Flange
Movable machine
Bracket rail
Swivel bracket
1. To compensate offset, mount the bracket rail on the shaft end of the stationary machine.
2. Mount the swivel bracket on the bracket rail. Mount S transducer on the swivel bracket
3. Mount the magnet fixture on the end of the shaft of the movable machine. Mount
M transducer on the fixture.
4. Connect the S- and M- transducer to the display unit and start the Cardan program to
switch on the lasers.
5. Adjust the M transducer beam.
To adjust the laser beam: Turn the transducer into first position – e.g. 9
o’clock. Note the beam position on the opposite transducer (e.g. beam
hits position 1). Turn the unit half a turn (beam hits position 2). Adjust the
beam to the centre of rotation (beam hits position 3 in the middle between
point 1 and 2).
6. Adjust the brackets rail so the center of the S transducer is hit by the M transducer’ laser.
7. Adjust the S transducer beam.
value, confirm by .
Press to proceed.
Face the stationary machine from the movable machine. Turn both
transducers to position 9 o’clock (S and M-labels to the left).
Adjust the laser beams to the centre (green dots) of the closed
After the third value taken device goes to the result screen