Вы находитесь на странице: 1из 39

WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN.

REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

A A

CUSTOMER : Intermalt

B B

ORDER : 8160003065 ITEM : 10000

PROJECT : Intermalt
C C

SWITCHGEAR NAME : 12kV Switchgear GEN

D D
DESIGNATION OF UNIT : H01, H02

TYPE OF UNIT : SBC


E E

DOCUMENT : Circuit Diagram

F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved COVER SHEET Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en A01 A03
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

INDEX OF SHEETS STANDARD REFERENCES


SHEET DESCRIPTION REVISION
A THIS DRAWING IS IN COMPLIANCE WITH THE FOLLOWING INTERNATIONAL STANDARDS: A
A01 COVER SHEET A - IEC 60617: GRAPHICAL SYMBOLS FOR DIAGRAMS
A03 INDEX OF SHEETS A - IEC 61082: PREPARATION OF DOCUMENTS USED IN ELECTROTECHNOLOGY
A05 REVISION LIST A - IEC 81346: STRUCTURING PRINCIPLES AND REFERENCE DESIGNATIONS

A10 REFERENCE DESIGNATIONS A THE DIAGRAM INDICATES COMPONENTS HAVING A MOVABLE PART IN THE FOLLOWING POSITION OR
A11 REFERENCE DESIGNATIONS A OPERATIONAL STATE (IEC 61082-1 7.4.4.1):
A12 REFERENCE DESIGNATIONS A - C.BREAKER OR CONTACTOR IN OPEN (OFF) AND SERVICE POSITION
- DISCONNECTORS AND EARTHING SWITCH IN OPEN POSITION
D01 DISTRIBUTION OF AUXILIARY CIRCUITS A
- WITHDRAWABLE VOLTAGE TRANSFORMERS IN CONNECTED POSITION
B G01 DISTRIBUTION OF AUXILIARY CIRCUITS A B
- CLOSING SPRINGS OF C.BREAKER IN DISCHARGED POSITION
M03 CONTROL CIRCUITS A - CONNECTOR OF C.BREAKER AUXILIARY CIRCUITS IN CONNECTED POSITION
N01 CONTROL CIRCUITS A - CIRCUITS IN DE-ENERGIZED STATE
N02 CONTROL CIRCUITS A - RELAYS IN NON-ACTUATED STATE
- GAS PRESSURE AT RATED SERVICE VALUE
N05 CONTROL CIRCUITS A
- FUSES NOT OPERATED
N06 CONTROL CIRCUITS A - DOORS AND PRESSURE RELIEF FLAPS IN CLOSED POSITION
N07 CONTROL CIRCUITS A
N08 CONTROL CIRCUITS A
C Q02 AVAILABLE CONTACTS A C
Q04 AVAILABLE CONTACTS A
Q05 AVAILABLE CONTACTS A
Q06 AVAILABLE CONTACTS A
S01 MAIN CIRCUITS A
S02 MAIN CIRCUITS A
S03 MAIN CIRCUITS A
S04 MAIN CIRCUITS A
X01 TERMINAL BLOCKS A
D D
X02 TERMINAL BLOCKS A
X03 TERMINAL BLOCKS A
X04 TERMINAL BLOCKS A
X05 TERMINAL BLOCKS A
X06 TERMINAL BLOCKS A
X07 TERMINAL BLOCKS A
X08 TERMINAL BLOCKS A
X09 TERMINAL BLOCKS A
E E
X10 TERMINAL BLOCKS A
X11 TERMINAL BLOCKS A
X12 TERMINAL BLOCKS A
X13 TERMINAL BLOCKS A
Z01 PARTS LIST A
Z02 PARTS LIST A
Z10 MV DEVICES CHARACTERISTICS A
F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved INDEX OF SHEETS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en A03 A05
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

INDEX REVISION LIST


A A
REV

DESCRIPTION DATE PREPARED APPROVED

A FIRST ISSUE 2016-07-05 INGLESE LOMBONI

E
B B
F

C C

D D

E E

F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved REVISION LIST Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en A05 A10
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

REFERENCE DESIGNATION -BGL1 POSITION SWITCH OF ELECTROMECHANICAL LOCK -RLE1


-BGS1, -BGS2 POSITION SWITCHES OF CIRCUIT-BREAKER SPRINGS
OF OBJECTS IN ELECTRICAL DOCUMENTS -BGS6, -BGS7 POSITION SWITCHES OF THE SPRINGS OF SWITCH-DISCONNECTOR FOR CONTROL CIRCUITS OF THE MOTOR
A OPERATOR A
(IN COMPLIANCE WITH STANDARD IEC 81346-2 AND ABB TECHNICAL STANDARD 2NBA000001) -BGT1 POSITION SWITCHES ON TRUCK SIGNALLING TRUCK IN SERVICE POSITION
-BGT2 POSITION SWITCHES ON TRUCK SIGNALLING TRUCK IN TEST POSITION
DESIGNATION DESCRIPTION -BGT3 POSITION SWITCH ON TRUCK SIGNALLING TRUCK NOT IN ISOLATING TRAVEL POSITION
-BGT4 POSITION SWITCHES ON SWITCHGEAR SIGNALLING TRUCK IN SERVICE POSITION
-AA MULTIFUNCTION UNIT (CENTRAL UNIT)
-BGT5 POSITION SWITCHES ON SWITCHGEAR SIGNALLING TRUCK IN TEST POSITION
-BAD1, -BAD4 CAPACITIVE VOLTAGE DIVIDER LOCATED ON PHASE L1
-BM HYGROSTAT
-BAD2, -BAD5 CAPACITIVE VOLTAGE DIVIDER LOCATED ON PHASE L2
-BPA4 PRESSURE SWITCH LOCATED IN CABLE COMPARTMENT FOR DETECTION OF INTERNAL ARCING
-BAD3, -BAD6 CAPACITIVE VOLTAGE DIVIDER LOCATED ON PHASE L3
-BPA5 PRESSURE SWITCH LOCATED IN CIRCUIT-BREAKER COMPARTMENT
-BAR VOLTAGE PROTECTION RELAY
B -BPA6 PRESSURE SWITCH LOCATED IN BUSBAR OR IN BUSBAR AND CIRCUIT-BREAKER COMPARTMENT FOR DETECTION B
-BAS1 VOLTAGE SENSOR LOCATED ON PHASE L1 OF INTERNAL ARCING
-BAS2 VOLTAGE SENSOR LOCATED ON PHASE L2 -BPS PRESSURE SWITCH LOCATED ON CIRCUIT-BREAKER
-BAS3 VOLTAGE SENSOR LOCATED ON PHASE L3 -BR FLAME DETECTORS, SMOKE DETECTORS
-BAT1 VOLTAGE TRANSFORMER LOCATED ON PHASE L1 -BT THERMOSTAT
-BAT2 VOLTAGE TRANSFORMER LOCATED ON PHASE L2 -BU BUCHHOLZ RELAY
-BAT3 VOLTAGE TRANSFORMER LOCATED ON PHASE L3 -BX1 UNIT WITH SENSORS FOR DETECTION OF INTERNAL ARCING
-BCD DIFFERENTIAL PROTECTIVE RELAY -BX2 ADDITIONAL CURRENT SENSING UNIT FOR DETECTION OF INTERNAL ARCING
-BCF FEEDER PROTECTION RELAY -BZ MULTIFUNCTION SENSORS
-BCG GENERATOR PROTECTION RELAY -BZ1 COMBINED CURRENT AND VOLTAGE SENSOR, LOCATED ON PHASE L1
-BCM MOTOR PROTECTION RELAY -BZ2 COMBINED CURRENT AND VOLTAGE SENSOR, LOCATED ON PHASE L2
C C
-BCN NEUTRAL (RESIDUAL) CURRENT TRANSFORMER -BZ3 COMBINED CURRENT AND VOLTAGE SENSOR, LOCATED ON PHASE L3
-BCP TRANSFORMER PROTECTION RELAY -CA CAPACITORS
-BCR CURRENT PROTECTION RELAY -EA1 LIGHTING LAMP LOCATED IN L.V. INSTRUMENT COMPARTMENT
-BCS1 CURRENT SENSOR LOCATED ON PHASE L1 -EA2 LIGHTING LAMP LOCATED IN CABLE COMPARTMENT
-BCS2 CURRENT SENSOR LOCATED ON PHASE L2 -EA4 LIGHTING LAMP LOCATED IN CIRCUIT BREAKER COMPARTIMENT
-BCS3 CURRENT SENSOR LOCATED ON PHASE L3 -EB1 HEATER LOCATED IN CABLE COMPARTMENT
-BCT1, -BCT4 CURRENT TRANSFORMER LOCATED ON PHASE L1 -EB3 HEATER LOCATED IN MOTOR CABINET
-BCT2, -BCT5 CURRENT TRANSFORMER LOCATED ON PHASE L2 -EB5 HEATER LOCATED IN L.V. INSTRUMET COMPARTMENT
-BCT3, -BCT6 CURRENT TRANSFORMER LOCATED ON PHASE L3 -EB8 HEATERS LOCATED IN RIGHT SIDE OF THE OPERATING MECHANISM ENCLOSURE
-BCZ DISTANCE PROTECTION RELAY -FA1 SURGE ARRESTER LOCATED ON PHASE L1
D D
-BEF FREQUENCY PROTECTION RELAY -FA2 SURGE ARRESTER LOCATED ON PHASE L2
-BER SUPERVISION RELAYS -FA3 SURGE ARRESTER LOCATED ON PHASE L3
-BES SYNCHRONIZING RELAY -FCD FUSE-DISCONNECTORS FOR PROTECTION OF AUXILIARY CIRCUITS
-BET THERMAL PROTECTION RELAY -FCF1 MEDIUM VOLTAGE FUSE LOCATED ON PHASE L1
-BGB1...-BGB3 POSITION SWITCHES OF CIRCUIT-BREAKER -FCF2 MEDIUM VOLTAGE FUSE LOCATED ON PHASE L2
-BGB5 POSITION SWITCH OF CIRCUIT-BREAKER SIGNALLING UNDERVOLTAGE RELEASE ENERGIZED -FCF3 MEDIUM VOLTAGE FUSE LOCATED ON PHASE L3
-BGB6 POSITION SWITCH OF CIRCUIT-BREAKER SIGNALLING UNDERVOLTAGE RELEASE EXCLUDED -FCM1 MINIATURE CIRCUIT-BREAKER FOR PROTECTION OF SPRINGS CHARGING MOTOR ON MAIN CIRCUIT-BREAKER
MECHANICALLY
-FCM2 MINIATURE CIRCUIT-BREAKER FOR PROTECTION OF CONTROL CIRCUITS
-BGD POSITION SWITCH OF L.V. INSTRUMENT COMPARTMENT DOOR
-FCM3 MINIATURE CIRCUIT-BREAKER FOR PROTECTION OF CIRCUIT-BREAKER SPRINGS CHARGING MOTOR
-BGD1 POSITION SWITCH OF CIRCUIT-BREAKER COMPARTMENT DOOR
E -BGD2 POSITION SWITCH OF CABLE COMPARTMENT DOOR
-FCM4 MINIATURE CIRCUIT-BREAKER FOR PROTECTION OF CIRCUITS OF MOTOR FOR SWITCH-DISCONNECTOR E
OPERATION
-BGE1 POSITION SWITCHES SIGNALLING EARTHING SWITCH -QCE IN OPEN POSITION -FCM5 MINIATURE CIRCUIT-BREAKER FOR PROTECTION OF AUXILIARY CIRCUITS IN ALTERNATING CURRENT
-BGE2 POSITION SWITCHES SIGNALLING EARTHING SWITCH -QCE IN CLOSED POSITION -FCM6 MINIATURE CIRCUIT-BREAKER FOR PROTECTION OF BROKEN DELTA SECONDARY CIRCUITS OF VOLTAGE
TRANSFORMERS
-BGF POSITION SWITCHES OF MEDIUM VOLTAGE FUSES
-FCM7 MINIATURE CIRCUIT-BREAKER FOR PROTECTION OF STAR CONNECTION SECONDARY CIRCUITS OF VOLTAGE
-BGI7 POSITION SWITCH SIGNALLING DICONNECTOR (OR SWITCH-DISCONNECTOR) -QBD NOT IN MANUAL OPERATION TRANSFORMERS, FIRST WINDING
-FCM8 MINIATURE CIRCUIT-BREAKER FOR PROTECTION OF STAR CONNECTION SECONDARY CIRCUITS OF VOLTAGE
-BGI41... POSITION SWITCHES SIGNALLING SWITCH-DISCONNECTOR -QBS CLOSED IN FEEDER POSITION TRANSFORMERS, SECOND WINDING
-BGI43... POSITION SWITCHES SIGNALLING SWITCH-DISCONNECTOR -QBS CLOSED IN EARTH POSITION -FCM9 MINIATURE CIRCUIT-BREAKER FOR PROTECTION OF CIRCUITS OF PROTECTION RELAYS OR MULTIFUNCION
-BGK POSITION SWITCH OF KEY LOCK UNITS

