Вы находитесь на странице: 1из 62

PI-286

ISSUE 8

Technical Reference
3800 Series R13

JANUARY 2007

NEC Infrontia Corporation


PI-286
ISSUE 8
Revision Table
ISSUE DATE DESCRIPTION APPROVED BY PREPARED BY

1 Feb., 2002 New Issue (3000 series (R4.2) software)


Y. MATSUOKA S.ASANO
2 May, 2002 Addition of 3100 series (R5) software
Y. MATSUOKA S.ASANO
3 Feb, 2003 Addition of 3200 series (R6.2) software
Y. MATSUOKA S. EBISAWA
3.1 Feb, 2003 Reasons of revision
■ Correct errors Y. MATSUOKA S. EBISAWA
4 Feb, 2004 Addition of 3300 series (R8) software
Y. MATSUOKA M. INABA
5 Aug, 2005 Addition of 3400 series (R9) & 3500 series
(R10) software Y. MATSUOKA S.ASANO
6 Dec, 2005 Addition of 3600 series (R11) software
Y. MATSUOKA S.ASANO
7 Jul, 2006 Addition of 3700 series (R12) software
Y. MATSUOKA H.SHIRAI
8 Jan., 2007 Addition of 3800 series (R13) software
Y. MATSUOKA H.SHIRAI

Page 2
PI-286
ISSUE 8

LIABILITY DISCLAIMER

NEC Infrontia Corporation has prepared this document for use by its employees and NEC subsidiary.
The information contained herein is the property of NEC Infrontia Corporation and shall not be reproduced
without prior written approval from NEC Infrontia Corporation.
NEC Infrontia Corporation reserves the right to change the specifications, functions, or features, at any time,
without notice.

Copyright 2007
NEC Infrontia Corporation
Printed in Japan

Page 3
PI-286
ISSUE 8

NEAX 2000 IPS

TECHNICAL REFERENCE

TABLE OF CONTENTS

1. SYSTEM CAPACITY (Standalone system, 3800 series R13)...............................................6


1. SYSTEM CAPACITY (Standalone system, 3800 series R13)...............................................6
2. NUMBERING PLAN .................................................................................................................10
3. CLASS OF SERVICE ..............................................................................................................10
4. CONTROL SYSTEM ................................................................................................................11
5. PROCESSOR AND MEMORY................................................................................................11
6. TRAFFIC CAPACITY ...............................................................................................................11
7. PRODUCT RELIABILITY DATA..............................................................................................12
8. POWER REQUIREMENTS......................................................................................................13
(1) AC Input System .............................................................................................................................13
(2) DC Input System .............................................................................................................................14
9. OPEARTING ENVIRONMENT ................................................................................................14
10. ELECTRICAL CHARACTERISTICS (CENTRAL OFFICE TRUNK) ...................................15
11. TRANSMISSION CHARACTERISTICS.................................................................................16
12. LINE CONDITIONS................................................................................................................17
13. ROTARY DIAL AND DTMF SIGNAL ...................................................................................18
(1) Rotary Dial Signal............................................................................................................................18
(2) DTMF Signal ....................................................................................................................................18
14. MULTIFREQUENCY COMPELLED (MFC) – R2 SIGNAL .................................................19
(1) MFC Frequency Value ....................................................................................................................19
(2) MFC Combinations ..........................................................................................................................19
(3) Sender/Receiver Specifications .......................................................................................................19
15. RINGING SIGNAL..................................................................................................................19
16. DIMENSION AND WEIGHT ..................................................................................................20
17. Dterm 75 SERIES DIGITAL TERMINALS (Production Discontinued) .................................21
18. Dterm Series i (Standard Model)............................................................................................23
18. Dterm Series i (Russian-Display Model; 3600 series R11 or later) ...................................25
19. ATTENDATNT CONSOLE.....................................................................................................27
20. MAINTENANCE ADMINISTRATION TERMINAL (MAT) .....................................................28
(1) PC Requirements for MAT .............................................................................................................28
(2) Operating System (OS) Requirements for MAT ...........................................................................28
(3) Modem Requirements for Remote Maintenance ...........................................................................29
21. ANNOUNCEMENT SERVICE................................................................................................30

Page 4
PI-286
ISSUE 8
(1) Digital Announcement Trunk (DAT)................................................................................................30
(2) Service Capacity ..............................................................................................................................30
22. DATA COMMUNICATIONS ...................................................................................................31
Analog Port Adapter (APR)...................................................................................................................31
23. STATION MESSAGE DETAIL RECORDING (SMDR) .......................................................32
(1) SMDR TERMINAL INTERFACE .................................................................................................32
(2) SMDR OUTPUT FORMAT..............................................................................................................35
24. CALL INFORMATION SYSTEM (CIS) .................................................................................37
25. PROPERTY MANAGEMENT SYSTEM (PMS) INTERFACE .............................................39
26. MESSAGE CENTER INTERFACE (MCI) ............................................................................40
27. OPTICAL FIBER INTERFACE (Production Discontinued) .................................................41
28. VOICE MAIL SYSTEM (NEAXMail AD-8) ...........................................................................41
29. IP TRUNK INTERFACE ........................................................................................................42
30. IP STATION INTERFACE .....................................................................................................43
31. CENTRALIZED MAT..............................................................................................................45
(1) PC Requirements.............................................................................................................................45
(2) Version requirements for MATWorX and Centralized MAT .........................................................45
(3) PBX Requirements...........................................................................................................................46
32. REMOTE MAT .......................................................................................................................47
(1) PC Requirements.............................................................................................................................47
(2) PBX Requirements...........................................................................................................................47
33. Dterm ASSISTANT ...................................................................................................................48
(1) PC Requirements.............................................................................................................................48
(2) System Capacity ..............................................................................................................................49
34. IN-SKIN ROUTER (Production discontinued) ......................................................................50
APPENDIX A: MTBF OF EACH CARD .....................................................................................51
APPENDIX B: CURRENT CONSUMPTION OF EACH CARD ................................................54
APPENDIX C: PORT ALLOCATION...........................................................................................57
(1) General .........................................................................................................................................57
(2) LT Cards ......................................................................................................................................58
(3) AP Cards......................................................................................................................................60
APPENDIX D: Conditions of 32IP PAD and 8IP PAD.............................................................61

Page 5
PI-286
ISSUE 8
1. SYSTEM CAPACITY (Standalone system, 3800 series R13)
This table shows the maximum number of each item in a standalone system (with single MP).
System Capacity Note 1,2
Item
1PIM 2PIM 3PIM 4PIM 5PIM 6PIM 7PIM 8PIM
(No. of Ports) 64 128 192 256 320 384 448 512
LT Card
(No. of Cards) 12 24 36 48 60 72 84 96
(No. of Ports) Max. 256 ports per system
AP Card
(No. of Cards) 12 24
Total Number of Lines 64 128 192 256 320 384 448 512
(Analog Single Line Tel. + Dterm)
IP PAD (No. of Channel) 64 128 192 256
Note 9 (2 cards) (4 cards) (6 cards) (8 cards)
Analog Single Line Telephone Standard 64 128 192 256 320 384 448 512
(Lines) Long Note 5 48 96 144 192 240 288 336 384
Dterm (Lines) Standard 64 128 192 256 320 384 448 512
Long 24 48 72 96 120 144 168 192
Dterm IP/Dterm IP INASET/Dterm SP30 956 892 828 764 700 636 572 508
(Peer to Peer Connection)
Dterm PS (Australia/Asia) 512 Note 6
/ Dterm PSII / III (USA/LA)
WLAN Handset (MH250) 128
Dterm PS + WLAN Handset 512
Cell Station (CS) / Zone Transceiver (ZT) 16 32 48 64 80 96 112 128
24 32
P-P Connection (24) (32)
ISDN Station (2ILCC)
( ): Simultaneous Connection 192 256
P-MP Connection (48) (64)
Loop Start 64 128 192 256
Central Office Trunk (Lines)
DID w/4DIT 48 96 144 192 240 256
4LDT 48 96 144 192 240 256
Tie Line Trunk (Lines) 2W or 4W E&M 48 96 144 192 240 256 256 256
(4ODTA) (12) (24) (36) (48) (60) (72) (84) (96)
( ): Type I w/ PW122
CCIS Trunk (Peer to Peer Connection) Note10 Max. 127
1.5M-AMI DTI: 10, CCIS: 8
DTI/CCIS Digital Link Note 1
2M-AMI Max. 8 Links per system
1.5/2M-AMI
8
(PRT)
ISDN Trunk 2BRT (card)
(Production discontinued)
12 24
4BRT (card) 6 12 18 24 24 24 24 24
IP Trunk Note 3 1 2 3 4 5 6 7 8
PFT Connections 8PFT 8 16 24 32 40 48 56 64
3-Party Conference Max. 16 conference groups per system
6/10-Party Conference 6-Party Max. 4 conference groups per system
(Production discontinued) 10-Party Max. 2 conference groups per system
8-Party Conference Max. 8 conference group per system
32-Party Conference Max. 8 conference group per system

Page 6
PI-286
ISSUE 8
System Capacity (Standalone, Single MP System, Cont’d)

System Capacity
Item
1PIM 2PIM 3PIM 4PIM 5PIM 6PIM 7PIM 8PIM
In-skin Router (Production discontinued) Max. 8 cards per PIM
In-skin SIP Handler 1
Built-in Voice Mail (VM10) 1
DTMF Sender Max. 32 circuits per system
DTMF Receiver 16 32
SN716 Desk Console 8
SN708 Digital Console (Australia)
(Production discontinued)
8
SN709/712/741 Smart Console
(Production discontinued)
8
term
Attendant Terminal (D ATT Position) Max. 8 sets per system
Max. 2 interface ports per system (RS-232C)
SMDR Interface
Max. 1 port per system (IP)
PMS Interface Max. 1 interface port per system (RS-232C or IP)
ACD / MIS or OAI Interface Note 4 Max. 1 interface port per system (IP)
Remote PIM over IP (Number of Sites) 30 (depending on network configurations)
DID Dial Conversion 1,000
Call Forwarding-Outside Set 496
Authorization Code / Forced Account Code
3,000
/ Remote Access to System (DISA) Code
Message Reminder Set 1,024
Name Display / Guest Name Display 512
Speed Calling-Station (Station Speed Dial) Set 10,000
MP built-in SMDR Call Record 1,024
Note 1: The total number of trunk line and DTI channel shall be 256 or less.
(Each trunk line and DTI channel are required to assign the “Trunk Number” by system data programming
and maximum number of system parameter for “Trunk Number” is 256.)
Note 2: "PIM" in this table means "Physical PIM."

