Вы находитесь на странице: 1из 1

BPA Ltd. - Column Design Program, Version 0.

001, 2011 April 17


Design of a Rectangular Reinforced Concrete Column in accordance with CSA CAN3-A23.3-04
Job Code: Demo Example, User: Student
Description: Assignment Section 8

Column Depth : 600 mm, Column Width: 350 mm, Cover to Ties: 40 mm
Column Length: 3.000 m, Effective Length Factor 1.00
Moment Ratio : 1 , klu/r : 17, Pc: 52434 kN, Pfs: 6300 kN,
Concrete fc': 40.0 MPa, alpha1: 0.790, beta1: 0.870,
Rebar fy: 400.0 MPa,
All Edges , Steel , Prmax , Tie Spacing , Pcrit ,Max Mag.,
7 Layouts , Ratio , kN , Size at mm , kN , Factor ,
8 x 20M , 1.14% , 4104, 10M at 312, 41244, 1.15,
4 x 30M , 1.33% , 4212, 10M at 350, 48586, 1.13,
12 x 20M , 1.71% , 4430, 10M at 312, 47366, 1.14,
4 x 35M , 1.90% , 4539, 15M at 350, 56129, 1.12,
16 x 20M , 2.29% , 4756, 10M at 312, 53767, 1.13,
8 x 30M , 2.67% , 4974, 10M at 350, 59771, 1.12,
8 x 35M , 3.81% , 5627, 15M at 350, 71085, 1.12,

6000

12 x 20M

5000

4000

3000
Axial Load [kN]

2000

1000

0 100 200 300 400 500 600 700 800 900 1000

Moment [kN*m]

Page 1 of 1 Time Of Printing: 2011,Oct,08,(08:09)


Part of Reinforced Concrete Design - A Practical Approach, Svetlana Brev & John Pao