Variable-area flowmeter
l
Complete family with different displays
l
Local indication without the need for auxiliary power
l
Measurement in all flow directions
l
Rugged design for extreme operating conditions
l
Flexible and can be adapted to meet customer-specific requirements
l
Special food & pharmaceutical models
H250
H 250
...process flow measurement can't be easier
or more adaptable
Special features
Measuring section
Resistant
l to extreme chemical, mechanical and thermal loads
Measuring
l section of rugged all-metal construction
Description All components replaceable
Tapered measuring tube
l
The H 250 flowmeter for liquids and gases All weld seams accessible for X-ray examination
l
is an all-metal flowmeter which operates on Bunched bar magnets in the float ensure interference-free
l
the float principle. Depending on the data transmission
flowrate, the float will assume a certain Float damper made of aluminium oxide (Al2O3),
l
vertical position in the tube. The float can also be retrofitted
position is transmitted by a magnetic Heating jacket available for the measuring section
l
coupling system to the scale. The flowmeter
is designed for installation in a vertical pipe M9 indicator
run with flow from bottom to top. The
rugged construction of the H 250 variable- Direct
l flow indication
area flowmeter makes it particularly Indirectly
l mounted indicator (HT version) for use in
suitable for difficult application and conjunction with high process temperatures
environmental conditions. The H 250 Electrical signal output (ESK II)
l
flowmeter can be equipped with the with HART® communication (can be retrofitted)
M9 indicator. One or two limit switches (K) adjustable on the scale
l
(can be retrofitted)
In the M9 indicator the rotational Multipole ring magnet with eddy-current brake
l
movement of the follower magnet system is
transmitted to the indicator without being ESK electrical current output
linearized and the flowrate value is
Float
l position sensed by magnetic sensors
indicated directly on the scale.
Non-interacting and hysteresis-free conversion of the flow
l
value into a scaled current output (4-20 mA)
Linearization of the current output via electronic
l
memory module
2
H250
A module
l rack in the M9 indicator accommodates all electrical Should
l process temperatures exceed the max.
components and also the scale plate. allowable temperatures for the standard version, the
indicator can be subsequently fitted with an adapter to
The modules
l of the ESK II, K1 or K2 electrical options and the suit the new operating conditions.
scale plate are simply plugged into the module rack.
The
l flowmeter can be initially equipped or retrofitted
The modules
l can be replaced or retrofitted without interrupting with magnetic filters and/or a float damper.
the process.
Various
l materials and different liners are available for the
measuring section.
The variable-are flowmeter The H 250 variable-area flowmeter with M9 indicator is certified for
Type: H250/M9/ESK II use in hazardous areas by the Physikalisch - Technische
Bundesanstalt in versions EEx ia IIC T6...T3 and EEx ib IIC T6...T3.
conforms with the requirements of Directive 89/336/EEC H 250/M9: PTB No.: Ex-97.D.2171
and the following European Standards:
EN 50081-1
EN 50082-2
and also the requirements of the
NAMUR Recommendations NE/21/05/93
3
H250
Technical data
Measuring range (100% values), select measuring range from flow table
Water 20°C, (68°F) 25 to 100000 l/h (0.11 to 440.3 US GPM)
Air 1.013 bar abs. (14.7 psia), 20°C (68°F) 0.7 to 600 m3 /h (0.43 to 372.2 SCFM)
Measuring tube
H 250/RR metal tube with tapered measuring section
H 250/PTFE measuring tube with orifice plate
Float shapes
H 250/RR
Liquids CIV, DIV
Gases TIV, DIV (damping possible)
H 250/PTFE
Liquids, gases type E, tapered
The max. allowable operating pressure for the flanges is dependent on the process temperature & is specified in the relevant
standards. For 150 lb and 300 lb ANSI flanges: see ASME/ANSI B 16.5.1988 Standard, and for DIN flanges: see (DIN 2401 Part
12.