Page 7
PI-286
ISSUE 8
Note 3: Maximum voice channels per IP trunk card depends on the payload size as follows (payload size can
be assigned by system data programming):
„ CCIS (p-p/p-mp)

Payload Size G.729a G.711 G.723.1


10 ms 4 Channel 4 Channel ------
20 ms 8 Channel 8 Channel ------
30 ms 16 Channel 16 Channel 16 Channel
40 ms 16 Channel 16 Channel ------

„ VoIP (H.323)

Payload Size G.729a G.711 G.723.1


20 ms 6 Channel 5 Channel ---
30 ms 8 Channel 7 Channel 8 Channel
40 ms 12 Channel 10 Channel ---

Note 4: It is possible to connect 4 applications at the same time.

Note 5: Message Waiting Lamp is not available when the 4LLC is mounted in slot 08 to 11.

Note 6: From 3300 Series R8, maximum 256 PS can be accommodated to the system in addition to the
maximum 512 LT ports.
Ex: 400 Dterms+100 CO Lines=500 LT Ports
Total 600 Ports available
100 PSs

From 3400 Series R9, maximum 512 PS can be accommodated to the system.
The system provides up to 1020 ports (= LT port(max.512) + IP port(max.956) + PS port(max.512).

Note 7: Total number of CS should be 128 or less.

Page 8
PI-286
ISSUE 8
Note 8: Maximum number of voice channels per IP PAD card depends on the payload size as follows.

32IPLA+16VCTA
Payload Size Maximum Voice Channels per IP PAD
(32IPLA+16VCTA)
G.711 G.729a G.723.1
10ms 12 12 -
20ms 20 20 -
30ms 30 30 24
40ms 32 32 -

8IPLA+24IPLA
Payload Size Maximum Voice Channels per IP PAD
(8IPLA+24IPLA)
G.711 G.729a G.723.1
10ms 20 20 -
20ms 32 32 -
30ms 32 32 24
40ms 32 32 -
PN-8IPLA should be 3A or later version. SP-3213 IPS IPADT PROG-A1 should be 2A or later version.

Note 9: Number of IP PAD card is maximum 2 per FP.

Note 10: The number of P2P-CCIS trunk is calculated in terms of IP ports. In R8 and earlier release,
P2P-CCIS can be created in additional to TDM ports and IP ports. From 3400 series R9, there
are included in the IP ports (Max. 956).
In R8 and earlier release,
IP ports (Max.448) = DtermIP (Max.448 ports)
In R9 release,
IP ports (Max.956) = DtermIP (Max.956 ports) + P2P-CCIS (Max.127 ports)

Page 9
PI-286
ISSUE 8
2. NUMBERING PLAN
DESCRIPTION NUMBERING PLAN Note 1
Note 2
Station Access Max. 8 digits
Network Station Access Max. 8 digits Note 3
Attendant Access Max. 4 digits
Central Office Trunk Access Max. 4 digits
Tie Line Trunk Access Max. 4 digits
Miscellaneous Trunk Access Max. 4 digits
Service Feature Access Max. 4 digits
Notes:
1. Leading digit must be different.
2.
(1) When AP00 card with AP00 program is used (SMDR, Hotel/PMS, CIS Printer, MCI), station number must be
assigned up to 4 digits. (5-digit station number is available when the leading digit is a fixed number.)
(2) When AP00 card with MRCA program or MP built-in SMDR/PMS is used, station number must be assigned
up to 6 digits.
3. Closed numbering is used when 2000 IPS is connected with a FCCS network via CCIS.

3. CLASS OF SERVICE
CLASS OF SERVICE DESCRIPTION

Telephone Class There are 7 telephone classes depending on the type of telephone set:
(1) Single Line Telephone (DP, DTMF, DP/DTMF)
(2) Dterm
(3) House Phone
(4) Hot Line
(5) Automatic Intercom
(6) Dial Intercom
(7) Manual Intercom
Tenant Class Max. 64 tenant classes are available.
Trunk Restriction Class There are 8 trunk restriction classes as shown below:
(1) Unrestricted
(2) Non-restricted (1, 2)
(3) Semi-restricted (1, 2)
(4) Restricted (1, 2)
(5) Fully restricted
Service Restriction Class Max. 16 service feature classes are available for access to service
features.

Page 10
PI-286
ISSUE 8
4. CONTROL SYSTEM
DESCRIPTION SPECIFICATIONS

Control System Stored Program Control


Processor Type 32-Bit
Program Storage Flash ROM
Office Data Storage Flash ROM
Processor Architecture Central
Program Updates CD-ROM
Time Division Matrix PCM Time Division (1,024 x 1.024; Non-Blocking)

5. PROCESSOR AND MEMORY


CARD NAME PROCESSOR MEMORY CAPACITY
TYPE ROM RAM
MP (PN-CP24-A/B) 32-bit (133MHz) 8MB 32MB
(Flash ROM) (SDRAM)
MP (PN-CP24-C/D) 32-bit (133MHz) 16MB 64MB
(Flash ROM) (SDRAM)
MP (PN-CP27-A/B) 32-bit (133MHz) 8MB 32MB
(Flash ROM) (SDRAM)
MP (PN-CP26-A/B) 32-bit (133MHz) 8MB 32MB
(Flash ROM) (SDRAM)
MP (PN-CP31-A) 32-bit (133MHz) 8MB 32MB
(Flash ROM) (SDRAM)
MP (PN-CP31-C/D) 32-bit (133MHz) 16MB 64MB
(Flash ROM) (SDRAM)
MP (PN-CP28-A/B) 32-bit (133MHz) 8MB 32MB
(Flash ROM) (SDRAM)
FP (PN-CP15) 16-bit (25MHz) === 768KB

AP (PN-AP00-B) 16-bit (8MHz) 512KB 512KB


(Flash ROM)

6. TRAFFIC CAPACITY
DESCRIPTION SPECIFICATIONS

Busy Hour Call Attempts Max. 8,000 BHCA per system


• No FP : Max. 2,500 BHCA
• One FP : Max. 5,000 BHCA
• Two-FPs : Max. 7,500 BHCA
• Three-FPs : Max. 8,000 BHCA

Page 11
PI-286
ISSUE 8
7. PRODUCT RELIABILITY DATA
Following figures indicate the possibility of a part of system failure.

System for Asia/Latin America/Middle East/Africa/Russia

SYSTEM CONFIGURATION SYSTEM without LINE/TRUNK


(For single CPU) TDM Switching Configuration TDM/IP Switching Configuration
FIT MTBF (YEARS) FIT MTBF (YEARS)
1-PIM 24,400 4.7 32,843 3.5
2-PIM 38,250 3.0 46,693 2.4
3-PIM 55,160 2.1 63,603 1.8
4-PIM 69,010 1.7 77,453 1.5
5-PIM 85,920 1.3 94,363 1.2
6-PIM 99,770 1.1 108,213 1.1
7-PIM 116,680 1.0 125,123 0.9
8-PIM 130,530 0.9 138,973 0.8

<Single CPU Switching Configuration>

• TDM Switching Configuration

CP24-D PW121 PW121 CP15 PW121 PW121 CP15 PW121


(10550) (13850) (13850) (3060) (13850) (13850) (3060) (13850)

PIM0 PIM1 PIM2 PIM3 PIM4

• TDM/IP Switching Configuration

CP24-D PW121 M606-A 8IPLA+24IPLA PW121 CP15 PW121


(10550) (13850) (1269) (7174) (13850) (3060) (13850)

PIM0 PIM1 PIM2

PW121 CP15 PW121


(13850) (3060) (13850)

PIM3 PIM4
<Dual CPU Switching Configuration>
CP27-B M606-A
(10750) (1269)
PW121 8IPLA+24IPLA PW121 CP15 PW121
(13850) (7174) (13850) (3060) (13850)
CP27-B M606-A
(10750) (1269)

PIM0 PIM1 PIM2

PW121 CP15 PW121


(13850) (3060) (13850)

PIM3 PIM4
Refer to APPENDIX A for MTBF of each card.

Page 12
PI-286
ISSUE 8
8. POWER REQUIREMENTS
(1) AC Input System
„ AC Power Requirements

DESCRIPTION SPECIFICATIONS

AC Input Voltage 90 to 132Vac or 180 to 264Vac; 47 to 64Hz


AC Input Current 3.5A(at 100V), 2.0A(at 200V)

„ AC Power Consumption / Thermal Output (Maximum) (for single CPU configuration)

DESCRIPTION AC Power Consumption Thermal Output


(KVA) (BTU)
100V 200V 100V 200V
1-PIM 0.35 0.40 1,195 1,365
2-PIM 0.70 0.80 2,389 2,730
3-PIM 1.05 1.20 3,584 4,096
4-PIM 1.40 1.60 4,778 5,461
5-PIM 1.75 2.00 5,973 6,826
6-PIM 2.10 2.40 7,167 8,191
7-PIM 2.45 2.80 8,362 9,556
8-PIM 2.80 3.20 9,556 10,922

„ Battery Requirements

DESCRIPTION SPECIFICATIONS

Max. Battery Capacity 260AH per 4 PIM (65AH (12V) x 8)

DC Input Voltage for Battery -24V

Built-in Battery Requirements 3.4AH (12V) x 2 (approx. 30min. backup)

Physical Size of Built-in Battery 133(W) x 60(H) x 67(D) mm


(one 12V battery)

Refer to APPENDIX B for DC Current Consumption of each card.

Page 13
PI-286
ISSUE 8
(2) DC Input System
„ DC Power Requirements

DESCRIPTION SPECIFICATIONS

DC Input Voltage -36V to –53VDC


DC Input Current 7A

„ DC Power Consumption / Thermal Output (Maximum) (for single CPU configuration)

DESCRIPTION DC Power Consumption Thermal Output


(W) (BTU)
1-PIM 250 925
2-PIM 500 1,850
3-PIM 750 2,775
4-PIM 1,000 3,700
5-PIM 1,250 4,625
6-PIM 1,500 5,550
7-PIM 1,750 6,475
8-PIM 2,000 7,400

„ Battery Requirements

Battery backup should be prepared at DC –48V power source such as rectifier.