F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved REFERENCE DESIGNATIONS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en A10 A11
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8
-FCT THERMAL OVERLOAD RELEASES -PGS SYNCHRONOSCOPES
-GA GENERATORS -PGV VOLTMETERS
-KFA1 AUXILIARY RELAY SIGNALLING LOW GAS PRESSURE -PGW WATTMETERS
A -KFA2 AUXILIARY RELAY SIGNALLING INSUFFICIENT GAS PRESSURE -PJ ACOUSTICAL SIGNAL DEVICES (BELLS, SIRENS) A
-KFA3...-KFA9 AUXILIARY RELAYS OR CONTACTORS -QAB CIRCUIT-BREAKERS
-KFC CLOSING RELAYS OR CONTACTORS -QAC CONTACTORS (FOR POWER)
-KFI INTEGRATED CIRCUITS -QBD DISCONNECTORS
-KFL LOCKOUT RELAY -QBH MANUAL CIRCUIT-BREAKERS
-KFM MICROPROCESSORS -QBL LINKS
-KFN ANTIPUMPING RELAYS -QBM MINIATURE SWITCH-DISCONNECTORS
-KFO OPENING RELAYS OR CONTACTORS -QBS SWITCH-DISCONNECTORS
-KFP PROGRAMMABLE LOGIC CONTROLLERS (PLC) -QBT TRUCK
B -KFR RECLOSING RELAYS -QCE EARTHING SWITCH B
-KFS SYNCHRONIZING DEVICES -QQ CLUTCHES
-KFT AUXILIARY TIME RELAYS, DELAY ELEMENTS -RAA FERRO-RESONANCE DUMPING RESISTOR
-KFU CONTROL UNIT -RAD DIODES
-KFZ CONTROLLERS -RAI INDUCTORS
-MAD MOTOR FOR ELECTRICAL OPERATION OF SWITCH-DISCONNECTOR -QBS -RAR RESISTORS
-MAE MOTOR FOR ELECTRICAL OPERATION OF EARTHING SWITCH -QCE -RF FILTERS
-MAS MOTOR FOR CIRCUIT-BREAKER SPRINGS CHARGING -RLE1 ELECTROMECHANICAL LOCK PREVENTING CIRCUIT-BREAKER CLOSING
-MAT MOTOR FOR ELECTRICAL OPERATION OF TRUCK RACKING-IN/OUT -RLE2 ELECTROMECHANICAL LOCK PREVENTING TRUCK RACKING-IN/OUT
-MBC CLOSING RELEASE OF CIRCUIT-BREAKER -RLE3 ELECTROMECHANICAL LOCK PREVENTING INSERTION OF LEVER FOR CLOSING OPERATION OF EARTHING SWITCH
C -MBC4 CLOSING RELEASE OF SWITCH-DISCONNECTOR -QBS -RLE4 ELECTROMECHANICAL LOCK PREVENTING THE DOOR OPENING OPERATION C
-MBO1 FIRST OPENING RELEASE OF CIRCUIT-BREAKER -RLE5 ELECTROMECHANICAL LOCK PREVENTING INSERTION OF LEVER FOR CLOSING OPERATION OF LINE SWITCH
-MBO2 SECOND OPENING RELEASE OF CIRCUIT-BREAKER
-SFA AMMETRIC SWITCHES
-MBO3 OPENING SOLENOID FOR OVERCURRENT RELEASE OF CIRCUIT-BREAKER
-SFC CONTROL SWITCHES, CLOSING PUSH-BUTTONS
-MBO4 OPENING RELEASE OF SW ITCH-DISCONNECTOR -QBS
-SFL LOCKING CONTACTS
-MBU UNDERVOLTAGE RELEASE OF CIRCUIT-BREAKER
-SFM MOTOR CONTROL PUSH-BUTTON
-MBU4 UNDERVOLTAGE RELEASE OF SWITCH-DISCONNECTOR -QBS
-SFO OPENING PUSH-BUTTONS
-PFB BLUE SIGNAL LAMPS
-SFR RESET PUSH-BUTTONS
-PFF FLAG RELAYS
-SFS SELECTOR SWITCHES
-PFG GREEN SIGNAL LAMPS
D -SFT TEST PUSH-BUTTONS D
-PFR RED SIGNAL LAMPS
-SFU UNLOCKING PUSH-BUTTONS
-PFS SHORT CIRCUIT INDICATORS
-SFV VOLTMETRIC SWITCHES
-PFV VOLTAGE INDICATORS
-TA POWER TRANSFORMERS
-PFV1 VOLTAGE INDICATOR ON FEEDER SIDE
-TB CONVERTER
-PFV2 VOLTAGE INDICATOR ON BUSBAR SIDE
-TFA ACTIVE POWER TRANSDUCERS
-PFW WHITE SIGNAL LAMPS
-TFC CURRENT TRANSDUCERS
-PFX CROSS INDICATORS, ELECTROMECHANICAL INDICATORS
-TFF FREQUENCY TRANSDUCERS
-PFY YELLOW SIGNAL LAMPS
-TFJ ACTIVE ENERGY TRANSDUCERS
-PGA AMMETERS
-TFK REACTIVE ENERGY TRANSDUCERS
-PGC COUNTERS
E -PGF FREQUENCYMETERS
-TFM MULTIFUNCTION TRANSDUCERS E
-TFP POWER-FACTOR TRANSDUCERS
-PGH HOURMETERS
-TFQ REACTIVE POWER TRANSDUCERS
-PGI PROTECTION AND CONTROL UNIT: HUMAN MACHINE INTERFACE
-TFS SIGNAL CONVERTERS
-PGJ ACTIVE ENERGY METERS
-TFV VOLTAGE TRANSDUCERS
-PGK REACTIVE ENERGY METERS
-WA BUSBARS
-PGM MULTIFUNCTION INDICATORS
-WBC POWER CABLES
-PGP POWER-FACTOR METERS
-WE EARTHING CABLES FOR L.V. INSTRUMENT COMPARTMENT
-PGQ VARMETERS
-WGC CONTROL CABLES
F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved REFERENCE DESIGNATIONS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en A11 A12
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