Meter sizes
with flange connections DN 15 to DN 100 and ½" to 4"
only H 250/RR
with heating jacket DN 15 to DN 100 and ½" to 4" (max. DN 80/3" for "Ex" units)
Connections
Flanges to DIN 2501 DN 15, DN 25, DN 50/PN 40; DN 80, DN 100/PN16
Flanges to ANSI B 16.5 ½" to 4"/Class 150 lbs/RF or Class 300 lbs/RF
only H 250/RR
Flanges for heating jacket DN 15, DN 25/PN 40, (½", 1"/Class 150 lbs/RF)
Tube for heating jacket Ermeto 12
Overall height
with flanged connection (excl. gaskets) 250 mm (9.84")
4
H250
Technical data
DN 15/25 ½", 1" DN 15 1/2" M9/ESK 200 392 180 (150) 356 (302)
M9/HT/ESK 300 572 300 (235) 572 (455)
M9/ESK-Z 200 392 80 176
M9/HT/ESK-Z 300 572 130 266
M9/K 200 392 200 (150) 392 (302)
M9/HT/K 300 572 300 (235) 572 (455)
M9/KD 200 392 130 266
M7/ESK 200 (180) 392 (356) 165 (110) 329 (230)
M7/K 200 (180) 392 (356) 200 (110) 392 (230)
DN 50 2" DN 25 1" M9/ESK 200 392 165 (125) 329 (257)
M9/HT/ESK 300 572 300 (170) 572 (338)
M9/ESK-Z 180 356 75 167
M9/HT/ESK-Z 300 572 100 212
M9/K 200 392 200 (125) 392 (257)
M9/HT/K 300 572 300 (170) 572 (338)
M7/ESK 190 (150) 374 (302) 145 (100) 293 (212)
DN 80/100 3", 4" DN 50 2", 3" M9/ESK 200 392 150 (105) 302 (221)
DN 80 M9/HT/ESK 300 572 250 (145) 482 (293)
M9/ESK-Z 150 302 70 158
M9/HT/ESK-Z 270 518 85 185
M9/K 200 392 200 (105) 392 (221)
M9/HT/K 300 572 300 (145) 572 (293)
M9/KD 190 374 110 (105) 230 (221)
M7/ESK 180 (145) 356 (293) 135 (90) 275 (194)
Instrument versions
Version Materials
Measuring tube Flanges Float Internals Standard
Seal strips orifice plate
5
H250
Indication and long-distance data transmission Limit switches SC 2-NO/SC 3,5-NO-Y/SJ 3,5-E2
SC 2-NO/SC 3,5-NO-Y SJ 3,5-E2
Limit switches Rated voltage 8 V DC 10 to 30 V DC
One or two limit switches can be built into the indications Power consumption/output
Contact Indicator Max. number active area clear 3 mA ≤ 0.3V
SC 3,5-NO-Y (2-wire) M9 2 active area obscured 1 mA UB – 3 V
≤
SJ 3,5-E2 (3-wire) M9 2 Ambient temperature
at limit switch – 25°C + 100°C – 25 to + 27°C
Limit switches in 2-wire circuitry are connected in conformity with
(– 13°F to + 212°F) (– 13°F to + 158°F)
DIN 19234 (NAMUR), limit switches in 3-wire circuitry have a DC
Continuous current 100 mA (SJ 3,5-E2 only)
voltage connection of 10 to 30 V DC. The switching point is
No-Load power ≥ 15 mA (SJ 3,5-E2 only)
visible on the scale. An disconnect switching amplifier is required
for operation of one limit switch in 2-wire circuitry. consumption
Protection category
Isolation switching Power supply Channel Order No. (EN 60529/IEC 529) IP 67, equivalent to NEMA 6
amplifier Electromagnetic
KHA6-SR2-Ex1.W 230 V AC 1 5015262000 compatibility (EMC) to EN 50081-1, EN 50082-2
KHA5-SR2-Ex1.W 110 V AC 1 5015262100
KHD-2-SR2-Ex1.W 24 V DC 1 5015262200 Electrical characteristics to DIN 19234 (NAMUR)
KHA6-SR2-Ex2.W 230 V AC 2 5015262300 Only relevant for use in hazardous area!
KHA5-SR2-Ex2.W 110 V AC 2 5015262400 Only for connection to intrinsically safe circuits with the
KHD2-SR2-Ex2.W 24 V DC 2 5015262500 following peak values:
No-load voltage Uo 15.5 V
Limit switches in 3-wire circuitry (with integrated preamplifier) can
Short-circuit voltage lk 52 mA
be connected directed to a PLC system.
Output P 169 mW
Self-inductance (Li) 150 µ H
Contact mode of operation
Self-capacitance (Ci) 150 nF
An alarm is initiated when the contact vane dips into the sensor
Individual approval PTB-No. Ex-95.D.2195X
(active area is obscured).
Limit Switch SJ 3,5-E2 not for hazardous-duty application
For contacts SC 3,5 No-Y and SJ 3,5-E2, an alarm can, on M9 indicator
request, be initiated when the contact vane emerges from the SC 2-NO / SC 3,5-NO-Y SJ 3,5-E2
sensor (active area is clear).