9. OPEARTING ENVIRONMENT
DESCRIPTION SPECIFICATIONS

Ambient Temperature 0 to 40℃


Relative Humidity Max. 90% (non-condensing)

Page 14
PI-286
ISSUE 8
10. ELECTRICAL CHARACTERISTICS (CENTRAL OFFICE TRUNK)
System for Asia/Latin America/Middle East/Africa/Russia

DESCRIPTION SPECIFICATIONS

Insulation Resistance 15 mega-ohms or more at 100Vdc


DC Resistance On-hook conditions: 30 mega-ohms
Off-hook conditions: 1,700 ohms
Impedance On-hook conditions: 20 kilo-ohms (300 to 3,400Hz)
8 kilo-ohms (at 24Hz)
Looped conditions: 600 ohms
Leak Current 0 mA at on-hook conditions

Page 15
PI-286
ISSUE 8
11. TRANSMISSION CHARACTERISTICS
System for Asia/Latin America/Middle East/Africa/Russia

DESCRIPTION SPECIFICATIONS

PCM Coding System A-law/U-law


Insertion Loss 0.15 dB at 1KHz
Return Loss 20 dB or more (300 to 3,400Hz) against 600 ohms
Longitudinal Balance 59 dB or more (300 to 3,400Hz)
Attenuation/Frequency Distortion -0.2 dB to +0.7 dB (300 to 3,400Hz)
Group Delay Distortion 0 to 0.3msec. (500 to 2,800 Hz)
Total Distortion 25 dB (Input signal:-45 dBm0)/40 dB(input signal:0 dBm0)
Idle Channel Noise -67 dBmop or less (psophometric noise)
-50 dBm0 or less (single frequency noise)
Impulsive Noise 0 counts at -35 dBm
Cross Talk Attenuation 90 dB or more
Intermodulation Products -40 dB or more
Spurious In-Band Signals -49 dBm0 or less
Signal Attenuation Attenuation rate: 12 dB per octave or more at 3.4 kHz above
Attenuation level: -40 dBm or less at 3.4 kHz and above
-70 dBm or less at 50 kHz and above

Page 16
PI-286
ISSUE 8
12. LINE CONDITIONS
DESCRIPTION SPECIFICATIONS

Loop Resistance (including Telephone Set)


„ Analog Standard Line Max. 600 ohms
„ Analog Long Line Max. 2,500 ohms (DP 10pps), Max. 1,700 ohms (DP 20pps)
Max. 1,200 ohms (DTMF)
Loop Resistance (including Opposite End Resistance)
„ Central Office Trunk Max. 1,700 ohms
„ Tie Line Trunk (Loop Dial) Note 3 Max. 2,500 ohms
„ Tie Line Trunk (E&M) Max. 900 ohms (only E-wire condition)
Cable Length Note 1
„ SN709/712/741 Smart Console (Production discontinued)
8DLC/4DLC Card Max. 150 meters
2DLC Card Max. 600 meters
„ SN716 Desk Console
8DLC/4DLC/2DLC Card Max. 350 meters (Max. 300 meters for 8DLC card)
4DLC Card with Max. 1,200 meters
AC Adapter
„ Dterm 75 (Production discontinued)
8DLC/4DLC Card (-27V) Max. 200 meters (Max. 300 meters for Dterm 8 and Dterm 8D)
4DLC/2DLC Card (-48V) Max. 850 meters
4DLC/2DLC Card with Max. 1,200 meters
AC Adapter
„ Dterm Series i
8DLC/4DLC Card (-27V) Max. 200 meters
(Max. 300 meters for Dterm 8 / 8D and Dterm 16D / 16LD)
4DLC/2DLC Card (-48V) Max. 850 meters
4DLC/2DLC Card with Max. 1,200 meters
AC Adapter
„ DSS/BLF Console
4DLC/2DLC Card with Max. 1,200 meters
AC Adapter (Max. 300 meters for 8DLC Card)
„ Cell Station Note 3
BS21A (for S-Interface) Max. 900 meters @-43V
BS21A with AC Adapter Max. 960 meters @-43V
BS31/BS41 (for U-Interface) Max. 800 meters (2-wire), Max. 1,600 meters (4-wire) @-43V Note 2
BS31/BS41 with AC Adapter Max. 5000 meters
„ Zone Transceiver (for Latin America)
ZTII-S (for S-Interface) Max. 1,219 meters @-48V, Max. 975 meters @-45V
ZTII-S with AC Adapter Max. 1,341 meters @-48V
ZTII-U (for U-Interface) Max. 1,219 meters (2-wire), Max. 2,103 meters (4-wire) @-48V Note 2

Max. 975 meters (2-wire), Max. 1,706 meters (4-wire) @-45V


ZTII-U with AC Adapter Max. 3,958 meters
Notes
1: Cable length is based on cable with 0.5mm diameter and without lightning arresters.
2: Retrofit system applies following conditions:
BS31/BS41 (for U-Interface) Max. 600 meters (2-wire), Max. 1,200 meters (4-wire) @-43V
ZTII-U (for U-Interface) Max. 880 meters (2-wire), Max. 1,520 meters (4-wire) @-43V

Page 17
PI-286
ISSUE 8

13. ROTARY DIAL AND DTMF SIGNAL


(1) Rotary Dial Signal

DESCRIPTION SPECIFICATIONS
Receiving Sending
„ Dial Speed 9 to 22 pps 10 pps +/- 0.8pps
20 pps +/- 0.8 pps
„ Break Ratio 55 to 77 % 67 +/- 3% or 62 +/- 3%
„ Inter-Digit Pause Min. 256 msec. 300 to 1,000 msec.(10 pps)
„ Switch-Hook Flash Detection 384 to 2,300 msec. Not applicable

(2) DTMF Signal

DESCRIPTION SPECIFICATIONS
Receiving Sending
„ Signal Code
High Frequency Group 1,209Hz 1,336Hz 1,477Hz
Low Frequency Group 697Hz 1 2 3
770Hz 4 5 6
852Hz 7 8 9
941Hz * 0 #

„ Frequency Deviation +/- 1.8 % +/- 0.8 %


„ Signal Duration Min. 40 msec. 64 or 128 msec.
„ Inter-Digit Pause Min. 40 msec. 32 to 240 msec.
„ Signal Level -46 to -5 dBm -10 dBm (low group)
- 8 dBm (high group)
„ Unwanted Frequency Not Applicable 40 dB below the power of signal
Components frequency

Page 18
PI-286
ISSUE 8
14. MULTIFREQUENCY COMPELLED (MFC) – R2 SIGNAL
(1) MFC Frequency Value
FREQUENCIES FORWARD SIGNALS(Hz) BACKWARD SIGNALS(Hz)

F0 1,380 1,140
F1 1,500 1,020
F2 1,620 900
F3 1,740 780
F4 1,860 660
F5 1,980 540

(2) MFC Combinations


COMBINATION NUMBER FREQUENCIES

1 F0 + F1
2 F0 + F2
3 F1 + F2
4 F0 + F3
5 F1 + F3
6 F2 + F3
7 F0 + F4
8 F1 + F4
9 F2 + F4
10 F3 + F4
11 F0 + F5
12 F1 + F5
13 F2 + F5
14 F3 + F5
15 F4 + F5

(3) Sender/Receiver Specifications


DESCRIPTION SPECIFICATIONS
Sender
„ Sender Transmitted Level -8 dbm to -11.5 dBm
„ Frequency Variation +/- 2 Hz
Receiver
„ Sensitivity Range -35 dBm to 0 dBm
„ Frequency Variation +/- 12 dBm

15. RINGING SIGNAL


DESCRIPTION SPECIFICATIONS

Frequency 20 or 25Hz
Voltage 75 or 90Vrms
The 2000 IPS has the capability to detect the above type of signal from Central Office and to transmit the
above type of signal to PBX stations.

Page 19
PI-286
ISSUE 8
16. DIMENSION AND WEIGHT
DESCRIPTION SPECIFICATIONS
DIMENSIONS (W x D x H; mm) WEIGHT (kg)
Main Equipment
„ PIM (Fully card-mounted) Approx. 430 x 223 x 353 Approx. 11.5
„ BASE Approx. 430 x 205.2 x 61.6 Approx. 3.0
„ BASE TRAY (for UL) Approx. 435 x 224.6 x 66.2 Approx. 1.7
Dterm 75 Series
„ Dterm 8 Approx. 177 x 224 x 76 Approx. 1.0
„ Dterm 8D Approx. 177 x 229 x 98 Approx. 1.1
„ Dterm 16D Approx. 177 x 229 x 98 Approx. 1.1
„ Dterm 32D Approx. 201 x 229 x 98 Approx. 1.1
„ DSS Console Approx. 177 x 218 x 74 Approx. 0.7
term
D Series i
„ Dterm 2DT Approx. 165 x 221 x 92 Approx. 0.9
„ Dterm 4D Approx. 215 x 193 x 142 Approx. 0.9
„ Dterm 8 Approx. 231 x 217 x 106 Approx. 1.1
„ Dterm 8D Approx. 231 x 217 x 106 Approx. 1.2
„ Dterm 16D Approx. 231 x 217 x 106 Approx. 1.2
„ Dterm 16LD Approx. 232 x 252 x 106 Approx. 1.35
„ Dterm 32D Approx. 232 x 243 x 106 Approx. 1.3
„ DSS Console Approx. 175 x 216.3 x 92 Approx. 0.6
Dterm Series i (Russian display model)
„ Dterm 8D-R Approx. 175 x 226 x 96 Approx. 0.8
term
„ D 16D-R Approx. 175 x 226 x 96 Approx. 0.8
„ Dterm 32D-R Approx. 193 x 226 x 96 Approx. 0.9
Attendant Console
„ SN709/712/741 Smart Console Approx. 264 x 230 x 110 Approx. 1.3
(Production discontinued)
„ SN716 Desk Console Approx. 277 x 258 x 132 Approx. 1.4