-WGS COMMUNICATION CABLES (SHIELDED TW ISTED PAIRS) -XE6 EARTHING TERMINAL BLOCK FOR CABLE COMPARTMENT, REAR BOTTOM SIDE
-WH OPTICAL FIBRES -XE20 EARTHING TERMINAL BLOCK FOR CURRENT TRANSFORMERS
-XDA TERMINAL BLOCK FOR CIRCUITS OF CURRENT TRANSFORMERS -XE21 EARTHING TERMINAL BLOCK FOR VOLTAGE TRANSFORMERS
A A
-XDA1 CONNECTOR FOR CIRCUITS OF CURRENT TRANSFORMERS ON PHASE L1
-XDA2 CONNECTOR FOR CIRCUITS OF CURRENT TRANSFORMERS ON PHASE L2
-XDA3 CONNECTOR FOR CIRCUITS OF CURRENT TRANSFORMERS ON PHASE L3
-XDA5 CONNECTOR FOR CIRCUITS OF NEUTRAL (RESIDUAL) CURRENT TRANSFORMER
-XDB CONNECTOR FOR ISOLATION OF CIRCUIT-BREAKER
-XDB1 TERMINAL BLOCK FOR AUXILIARY CIRCUITS OF CIRCUIT-BREAKER
-XDB2 TERMINAL BLOCK FOR ADDITIONAL AUXILIARY CIRCUITS OF CIRCUIT-BREAKER
-XDB10...-XDB89 CONNECTOR FOR CIRCUIT-BREAKER INTERNAL CIRCUITS
-XDB91 CONNECTOR FOR OPENING RELEASE CIRCUITS OF SWITCH-DISCONNECTOR
B B
-XDB92 CONNECTOR FOR CLOSING RELEASE CIRCUITS OF SWITCH-DISCONNECTOR
-XDB93 CONNECTOR FOR POSITION SWITCHES OF SWITCH-DISCONNECTOR
-XDB94 CONNECTOR FOR ELECTROMECHANICAL LOCK ON CLOSING OPERATION OF LINE SWITCH
-XDB95 CONNECTOR FOR ELECTROMECHANICAL LOCK ON CLOSING OPERATION OF EARTHING SWITCH
-XDB96 CONNECTOR FOR UNDERVOLTAGE RELEASE CIRCUITS OF SWITCH-DISCONNECTOR
-XDB97 CONNECTOR FOR CIRCUITS OF THE CONTACTOR CONTROL UNIT OF THE MOTOR FOR THE ELECTRICAL OPERATION OF
SWITCH-DISCONNECTOR
-XDC CUSTOMER TERMINAL BLOCK
-XDC1 CUSTOMER TERMINAL BLOCK FOR AUXILIARY CIRCUITS OF CIRCUIT BREAKER
-XDC2 CUSTOMER TERMINAL BLOCK FOR AUXILIARY CIRCUITS OF SWITCH-DISCONNECTOR
C -XDC3 CUSTOMER TERMINAL BLOCK FOR AUXILIARY CIRCUITS OF PROTECTION RELAY AND MULTIFUNCTION C
UNIT
-XDC4 CUSTOMER TERMINAL BLOCK FOR AUXILIARY CIRCUITS OF VOLTAGE TRANSFORMERS
-XDC5 CUSTOMER TERMINAL BLOCK FOR AUXILIARY CONTACTS OF MINIATURE CIRCUIT-BREAKERS
-XDE TERMINAL BLOCK FOR AUXILIARY CIRCUITS OF EARTHING SWITCH -QCE
-XDH TERMINAL BLOCK FOR AUXILIARY CIRCUITS IN ALTERNATING CURRENT
-XDH1 TERMINAL BLOCK FOR CIRCUITS OF ELECTROMECHANICAL LOCK PREVENTING THE DOOR OPENING OPERATION
-XDI TERMINAL BLOCK FOR INTERCONNECTION (CONNECTION BETWEEN PANELS)
-XDI1 TERMINAL BLOCK FOR INTERCONNECTIONS OF CONTROL CIRCUITS
-XDI2 TERMINAL BLOCK FOR INTERCONNECTIONS OF CIRCUITS OF MOTOR FOR CIRCUIT-BREAKER SPRINGS CHARGING

D -XDI3 TERMINAL BLOCK FOR INTERCONNECTIONS OF CIRCUITS OF MOTOR FOR SWITCH-DISCONNECTOR ELECTRICAL D
OPERATION
-XDI4 TERMINAL BLOCK FOR INTERCONNECTIONS OF AUXILIARY CIRCUITS IN ALTERNATING CURRENT
-XDI6 TERMINAL BLOCK FOR INTERCONNECTIONS OF VOLTAGE CIRCUITS
-XDI7 TERMINAL BLOCK FOR INTERCONNECTIONS OF MOD-BUS CIRCUITS
-XDI8 TERMINAL BLOCK FOR INTERCONNECTIONS OF CURRENT CIRCUITS
-XDI9 TERMINAL BLOCK FOR INTERCONNECTIONS OF SPECIAL CIRCUITS
-XDM SEALABLE TERMINAL BLOCK FOR MEASUREMENT
-XDS SOCKET OUTLETS
-XDT TERMINAL BLOCK FOR POSITION CONTACTS OF TRUCK
-XDV TERMINAL BLOCK FOR CIRCUITS OF VOLTAGE TRANSFORMERS
E E
-XDV1 CONNECTOR FOR CIRCUITS OF VOLTAGE TRANSFORMERS ON PHASE L1
-XDV2 CONNECTOR FOR CIRCUITS OF VOLTAGE TRANSFORMERS ON PHASE L2
-XDV3 CONNECTOR FOR CIRCUITS OF VOLTAGE TRANSFORMERS ON PHASE L3
-XDV4 CONNECTOR FOR CIRCUITS OF FERRO-RESONANCE DUMPING RESISTOR
-XDX SUPPORT TERMINAL BLOCKS
-XE1 EARTHING TERMINAL BLOCK FOR L.V. COMPARTMENT, LEFT SIDE
-XE2 EARTHING TERMINAL BLOCK FOR L.V. COMPARTMENT, RIGHT SIDE
-XE5 EARTHING TERMINAL BLOCK FOR CABLE COMPARTMENT, VOLTAGE INDICATOR SIDE

F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved REFERENCE DESIGNATIONS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en A12 D01
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

