2.

LOAD CALCULATION
2.1 SELF -WEIGHT OF STRUCTURE

The self - weight of structure has been calculated by using STAAD PRO
Software with "SELFWEIGHT" command

2.2 DEAD LOAD


a) Water Proofing Load

Light weight cellular screed concrete

Avg. 95mm Thick (min. 40mm, max. 150mm) = 0.095 x 8

= 0.76 kN/m2

Geo textile Membrane

50thk Insulation

4mm Water Proofing membrane = 0.50 kN/m2

Bituminous Primer

25mm Damp proofing (Sand cement morter) = 0.50 kN/m2

50mm thick tiles = 1.10 kN/m2

2.86 kN/m
2
Total Load

b) Load Due to Soil Weight on Footing:-

Unit Weight of soil = 18.00 kN/m3

(Ref cl.7.3 in doc.J08423A-S-SP-18019,Rev D1)

Depth of Footing Conisdered From FGL = 2.00 m

Thickness of footing Considered = 0.50 m

Depth of soil Above footing = 1.50 m

Soil Pressure on footing top = 18 x 1.5 = 27.0 kN/m2

2.3 PIPING/HVAC DUCT AND CABLE TRAY LOAD (PDCL)


HVAC Duct and Cable Tray = 3.00 kN/m2

2.4 ROOF LIVE LOAD


# Sensitivity: LNT Construction Internal Use
Roof live load = 1.50 kN/m2

# Sensitivity: LNT Construction Internal Use


# Sensitivity: LNT Construction Internal Use
# Sensitivity: LNT Construction Internal Use
Duopitched Canopy Roofs

Fundametal value of
Vb.0 the Basic wind Vb.0
velocity

Cdir Direction Factor Cdir


Cseason Season Factor Cseason

Vb Basic wind velocity Cdir x Cseason x Vb.0 1x1x33

Terrain category

Terrain Zone
Zo Roughness length
Zmin
Zmax
Z0,II
Z Reference height

kr Terrain factor 0.19 x (zo/zo,II)0.07 Err:511


Cr(Z=z) Zmin <= Z <=Zmax kr x In (z/zo) Err:511
Cr(Z=zmin) Z < Zmin kr x In (zmin/zo) Err:511
Cr(z) Roughness Factor

Co(z) Assuming avg.slope of


Orography Factor
upward terrain < 30

Vm(z) Mean Wind Velocity Cr(z) x C0(z) X Vb Err:511

Kl Turbulence factor
Co(z) Orograpgy factor
lv(Z=z) Zmin <= Z <=Zmax Kl/(C0(z)*ln(Z/Zo)) Err:511
lv(Z=zmin) Z < Zmin Err:511
lv(Z) Turbulence intensity

Peak Velocity
qp(z) [1+7*Iv(z)]*(0.5)*r*v2m(z) Err:511
Pressure

# Sensitivity: LNT Construction Internal Use


CsCd 1 Ref: 6.2.(1).b)

Roof angle 5

Pressure Coefficients Zone A Zone B Zone C


Maximum Value 0.6 1.8 1.3
Minimum Value
-0.6 -1.4 -1.4
0 Blockage
Minimum Value
-1.3 -2 -1.8
1 Blockage

Pressures on roof
Zone A Zone B Zone C
kN/m2
Maximum Value 0.89533 2.68599 1.93988
Minimum Value
-0.89533 -2.08911 -2.08911
0 Blockage
Minimum Value
-1.93988 -2.98444 -2.68599
1 Blockage

Force Coefficients
Maximum Value 0.3
Minimum Value
-0.6
0 Blockage
Minimum Value
-1.3
1 Blockage

# Sensitivity: LNT Construction Internal Use


SUMAIL
33 m/sec INDUSTRIAL
ESTATE

1 Note 2 eqn 4.1


1 Note 3 eqn 4.1
eqn 4.1 BS EN
33 m/sec
1991-1-4:2005

Area with low vegetation


such as grass and
isolated obstacles
Table 4.1
(trees, buildings) with
seperations of at least
20 obstacle heights

II
0.05 m Table 4.1
2 m Table 4.1
200 m
0.05 m
7.725 m

0.19
0.958
0.701
0.958

1 4.3.1

31.614 m/sec eqn 4.3

1
1
0.19841
0.27109
0.19841

1.25 Kg/m3 Note 2 equ 4.10

1492.2151047466 N/m2

# Sensitivity: LNT Construction Internal Use


Zone D
0.400
-1.100

-1.500

Zone D
0.59689
-1.64144

-2.23833

# Sensitivity: LNT Construction Internal Use


Wind load calculation
Wind force is calculated based on the wind presses & procedure as provided in cl. 5.1.9 in Civil & Structural Design Basis.