Page 20
PI-286
ISSUE 8
17. Dterm 75 SERIES DIGITAL TERMINALS (Production Discontinued)
DESCRIPTION SPECIFICATIONS
Dterm 8 Dterm 8D Dterm 16D Dterm 32D
Max. Number of Line 8* 8* 16* 32*
/Programmable Feature Keys
Number of Dedicated Feature Keys 11 11 11 11
„ Speaker YES YES YES YES
„ Answer YES YES YES YES
„ Hold YES YES YES YES
„ Transfer YES YES YES YES
„ Recall YES YES YES YES
„ Conference YES YES YES YES
„ Redial YES YES YES YES
„ Feature YES YES YES YES
„ Volume Control YES YES YES YES
Number of Soft Keys NO 4 4 4

LED Indicator Green/Red Green/Red Green/Red Green/Red


(on Line/Feature Keys)
LCD Display NO 24 x 3 24 x 3 24 x 3
(Number of Characters x Lines)
Language of message displayed on NO English English English
LCD Note 1 Spanish Spanish Spanish
Portuguese Portuguese Portuguese
French French French
Call Indicator LED YES YES YES YES
/Message Waiting LED

Accessories
„ Headset Jack Connecter Built-in Built-in Built-in Built-in
Note 2

„ Hands-Free Unit Built-in Built-in Built-in Built-in


„ DSS/BLF Console Note 3 Option Option Option Option
„ Ancillary Device Adapter (ADA) Option Option Option Option
„ Analog Port Adapter (APR) Option Option Option Option
Note 3,4

„ CTI Adapter (CTA) Note 3,4 Option Option Option Option


„ IP Adapter (IPW) Note 3,4 NO Option Option Option
„ Wall Mount Unit Note 5 Option Option Option Option
„ AC Adapter Option Option Option Option
Cabling 1-Pair 1-Pair 1-Pair 1-Pair
Max. Cable Length Note 6
„ 8DLC/4DLC Card 300m 300m 300m 200m
„ 2DLC Card 850m 850m 850m 850m
„ 4DLC/2DLC Card 1,200m 1,200m 1,200m 1,200m
with AC Adapter
Color White / Black White / Black White / Black White / Black

* Keys may be programmed to support a variety of combinations.

Page 21
PI-286
ISSUE 8
Notes:
1. One of below languages is assigned in system basis.
English
Spanish
Portuguese
French
2. Plantronics Supra-NC Polaris (Product Code: P51N-U 10P) is recommended.
3. It requires an AC/DC adapter.
4. A Dterm can equip only one out of following three adapters at the same time :
- Analog Port Adapter (APR)
- CTI Adapter (CTA)
- IP Adapter (IPW)
5. A Wall Mount Unit is required when the Dterm set with an optional adapter is wall-mounted. The Dterm set
without an optional adapter can be wall-mounted without the Wall Mount Unit.
6. Cable length is based on the cable with 0.5mm diameter and without lightning arresters.

Page 22
PI-286
ISSUE 8
18. Dterm Series i (Standard Model)
DESCRIPTION SPECIFICATIONS
term term term term term term term
D 2DT D 4D D 8 D 8D D 16D D 32D D 16LD
Note 9 Note 9
*
Max. Number of Line 2 4 8* 8* 16* 32 16
/Programmable Feature Keys (with LED) (with LED) (with LED) (with LED) (with LED) (with LED) (with LCD)
Number of Dedicated Feature Keys 9 9 11 11 11 11 11
Speaker YES YES YES YES YES YES YES
Answer YES YES YES YES YES YES YES
Hold YES YES YES YES YES YES YES
Transfer YES YES YES YES YES YES YES
Recall YES YES YES YES YES YES YES
Conference YES YES YES YES YES YES YES
Redial YES YES YES YES YES YES YES
Feature YES YES YES YES YES YES YES
MIC YES YES YES YES YES YES YES
Directory NO NO YES YES YES YES YES
Message NO NO YES YES YES YES YES
Volume Control Keys YES YES YES YES YES YES YES
Number of Soft Keys NO 4 NO 4 4 4 4
Indicator on Line/Feature Keys LED LED LED LED LED LED LCD icon
NOTE 7
Green/Red Green/Red Green/Red Green/Red Green/Red Green/Red
LCD Display NO 24 x 3 NO 24 x 3 24 x 3 24 x 3 24 x 3
(Number of Characters x Lines)

Multilanguage display on 24 x 3 LCD Note 1 NO 12 language 12 language 12 language 12 language 12 language 12 language
Call Indicator LED YES YES YES YES YES YES YES
/Message Waiting LED
Accessories
Note 2
Headset Jack Connecter NO NO Built-in Built-in Built-in Built-in Built-in
Hands-Free Unit Built-in Built-in Built-in Built-in Built-in Built-in Built-in
DSS/BLF Console Note 3 Option Option Option Option Option Option Option
Note8
16LD ADM NO NO NO NO NO NO Option
Ancillary Device Adapter (ADA) NO NO Option Option Option Option Option
Note 3,4
Analog Port Adapter (APR) NO NO Option Option Option Option Option
Note 3,4
CT Adapter (CTA) NO NO Option Option Option Option Option
Note 3,4
IP Adapter (IPW) NO NO NO Option Option Option Option
Note 5
Wall Mount Unit NO NO Option Option Option Option Option
AC Adapter NO NO Option Option Option Option Option
Analog Data Port YES NO NO NO NO NO NO
(for modem connection, outgoing call only)
Cabling 1-Pair 1-Pair 1-Pair 1-Pair 1-Pair 1-Pair 1-Pair
Max. Cable Length Note 6
8DLC/4DLC Card 300m 300m 300m 300m 300m 200m 300m
2DLC Card 850 850m 850m 850m 850m 850m 850m
4DLC/2DLC Card with AC Adapter NO NO 1,200m 1,200m 1,200m 1,200m 1,200m
Color White / Black White / Black White / White / Black White / Black White / Black
Black Black

Page 23
PI-286
ISSUE 8
Notes:
1. One of below languages is assigned in system basis (R10 o earlier software).
One of below language can be assigned per terminal basis (R11 or later software).
- Danish
- Dutch
- English
- French (Canadian)
- French (European)
- German
- Italian
- Portuguese (Brazilian)
- Portuguese (European)
- Spanish (Latin)
- Spanish (European)
- Swedish
2. Plantronics Supra-NC Polaris (Product Code: P51N-U 10P) is recommended.
3. It requires an AC/DC adapter.
4. A Dterm can equip only one out of following three adapters at the same time:
(Bundle type Dterm IP (16D/32D) can not equip any of the following adapters.)
- Analog Port Adapter (APR)
- CTI Adapter (CTA)
- IP Adapter (IPW)
5. A Wall Mount Unit is required when the Dterm set with an optional adapter is wall-mounted.
The Dterm set without an optional adapter can be wall-mounted without the Wall Mount Unit.
6. Cable length is based on the cable with 0.5mm diameter and without lightning arresters.
7. LCD beside Line/Feature keys displays only English.
8. 16LD ADM is available with 3500 series R10 or later software.
16LD ADM is not available for China.
9. Dterm 2DT and Dterm 4D are available with 3200 series R6.1 or later software.

Page 24
PI-286
ISSUE 8
18. Dterm Series i (Russian-Display Model; 3600 series R11 or later)
DESCRIPTION SPECIFICATIONS
term term term
D 8D-R D 16D-R D 32D-R
Max. Number of Line 8 16 16
/Programmable Feature Keys (with LED) (with LED) (with LED)
Number of One-Touch Dial Keys NO NO 16
Number of Dedicated Feature Keys 10 10 10
Speaker YES YES YES
Answer YES YES YES
Hold YES YES YES
Transfer YES YES YES
Recall YES YES YES
Conference YES YES YES
Redial YES YES YES
Feature YES YES YES
MIC NO NO NO
Call YES YES YES
Volume Control keys YES YES YES
Number of Soft Keys 4 4 4
Indicator on Line/Feature Keys LED LED LED
Green/Red Green/Red Green/Red
LCD Display 24 x 3 24 x 3 24 x 3
(Number of Characters x Lines)
Note 1
Multilanguage display on 24 x 3 LCD 13 language 13 language 13 language
Call Indicator LED YES YES YES
/Message Waiting LED
Accessories
Note 2
Headset Jack Connecter Built-in Built-in Built-in
Hands-Free Unit Built-in Built-in Built-in
DSS/BLF Console Note 3, 7 Option Option Option
Note8
16LD ADM NO NO NO
Ancillary Device Adapter (ADA) Option Option Option
Note 3,4
Analog Port Adapter (APR) Option Option Option
CT Adapter (CTA) Note 3,4 Option Option Option
Note 3,4
IP Adapter (IPW) NO NO NO
Wall Mount Unit Note 5 Option Option Option
AC Adapter Option Option Option
Cabling 1-Pair 1-Pair 1-Pair
Max. Cable Length Note 6
8DLC/4DLC Card 300m 300m 300m
2DLC Card 850m 850m 850m
4DLC/2DLC Card with AC Adapter 1200m 1200m 1200m
Color White White White

Page 25
PI-286
ISSUE 8
Notes:
1. One of below language can be assigned per terminal basis (R11 or later software).
- Danish
- Dutch
- English
- French (Canadian)
- French (European)
- German
- Italian
- Portuguese (Brazilian)
- Portuguese (European)
- Spanish (Latin)
- Spanish (European)
- Swedish
- Russian
2. Plantronics Supra-NC Polaris (Product Code: P51N-U 10P) is recommended.
3. It requires an AC/DC adapter.
4. A Dterm can equip only one out of following two adapters at the same time:
- Analog Port Adapter (APR)
- CTI Adapter (CTA)
5. A Wall Mount Unit is required when the Dterm set with an optional adapter is wall-mounted.
The Dterm set without an optional adapter can be wall-mounted without the Wall Mount Unit.
6. Cable length is based on the cable with 0.5mm diameter and without lightning arresters.
7. DSS/BLF Console is one for Dterm series I (Standard Model).

