Академический Документы
Профессиональный Документы
Культура Документы
UPS SYSTEM
SOLAR
STREET LIGHTS WINDMILL
UPS
DUBAI
BATTERY
UPS FOR
SIN GAPORE HOSPITALS
STABILIZERS
MRI MATE
UPS SYSTEM
SAL E S/ SER V I C E
UPS FOR
H E AD O F F I C E SCHOOLS
S RILAN KA LIFT ON
UPS FOR LIFTS
AFRICA
Unit 2 : no.23, 1 st floor, 2nd cross, Nanda Unit 3 : no.23, 4 th floor, 2 nd cross, Nanda
Gokula Industrial area, Tigalarpalya, near Gokula Industrial area, Tigalarpalya, near
peenya 2 nd stage, bangalore-560058 peenya 2 nd stage, bangalore-560058
Statutory Notice:
All batteries contain lead, which is harmful for humans & environment. As per This catalogue is issued to provide outline information only & is not deemed to
statutory requirements, the used battery must be returned to the authorized form part of an offer or contract. Our policy is one of continued improvements &
dealer, manufacturer or at the designated collection centers. we reserve the right to change details without prior notice
Solutions for every industry
Alpha Power Solutions
Alpha Power Solutions. India's most admired power solutions provider, with a
growing presence across India and throughout Karnataka. A truly knowledge
driven company, with innovation at its heart, Alpha develops intelligent
CNC MACHINES ATM MACHINES SOLAR UPS CALL CENTERS
power back-up solutions, engineered to be energy efficient and thus reduce
the users carbon footprint. Working further towards a cleaner, greener planet,
we are branching out towards eco friendly inexhaustible energy solutions like
solar power. We see ourselves as change agents in the critically important
sphere of energy, working for a better tomorrow. With the vision spreading the
PETROL PUMPS SEWING MACHINES MRI MACHINES IT COMPANIES greener energy faster, we also take care of bulk manufacturing and white
collared production.
Overview
Founded in 2002 1000 plus
DENTAL CHAIR &
COMPRESSORS
power product range
AC DC PUMPS DATA CENTERS HOSPITALS
Altitude: 0 – 2000m | Temperature: 0 – 40 C | Humidity: 95% Non Condensing | Noise: <60dB Type External Tubular / Valve Regulated Lead - Acid
Features
Standard Confirms to latest IS-9815 & ISO 2026 standards Standard Overload Reset & Front Panel LCD Panel
Rating Upto 5000 kVA Optional Spike & Surge Suppressor, Inverter Bypass &
Software Control / Communication/SNMP
Input Voltage Ranges Single Phase :160V-260V, 140V-280V and 90V-270V (Can be customised)
Three Phase : 270V - 460V, 250V-460V and 150V-460V (Can be customised) Protection
Output Voltage Ranges Single Phase : 220/230/240 ± 1% & Three Phase : 380/400/415 ± 1% Charger Type current Voltage & Current Limiter, Phase Sequence & Failure
Protector & Fuse/ Circuit Breaker with IGBT /SCR Rectifier.
Output Perform 110V output for imported equipments
Input Frequency 47 - 53 Hz Inverter Over Voltage & Over Current Cut-off, Overload cut-off &
Short Circuit Protection
Response Time Instantaneous (milisec)
Battery Battery Deep Discharge & Overcharge Cut-off & HRC
Correction Speed 10 - 60Visec (as required) Fuse / Circuit Breaker
Indication
Correction Methods Step less correction using SerYokon's make varibc
Cooling Natural Air / Natural Oil Visual Mains, Charger, Inverter, Battery & Error Information
Status
Efficiency More than 98% Audible Changeover, Overload, Battery low & other Error Alerts
Duty Cycle Continuous 24 Hrs.
