Вы находитесь на странице: 1из 3

GSM Energy Saving Solution

Features for Energy Saving

Cell level
TRX Power Amplifier
Intelligent Shutdown
Dynamic Cell Power Off
TRX level Enhanced BCCH Power
Consumption Optimization
TRX Power Amplifier Intelligent
Shutdown on Timeslot Level
TRX Working Voltage Adjustment Site level
Multi-Carrier Intelligent Voltage PSU Smart
Regulation Control
Power Optimization Based
on Channel Type

Feature Overview

TRX Power Amplifier Intelligent Shutdown


Switch off no-traffic TRXs of idle cells when traffic requirements are met.

TR1 TR3 TR1

TR2

TR1 TR2 TR3 Energy saving TR1 TR2 TR3

Power-on Power-off
PSU Smart Control
Disable redundant PSUs based on required BTS power consumption needs.
Benefits: Improves power system efficiency and extends the system life cycle.
High traffic: All PSUs are enabled. Low traffic: Some PSUs are disabled.

Cabinet Cabinet

PSU PSU
ON ON ON ON OFF OFF

Enhanced BCCH Power Consumption Optimization


Reduces the transmit power of non-BCCH timeslots on the BCCH TRX.

Without this feature With this feature

W W
3 dB max
60 60 Reduced transmit power
TS0 TS1 TS2 TS3 TS4 TS5 TS6 TS7 TS0 TS2
30 30 TS3 TS4 TS5 TS6 TS7
TS1
0 T 0 T

BCCH,TS0, 60 W TS1,60 W TS2,60 W BCCH,TS0, 60 W TS1,30 W TS2,50 W

Full-power transmission on all BCCH Reduced transmit power non-BCCH


timeslots at any time timeslots

Multi-Carrier Intelligent Voltage Regulation


Dynamically adjusts the PA voltage based on output powerneeds of the multi-transceiver module.
Benefits: Improves PA working efficiency and reduces BTS power consumption.
Before
30 Fixed PA voltage
Avg Power(W) / sector

25

20 After
Adjustable
15
PA voltage
10

0 Time
10:00-11:00

12:00-13:00

14:00-15:00

16:00-17:00

18:00-19:00

20:00-21:00

22:00-23:00
0:00-1:00

2:00-3:00

4:00-5:00

6:00-7:00

8:00-9:00
Dynamic Cell Power Off
In a specified period, if the traffic in a 900 MHz cell is low and can carry the traffic in a 1800 MHz
cell as well, the 1800 MHz cell is powered off.
Traditional dual-band cell Intelligent shutdown of dual-band cell

Power-off
1800 MHz
900M 1800 MHz

900 MHz 900 MHz

Cells on both frequency bands If the traffic is low, a 900 MHz cell with a
are always working. broad coverage remains working, and a
1800 MHz cell is powered off.

Visualized Monitoring
View power consumption in real time based on generated graphs, improving O&M efficiency.

Visualized
monitoring

Statistics and analysis

EMS

Glossary: PA Power Amplifier TS Time Slot PSU Power Supply Unit EMS Element Management System

Wireless Network
Information Center Tech Support

Documentation Dept, WN
Copyright © Huawei Technologies Co., Ltd. 2018. All rights reserved.