Techno NDT Services


NDT Specialist & Welding Inspection Website: www.technondt.com
Email: technondt2017@gmail.com
# 139/A Malligai nagar, Parthasarrthi street, chinnasekkadu, manali, chennai. Ph: 044-25942438 +91-99406 99267

ULTRASONIC FLAW DETECTION REPORT


CLIENT: MANALI PETROCHEMICALS LTD PLANT II REPORT.NO: TNS-UFD-130 /19
MANALI CH-68 DATE: 11TH APRIL 2019

(A) JOB DESCRIPTION


JOB ID : 4” SR7201 ‘C’ CL2 BULLET M1 NOZZLE JOINTS Scanning From : Weld Area
Scanning Position : Shar Wave
(B) TEST DETAILS

Method : Contact Pulse Echo


Scanning : Manual
Couplant : Oil
Surface Condition : Smooth
Scanning Surface : On Weld
Equipment Model & Make : Einstein II TFT & Modsonic
Equipment Serial No : E2923-0311
(C) PROBE DETAILS ST.Beam
Make : Modsonic Test Range : 0-100mm
Probe Type : MMS-2 Raf.Echo Amp : 48 db
Size/MHz : 10mmØ /2MHz Scanning Sensitivity : 48 + 6db
SL.NO : 782
Angle : 70° & 45°

(D) CALIBRATION DETAILS


Calibration Method : Step Block
Reference Reflector : Notches & side Drilled Hole
Ref Block : V1 Block & V2
Ref Block Thk : 12.5 mm Ø
Resolution : IIW VI Block
Sensitivity : 1.5mm Ø
(E) SYSTEM CALIBERATION
Sweep Range Tolerance + 2%
For Normal Probe: Horizontal & Vertical Linear Calibration / VI & V2 Block
Horizontal Vertical Linearity Calibration: 6db Drop Method ok
(F) OBSERVATION & RESULT
Sl.No Job Description Joint No Evoliution Result

01 4” SR7201 ‘C’ CL2 BULLET M1 INSIDE N09


02 4” SR7201 ‘C’ CL2 BULLET M1 INSIDE N10 No Linear indication Acceptable
03 4” SR7201 ‘C’ CL2 BULLET M1 OUT SIDE N09 Observation
04 4” SR7201 ‘C’ CL2 BULLET M1 OUT SIDE N10

TNS ASNT LEVEL II CUSTOMER CLIENT