Environment
Operation Auto/Manual
Altitude 0 – 2000m
No Load Loss Less than 0.4%
Compatibility Test Specially designed control card for faithful operation on Mains as well as DG Set Temperature 0 – 40 C
Suitability Suitable for 100% Unbalanced/Balanced Supply & 100% Unbalanced/Balanced Loads Humidity 95% Non Condensing
Operating Temperature -15°C to 50°C above ambient Noise <60dB
3 www.alphapowersolutions.in www.alphapowersolutions.in 4
ONLINE SPECIFICATION SOLAR PCU
40-200KVA(3:3) MODEL-SHI 101/SGI 101/SGI 303
Capacity 40 KVA - 200KVA Technology MPPT technology
Inverter Over Voltage & Current Cut-off, Overload cut-off & Efficiency
Short Circuit Protection
Battery Battery Deep Discharge & Overcharge Cut-off & HRC Efficiency@100% Load On Inverter Mode > 85% > 85-90% > 85-92%
Fuse / Circuit Breaker On Mains Mode 98% 98% 98%
Indication
Multifunctional Solar LCD Energy Meter
Visual Mains, Charger, Inverter, Battery & Error Information
Status Indicates Following Solar Voltage Solar Current Solar Power Solar Energy Generated Input Voltage
Audible Changeover, Overload, Battery low & other Error Alerts Parameters Output Voltage Battery Voltage Load Current
Enclosure Protection
Environment
Temperature 0 – 40 C Environmental
Humidity 95% Non Condensing Acoustic Noise Level < 60db@1.5 meter
Operating Ambient Temperature 0 to 40 deg C
Noise <60dB
Utility Power Input
5 www.alphapowersolutions.in www.alphapowersolutions.in 6
UPS SYSTEMS UPS SYSTEMS FOR UPS SYSTEMS
FOR LIFTS PETROL PUMPS FOR GYM
SOLAR UPS SPECIFICATION
Capacity 5KVA to 40 KVA 4 -10 KVA 4 -10 KVA
Static Voltage Regulation +/-1% of Nominal for all Variations of Line Load & +/-10% for 10-100% step Load Change
Total Harmonic Distortion Linear Load <_2.5% & Non-Linear Load >_5%
Over Load 125% for 10minutes & 150% for 1 Minute
Crest Factor 1:3
Battery
Features
Environment
7 www.alphapowersolutions.in www.alphapowersolutions.in 8
SOLAR UPS SPECIFICATION
RATING 5KVA To 10KVA / 10KVA To 50KVA *High speed pulse by pulse electronic
DC BUS 72 V To 192 VDC / 192 V To 360V *Linear current limiting, under voltage trip
Input Voltage Window 180V-250V / 330V-470V *Battery deep discharge, mains high & low cut
*Solar voltage
Maximum Open Circuit Array Voltage *Energy generated(energy generated and delivered to load
OUTPUT ALARMS
Waveform On Inverter Mode Pure Sine wave Cable Entry Rear Side
Mode Of Operation Designed For Continuous Operation Ambient Temperature 0 to 450 Deg C
Inverter Protection Advanced Electronic Protection for device safety backed up with Storage Temperature -10 to 70 Deg C
MCB’s& fast acting fuses, high speed pulse by pulse electronic device
protection over voltage/ under voltage protection, Electronic over current Humidity Up to 95% RH Non condensing
trip. Altitude <3000 Feet above sea level( without de rating )
Efficiency On Inverter Mode >84% on full load
Extreme climatic conditions AC Environment is required if the temperature goes beyond the normal
On Mains Mode >98% operating temperature (0-45deg C)
LED Indication(5 LED With Multi Function) Battery Type SMF/Tubular , If Smf AC must be require
9 www.alphapowersolutions.in www.alphapowersolutions.in 10
Unmatched Technical Parameters of PRO C10 Tubular Batteries
Performance
TYPE No of 10 Hour L W H Start Finish Electrolyte
Plate Rate capacity Volume(Kgs)
PRO 150 TT 3+4 15 Hrs 520mm 190mm 460mm 15 7.5 23.8 Solar
Why Alpha
is the best battery
Low Maintenance among others?
The combination of low antimony alloy
SOLAR UPS / INVERTER WINDMILL MACHINES & ceramic vent plug keeps the water
Addition requirement very low, A Topping 99.991% Pure Primary Lead
Up frequency of once in 4-6 months can (for better performance)
Easily be achieved in normal operating conditions
Alpha imports best quality primary lead of purity
99.991% from Australia This ensures longer battery life.
