Danfoss). Error state for valve n° 5. VC radio remote control: verify the hydraulic control block.
E37 Error signal received from valve n° 6 (Sauer-Danfoss). Error state for valve n° 6. VC
E38 Error signal received from valve n° 7 (Sauer-Danfoss). Error state for valve n° 7. VC
E39 Error signal received from valve n° 8 (Sauer-Danfoss). Error state for valve n° 8. VC
Check the CAN-BUS wiring is properly connected (CAN-L and CAN-H cannot be inverted). If
E40 Communication Error (TIME-OUT) on the CAN-BUS. CAN-BUS is not properly connected or signal missing. VC/PWM
necessary, contact the Hetronic service to check up the radio remote control.
E41 START attempt without OK signal from TP7. TP7 not correctly used. VC/PWM Before pressing START on the radio control verify the enabling - signal from the machine.

E42 START attempt with a toggle-swich (or joystick) on. It's not possible to start the system: a toggle-switch or a joystick is on. VC/PWM Before pressing START on the transmitter, check all the toggle-switches and joysticks: they all have to
be off. If necessary, contact the Hetronic service to check up the radio remote control.

INTERNAL ERROR CODES:

CODE MEANING POSSIBLE CAUSES TYPE POSSIBLE VERIFICATIONS


E50 CPU test failed. Main base board faulty. VC/PWM
E51 WATCHDOG test failed. Main base board faulty. VC/PWM
E52 INTERRUPT test failed. Main base board faulty. VC/PWM
E53 TIMER test failed. Main base board faulty. VC/PWM
E54 EXTERNAL RAM test failed. Main base board faulty. VC/PWM
E55 INTERNAL RAM test failed. Main base board faulty. VC/PWM
E56 INTERNAL PRAM test failed. Main base board faulty. VC/PWM Call the Hetronic service to check up the radio remote control.
E57 FLASH memory test failed. Main base board faulty. VC/PWM
E58 STACK OVERFLOW detected. Software fault. VC/PWM
E59 Main loop time failed. Software fault. VC/PWM
E60 OP counter error. Software fault. VC/PWM
E61 Serial EEPROM checksum error. EEPROMs not programmed or faulty. VC/PWM
E62 HW internal error. Main base board faulty. VC/PWM

DURING THE TRUCK WASHING DO NOT THROW WATER-JETS AGAINST THE RECEIVER BOX OR ITS CONNECTORS.

NOTE: For error codes higher or equal than E50, you need to reboot the receiver to reset the system.

LIST OF STATUS CODES FOR THE RADIO REMOTE CONTROL BMS2 (VC/PWM)
004 RX power supply is OK, but the TX radio signal is missing (TX off, wrong radio channel or invalid transmitter).
xx3 The radio signal is too low (the system will keep to work for two seconds more: it's just a warning message)
002 Emergengy push button (E-STOP) on the TX is pressed.
xx1 RX power supply and radio signal are good, but the system has not been armed yet by pressing the START switch.
xx0 The system has been armed and every function is ready to be used.

NOTES:
1. "x" represents any number. In normal conditions the RX status is completely shown by the last number on the display.
2. In normal conditions, the first number shows which joystick (AK) is used.
3. A blinking dot after the third digit shows that the radio signal is good (each flash is a valid telegramm received from the TX).
4. A blinking dot after the second digit shows that the red key is in PROGRAMM mode (in this case you can change the prop. min and max values)
00.0
Hetronic South Europe Page 2 of 2 21/05/2009