AUXILIARY POWER SUPPLY SPRING CB HEATING ELEMENT LIGHTING


AUXILIARY POWER SUPPLY
CHARGING MOTOR IN CABLE COMPARTIMENT IN CABLE COMPARTIMENT

A A

-XDI2 1 -XDI2 2
230VAC
-XDI2 3 -XDI2 4

B B

-XDI4 1 -XDI4 2
230VAC
-XDI4 3 -XDI4 4

3 1
13 21

-FCM5 14 22

/Q04.4B
S202-C0,5 I> I>
C C
4 2

-XDB1 1

-XDB 1

D -QAB D
-FCM1

I> -XDH 1 -XDH 3

1
-BGS1
-QBM2
-XE6 2
L
-MAS
PE 1
-EB1 1 -XE5
M HEATER
N PE 1
E 45W AC230V -EA2 E
LAMP
E14 25W AC230V 2

-XDB 2
-XDH 2 -XDH 4

-XDB1 2

F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved DISTRIBUTION OF AUXILIARY CIRCUITS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02 &EFS
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en D01 G01
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

AUXILIARY POWER SUPPLY (UPS)

A A
-XDI1 1 -XDI1 2
48VDC
-XDI1 3 -XDI1 4

B B

3 1
13 21

-FCM2 14 22
/Q04.2B

/Q04.2B

S202-C3 I> I>


C C
4 2

-XDX 4 3 2 1 11 12 13 14

/ N06.1B / N05.1A / N05.1F / N06.1F / N08.1F

D D

E E

/M03.1A
/M03.1F

F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved DISTRIBUTION OF AUXILIARY CIRCUITS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02 &EFS
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en G01 M03
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

CIRCUIT BREAKER EMERGENCY


CIRCUIT BREAKER OPENING RELEASE CIRCUIT BREAKER CLOSING RELEASE
OPENING

A A
G01.2F/ /N07.1A
-XDX1 1

L R 2
-SFS
/N06.3B 1 3

-XDX1 2

B B
-X100 16 15 -X100 6
-AA -AA
-XDC1 1 -XDC1 3 -XDC1 5

-SFO 13 -SFC 13

14 PO3 PO1 14
-X100 17 -X100 7

-XDC1 2 -XDC1 4 -X100 18 -XDC1 6


-AA
-XDX1 4
C C
-XDC1 7

PO3
-X100 19

-XDC1 8

-XDX1 3
-X100 8
-AA

D D
PO2
-X100 9

-XDB1 9 -XDB1 7 -XDB1 10 -XDB1 12

-XDB 9 -XDB 7 -XDB 10 -XDB 12

-QAB

-BGB1
E E
-MBO1 -MBC

-XDB 8 -XDB 11 -XDB 13 -XDB 23

-XDB1 8 -XDB1 11 -XDB1 13 -XDB1 23

G01.2F/

F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved CONTROL CIRCUITS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02 &EFS
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en M03 N01
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN

F
E
B
A

D
C

Scale
-AA

Project no
REF 615

1
1

REF 615 : ANALOG INPUT BOARD


AMMETER SIGNAL PHASE L1 /S04.6A 7 1/5A
-X120

Based on

Customer
AMMETER SIGNAL PHASE L1 /S04.6B
I1
8 N

Project name
AMMETER SIGNAL PHASE L2 /S04.6B 9 1/5A
AMMETER SIGNAL PHASE L2 /S04.6B
I2
10 N
AMMETER SIGNAL PHASE L3 /S04.6B 11 1/5A
AMMETER SIGNAL PHASE L3 /S04.6B
I3
12 N
13 1/5A
Io

2
2

14 N

60/

Intermalt

Intermalt
-X130 9 210V
not in use
10 N
60/
VOLTAGE PHASE L1 /S02.8B 11 210V
VOLTAGE PHASE L2 /S02.8B
U1
12 N
60/
VOLTAGE PHASE L2 /S02.8B 13 210V
VOLTAGE PHASE L3 /S02.8B
U2
14 N
60/
VOLTAGE PHASE L3 /S02.8B 15 210V
VOLTAGE PHASE L1 /S02.8B
U3
16 N

3
3

60/
OPEN DELTA VOLTAGE SIGNAL /S02.8D 17 210V
OPEN DELTA VOLTAGE SIGNAL /S02.8D
Uo
18 N

Approved
Created on

Work order id
REF 615 : BINARY OTUPUT BOARD
1 /N05.3C DC POWER SUPPLY (+)
-X100
Uaux

INGLESE
LOMBONI

8160003065
2 /N05.3D DC POWER SUPPLY (-)

3 /Q06.1C INTERNAL RELAY FAULT (IRF)


IRF 4 /Q06.1B INTERNAL RELAY FAULT (IRF)

4
4

5 /Q06.2B INTERNAL RELAY FAULT (IRF)


PO1 6 /M03.4B CLOSING CIRCUIT BREAKER

7 /M03.4C CLOSING CIRCUIT BREAKER


PO2 8 /M03.4D

9 /M03.4D
REF615 : MULTIFUNCTION PROTECTION RELAY

10 /Q06.2C
SO1
/Q06.2B

Resp. (division/department)
11

2016-07-05
2016-07-05
12 /Q06.2B

ITABB PPMV PS-PMEL


13 /Q06.3B
SO2
14 /Q06.3C

TITLE

5
5

16 /M03.3B OPENING CIRCUIT BREAKER


PO3
17 /M03.3C OPENING CIRCUIT BREAKER

15 /M03.3B

19 /M03.3C OPENING CIRCUIT BREAKER


TCS1 18 /M03.3C OPENING CIRCUIT BREAKER

20 /Q06.4B
/Q06.4C

Document kind
22
PO4 21 /Q06.4B

23 /Q06.4C

TCS2 24 /Q06.4D

6
6

CONTROL CIRCUITS

14 -X110 /Q06.6C
Circuit Diagram

SO1 16 /Q06.6B

15 /Q06.6B

17 /Q06.7C
SO2 19 /Q06.7B

18 /Q06.7B

20 /Q06.7C
SO3 22 /Q06.7B TRIP LOCKOUT RELAY (86)
7
7

21 /Q06.7B
Document id
External doc. id

23 /Q06.8B
Ref. designation

SO4
24 /Q06.8C
1VCE014869T0100
H01, H02

A
Revision
Lang

en
8
8

Page

N01
REF 615

Cont
DCC

N02
&EFS
F
E
B
A

D
C
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN

F
E
B
A

D
C

Scale
-AA

Project no
REF 615

1
1

REF 615 : BINARY INPUT BOARD


AVAILABLE /N06.1D -X110 1
BI1
DC (-) /N06.1E 2

Based on

Customer
AVAILABLE /N06.2D 3

Project name
BI2
DC (-) /N06.2E 4
AVAILABLE /N06.3D 5
BI3
DC (-) /N06.3E 6

BI4
CIRCUIT BREAKER SPRING CHARGED /N06.4D 7

2
2

SWITCH DISCONNECTOR IN LINE POSITION CLOSED /N06.5D 8


BI5
DC (-) /N06.5E 9

Intermalt

Intermalt
BI6
SWITCH DISCONNECTOR IN LINE POSITION OPEN /N06.6D 10
SWITCH DISCONNECTOR IN EARTH POSITION CLOSED /N06.7D 11
BI7
DC (-) /N06.7E 12

BI8
SWITCH DISCONNECTOR IN EARTH POSITION OPEN /N06.8D 13

AVAILABLE /N07.1D

3
3

-X120 1
DC (-) /N07.1E
BI1
2
CIRCUIT BREAKER CLOSED /N07.2D 3 BI2

Approved
Created on

Work order id
CIRCUIT BREAKER OPEN /N07.3D 4 BI3
AVAILABLE /N07.4D 5
BI4

INGLESE
LOMBONI

8160003065
DC (-) /N07.4E 6

AVAILABLE /N08.1D 1
-X130

4
4

DC (-) /N08.1E
BI1
2
AVAILABLE /N08.2D 3
BI2
DC (-) /N08.2E 4
AVAILABLE /N08.3D 5
BI3
REF615 : MULTIFUNCTION PROTECTION RELAY

DC (-) /N08.3E 6
AVAILABLE /N08.4D 7

Resp. (division/department)
BI4
DC (-) /N08.4E 8

2016-07-05
2016-07-05

ITABB PPMV PS-PMEL


TITLE

5
5

Document kind

6
6

CONTROL CIRCUITS

Circuit Diagram
7
7

Document id
External doc. id

Ref. designation

1VCE014869T0100
H01, H02

A
Revision
Lang

en
8
8

Page

N02
REF 615

Cont
DCC

N05
&EFS
F
E
B
A

D
C
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

MULTIMETER NEMO 96HD+


REF 615 : POWER SUPPLY
POWER SUPPLY 48VDC

A A
G01.2D/ /N06.1A

B B

20
-PGM
96x96
Power Supply
C GND -X100 1 11-60 VDC C
-AA

+
U
-

-X100 2

21
D D

E E

G01.2D/ /N06.1E

F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved CONTROL CIRCUITS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02 &EFS
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en N05 N06
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