Page 26
PI-286
ISSUE 8
19. ATTENDATNT CONSOLE

DESCRIPTION SPECIFICATIONS
Smart Console (SN709/712/741) Desk Console (SN716)
(Production discontinued)
Number of Loop Keys Note 1 6
Number of Multi-Function Keys 6 4
Incoming Call Identification keys 6 6
Function Keys 8 18
„ PAGE Key Yes Note 2 Yes
„ REC Key No Yes
„ Mute Key No Yes
„ Night Key Yes Note 3 Yes
„ Position Busy Key Yes Note 3 Yes
„ Volume Control Key Yes Note 4 Yes
(Receiver volume, Ringer
volume, LCD contrast)
LED indicator on Loop Keys / 2-Color
Function Keys (Green, Red)
LCD Display Yes
(Number of Characters x Lines) (40 x 4)
Handset/Headset Jack Connector Yes
Note 5

2nd Headset Jack Connector Note 5


No Yes
Alarm Indication No Yes
Busy Lamp Field By DSS/BLF Console
Cabling 1-pair 1-pair (local power feeding)
3-pair (remote power feeding) Note 6
Note 7
Cable Length Max. 150m (8DLC) Max. 300m (remote power feeding)
Max. 600m (2DLC) Max. 1,200m (local power feeding)
Notes:
1. Max. 12 calls can be handled per console at a time by “Attendant Loop Release” feature.
2. Programmable Function Key can provide Paging Key.
3. Multi-Function Key (MODE Key) can provide Night Mode and Position Busy settings.
4. Separate keys adjust ringer volume and LCD contrast. Receiver volume cannot be adjusted.
5. Plantronics Supra New Sigma (product Code: F53U-U03F) is recommended.
6. Remote power feeding requires one PW00 card per Console.
7. Cable length is based on the cable of 0.5mm diameter, without lightning arresters.

Page 27
PI-286
ISSUE 8
20. MAINTENANCE ADMINISTRATION TERMINAL (MAT)
(1) PC Requirements for MAT

„ For Windows 95/98/NT Note


DESCRIPTION SPECIFICATIONS
Minimum Recommended
CPU PentiumⅡ 200 MHz PentiumⅢ 500MHz
RAM 64MB 128MB
Hard Disk Drive (HDD) 200MB or more 200MB or more
Monitor SVGA (800 x 600) 15-inch or larger SVGA
High color (16-bit) (1,024 x 768)
True Color (32-bit)
Peripherals LAN Interface Card, CD-ROM Drive,
Floppy Disk Drive, Keyboard, Mouse
Note: Windows 95 must be OSR2 or later version. Windows NT4.0 must be SP5 or later version.

„ For Windows 2000/ Me / XP / 2003 (Windows 2003 is available from MATWorX Ver.11)
DESCRIPTION SPECIFICATIONS
Minimum Recommended
CPU PentiumⅡ 350 MHz PentiumIV 1GHz
RAM 128MB 256MB
Hard Disk Drive (HDD) 230MB or more
Monitor SVGA (800 x 600) SVGA (1,024 x 768)
High color (16-bit) True Color (32-bit)
15-inch or larger monitor
Peripherals LAN Interface Card, CD-ROM Drive,
Floppy Disk Drive, Keyboard, Mouse

Note: Key FD (name with –B1) with Software License Authentication can be loaded from a PC with Microsoft
Windows XP, 2000 and NT4.0 (SP5 or later version), in addition to Windows 95 (OSR2 or later version),
98, Me. Key FD (name with –A1) with non-Software License Authentication must be loaded from a PC
with Windows 95 (OSR2 or later version), 98, Me.

(2) Operating System (OS) Requirements for MAT

„ OS Compatibility of MATWorX

95 98 98SE Me NT4 2000 2003 XP Vista


MATWorX X X X X X X N/A X N/A
Ver.10 or
earlier
MATWorX N/A N/A N/A X N/A X X X N/A
Version 11
or later
MATWorX N/A N/A N/A N/A N/A X X X N/A
Version 11
or later
(Russian)

Note: Windows OS must be English version.


Latest Service Pack (SP) for Windows OS should be applied.
Russian MATWorX must be used with 3600 series R11 or later software.
Page 28
PI-286
ISSUE 8

(3) Modem Requirements for Remote Maintenance

DESCRIPTION SPECIFICATIONS

Remote Maintenance via ITU-T V.34 (33.6Kbps), ITU-T V.32bis (14.4Kbps)


Built-in Modem AT command must be supported.
Remote maintenance via ITU-T V.34 (33.6Kbps), ITU-T V.32bis (14.4Kbps)
External Modem AT command must be supported.
Same modem must be used for both PBX and MAT side.

Page 29
PI-286
ISSUE 8
21. ANNOUNCEMENT SERVICE
(1) Digital Announcement Trunk (DAT)

DESCRIPTION SYATEM CAPACITY

No. of Announcement Channels per Max. 4 channels per card


Card
Message Length per Channel Max. 120 sec. per channel

(2) Service Capacity

DESCRIPTION SYATEM CAPACITY


1-PIM 2-PIM 3-PIM 4-PIM 5-PIM 6-PIM 7-PIM 8-PIM
Max. Number of 4DAT Cards 8 8 16 16 24 24 32 32
per System Note
Max. Number of 4DAT Cards per Application
„ Announcement Service 8 8 16 16 24 24 32 32
„ Announcement Service when 8 8 16 16 24 24 32 32
DID/Tie Line call terminates to a
busy station
„ Announcement Service when 8 8 16 16 24 24 32 32
the called station does not
answer a DID/Tie Line call
„ Attendant Delay Announcement 8 8 16 16 16 16 16 16
„ Automated Attendant 8 8 16 16 24 24 32 32
„ Automatic Waku-Up /
Timed Reminder
„ Call Forwarding-Intercept/ 1 1 1 1 1 1 1 1
Announcement
„ Message-on Hold 8 8 16 16 24 24 32 32
„ Transferred Trunk Line 8 8 16 16 24 24 32 32
Message Service (No Answer)
„ Transferred Trunk Line 8 8 16 16 24 24 32 32
Message Service (Busy)
„ UCD Delay Announcement 8 8 16 16 24 24 32 32
Service
„ UCD Overflow Announcement 8 8 16 16 24 24 32 32
„ Announcement-PS No Answer 8 8 16 16 24 24 32 32
„ Announcement-PS Busy 8 8 16 16 24 24 32 32
„ Announcement-PS out of Zone/ 8 8 16 16 24 24 32 32
Power Off
„ Voice Guide 8 8 16 16 24 24 32 32
Note: 2DAT circuits are included in the MP card.

Page 30
PI-286
ISSUE 8
22. DATA COMMUNICATIONS
Analog Port Adapter (APR)

DESCRIPTION SPECIFICATIONS

Max. Data Speed through APR 33.6Kbps

Impedance 600 ohms


Dialing DTMF
Ringing Voltage/Frequency 110 Vrms / 18 Hz
Loss Plan COT -> APR 0 dB
APR -> COT 0 dB
Station -> APR -6 dB
APR -> Station 0 dB
Feeding Current 20mA
Loop Resistance Max. 5.4 ohms (approx. 15m)
Switch Hook Flash (SHF) Detect Available
Momentary Open Detect Available
Message Waiting Lamp Control Not Available
Branch Connection on Analog Line Not Available

Page 31
PI-286
ISSUE 8
23. STATION MESSAGE DETAIL RECORDING (SMDR)
(1) SMDR TERMINAL INTERFACE

<AP00 / MP built-in SMDR on RS-232C>


DESCRIPTION SPECIFICATIONS
Built-in SMDR on RS-232C SMDR by AP00 SMDR by AP00
by MP Note 1, 2, 3 (SPN-AP00B (SPN-AP00B MRC-E(AP)
MRC-C(AP)) or later / SPN-AP00D
MRC-B(AP))
Type of Calls Applicable to SMDR Outgoing Call Outgoing Call Outgoing Call
Service Incoming Call Incoming Call Incoming Call
Tandem Call Tandem Call Tandem Call
Internal Call Note 7 Internal Call Note7
Interface Conditions
„ Physical Interface RS-232C
„ Procedure Non-Protocol (Free Wheel)
„ Synchronization Asynchronous
„ Transmission Speed 1200 / 2400 / 4800 / 9600 1200 / 2400 / 4800 / 300/ 1200 / 2400 /
/19200 bps 9600 bps 4800 / 9600/
19200 bps
Station Number Max. 6 digits Max. 4 digits Note 4 Max. 6 digits

Note 5
I/O Port RS port of MP card No. 0-3 port of AP00- card

Number of Trunks Supported Max. 255 Trunks

Number of Stations Registered Max. 1,020 stations Max. 504 stations Max. 1,020 stations
Pseudo-Answer Timing for Charging 8 to 40 sec. (programmable in 4-sec. increment)
Start
Charging to a Transferred Call Note 6 The Following options are available by data programming:
(1) Split charging to both transfer destination station and the
transferring station.
(2) Charging to the final transfer destination.
(3) Charging to the first transfer destination station.

Notes:
1. Built-in SMDR on RS-232C cannot be provided when SPN-AP00B MRC-C(AP) or earlier is used.
2. In Built-in SMDR on RS-232C, MP reset clears the call records stored in buffer memory.
3. Built-in SMDR on RS-232C can be used for remote office in Centralized Billing of CCIS network.
4. 5-digit station number is available when the leading digit is fixed number.
5. RS-232C Interface port is max. 2 ports per system.
6. In case of call transfer between an Attendant Console and a station, the charging is made to the station,
in any data programming.
7. SMDR for internal calls is available from 3600 series R11 or later software.
AP00 must be SPN-AP00B MRC-F (AP) or later (PN-AP00-B with SC-3480 PROG-B1) or later / SPN-AP00D
MRC-B(AP) (PN-AP00-D with SC-3682 IPS MRCA PROG-D1).

Page 32
PI-286
ISSUE 8

<MP built-in SMDR on IP>


DESCRIPTION SPECIFICATIONS
Built-in SMDR on IP by MP Note 1, 2, 3
Type of Calls Applicable to SMDR Outgoing Call
Service Incoming Call
Tandem Call
Internal Call Note 5
Interface Conditions
„ Physical Layer Ethernet
„ Connection layer The Ethernet packet format conforms to the DIX standard.
„ TCP/IP core protocol ARP, IP, ICMP, UDP, TCP
„ Socket interface Conforming to 4.3 BSD socket interface
„ Transport protocol TCP stream type protocol
„ Application port number 60,010
„ Number of connections 1 connection
„ Client/server Client: SMDR terminal
Server: PBX
„ Transmission code 7-bit, ASCII code
„ Pseudo-normal condition 1. When connection is closed
2. Status monitoring text
Number of Trunks Supported Max. 255 Trunks

Number of Stations Registered Max. 1,020 stations


Pseudo-Answer Timing for Charging 8 to 40 sec. (programmable in 4-sec. increment)
Start
Charging to a Transferred Call Note 4 The Following options are available by data programming:
(4) Split charging to both transfer destination station and the
transferring station.
(5) Charging to the final transfer destination.
(6) Charging to the first transfer destination station.

