Вы находитесь на странице: 1из 8

STATIC FORCE PROCEDURE

A. Base Shear
𝐶𝑣 𝐼
𝑉= 𝑊
𝑅𝑇

2.5𝐶𝑎 𝐼
𝑉𝑚𝑎𝑥 = 𝑊
𝑅

Lower limits for V:


𝑉 = 0.11 𝐶𝑎 𝐼 𝑊 (for all structures)

0.8 𝑍𝑁𝑣 𝐼
𝑉= 𝑊 (additional limit for Seismic Zone 4)
𝑅
where: Seismic Zone Factor Z (see Table 208-
Ca : acceleration-controlled coefficient 3 & Table 208-4)
(see Table 208-7) Near-Source Factors Na and Nv (see Table
Cv : velocity-controlled coefficient 208-4 and Table 208-5)
(see Table 208-8) Soil Profile Type (see Table 208-2)
I: Importance Factor (see Table 208-1) Seismic Source Type (see Table 208-6)
W : Total Seismic Dead Load
R : numerical coefficient representative of
the inherent overstrength and global
ductility capacity of lateral-force resisting
systems (see Table 208-11)
T : elastic fundamental period of the
structure in the direction under
consideration
T : STRUCTURAL PERIOD

𝑇 = 𝐶𝑡 ℎ𝑛 3 4

Ct = 0.0853 for steel moment resisting frame


Ct = 0.0731 for RC moment resisting frame and
eccentrically braced frame
Ct = 0.0488 for all other structures
LATERAL DISTRIBUTION OF LOADS
Ft = 0.07TV

𝐹𝑡 ≤ 0.25𝑉

𝑇 ≤ 0.7𝑠, 𝐹𝑡 = 0
Using the NSCP 2015 provisions for seismic lateral
forces, determine the following
A. Design base shear
B. Distributed Lateral forces
C. Shear and Moment on each floor of the five
storey office building
D. Shear, axial and moment of the beams and
columns using portal method
If 3 members, analyze Frame B only.
If 4 or more members, analyze Frame B and 2.
DATA:
Occupancy: Office
Location: Baguio City
Structural System : Concrete SMRF

LOADS:
Interior Partitions – 1000 Pa
Toppings and finishes – 1000 Pa
Toppings and water proofing – 1750 Pa
Ceiling, Electrical & Plumbing fixtures – 750 Pa
150mm CHB exterior Walls – 2000 Pa

Assumed Dimensions:
Roof Deck Slab – 125 mm thick
Slab – 100 mm thick for all floors
Parapet Wall – 100 mm thick concrete
BEAMS (Reinforced Concrete) Columns (Reinforced Concrete)
• Level 5 – 250mm x 250mm
• Roof Deck - 200mm x 350mm
• Parapet – 200mm x 350mm • Level 4 – 300mm x 300mm
• Level 5 – 200mm x 350mm • Level 3 – 300mm x 300 mm
• Level 4 – 250 mm x 350mm • Level 2 – 350mm x 350mm
• Level 3 – 250 mm x 350mm
• Ground – 400mm x 400mm
• Level 2 – 300mm x 350mm

Assume unit weight of concrete to be


equal to 24kN/m^3
Dimension “s” is the average of all the
members’ last number in the student
number.

Вам также может понравиться