BINARY INPUTS REF615

SELECTOR SWITCH CIRCUIT BREAKER SPRINGS SWITCH DISCONNECTOR IN LINE SWITCH DISCONNECTOR IN LINE SWITCH DISCONNECTOR IN SWITCH DISCONNECTOR IN
AVAILABLE AVAILABLE
REMOTE POSITION CHARGED POSITION CLOSED POSITION OPEN EARTH POSITION CLOSED EARTH POSITION OPEN
A A

N05.8A/

G01.1D / /N07.1B

B -XDC3 11 -XDC3 13 -XDB1 3


B

-XDB 3 -XDB93 5 -XDB93 17


6
L R
-QAB -QBS
-SFS
/M03.2B 5 7
-BGS2 -BGI412 -BGI432
/S01.4B /S01.7B
LINE EARTH

-XDC3 12 -XDC3 14

-XDB 4 -XDB93 4 6 -XDB93 16 18


C C

-XDB1 4

D D

-X110 1 3 5 7 8 10 11 13
-AA
+

+
- - - - - - - -

REF 615 BI1 BI2 BI3 BI4 BI5 BI6 BI7 BI8

-X110 2 4 6 9 12
E E

N05.8F /

G01.3D / /N07.1F

F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved CONTROL CIRCUITS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02 &EFS
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en N06 N07
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

BINARY INPUTS REF615

CIRCUIT BREAKER CIRCUIT BREAKER


CIRCUIT BREAKER CLOSED CIRCUIT BREAKER OPEN
REMOTE CLOSING REMOTE OPENING
A A

M03.8A/

N06.8B/ /N08.1B

B -XDC3 23
-XDB1 37 -XDB1 39 -XDC3 25 B

-XDB 37 -XDB 39

-QAB

-BGB1 -BGB1
/S01.4C /S01.4C

-XDC3 24 -XDC3 26

-XDB 38 -XDB 40
C C

-XDB1 38 -XDB1 40

D D

-X120 1 3 4 5
-AA
+

- - - -

REF 615 BI1 BI2 BI3 BI4

-X120 2 6
E E

N06.8F/

F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved CONTROL CIRCUITS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02 &EFS
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en N07 N08
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

BINARY INPUTS REF615

AVAILABLE AVAILABLE MCB VT'S OK


A A

N07.8B/

B -XDC3 27 -XDC3 29 B

13 13
-FCM7 -FCM6
/S02.6B 14 /S02.6D 14

-XDC3 28 -XDC3 30

C C

D D

-X130 1 3 5 7
-AA
+

- - - -

REF 615 BI1 BI2 BI3 BI4

-X130 2 4 6 8
E E

G01.3D/

F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved CONTROL CIRCUITS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02 &EFS
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en N08 Q02
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

SWITCH-DISCONNECTOR SWITCH-DISCONNECTOR SWITCH-DISCONNECTOR SWITCH-DISCONNECTOR


IN LINE POSITION IN LINE POSITION IN EARTH POSITION IN EARTH POSITION

A OPEN CLOSED OPEN CLOSED OPEN CLOSED OPEN CLOSED A

-XDC2 9 7 12 10 -XDC2 21 19 24 22

B B

-XDB93 3 1 -XDB93 9 7 -XDB93 12 10 -XDB93 15 13 -XDB93 21 19 -XDB93 24 22

-QBS

-BGI411 -BGI413 -BGI414 -BGI431 -BGI433 -BGI434


/S01.4B /S01.5B /S01.5B /S01.6B /S01.7B /S01.8B
LINE LINE LINE EARTH EARTH EARTH

C -XDB93 2 -XDB93 8 -XDB93 11 -XDB93 14 -XDB93 20 -XDB93 23 C

-XDC2 8 -XDC2 11 -XDC2 20 -XDC2 23

D D

E E

F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved AVAILABLE CONTACTS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02 &EFS
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en Q02 Q04
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

AUXILIARY CONTACTS OF MINIATURE CIRCUIT BREAKER

A A

-XDC5 1 3 9 11 13

B B

13 21 21 21 21
-FCM2 -FCM2 -FCM5 -FCM7 -FCM6
/G01.2C 14 /G01.2C 22 /D01.6C 22 /S02.6B 22 /S02.6D 22

C C

-XDC5 2 4 10 12 14

D D

E E

F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved AVAILABLE CONTACTS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02 &EFS
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en Q04 Q05
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

MCB SPRING CHARGING MOTOR


CIRCUIT BREAKER AUXILIARY CONTACTS CIRCUIT BREAKER AUXILIARY CONTACTS
OPEN

A A

-XDC1 21 35 -XDC1 41 43 -XDC1 45 47 -XDC1 51

B B
-XDB1 21 -XDB1 35 -XDB1 5 -XDB1 14

-XDB 21 -XDB 35 -XDB 41 -XDB 43 -XDB 45 -XDB 47 -XDB 5 -XDB 14

-QAB -QAB -QAB

-BGB1 -BGB1 -BGB2 -BGB2 -BGB2 -BGB2 -FCM1


/S01.4C /S01.4C /S01.5C /S01.5C /S01.5C /S01.6C /D01.3D

C -XDB 22 -XDB 36 -XDB 42 -XDB 44 -XDB 46 -XDB 48 -XDB 6 -XDB 15 C

-XDB1 22 -XDB1 36 -XDB1 6 -XDB1 15

-XDC1 22 36 -XDC1 42 44 -XDC1 46 48 -XDC1 52

D D

E E

F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved AVAILABLE CONTACTS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02 &EFS
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en Q05 Q06
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

BINARY OUTPUT REF615 AUXILIARY CONTACTS AVAILABLE BINARY OUTPUT REF615 AUXILIARY CONTACTS AVAILABLE

TRIP LOCKOUT TRIP VOLTAGE


INTERNAL RELAY FAULT (IRF) O/C TRIP E/F TRIP AVAILABLE TRIP 59G CUMULATIVE ALARM
RELAY (86) PROTECTION (27/59)
A A

-XDC3 1 -XDC3 3 -XDC3 5 -XDC3 9 -XDC3 15 -XDC3 17 -XDC3 19 -XDC3 21

B B

-X100 4 5 -X100 11 12 -X100 13 -X100 21 20 -X110 16 15 -X110 19 18 -X110 22 21 -X110 23


-AA -AA -AA -AA -AA -AA -AA -AA

IRF SO1 SO2 PO4 SO1 SO2 SO3 SO4


-X100 3 -X100 10 -X100 14 -X100 22 -X110 14 -X110 17 -X110 20 -X110 24

C C
-X100 23
-AA

PO4
-X100 24

D D
-XDC3 2 -XDC3 4 -XDC3 6 -XDC3 10 -XDC3 16 -XDC3 18 -XDC3 20 -XDC3 22

E E

F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved AVAILABLE CONTACTS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02 &EFS
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en Q06 S01
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

3 AC 11kV 50Hz, 1250A, 20kA for 3Sec


L1
A L2 A
L3

-QBS

-BGI411 -BGI412 -BGI413 -BGI414 -BGI431 -BGI432 -BGI433 -BGI434


B LINE LINE LINE LINE EARTH EARTH EARTH EARTH B

/Q02.1C

/N06.5C

/Q02.3C

/Q02.4C

/Q02.5C

/N06.7C

/Q02.7C

/Q02.8C
-QAB

C C
M -BGB1 -BGB2
-QAB

/N07.2C

/Q05.2C

/N07.3C

/Q05.1C

/Q05.4C

/Q05.3C

/Q05.4C

/Q05.5C
D D

-QCE

E E

L1 L2 L3
S02.1A /

S02.2A /

S02.2A /

F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved MAIN CIRCUITS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02 &EFS
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en S01 S02
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

/ S01.1E

/ S01.2E

/ S01.2E
A A
L1 L2 L3

-AA
-FCM7
S203-C2 -XDI6 7 27
8
59
5 6 5 -X130 16

I>
B 6 -X130 15 U3 59N B
3 4 3 -X130 14

I>
-BAT1 -XDV1 4 -X130 13 U2
a 1 -XDV 1 1 2 1 -X130 12

I>
A n 2 2 2 -X130 11 U1
N da 3
dn 4
Un / S04.5C
13 14 /N08.3B U3 / S04.5C

VOLTAGE METERING INPUTS


21 22 /Q04.5B
U2 / S04.5C
-BAT2 -XDV2 U1 / S04.5C
a 1 3
A n 2 4
C N da 3 C
dn 4

-BAT3 -XDV3
a 1 5
A n 2 6
N da 3
dn 4 7

3
-XE2

D -FCM6 -XDI6 12 D
S201-C2 11 -X130 18

-XDV Uo
8 1 2 9 -X130 17

I>
10
-XDV4
9 1
10
11 x1 13 14 /N08.4B
21 22 /Q04.6B
12 -RAA
13 x2
-XDV4
14 2
E 15
E
L1 L2 L3
4
-XE2
S03.1A /

S03.2A /

S03.2A /

F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved MAIN CIRCUITS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02 &EFS
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en S02 S03
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