DC DC
K1 K2 1 2 3 4 5 6
brown black blue brown black blue
M9 indicator K1 K2
K1 K2
Contact KMIN KMAX BN
SC 3,5-NO-Y (standard) – + – +
SJ 3,5-E2 + DC – + DC –
K1 = 1 Limit switch
Terminal 1 blue – / Terminal 2 brown +
K2 = 2 Limit switches
Terminal 3 blue – / Terminal 4 brown +
6
H250
With an intrinsically safe feed unit, the transmitter Temperature influence <5µ
A/ K
may also be used in hazardous areas. Max. load resistance/load impedance 0 (250**) to 800 ohms
Individual approval PTB No. Ex-97.D.2091
Conversion of the ESK II( to other products or * Without considering the resolution steps
measuring ranges can be carried out by using a ** With HART® Communication, these values are minimum and must be adhered to.
HART® communicator. 2-wire circuit Rext [kΩ
]=
(power supply [V] –12,7 V [12,0 for ESK II]/20 mA)
Connection Diagram Ambient temperature ESK – 25° to + 80°C (– 13°F to + 176° F)
Temperature in storage – 40° to + 85°C (– 40°F to + 185° F)
Ub 12(18*)É30VDC Rext.
0(250*)É800 Ohm
Protection category
Rest 4....20mA
4mA 20mA
*HART (EN 60529 / IEC 529) IP 20
Only for connection to intrinsically safe circuits with the following peak values:
11+
12+ No-load voltage Uo 30 V
Short-circuit current lk 100 mA
Output P 1W
Effective inner self-capacitance < 20nF
Effective inner self-inductance negligible
In order, the type designation of the instrument is extended by the following symbols:
Version Designation
SC 2-NO, SC 3,5-No-Y (2-wire configuration) K1 (1 contact), K2 (2 contacts)
SJ 3,5-E2 (3-wire configuration)
Electrical signal output ESK
High-temperature version
For high process temperatures up to 300°C (572°F), the M9 indicator can be fitted with the HT extension. The indicator
is then 80 mm (3.15") away from the measuring tube.
Plunger (Al2O3)
Damping tube
Float
7
H250
H 250
Flow table
H 250/RR
50 2" K 55.1 6300 27.74 – – 80 49.63 230 142.7 74 1.07 13 0.19 60 0.87
K 55.2 10000 44.03 – – 110 68.24 350 217.1 77 1.12 13 0.19 69 1.00
K 55.3 16000 70.45 25000 110.00 150 93.05 600 372.2 84 1.22 13 0.19 104 1.51
100 4" L 105.1 63000 277.40 100000 440.30 – – – – 120 1.74 – – 220 3.19
* Not for instruments fitted with heating device ** 300 mbar (4.35 psig) with damper (gas service)
8
H250
H 250/PTFE
* Not for instruments fitted with heating device ** 300 mbar (4.35 psig) with damper (gas service) with float shape DIV T
Damper recommended:
for TIV floats with an operating (inlet) pressure of The specified pressure losses apply to water and air at max. flowrate.
≤ 0.3 bar (≤ 4.35 psig) [DN 15, dn 25 (½", 1")] Conversion to other process liquids or operating data
0.2 bar (≤
≤ 2.90 psig) [DN 50 (2")], and generally (pressure, temperature, density, viscosity) can be made using the
when DIV floats are used for gas service. calaculation method specified in VDE / VDI Code 3513.
9
H250
15 40 ½" 150/300 107 (4.21) 178 (7.01) 100 (3.94) 20 (0.79) 3.5 7.72 4.8 10.58
25 40 1" 150/300 119 (4.69) 189 (7.44) 106 (4.17) 32 (1.26) 5.2 11.46 6.7 14.77
50 40 2" 150/300 132(5.20) 203 (7.99) 120 (4.72) 65 (2.56) 8.7 19.18 10.4 22.93
80 16 3" 150/300 148 (5.83) 219 (8.62) 160 (6.30) 89 (3.50) 12.0 26.46 14.0 30.86
100 16 4" 150/300 158 (6.22) 235 (9.25) 150 (5.91) 114 (4.49) 14.0 30.86 16.6 36.60
* DN 25 plus 0.75 kg, Ermeto 12 minus 0.9 kg ** Weight of instruments with DIN flanges
H 250/M9
181(7.13")
110.5 (DN15,DN25)/123.5 (DN50 to DN100) L
4.35"( 1 / 2 ", 1") / 4.86" (2" to 4")
250 (9.84")
138 (5.43")
M16x1.5
13 dia. d
(0.51")
H 250/M9 H 250/M9/HT
L1 L + 80 mm (L + 3.15Ó)
150 (5.91")
M16· 1.5
dia. d
10
H250
H 250/M9
11
Krohne Marshall Pvt. Ltd.
(A Forbes Marshall Company)
A-34/35, MIDC,
Industrial Estate, Tel.: 91(0)20 - 27442020
'H' Block, Pimpri, Fax: 91(0)20 - 27442040
Pune - 411 018. India. E-mail: ksales@forbesmarshall.com
H250