Вы находитесь на странице: 1из 1

FLOOR DECK

FD938 Limit States


Design

Metric

Base Steel Nominal Moment of Factored Resistance


Mass with Section Modulus
PHYSICAL Nominal Thickness Inertia Moment Reaction
Coating
PROPERTIES Thickness Z275 Coating Midspan Support Midspan Midspan Support Ext. Int.
(mm) (mm) (kg/m2) 3
x 10 (mm )
3 3
x 10 (mm )
3 3
x 10 (mm )
4
(Nm) (Nm) (kN) (kN) Notes
1 Properties and
(PER METRE WIDTH) 0.76 0.80 8.60 9.59 9.76 213.9 1985.1 2020.3 10.9 15.7
loads are based on
In accordance with CSA
0.91 0.95 10.17 11.70 12.31 266.8 2421.9 2548.2 15.3 22.3 Grade 230 Steel
Specification S136-01
with a minimum
1.22 1.26 13.34 15.87 16.21 363.9 3285.1 3355.5 25.8 38.4 yield stress of 230
1.52 1.56 16.45 20.00 20.06 454.3 4140.0 4152.4 38.9 58.7 MPa, and a
maximum stress
0.00 0.00 0.00 0.00 0.00 0.0 0.0 0.0 0.0 0.0 under Factored
loads of 207 MPa.
0.00 0.00 0.00 0.00 0.00 0.0 0.0 0.0 0.0 0.0

LOAD Support 1-Span 2-Span 3-Span 2 Row B indicates


Spacing the load capacity
TABLE (mm) 0.76 0.91 1.22 1.52 0.00 0.00 0.76 0.91 1.22 1.52 0.00 0.00 0.76 0.91 1.22 1.52 0.00 0.00 based on strength.
Maximum Specified Strength capacity
B 13.1 15.9 21.6 27.3 9.3 13.2 22.1 27.3 10.6 15.0 25.9 34.2
Uniformly Distributed 900 should be checked
Load in kN/m2 (kPa) D 12.7 15.8 21.6 27.0 31.8 39.7 54.1 67.6 24.0 29.9 40.8 50.9 against [Specified
Live Load] +[0.833
B 9.6 11.7 15.9 20.0 8.0 11.3 16.2 20.1 9.1 12.9 20.3 25.1 x Specified Dead
1050
D Load]
8.0 10.0 13.6 17.0 20.0 25.0 34.1 42.6 15.1 18.8 25.7 32.1
B 3 Row D indicates
7.4 9.0 12.2 15.3 7.0 9.4 12.4 15.4 7.9 11.3 15.5 19.2
1200 the load capacity
D 54
5.4 6.7
67 9.1
91 11.4
11 4 13.4
13 4 16.7
16 7 22.8
22 8 28.5
28 5 10.1
10 1 12.6
12 6 17.2
17 2 21.5
21 5 based on a
deflection of
B 5.8 7.1 9.6 12.1 5.9 7.5 9.8 12.2 7.0 9.3 12.3 15.2
1350 1/360th span. For
D 3.8 4.7 6.4 8.0 9.4 11.8 16.0 20.0 7.1 8.9 12.1 15.1 allowable deflection
of 1/180th span,
B 4.7 5.7 7.8 9.8 4.8 6.0 8.0 9.8 6.0 7.6 9.9 12.3 values in Row D
1500
D can be doubled,
2.7 3.4 4.7 5.8 6.9 8.6 11.7 14.6 5.2 6.5 8.8 11.0
but must not
B 3.9 4.7 6.4 8.1 4.0 5.0 6.6 8.1 4.9 6.2 8.2 10.2 exceed the value in
1650
D Row B.
2.1 2.6 3.5 4.4 5.2 6.4 8.8 11.0 3.9 4.9 6.6 8.3
B 3.3 4.0 5.4 6.8 3.3 4.2 5.5 6.8 4.2 5.2 6.9 8.5 4 A highlighted value
1800
D indicates capacity
1.6 2.0 2.7 3.4 4.0 5.0 6.8 8.4 3.0 3.7 5.1 6.4
has been reduced
B 2.8 3.4 4.6 5.8 2.8 3.6 4.7 5.8 3.5 4.5 5.9 7.3 to account for web
1950 crippling.
D 1.2 1.6 2.1 2.7 3.1 3.9 5.3 6.6 2.4 2.9 4.0 5.0
B 2.4 2.9 4.0 5.0 2.4 3.1 4.1 5.0 3.1 3.9 5.1 6.3
2100
D 1.0 1.2 1.7 2.1 2.5 3.1 4.3 5.3 1.9 2.4 3.2 4.0
B 2.1 2.6 3.5 4.4 2.1 2.7 3.5 4.4 2.7 3.4 4.4 5.5
2250
D 0.8 1.0 1.4 1.7 2.0 2.5 3.5 4.3 1.5 1.9 2.6 3.3
B 1.8 2.2 3.0 3.8 1.9 2.4 3.1 3.8 2.3 2.9 3.9 4.8
2400
D 0.7 0.8 1.1 1.4 1.7 2.1 2.9 3.6 1.3 1.6 2.2 2.7
B 1.6 2.0 2.7 3.4 1.7 2.1 2.8 3.4 2.1 2.6 3.4 4.3
2550
D 0.6 0.7 1.0 1.2 1.4 1.7 2.4 3.0 1.1 1.3 1.8 2.2
B 1.5 1.8 2.4 3.0 1.5 1.9 2.5 3.0 1.8 2.3 3.1 3.8
2700
D 0.5 0.6 0.8 1.0 1.2 1.5 2.0 2.5 0.9 1.1 1.5 1.9
B 1.3 1.6 2.2 2.7 1.3 1.7 2.2 2.7 1.7 2.1 2.8 3.4
2850
D 0.4 0.5 0.7 0.8 1.0 1.2 1.7 2.1 0.8 0.9 1.3 1.6
B 1.2 1.4 1.9 2.5 1.2 1.5 2.0 2.5 1.5 1.9 2.5 3.1
3000
D 0.3 0.4 0.6 0.7 0.9 1.1 1.5 1.8 0.6 0.8 1.1 1.4

1. Deflection values are based upon service loads.


2. Denotes web crippling governs.

© Copyright VICWEST R-4/01