/ S02.1E

/ S02.2E

/ S02.2E
A A

B B

C -PFV1 C
L1
-BAD1 1
-XE5
L2 PE 1
-BAD2 1

L3
-BAD3 1

D D

E E
L1 L2 L3
S04.1A /

S04.2A /

S04.2A /

F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved MAIN CIRCUITS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02 &EFS
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en S03 S04
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

/ S03.1E

/ S03.2E

/ S03.2E
A A
-AA
P1 P1 P1 -XDA1

CURRENT METERING INPUTS


1s1 1 -XDA 1 -X120 7 50
-BCT1 1s2 2 2
I1 51
-X120 8
-XDA2 51N
1s1 1 3 67N
-BCT2 1s2 2 4
-X120 9
-XDA3
1s1 1 I2
5 -X120 10
B B
-BCT3 1s2 2 6
7

1 -X120 11
-XE2 I3
-X120 12

-PGM
IME
-XDA1 NEMO 96HD+
2s1 3 -XDA 8
1
C -BCT1 2s2 4 9
3
IL1 U1 2 U1 / S02.7C C
-XDA2 U2 5 U2 / S02.7C
2s1 3 10
4 U3 8 U3 / S02.7C
-BCT2 2s2 4 11
6
IL2
Un 11 Un / S02.7C
-XDA3
2s1 3 12
7
-BCT3 2s2 4 13
9
IL3
14
2
P2 P2 P2
-XE2

D D

E E

F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved MAIN CIRCUITS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02 &EFS
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en S04 X01
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

A A

B B

C C
&CD/S04.3A

&CD/S04.3B

&CD/S04.3B

&CD/S04.3B

&CD/S04.3B

&CD/S04.3B

&CD/S04.3B

&CD/S04.3C

&CD/S04.3C

&CD/S04.3C

&CD/S04.3C

&CD/S04.3C

&CD/S04.3D

D &CD/S04.3D D
-XDA

10

11

12

13

14
1

E E

NOTE : "&CD MEANS THAT REFERENCE IS RELEVANT TO CIRCUIT DIAGRAM"


F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved TERMINAL BLOCKS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en X01 X02
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN

F
E
B
A

D
C

Scale

Project no

1
1

-XDB1

Based on

Customer

Project name
1 &CD/D01.3D

2 &CD/D01.3E

3 &CD/N06.4B

2
2

4 &CD/N06.4C

Intermalt

Intermalt
5 &CD/Q05.6B

6 &CD/Q05.6C

7 &CD/M03.3D

8 &CD/M03.3F

9 &CD/M03.2D

3
3

10 &CD/M03.4D

Approved
11 &CD/M03.4F

Created on

Work order id
NOTE : "&CD MEANS THAT REFERENCE IS RELEVANT TO CIRCUIT DIAGRAM"
12 &CD/M03.6D

13 &CD/M03.6F

INGLESE
LOMBONI

8160003065
14 &CD/Q05.7B

15 &CD/Q05.7C

4
4

21 &CD/Q05.1B

22 &CD/Q05.1C

23 &CD/M03.7F

35 &CD/Q05.2B

Resp. (division/department)
2016-07-05
2016-07-05

ITABB PPMV PS-PMEL


36 &CD/Q05.2C

37 &CD/N07.2B

TITLE

5
5

38 &CD/N07.2C

39 &CD/N07.3B

40 &CD/N07.3C

Document kind

6
6

TERMINAL BLOCKS

Circuit Diagram
7
7

Document id
External doc. id

Ref. designation

1VCE014869T0100
H01, H02

A
Revision
Lang

en
8
8

Page

X02
Cont
DCC

X03
F
E
B
A

D
C
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN

F
E
B
A

D
C

Scale

Project no

1
1

-XDC1

Based on

Customer

Project name
1 &CD/M03.1B

2 &CD/M03.1C

3 &CD/M03.2B CIRCUIT BREAKER EMERGENCY OPENING

2
2

4 &CD/M03.2C CIRCUIT BREAKER EMERGENCY OPENING

Intermalt

Intermalt
5 &CD/M03.5B CIRCUIT BREAKER CLOSING RELEASE

6 &CD/M03.5C CIRCUIT BREAKER CLOSING RELEASE

7 &CD/M03.4C CIRCUIT BREAKER CLOSING RELEASE

8 &CD/M03.4C CIRCUIT BREAKER CLOSING RELEASE

21 &CD/Q05.1B CIRCUIT BREAKER AUXILIARY CONTACTS

3
3

22 &CD/Q05.1D CIRCUIT BREAKER AUXILIARY CONTACTS

Approved
35 &CD/Q05.2B CIRCUIT BREAKER AUXILIARY CONTACTS

Created on

Work order id
NOTE : "&CD MEANS THAT REFERENCE IS RELEVANT TO CIRCUIT DIAGRAM"
36 &CD/Q05.2D CIRCUIT BREAKER AUXILIARY CONTACTS

41 &CD/Q05.3B CIRCUIT BREAKER AUXILIARY CONTACTS

INGLESE
LOMBONI

8160003065
42 &CD/Q05.3D CIRCUIT BREAKER AUXILIARY CONTACTS

43 &CD/Q05.4B CIRCUIT BREAKER AUXILIARY CONTACTS

4
4

44 &CD/Q05.4D CIRCUIT BREAKER AUXILIARY CONTACTS

45 &CD/Q05.4B CIRCUIT BREAKER AUXILIARY CONTACTS

46 &CD/Q05.4D CIRCUIT BREAKER AUXILIARY CONTACTS

47 &CD/Q05.5B CIRCUIT BREAKER AUXILIARY CONTACTS

Resp. (division/department)
2016-07-05
2016-07-05

ITABB PPMV PS-PMEL


48 &CD/Q05.5D CIRCUIT BREAKER AUXILIARY CONTACTS

51 &CD/Q05.6B MCB SPRING CHARGING MOTOR OPEN

TITLE

5
5

52 &CD/Q05.6D MCB SPRING CHARGING MOTOR OPEN

Document kind

6
6

TERMINAL BLOCKS

Circuit Diagram
7
7

Document id
External doc. id

Ref. designation

1VCE014869T0100
H01, H02

A
Revision
Lang

en
8
8

Page

X03
Cont
DCC

X04
F
E
B
A

D
C
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN

F
E
B
A

D
C

Scale

Project no

1
1

-XDC2

Based on

Customer

Project name
7 &CD/Q02.3B SWITCH-DISCONNECTOR IN LINE POSITION CLOSED

8 &CD/Q02.3D SWITCH-DISCONNECTOR IN LINE POSITION OPEN

9 &CD/Q02.3B SWITCH-DISCONNECTOR IN LINE POSITION OPEN

2
2

10 &CD/Q02.4B SWITCH-DISCONNECTOR IN LINE POSITION CLOSED

Intermalt

Intermalt
11 &CD/Q02.4D SWITCH-DISCONNECTOR IN LINE POSITION OPEN

12 &CD/Q02.4B SWITCH-DISCONNECTOR IN LINE POSITION OPEN

19 &CD/Q02.7B SWITCH-DISCONNECTOR IN EARTH POSITION CLOSED

20 &CD/Q02.7D SWITCH-DISCONNECTOR IN EARTH POSITION OPEN

21 &CD/Q02.7B SWITCH-DISCONNECTOR IN EARTH POSITION OPEN

3
3

22 &CD/Q02.8B SWITCH-DISCONNECTOR IN EARTH POSITION CLOSED

Approved
23 &CD/Q02.8D SWITCH-DISCONNECTOR IN EARTH POSITION OPEN

Created on

Work order id
NOTE : "&CD MEANS THAT REFERENCE IS RELEVANT TO CIRCUIT DIAGRAM"
24 &CD/Q02.8B SWITCH-DISCONNECTOR IN EARTH POSITION OPEN

INGLESE
LOMBONI

8160003065
4
4

Resp. (division/department)
2016-07-05
2016-07-05

ITABB PPMV PS-PMEL


TITLE

5
5

Document kind

6
6

TERMINAL BLOCKS

Circuit Diagram
7
7

Document id
External doc. id

Ref. designation

1VCE014869T0100
H01, H02

A
Revision
Lang

en
8
8

Page

X04
Cont
DCC

X05
F
E
B
A

D
C
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN

F
E
B
A

D
C

Scale

Project no

1
1

-XDC3

Based on

Customer

Project name
1 &CD/Q06.1B BINARY OUTPUT REF615 AUXILIARY CONTACTS AVAILABLE INTERNAL RELAY FAULT (IRF)