Heat Sealed Tubular Battery: Benefits
- Longer Life – Low Life cycle cost - Ideal for cycle and float applications
- Trouble free Performance – Higher reliability - High power at different rates of discharge Suggestion Initial Charging Instructions
For constant potential charging higher rates are permissible for Fill up to the required level with bbattery grade dilute sulphuric acid
- Low Maintenance cost - Safe to use, Suitable for deep discharge application maximum charger setting of 2.40 volts per cell.
Filling specific gravity: 1.220+_ 0.005 at 27 c
Trickle charge voltage should be adjusted to 2.25 volts per cell.
- Low self discharge - Tolerant to high temperature applications Rest period: 12 hours
Technical information regarding 12V Pro Tubular available on request. Charge at 12% of C(10) capacity to 2.35 vpc & then at 6% of C(10) capacity to
2.75vpc Minimum Ah input: 450% of C10 capacity
All parameters for 12Volts Nominal Monobloc Units
11 www.alphapowersolutions.in www.alphapowersolutions.in 12
Add-on Products
Static Bypass switch itself. The photovoltaic panels charge a rechargeable battery, which powers a fluorescent
The UPS could be a double conversion or a delta conversion or rotary type. The static or LED lamp during the night.
bypass switch provides a means to accomplish high-speed transfer to the bypass
path in case of UPS failures. Also, the static bypass switch is used to bypass the UPS Alpha Solar street lights are independent of the utility grid. Hence, the operation costs
so that maintenance can be performed on the UPS. Because electromechanical are minimized.
contactors and circuit breakers are not fast enough to accomplish such high-speed Alpha Solar street lights require much less maintenance compared to conventional street
transitions, a power disruption could occur. A static bypass switch is employed to lights.
provide uninterrupted power to the load during normal-to bypass and
bypass-to-normal transitions. Since external wires are eliminated, risk of accidents are minimized.[2]
This is a non polluting source of electricity
SNMP Separate parts of solar system can be easily carried to the remote areas
Alpha SNMP cards are an interface between the UPS and the network. Cards can
It allows the saving of energy and also cost.
communicate the status of a UPS and issue
commands to it. All Minuteman SNMP cards support SNMP and HTTP protocols for
user access.
Through the SNMP NMS and/or Web Browser, users can monitor the UPS status, Battery chargers
issue commands, and set up the SNMP card through the network We are a prominent organization, which is engaged in offering Industrial Battery Chargers. The
offered range of Industrial Battery Chargers is known for operating under voltage deviations. These
chargers are portable in nature. These Industrial Battery Chargers are appreciated for their high
SNMP Card Features tolerance to extremities. In addition to this, the offered range is acclaimed for its compact size
Connect the UPS directly to a LAN - utilizing a standard RJ45 Ethernet connection; lending portability.
requires no special application software
Network UPS management - monitor and manage the UPS over any computer Features:
attached to the network Five stage charging
Integrate UPS into Network Management System (NMS) – using the inlcluded Wide input supply range
MIB (Management Information Base) agent or the included SNMP management 100% full load burn-in test
software LED indication for float, boost, and battery rev. polarity, Mains ON
Schedule events – shutdown or restart connected equipment daily, weekly, or Automatic selection of FLOAT and BOOST mode
monthly using the integrated scheduler Protections Short circuit/overload/over voltage/battery reverse polarity protection
Track utility problems via Event Logs – to provide history of power events on the Solar Charge controller
UPS including: power quality, equipment draw, and blackouts. A solar Charge controller, is a type of electrical converter which converts the variable direct
Multiple server shutdown - using the included SNMP management software allows current (DC) output of a photovoltaic (PV) solar panel into a utility frequency alternating current (AC)
the UPS to shutdown multiple devices sequentially when a power event occurs that can be fed into a commercial electrical grid or used by a local, off-grid electrical network. It is a
critical balance of system (BOS)–component in a photovoltaic system, allowing the use of ordinary
Event Notification – notify multiple IT personnel via SNMP traps or e-mail when a AC-powered equipment. Solar power inverter shave special functions adapted for use with
power event occurs photovoltaic arrays, including maximum power point tracking and anti-islanding protection.