Notes:
1. Built-in SMDR on IP is available from 3400 series R9 software.
2. Built-in SMDR on IP cannot be provided when SPN-AP00B MRC-C(AP) or earlier is used.
3. In Built-in SMDR on IP, MP reset clears the call records stored in buffer memory
4. In case of call transfer between an Attendant Console and a station, the charging is made to the station,
in any data programming.
5. SMDR for internal calls is available from 3600 series R11 or later software.

Page 33
PI-286
ISSUE 8

<Buffer Memory Capacity>


Types of SMDR Buffer Memory Capacity
For own office
Built-in SMDR on RS-232C Max. 1,024 calls Note1
Built-in SMDR on IP Max. 1,024 calls Note1
SPN-AP00B MRC-C(AP)* or earlier Max. 1,600calls (Max. 27,000 calls) Note2, 3, 4
SPN-AP00B MRC-E(AP)** or later Max. 2,620calls (Max. 23,580 calls) Note2, 3
SPN-AP00D MRC-B(AP)*** Max. 23,580 calls Note2
For center office (own office) of Centralized Billing-CCIS
Built-in SMDR on RS-232C -
Built-in SMDR on IP Max. 1,024 calls Note1
SPN-AP00B MRC-C(AP)* or earlier Max. 800calls (Max. 27,000 calls) Note2, 3, 4
SPN-AP00B MRC-E(AP)** or later Max. 1,310calls (Max. 22,270 calls) Note2,3
SPN-AP00D MRC-B(AP)*** Max. 2,2270 calls Note2
For center office (local/tandem billing info.) of Centralized Billing-CCIS
Built-in SMDR on RS-232C -
Built-in SMDR on IP Not stored
SPN-AP00B MRC-C(AP)* or earlier Max. 512 calls
SPN-AP00B MRC-E(AP)** or later Max. 512 calls
SPN-AP00D MRC-B(AP)*** Max. 512 calls
For local office of Centralized Billing-CCIS
Built-in SMDR on RS-232C Max. 1,024 calls Note1
Built-in SMDR on IP -
SPN-AP00B MRC-C(AP)* or earlier Max. 1,600calls (Max. 27,000 calls) Note2, 3, 4
SPN-AP00B MRC-E(AP)** or later Max. 2,620calls (Max. 23,580 calls) Note2,3
SPN-AP00D MRC-B(AP)*** Max. 23,580 calls Note2
*SPN-AP00B MRC-C(AP) is PN-AP00-B card with SC-3005 IXS AP PROG-D1 firmware.
**SPN-AP00B MRC-E(AP) is PN-AP00-B card with SC-3168 IXS AP PROG-A1 firmware.
***SPN-AP00D MRC-B(AP) is PN-AP00-D card with SC-3682 IPS MRCA PROG-D1 firmware.

Notes:
1. When the number of call records stored reaches the buffer capacity, new call records will be lost.
2. When the number of call records stored reached the buffer capacity, the system operates in one of the
following methods, by data programming.
(1) No new call record is stored.
(2) New call record is stored by deleting the oldest call record.
3. Figure in parenthesis is buffer memory capacity when Expansion Memory (PZ-M537) is equipped on
AP00B card.
4. When both SMDR and CIS are used in the system, the buffer memory capacity is Max. 26,000 calls
including CIS buffer memory.

Page 34
PI-286
ISSUE 8
(2) SMDR OUTPUT FORMAT

<SMDR output format>


X: Available -: Not available
Types of SMDR 2400IMS 2400IMS 1400IMS format
Standard format Extended format
For own office
Built-in SMDR on RS-232C X X Note1 -
Built-in SMDR on IP X Note1 X Note1 -
SPN-AP00B MRC-C(AP)* or earlier X - X
SPN-AP00B MRC-E(AP)** or later Note6 X X Note2 -
SPN-AP00D MRC-B(AP)*** Note6
X X Note2 -
For center office of Centralized Billing-CCIS
Built-in SMDR on RS-232C - - -
Built-in SMDR on IP X Note1,3 X Note1,3 -
SPN-AP00B MRC-C(AP)* or earlier X - -
Note6 Note1,4
SPN-AP00B MRC-E(AP)** or later X X -
SPN-AP00D MRC-B(AP)*** Note6 X X Note1,4 -
For local office of Centralized Billing-CCIS
Built-in SMDR on RS-232C X Note5 X Note5 -
Built-in SMDR on IP - - -
SPN-AP00B MRC-C(AP)* or earlier X - -
SPN-AP00B MRC-E(AP)**or later Note6 X - -
SPN-AP00D MRC-B(AP)*** Note6 X - -
*SPN-AP00B MRC-C(AP) is PN-AP00-B card with SC-3005 IXS AP PROG-D1 firmware.
**SPN-AP00B MRC-E(AP) is PN-AP00-B card with SC-3168 IXS AP PROG-A1 firmware.
***SPN-AP00D MRC-B(AP) is PN-AP00-D card with SC-3682 IPS MRCA PROG-D1 firmware.

Notes:
1. This feature is available from 3400 series R9 software.
2. This feature is available from 3300 series R8 software.
3. When a communication is disconnected, the billing information is stored at local office.
4. Firmware program (SC-3168 IXS AP PROG-A1) issue 2 or later is required.
5. The billing information cannot be output at local office.
When a failure of center office occurs or the CCIS link is disconnected, the billing information is stored at
local office.
6. SPN-AP00B MRC-E(AP) or later / SPN-AP00D MRC-B(AP) do not support the following features
- SMDR 1400IMS format - Hotel Printer - CIS

Page 35
PI-286
ISSUE 8

<Combination patterns of output available at the same time>


X: Available -: Not available
Types of SMDR Pattern A Pattern B
Built-in SMDR on RS-232C Note1,2 X -
Built-in SMDR on IP Note1,2 - X
Note3
SPN-AP00B MRC-C(AP)* or earlier - -
SPN-AP00B MRC-E(AP)** or later X X
SPN-AP00D MRC-B(AP)*** X X
*SPN-AP00B MRC-C(AP) is PN-AP00-B card with SC-3005 IXS AP PROG-D1 firmware.
**SPN-AP00B MRC-E(AP) is PN-AP00-B card with SC-3168 IXS AP PROG-A1 firmware.
***SPN-AP00D MRC-B(AP) is PN-AP00-D card with SC-3682 IPS MRCA PROG-D1 firmware.

Notes:
1. For output to built-in SMDR on RS-232C, one message is sent at intervals of one second unidirectionally.
For output to built-in SMDR on IP, one message is sent each time a request is received from SMDR terminal.
2. Output to built-in SMDR on RS-232C and output to built-in SMDR on IP cannot be performed at the same
time.
3. Built-in SMDR cannot be provided when SPN-AP00B MRC-C(AP) or earlier is used.

Page 36
PI-286
ISSUE 8

24. CALL INFORMATION SYSTEM (CIS)


DESCRIPTION SPECIFICATIONS

Type of Calls Applicable to SMDR Outgoing Call / Incoming Call / Tandem Call
Service
Number of CIS Printer Max. 2 printers per system

Number of CIS Control Terminals Max. 8 Dterm sets with LCD per system
(Dterm)
Max. Rate of Call Charge $0.00 to $999.99
per Station
Terminal Interface
„ Physical Interface RS-232C
„ Synchronization Asynchronous
„ Transmission Speed 300 / 1,200 / 2,400 / 4,800 bps
Type of Reports
„ Call Record This report provides detailed call information on a station or a station
group basis. Information included are;
• Calling Station Number
• Dialed Number
• Call Start Time
• Call Duration
• Call Charge
• Account Code
• Authorization Code
„ Totaled Call Charge This report provides a total amount of call charge on a station or a
station group basis.
Type of Output
„ Immediate Printout This allows an immediate printout of Call Record after completion of
each call.
„ Interim Report This report allows a display or a printout of Call Record or Totaled
Call Charge by the key operation from the CIS Control Terminal
(Dterm).
After display or printout, the information is still remained in the system.
„ Audit Report This report allows a display or a printout of Call Record or Totaled
Call Charge by the key operation from the CIS Control Terminal
(Dterm).
After display or printout, the information is deleted from the system.
Charging Method
„ H-Method Unit Time (call duration) is fixed, and Charging Rate per Unit Time
varies depending on the destination (area).
„ K-Method Charging Rate per Unit Time is fixed, and Unit Time varies depending
on the destination (area).
„ Flat Rate Fixed charge per call, regardless of call duration and destination.

„ Metering Pulse The system counts up the number of Metering Pulse from Central
Office, and calculates call charge on each call with the preprogrammed
charging rate per pulse.

Page 37
PI-286
ISSUE 8

DESCRIPTION SPECIFICATIONS

Buffer Memory Capacity Note 1


• Immediate Printout : Max. 1,000 Calls Note 2
• Interim Report
AP00-B without Expansion Memory : Max. 1,600 calls Note 2
AP00-B with Expansion Memory : Max. 12,000 Calls
Pseudo-Answer Timing for 8 to 40 sec. (programmable in 4-sec. increment)
Charging Start
Note 3
Charging to a Transferred Call The Following options are available by data programming;
(1) Split charging to both the transfers’ destination station and
transferring station.
(2) Charging to the final transfer destination.
(3) Charging to the first transfer destination station.

Notes:
1. The buffer memory capacity includes that for SMDR.
2. When the system is a center office of Centralized Billing in CCIS network, the buffer memory capacity is max.
800 calls.
3. In case of call transfer between an Attendant Console and a station, the charging is made to the station,
in any data programming.
4. SPN-AP00B MRC-E(AP) or later / SPN-AP00D MRC-B(AP) do not support the following features.
- PMS
- SMDR 1400IMS format
- Hotel Printer, CIS

Page 38
PI-286
ISSUE 8
25. PROPERTY MANAGEMENT SYSTEM (PMS) INTERFACE

Page 39
PI-286
ISSUE 8
26. MESSAGE CENTER INTERFACE (MCI)

Page 40
PI-286
ISSUE 8

27. OPTICAL FIBER INTERFACE (Production Discontinued)


DESCRIPTION SPECIFICATIONS

Output Port Max. 1 port per Card


(Optical Fiber Interface Port) Single Mode; IEC825-2 Class 1 compliant
Input Port Max. 2 T1 or E1 Ports per Card

Applications Remote PIM, Tie Line (T1/E1) Note

Note:
Tie line connections via optical modem are available between 2000 IPS systems.