2 &CD/Q06.1D BINARY OUTPUT REF615 AUXILIARY CONTACTS AVAILABLE INTERNAL RELAY FAULT (IRF)

3 &CD/Q06.2B BINARY OUTPUT REF615 AUXILIARY CONTACTS AVAILABLE O/C TRIP

2
2

4 &CD/Q06.2D BINARY OUTPUT REF615 AUXILIARY CONTACTS AVAILABLE O/C TRIP

Intermalt

Intermalt
5 &CD/Q06.3B BINARY OUTPUT REF615 AUXILIARY CONTACTS AVAILABLE E/F TRIP

6 &CD/Q06.3D BINARY OUTPUT REF615 AUXILIARY CONTACTS AVAILABLE E/F TRIP

9 &CD/Q06.4B BINARY OUTPUT REF615 AUXILIARY CONTACTS AVAILABLE AVAILABLE

10 &CD/Q06.4D BINARY OUTPUT REF615 AUXILIARY CONTACTS AVAILABLE AVAILABLE

11 &CD/N06.1B BINARY INPUTS REF615 AVAILABLE

3
3

12 &CD/N06.1C BINARY INPUTS REF615 AVAILABLE

Approved
13 &CD/N06.2B BINARY INPUTS REF615 AVAILABLE

Created on

Work order id
NOTE : "&CD MEANS THAT REFERENCE IS RELEVANT TO CIRCUIT DIAGRAM"
14 &CD/N06.2C BINARY INPUTS REF615 AVAILABLE

15 &CD/Q06.6B BINARY OUTPUT REF615 AUXILIARY CONTACTS AVAILABLE TRIP 59G

INGLESE
LOMBONI

8160003065
16 &CD/Q06.6D BINARY OUTPUT REF615 AUXILIARY CONTACTS AVAILABLE TRIP 59G

17 &CD/Q06.7B BINARY OUTPUT REF615 AUXILIARY CONTACTS AVAILABLE CUMULATIVE ALARM

4
4

18 &CD/Q06.7D BINARY OUTPUT REF615 AUXILIARY CONTACTS AVAILABLE CUMULATIVE ALARM

19 &CD/Q06.7B BINARY OUTPUT REF615 AUXILIARY CONTACTS AVAILABLE TRIP LOCKOUT RELAY (86)

20 &CD/Q06.7D BINARY OUTPUT REF615 AUXILIARY CONTACTS AVAILABLE TRIP LOCKOUT RELAY (86)

21 &CD/Q06.8B BINARY OUTPUT REF615 AUXILIARY CONTACTS AVAILABLE TRIP VOLTAGE PROTECTION (27/59)

Resp. (division/department)
2016-07-05
2016-07-05

ITABB PPMV PS-PMEL


22 &CD/Q06.8D BINARY OUTPUT REF615 AUXILIARY CONTACTS AVAILABLE TRIP VOLTAGE PROTECTION (27/59)

23 &CD/N07.1B BINARY INPUTS REF615 CIRCUIT BREAKER REMOTE CLOSING

TITLE

5
5

24 &CD/N07.1C BINARY INPUTS REF615 CIRCUIT BREAKER REMOTE CLOSING

25 &CD/N07.4B BINARY INPUTS REF615 CIRCUIT BREAKER REMOTE OPENING

26 &CD/N07.4C BINARY INPUTS REF615 CIRCUIT BREAKER REMOTE OPENING

27 &CD/N08.1B BINARY INPUTS REF615 AVAILABLE

Document kind
28 &CD/N08.1C BINARY INPUTS REF615 AVAILABLE

29 &CD/N08.2B BINARY INPUTS REF615 AVAILABLE

6
6

30 &CD/N08.2C BINARY INPUTS REF615 AVAILABLE


TERMINAL BLOCKS

Circuit Diagram
7
7

Document id
External doc. id

Ref. designation

1VCE014869T0100
H01, H02

A
Revision
Lang

en
8
8

Page

X05
Cont
DCC

X06
F
E
B
A

D
C
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN

F
E
B
A

D
C

Scale

Project no

1
1

-XDC5

Based on

Customer

Project name
1 &CD/Q04.2B AUXILIARY CONTACTS OF MINIATURE CIRCUIT BREAKER

2 &CD/Q04.2C AUXILIARY CONTACTS OF MINIATURE CIRCUIT BREAKER

3 &CD/Q04.2B AUXILIARY CONTACTS OF MINIATURE CIRCUIT BREAKER

2
2

4 &CD/Q04.2C AUXILIARY CONTACTS OF MINIATURE CIRCUIT BREAKER

Intermalt

Intermalt
9 &CD/Q04.4B AUXILIARY CONTACTS OF MINIATURE CIRCUIT BREAKER

10 &CD/Q04.4C AUXILIARY CONTACTS OF MINIATURE CIRCUIT BREAKER

11 &CD/Q04.5B AUXILIARY CONTACTS OF MINIATURE CIRCUIT BREAKER

12 &CD/Q04.5C AUXILIARY CONTACTS OF MINIATURE CIRCUIT BREAKER

13 &CD/Q04.6B AUXILIARY CONTACTS OF MINIATURE CIRCUIT BREAKER

3
3

14 &CD/Q04.6C AUXILIARY CONTACTS OF MINIATURE CIRCUIT BREAKER

Approved
Created on

Work order id
NOTE : "&CD MEANS THAT REFERENCE IS RELEVANT TO CIRCUIT DIAGRAM"
INGLESE
LOMBONI

8160003065
4
4

Resp. (division/department)
2016-07-05
2016-07-05

ITABB PPMV PS-PMEL


TITLE

5
5

Document kind

6
6

TERMINAL BLOCKS

Circuit Diagram
7
7

Document id
External doc. id

Ref. designation

1VCE014869T0100
H01, H02

A
Revision
Lang

en
8
8

Page

X06
Cont
DCC

X07
F
E
B
A

D
C
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

A A

B B

C C
&CD/G01.2A

&CD/G01.8A

&CD/G01.2A

&CD/G01.8A

D D
-XDI1

E E

NOTE : "&CD MEANS THAT REFERENCE IS RELEVANT TO CIRCUIT DIAGRAM"


F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved TERMINAL BLOCKS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en X07 X08
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

A A

B B

C C
&CD/D01.2B

&CD/D01.8B

&CD/D01.2B

&CD/D01.8B

D D
-XDI2

E E

NOTE : "&CD MEANS THAT REFERENCE IS RELEVANT TO CIRCUIT DIAGRAM"


F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved TERMINAL BLOCKS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en X08 X09
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

A A

B B

C C
&CD/D01.2B

&CD/D01.8B

&CD/D01.2B

&CD/D01.8B

D D
-XDI4

E E

NOTE : "&CD MEANS THAT REFERENCE IS RELEVANT TO CIRCUIT DIAGRAM"


F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved TERMINAL BLOCKS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en X09 X10
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

A A

B B

C C
&CD/S02.7B

&CD/S02.7B

&CD/S02.7B

&CD/S02.7B

&CD/S02.7B

&CD/S02.7B

&CD/S02.7B

&CD/S02.7B

&CD/S02.7D

&CD/S02.7D

&CD/S02.7D

&CD/S02.7D

D D
-XDI6

10

11

12
1

E E

NOTE : "&CD MEANS THAT REFERENCE IS RELEVANT TO CIRCUIT DIAGRAM"


F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved TERMINAL BLOCKS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en X10 X11
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

A A

B B

C C
&CD/S02.5B

&CD/S02.5B

&CD/S02.5E

&CD/S02.5E

&CD/S02.5E

&CD/S02.5E

&CD/S02.5E

&CD/S02.5E
&CD/S02.5C

&CD/S02.5C

&CD/S02.5C

&CD/S02.5D

&CD/S02.5D

&CD/S02.5D

&CD/S02.5D

D D
-XDV

10

11

12

13

14

15
1

E E

NOTE : "&CD MEANS THAT REFERENCE IS RELEVANT TO CIRCUIT DIAGRAM"


F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved TERMINAL BLOCKS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en X11 X12
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

A A

B B

C C
&CD/G01.2C

&CD/G01.2C

&CD/G01.1C

&CD/G01.1C

&CD/G01.2C

&CD/G01.2C

&CD/G01.3C

&CD/G01.3C

D D
-XDX

11

12

13

14
1

E E

NOTE : "&CD MEANS THAT REFERENCE IS RELEVANT TO CIRCUIT DIAGRAM"