Extreme Wind (qh) Normal Wind (qh)


h (m)
(kN/m2) (kN/m2)
Up to 5 1.35 0.77
6 1.39 0.8
7 1.43 0.82
8 1.46 0.84
9 1.5 0.86
10 1.53 0.88
11 1.56 0.89
12 1.6 0.91
13 1.63 0.93
14 1.66 0.95
15 1.68 0.96
16 1.71 0.98
17 1.74 0.99

General data:
Building maximum height = 6.85 m
Building maximum length = 67.325 m
Building maximum width = 21.8 m

As per above table the following wind pressure consider for building design

Extreme condition = 1.43 KN/m2

Normal condition = 0.82 KN/m2

External pressure coefficient for rectangular building wall

Windward wall = 0.8


Leeward wall = -0.5
Side walls = -0.7

Internal pressure coefficient for rectangular building (opening < 5%)

Closed structures = +0.3 / -0.3

# Sensitivity: LNT Construction Internal Use


# Sensitivity: LNT Construction Internal Use
Load Case - 19 When the wind is acting along 0 o direction of pressure WEP(+Z)

WIND
0.5 0.8
A

C 0.3 D Z
0.7 0.7 Reference STAAD axis
1 1

B
0.8 0.5

Sl Net Net Staad


No pressure Pressure Axis
Wind force along direction
Coefficient P, kN/m2

1 C (side) 1 1.430 X
2 D (Side) 1 1.430 -X
3 A (Windward ) 0.5 0.715 Z
4 B (Leeward ) 0.8 1.144 -Z

Load Case - 20 When the wind is acting along 0 o direction of suction WES(+Z)

1.1 0.8
A

C 0.3 D Z
0.7 0.7 Reference STAAD axis
0.4 0.4

B
0.2 0.5

Sl Net Net Staad


No pressure Pressure Axis
Wind force along direction
Coefficient P, kN/m2

1 C (side) 0.4 0.572 X


2 D (Side) 0.4 0.572 -X
3 A (Windward ) 1.1 1.573 Z
4 B (Leeward ) 0.2 0.286 -Z

# Sensitivity: LNT Construction Internal Use


Load Case - 21 When the wind is acting along 0 o direction of pressure WEP(-Z)

0.8 0.5
A

C 0.3 D Z
0.7 0.7 Reference STAAD axis
1 1

B
0.5 0.8
WIND

Sl Net Net Staad


No pressure Pressure Axis
Wind force along direction
Coefficient P, kN/m2

1 C (side) 1 1.430 X
2 D (Side) 1 1.430 -X
3 A (Leeward ) 0.8 1.144 Z
4 B (Windward ) 0.5 0.715 -Z

Load Case - 22 When the wind is acting along 0 o direction of suction WES(-Z)

0.2 0.5
A

C 0.3 D Z
0.7 0.7 Reference STAAD axis
0.4 0.4

B
1.1 0.8
WIND

Sl Net Net Staad


No pressure Pressure Axis
Wind force along direction
Coefficient P, kN/m2

1 C (side) 0.4 0.572 X


2 D (Side) 0.4 0.572 -X
3 A (Leeward ) 0.2 0.286 Z
4 B (Windward ) 1.1 1.573 -Z

# Sensitivity: LNT Construction Internal Use


# Sensitivity: LNT Construction Internal Use
Load Case - 23 When the wind is acting along 90 o direction of pressure WEP (+X)

1 0.7
A

X
WIND
C 0.3 D Z
0.8 0.5 Reference STAAD axis
0.5 0.8

B
1 0.7

Sl Net Net Staad


No pressure Pressure Axis
Wind force along direction
Coefficient P, kN/m2

1 C (Windward ) 0.5 0.715 X


2 D (Leeward ) 0.8 1.144 -X
3 A (side) 1 1.430 Z
4 B (side) 1 1.430 -Z

Load Case - 24 When the wind is acting along 90 o direction of suction WES (+X)

0.4 0.7
A

X
WIND
C 0.3 D Z
0.8 0.5 Reference STAAD axis
1.1 0.2

B
0.4 0.7

Sl Net Net Staad


No pressure Pressure Axis
Wind force along direction
Coefficient P, kN/m2

1 C (Windward ) 1.1 1.573 X


2 D (Leeward ) 0.2 0.286 -X
3 A (side) 0.4 0.572 Z
4 B (side) 0.4 0.572 -Z

# Sensitivity: LNT Construction Internal Use


# Sensitivity: LNT Construction Internal Use
Load Case - 25 When the wind is acting along 90 o direction of pressure WEP (-X)

1 0.7
A

WIND X

C 0.3 D Z
0.5 0.8 Reference STAAD axis
0.8 0.5

B
1 0.7

Sl Net Net Staad


No pressure Pressure Axis
Wind force along direction
Coefficient P, kN/m2

1 C (Leeward ) 0.8 1.144 X


2 D (Windward ) 0.5 0.715 -X
3 A (side) 1 1.430 Z
4 B (side) 1 1.430 -Z

Load Case - 26 When the wind is acting along 90 o direction of suction WES (-X)

0.4 0.7
A

WIND X

C 0.3 D Z
0.5 0.8 Reference STAAD axis
0.2 1.1

B
0.4 0.7

Sl Net Net Staad


No pressure Pressure Axis
Wind force along direction
Coefficient P, kN/m2

1 C (Leeward ) 0.2 0.286 X


2 D (Windward ) 1.1 1.573 -X
3 A (side) 0.4 0.572 Z
4 B (side) 0.4 0.572 -Z

# Sensitivity: LNT Construction Internal Use