28. VOICE MAIL SYSTEM (NEAXMail AD-8)


DESCRIPTION SPECIFICATIONS

Max. Number of Mailboxes Unlimited


Max. Number of Ports Basic: 4 ports / Option: 8 ports
Max. Storage Hours Approx. 200 hours
CPU 386SX / 33 MHz
RAM 4MB
Installation Built into PIM Card Slot
Power Supply Power feeding from AC – DC Power Unit in PIM
Dimensions (W x D x H; mm) Approx. 52.4 x 116.0 x 180.0
Weight (Kg) Approx. 0.55
Note 1
Voice Prompts Asia Model US English, UK English, Traditional Chinese, and Thai

North & Latin US English, Canadian French, Spanish, and Portuguese


America Model
Multi-lingual Capability Note 2 Yes (assigned on a port basis)
Multiple Voicemail Systems Networking Note 2 Yes
Note:
1. UK English, Traditional Chinese, and Thai prompts are available from AD-8 Revision 2 software.
2. Multi-lingual Capability and Multiple Voicemail System Networking features are available from AD-8 Revision
2 software.

Page 41
PI-286
ISSUE 8
29. IP TRUNK INTERFACE
FUNCTION SPECIFICATIONS NOTES

CODEC
G.729a Yes Reduce complexity of 8K CS-ACELP
G.723.1 Yes 5.3/6.3K MP-MLQ/ACELP
G.711 Yes 64K PCM
FAX FAX Relay based on T.30 G3 FAX
for CCIS Support V.17, V.29 and V.27ter
PBX Signaling
CCIS Note1 Yes (P-MP)
CCIS connected to Yes (P-MP)
FCCS Note 1
QSIG No
H.323 Client Note 2 Yes
Connection to H.323 Yes
Gatekeeper Note2
Dynamic Jitter Buffer Max. 300msec.
Ethernet Interface 10M/100M Ethernet
with RJ-45 connector
Number of IP Trunks Max. 8 Max. 1 IPT per Physical PIM
(Card-type IPT)
Number of Voice Channels Max. 127ch The number of IPT voice channels is
per System included in the condition of max. 256
trunks per system.
Number of Voice Channels Max. 16ch per IPT.
per IP Trunk Note3
QoS
TOS, IP Precedence Yes
Diffserv Yes (H.323 only)
Echo Canceller G.168 Roundtrip time: up to 32msec.
Modem Connection No
Tandem Connection
64K TDM Yes
TDM with Compression No
Notes:
1. CCIS signaling over IP are provided by either Virtual IP trunks (no hardware required) or IP trunk cards.
The Virtual IP trunks can be used when the distant office is 2000 IPS or 2400 IPX only.
(When the distant system is M100MX/2000IVS or 7400 ICS (IMX), the IP trunk cards are required.)
2. H.323 signaling requires IPT cards.
3. The number of Voice Channels per IP Trunk depends on the payload size as follows (payload size can be
assigned in system programming.):

Payload size CCIS (P-MP) H.323


G.729a G.711 G.723.1 G.729a G.711 G.723.1
10 ms 4ch 4ch --- --- --- ---
20 ms 8ch 8ch --- 6ch 5ch ---
30 ms 16ch 16ch 16ch 8ch 7ch 8ch
40 ms 16ch 16ch ---- 12ch 10ch ----

Page 42
PI-286
ISSUE 8
30. IP STATION INTERFACE
FUNCTION SPECIFICATIONS NOTES
PN-32IPLA-A(32ch) PN-8IPLA(8ch)
CODEC G.711/G.729a/G.723.1 G.711 (64Kbps)
G.7291 (8Kbps)
G.723.1 (5.3Kbps/6.3Kbps)
Dterm IP Signaling
PROTIMS Over IP Yes
H.323 with Gatekeeper No
Dynamic Jitter Buffer Max. 300msec.
Ethernet Interface 10M/100M Ethernet 100Mbps is recommended.
with RJ-45 connector
Number of IP Stations per Max. 956 The number depends on the
System system configuration.
Number of IP PADs Max. 8 Max. 2 IP PADs per FP Note 1.
per system
Number of Voice Channels 32ch. 8ch. Max.16ch. when using
per IP PAD (Max. 32ch G.723.1.
w/PZ-24IPLA)
Payload Size G.711: 10ms to 40ms (Default: 40ms) Can be assigned in system
G.729a: 10ms to 40ms (Default: 40ms) programming (10ms
G.723.1: 30ms (fixed) increment).
FAX T.30 G.711/G.726 Refer to APPENDIX D for
G.711/G.726 pass-through detailed conditions.
pass-through
Modem No G.711/G.726 G.711 pass through: 14.4k-24Kbps
pass-through G.726 pass through: 9.6k-14.4kbps
QoS
TOS, IP Precedence Yes
Diffserv Yes
Echo Canceller G.168 Roundtrip time: up to
64msec.
Modem Connection No
VLAN Note 2 Yes Yes
(IEEE 802.1Q (IEEE 802.1P
compliant) compliant)
System Registration Login/Logout with password, Login ID and password can
MAC address authentication be
encrypted.
Bandwidth Control Note 3 Yes

Notes:
1. The IP PADs are required for the following connections/statuses:
z Connections between Dterm IP stations and legacy stations/trunks
z Connections between Dterm IP stations and IP trunk cards (CCIS/H.323)
z CCIS connections via IP from/to legacy stations/trunks
z CCIS connections via IP with M100MX/2000IVS or 7400 ICS (IMX)
z While Dterm IP stations are on hold (Consultation Hold, Call Transfer, etc.)
z When any override service is activated (Executive Right of Way, etc.)
z Conference features (three/four-party, 6/10-party, 32-party) including Dterm IP stations

Page 43
PI-286
ISSUE 8
The IP PADs are not required for the following connections/statuses:
z Connections between Dterm IP stations
z Connections for CCIS networking via IP from/to Dterm IP stations
(Distant systems must be 2000 IPS or 2400 IPX)
2. VLAN feature is available from 3100 series software.
The VLAN ID can be assigned to MP, IP PAD, and Dterm IP telephones respectively.
Note that the multiple VLAN IDs cannot be assigned to each device.
3. Bandwidth Control feature is available from 3100 series software.

Page 44
PI-286
ISSUE 8
31. CENTRALIZED MAT
(1) PC Requirements

Ver.2 or earlier version


DESCRIPTION SPECIFICATIONS
Minimum Recommended
CPU Pentium 166MHz
RAM 64MB
Hard Disk Drive (HDD) 140MB or more Note1
Monitor SVGA (800 x 600) SVGA (1,024 x 768)
High Color (16-bit) High Color (16-bit)
Peripherals Sound board and speaker, CD-ROM Drive, Keyboard,
Mouse, LAN Interface card
Operating System (OS) Windows 95/98 (English version) Note2
Notes:
1. Centralized MAT uses 40MB. MATWorX uses 100MB.
2. Windows 95 must be OSR2 or later version.

Ver.3 or later version


DESCRIPTION SPECIFICATIONS
Minimum Recommended
CPU Pentium II 350MHz Pentium IV 1GHz
RAM 128MB 256MB
Hard Disk Drive (HDD) 280MB or more Note
Monitor SVGA (800 x 600) SVGA (1,024 x 768),
15-inch or larger monitor
High Color (16-bit) High Color (16-bit)
Peripherals Sound board and speaker, CD-ROM Drive, Keyboard,
Mouse, LAN Interface card
Operating System (OS) Windows Me/2000/XP/2003 (English version)
Notes: Centralized MAT uses 50MB. MATWorX uses 130MB.

(2) Version requirements for MATWorX and Centralized MAT

Centralized MAT version Version 2 or earlier Version 3 or later

MATWorX version
Version 10 or earlier OK NG

Version 11 or later NG OK

Page 45
PI-286
ISSUE 8

(3) PBX Requirements

DESCRIPTION SPECIFICATIONS
PBX requirements NEAX 2000 IPS, NEAX7400ICS M100MX/NEAX2000 IVS,
or M100MX Retrofit system Note1
(M100MX/2000IVS: Release 3.2 or later software version Note2)
Network Configuration CCIS network (including CCIS network via IP) Note3
Connection Note4 RS232C Interface or LAN connection
Number of offices Up to 255 offices per CCIS/IP network
Number of networks Up to 5 networks
Number of networks 5 networks Note5
for Fault Alarm Detection
Notes:
1. M100MX Retrofit system must be a local office.
2. This software version is required in each center and local office for M100MX/2000IVS systems..
The center office must have an Expansion Memory Card (PZ-M537) on a MP card.
3. Centralized MAT cannot supervise the network connected by Event based CCIS and IP with H.323
protocol.
4. Modem connection is not available.
5. The number of networks depends on the period as follows (period can be assigned in Centralized
MAT.):

Fault Alarm Detection Period Number of Network


30 seconds 1
1 minute 1
5 minutes 3
10 minutes 3
30 minutes 5
1 hour 5
12 hours 5
24 hours 5

Page 46
PI-286
ISSUE 8
32. REMOTE MAT (Production discontinued)
(1) PC Requirements

Refer to associated document of NEAX7400 IPX.

(2) PBX Requirements

DESCRIPTION SPECIFICATIONS
NEAX 2000 IPS / M80VS / M100
M100MX / 2000IVS
(incl. M100MX Retrofit system)
Required Software 2000IPS GD version or later
: All version
M100MX/2000IVS
: Release 2.1 or later
Number of remote offices Up to 1,000 offices GD version or earlier : Max.60 offices
J version or later : Max.540 offices
Interface condition RS232C (Serial port)
Connection Modem connection

Page 47
PI-286
ISSUE 8
33. Dterm ASSISTANT
(1) PC Requirements

<Dterm Assistant Server>


DESCRIPTION SPECIFICATIONS
Minimum Recommended
CPU Pentium II 350MHz or higher Pentium III 500MHz or higher
RAM Windows NT 4.0 Windows NT 4.0 / Windows 2000
256MB or more / XP
Windows 2000 / XP 512MB or more
256MB or more
Hard Disk Drive (HDD) 300MB or more (clean setup)
220MB or more (upgrade)
Peripherals Sound board and speaker, CD-ROM Drive, Keyboard,
Mouse, LAN Interface card
Note
Operating System (OS) Windows NT4.0 SP6 or later
Windows 2000 SP1 or later
Windows XP
Other Conditions HTTP port number is variable (default port number=80)
(R10 Dterm Assistant or later)
Note: The operating system must be English version.