F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved TERMINAL BLOCKS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en X12 X13
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

A A

B B

C C
&CD/M03.1A

&CD/M03.3B

&CD/M03.3D

&CD/M03.4C

D D
-XDX1

E E

NOTE : "&CD MEANS THAT REFERENCE IS RELEVANT TO CIRCUIT DIAGRAM"


F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved TERMINAL BLOCKS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en X13 Z01
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

PART LIST
A A
DESIGNATION CLASS CHARACTERISTICS CODE MANUFACTURED CODE QUANTITY SUPPLIER
ORDER NUMBER

-AA Protection devices FEEDER PROTECTION AND CONTROL UNIT TYPE REF615 HBFFAEAGNNA1ANA11 REF615-F 1 ABB
CONFIGURATION F G

-EA2 Light LAMP E14 - 25W 3WCA023432P0001 77.225.3104.10 1 BJB


BJB GmbH

-EB1 Heating HEATER 45W AC230V 3WCA007125P0001 14003.0-00 1 STEGO


B B
-FCM2 Protection devices MCB S202-C3 3WCA022097P0105 2CDS252001R0034 1 ABB

-FCM2 Protection devices AUX. CONTACT S2C-H11L 3WCA022097P0013 2CDS200936R0001 1 ABB


FOR MCB SERIES S200

-FCM5 Protection devices MCB S202-C0,5 3WCA022097P0101 2CDS252001R0984 1 ABB

-FCM5 Protection devices AUX. CONTACT S2C-H11L 3WCA022097P0013 2CDS200936R0001 1 ABB


FOR MCB SERIES S200

-FCM6 Protection devices MCB S201-C2 3WCA022097P0121 2CDS251001R0024 1 ABB


C C
-FCM6 Protection devices AUX. CONTACT S2C-H11L 3WCA022097P0013 2CDS200936R0001 1 ABB
FOR MCB SERIES S200

-FCM7 Protection devices MCB S203-C2 3WCA022097P0131 2CDS253001R0024 1 ABB

-FCM7 Protection devices AUX. CONTACT S2C-H11L 3WCA022097P0013 2CDS200936R0001 1 ABB


FOR MCB SERIES S200

-PFV1 Signal devices VPIS ABB 43911082 3WDA020579P0001 43911082 1 ELECTRONSYST. MD

-PGM Measuring instruments, NETWORK MONITOR MULTIMETERING 3WYR000348 MF96022 2 IME


test devices Power Supply 11...60 VDC - cl.0.5
D D
-SFC Sensor, switch, and PUSHBUTTON CP1-10W-10 3WDA008620P0002 1SFA619100R1015 1 ABB
pushbutton

-SFO Sensor, switch, and PUSHBUTTON CP1-10B-10 3WDA008620P0001 1SFA619100R1016 1 ABB


pushbutton

-SFS Sensor, switch, and LOC/REM SWITCH CA10 A221-600+FT2+F9FA514 3WDA014364P0001 CA10 A221-600+FT2+F9FA 2 KRAUS NAIMER
pushbutton 514

-XDA Terminals TERMINAL M6/8.ST1.IP20 3WCA022254P0001 EN011597110 14 ABB

E -XDB1 Terminals TERMINAL D2,5/8.ADO 3WCA022099P0002 EN019905906 2 ABB E


-XDB1 Terminals TERMINAL D1/5.ADO 3WCA022099P0001 EN019956324 22 ABB

-XDC1 Terminals TERMINAL D2,5/5.ADO 3WCA022102P0001 EN019955423 22 ABB

-XDC2 Terminals TERMINAL D2,5/5.ADO 3WCA022102P0001 EN019955423 12 ABB

-XDC3 Terminals TERMINAL D2,5/5.ADO 3WCA022102P0001 EN019955423 28 ABB

F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved PARTS LIST Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en Z01 Z02
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

PART LIST
A A
DESIGNATION CLASS CHARACTERISTICS CODE MANUFACTURED CODE QUANTITY SUPPLIER
ORDER NUMBER

-XDC5 Terminals TERMINAL D2,5/5.ADO 3WCA022102P0001 EN019955423 10 ABB

-XDI1 Terminals TERMINAL D6/8.ADO.1 3WDA025414P0003 EN019904621 4 ABB

-XDI2 Terminals TERMINAL D6/8.ADO.1 3WDA025414P0003 EN019904621 4 ABB

-XDI4 Terminals TERMINAL D6/8.ADO.1 3WDA025414P0003 EN019904621 4 ABB


B B
-XDI6 Terminals TERMINAL D6/8.ADO.1 3WDA025414P0003 EN019904621 12 ABB

-XDV Terminals TERMINAL M6/8.ST1.IP20 3WCA022254P0001 EN011597110 15 ABB

-XDX1 Terminals TERMINAL D1/5.ADO.1 3WDA025413P0001 1SNA199563R2400 4 ABB

-XDX Terminals TERMINAL D1/5.ADO.1 3WDA025413P0001 1SNA199563R2400 8 ABB

C C

D D

E E

F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved PARTS LIST Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en Z02 Z10
1 2 3 4 5 6 7 8
WE RESERVE ALL RIGHTS IN THIS DOCUMENT AND IN THE INFORMATION CONTAINED THEREIN. REPRODUCTION, USE OR DISCLOSURE TO THIRD PARTIES WITHOUT EXPESS AUTHORITY IS STRICTLY FORBIDDEN
1 2 3 4 5 6 7 8

MV Main List 1
M.V. CIRCUIT-BREAKER
A A
DESIGNATION CLASS CHARACTERISTICS QUANTITY PAGE

-QAB CIRCUIT-BREAKER TYPE: VD4/R-Sec 12kV 630A 20kA CIRCUIT DIAGRAM :1VCD400118 /S01.1C

-BGB2 (FIG.32) CIRCUIT-BREAKER AVAILABLE AUXILIARY CONTACTS (-BGB1,-BGB2)

-BGS2 (FIG.22) CONTACT SIGNALLING CLOSING SPRINGS CHARGED

-FCM1 (FIG.27);(FIG.21) CONTACT SIGNALLING MINIATURE BREAKER FOR PROTECTION OF THE SPRING-CHARGING
B MOTOR OFF;MINIATURE BREAKER WITH THERMOMAGNETIC O/C RELEASE FOR THE B
SPRING-CHARGING MOTOR PROTECTION

-MAS (FIG.01) SPRING CHARGING-MOTOR CIRCUIT

-MBC (FIG.02) SHUNT CLOSING RELEASE

-MBO1 (FIG.07) FIRST SHUNT OPENING RELEASE CIRCUIT


MV Main List 1
M.V. DEVICES
DESIGNATION CLASS CHARACTERISTICS QUANTITY PAGE
C C

-BAT1 Voltage Transformer 11/V3kV 0,11/V3kV 50VA-cl.0.5/3P 0,11/3kV 50VA-cl.3P 1 /S02.3B

-BAT2 Voltage Transformer 11/V3kV 0,11/V3kV 50VA-cl.0.5/3P 0,11/3kV 50VA-cl.3P 1 /S02.3C

-BAT3 Voltage Transformer 11/V3kV 0,11/V3kV 50VA-cl.0.5/3P 0,11/3kV 50VA-cl.3P 1 /S02.3D

-BCT1 Current Transformer 300A/5A/5A 5VA - CL. 0.5 5VA - CL. 5P10 1 /S04.1A

-BCT2 Current Transformer 300A/5A/5A 5VA - CL. 0.5 5VA - CL. 5P10 1 /S04.2B

D -BCT3 Current Transformer 300A/5A/5A 5VA - CL. 0.5 5VA - CL. 5P10 1 /S04.2B D

-QBS Switch-Disconnector THREE POSITION SWITCH-DISCONNECTOR TYPE Gsec 1 /S01.1A

-QCE Earthing switch type ES EARTHING SWITCH TYPE ES 230 1 /S01.1D


230

-RAA Antiferroresonance ANTIFERRORESONANCE PROTECTION UNIT 600W 22ohm 1 /S02.5E


Resistor

E E

F F
Scale Based on Created on INGLESE 2016-07-05 TITLE External doc. id

Customer Approved MV DEVICES CHARACTERISTICS Ref. designation DCC


Intermalt LOMBONI 2016-07-05 H01, H02
Project no Project name Work order id Resp. (division/department) Document kind Document id Revision Lang Page Cont
Intermalt 8160003065 ITABB PPMV PS-PMEL Circuit Diagram 1VCE014869T0100 A en Z10 &WT/A01
1 2 3 4 5 6 7 8

Вам также может понравиться