<Dterm Assistant Client>


DESCRIPTION SPECIFICATIONS
Minimum Recommended
Note
Operating System (OS) Windows 98 SP1 or later
Windows NT4.0 SP6 or later
Windows 2000 SP1 or later
Windows ME
Windows XP
Browser Note Internet Explorer 5.5 SP2
Internet Explorer 6.0
Display 1,024 x 768 or higher resolution with 16-bit (65,536) colors or more
Peripherals Sound board and speaker, CD-ROM Drive, Keyboard,
Mouse, LAN Interface card
Other Conditions Dterm Assistant uses Java scripts and Java Applet.
Note: The software must be English version.

Page 48
PI-286
ISSUE 8
(2) System Capacity

DESCRIPTION SPECIFICATIONS

Number of users registered in the Max. 30,000


server
Number of users registered per Max. 1,000
PBX
Number of users logged in to the Max. 250 Note 1
server simultaneously
Number of user classes registered Max. 16 Note 2
in the server
Number of PBX systems registered Max. 64
in the server
Notes:
1. If a user logs in by opening two browsers with the same user ID, the Dterm Assistant system counts that two
users are logged in.
2. Three classes out of 16 are pre-defined by default. The other 13 classes can be assigned by the Server
Administrator Class.

Page 49
PI-286
ISSUE 8
34. IN-SKIN ROUTER (Production discontinued)
DESCRIPTION SPECIFICATIONS

CPU MPC860P 50MHz


Main memory 16MB, Max.32MB
Flash memory 4MB, Max.8MB
LAN interface 10BASE-T/100BASE-TX x1(main board), 10BASE-T x1(main board)
WAN interface 10BASE-T x1(PZ-M623), T1 x1(PZ-M649), E1 x1(PZ-M650)
Console interface MAT cable (RS232C)
IP IPv4/ IPv6
WAN protocol PPP/MP, Frame Relay, PPP over FR
Routing protocol Static, RIP (v1, v2)
Multicast IGMPv2
Router function DHCP server, DNS, NAT/NATe, DNS proxy, Tunneling
QoS Bandwidth control, Precedence
Security PAP/CHAP, Packet filtering, Caller ID control, Login password
VPN IPsec/IKE
Data compression Stac LZS
Host service TFTP client, Telnet server, FTP server, NTP
Data setting CLI (Console, Telnet)
Maintenance SNMP (Get only), Event Logging
Cooling method Air-cooling
EMC VCCI/FCC/EN Class A
Environment Temperature: 0-40 C Humidity: 20-90%Rh (non condensing)
Notes:
1. In-skin Router does not provide voice PAD control.
2. Maximum 8 main boards can be used per PIM, 64 cards per system.
3. This is available in Series 3000, 3100, 3200, 3300 or later software.
4. Network Address Translation (NAT) function is not available for IP telephones.

Page 50
PI-286
ISSUE 8
APPENDIX A: MTBF OF EACH CARD
CARD NAME FIT MTBF (YEARS)

PIM / MP / FP / POWER / PFT


PN-CP24-A (MP) 11,849 9.6
PN-CP26-A 11,585 9.9
(Retrofit MP for M100/M80VS)
PN-CP26-B 10,550 10.8
PN-CP24-B (MP) 10,798 10.6
PN-CP24-C (MP) 11,541 9.9
PN-CP24-D (MP) 10,550 10.8
PN-CP27-A 13,118 8.7
PN-CP27-B 10,750 10.6
PN-CP28-A 11,585 9.9
PN-CP28-B 10,650 10.7
PN-CP31-A 10,699 10.7
PN-CP31-B 11,085 10.3
PN-CP31-C 10,699 10.7
PN-CP31-D 10,120 11.3
PZ-M606-A (Ethernet Interface) 1,269 90.0
PN-CP15 (FP) 3,060 37.3
PN-CP17 2,958 38.6
(Retrofit FP doe M100/M80VS)
PN-PW00 (DC-DC; -48V) 1,960 58.2
PZ-PW121 (AC-DC) 13,850 8.2
PZ-PW122 (DC-DC; -48V) 5,780 19.8
PZ-PW135 144,789 0.8
PZ-8PFTB 1,439 79.3
SN1617 PIMMD (BWB) 1,868 61.1
LT CARDS
PN-2AMPA 2,076 42.2
PN-CFTA (6-Party Conference) 1,453 78.6
PN-CFTB (6-Party Conf. with Amp.) 941 121.3
PN-2COTD (Metering Pulse) 1,703 67.0
PN-2COTE 5,218 21.9
PN-4COTA-A (Loop Start) 1,243 91.8
PN-8COTQ (Caller ID) 2,968 38.5
PN-8COTR (Loop Start) 1,907 59.9
PN-2CSIA-A 5,420 21.1
PN-2CSIH 10,108 11.3
PN-4DATC 5,490 20.8
PN-2DITA (for Hong Kong) 661 172.7
PN-4DIDA 1,792 63.7
PN-4DITB 2,539 45.0
PN-DK00 1,274 89.6
PN-2DLCB (-48V) 1,581 72.2
PN-4DLCM 1,577 72.4
PN-4DLCQ 1,577 72.4
PN-4DLCT 1,293 88.3
PN-8DLCL 1,848 61.8
Page 51
PI-286
ISSUE 8
CARD NAME FIT MTBF (YEARS)

LT CARDS (Continued)
PN-8DLCP 1,848 61.8
PN-2DPCB 11,415 10.0
PN-2ILCA 5,849 19.5
PN-32IPLA 11,216 10.2
PN-32IPLA-A 11,112 10.3
PN-4LCC 1,367 83.5
PN-4LCD-A 1,961 58.2
PN-4LCK (for China) 1,375 83.0
PN-4LCL (for China) 1,752 65.2
PN-8LCAA 1,934 59.0
PN-8LCAK 1,226 93.1
PN-8LCAB (for China) 1,934 59.0
PN-8LCAD (for Caller ID) 2,174 52.5
PN-8LCAE (for Caller ID, China) 2,374 48.1
PN-2LDTA 1,546 73.8
PN-4LDTA 5,625 20.3
PN-4LLCB 1,792 63.7
PN-M03 (DPC V.35) 7,815 14.6
PN-M10 (Optical Modem) 1,750 65.2
PN-2ODTA 2,965 38.5
PN-4RSTF (Caller ID Sender) 699 163.3
PN-4RSTF-A 2,763 41.3
PN-8RSTG 133 858.3
PN-4VCTI (VoIP) 1,435 79.5
PN-16VCTA 2,674 42.7
PN-16VCTA-A 2,675 42.7
PZ-VM00-M (NEAXMail AD-8) 8,589 13.3
PZ-VM10-M (NEAXMail AD-8) 7,582 15.1
PZ-VM01/R (NEAXMail AD-8) 582 196.1
PN-4ODTA 5,625 20.3
PN-8IPLA 5,997 19.0
PZ-24IPLA 1,177 96.9
PN-8IPLA + PZ-24IPLA 7,174 15.9
PN-8IPTA (SIP Trunk) 5,997 19.0
PN-RTA + PZ-M650 5,492 20.9
PN-RTA + PZ-M623 3,470 32.9
PN-RTA + PZ-M649 5,792 19.7
PZ-VM02 19,103 6.0
AP CARDS
PN-AP00-B 5,196 22.0
PN-AP00-D 12,761 9.0
PN-BRTA 8,207 13.9
PN-2BRTC 4,124 27.7
PN-4BRTA-A 6,566 17.4
PN-24CCTA 4,625 24.7
PN-30CCTA 4,082 28.0
PN-CFTC (32-Party Conference) 6,000 19.0
PN-CFTC-A (32-Party Conference) 6,312 18.1

Page 52
PI-286
ISSUE 8
CARD NAME FIT MTBF (YEARS)

AP CARDS (Continued)
PN-DAIA (T1 Remote PIM; Main) 13,414 8.5
PN-DAIA-A (T1 Remote PIM; Main) 13,414 8.6
PN-DAIB (T1 Remote PIM; Remote) 13,356 8.5
PN-DAIC (T1 Remote PIM; Exp.) 8,941 12.8
PN-DAID (E1 Remote PIM; Main) 17,199 6.6
PN-DAID-A (E1 Remote PIM; Main) 17,199 6.6
PN-DAIE (E1 Remote PIM; Remote) 18,122 6.3
PN-DAIF (E1 Remote PIM; Exp.) 7,840 14.6
PN-24DTA-C 4,625 24.7
PN-30DTC-C 3,504 32.6
PN-DTA 4,213 27.1
PN-IPTB (VoIP) 5,757 19.8
PN-24PRTA 4,625 24.7
PN-30PRTA 4,082 28.0
PN-4RSTB (MFC) 5,607 20.4
PN-4RSTB-A (MFC) 5,733 19.9
PN-4RSTC (Caller ID Receiver) 12,349 9.2
PN-4RSTC-A (Caller ID Receiver) 16,301 7.0
PN-SC00 (CCH) 8,816 12.9
PN-SC01 (DCH) 8,188 13.9
PN-SC03-B (ICH/CSH) 6,816 16.8
PN-SC03-C (CSH) 8,224 13.9
PN-2ILCC 13,754 8.3

Page 53
PI-286
ISSUE 8
APPENDIX B: CURRENT CONSUMPTION OF EACH CARD
CARD NAME DC Current Consumption (mA)
(at –27V)
MP / FP / POWER / PFT
PN-CP24-A (MP) 430
PZ-M606-A (Ethernet Interface)
PN-CP26-A (Retrofit MP) 321
PZ-M606-A (Ethernet Interface)
PN-CP26-B (Retrofit MP) 252
PN-CP26-B (with PZ-M606-A) 311
PN-CP24-B 316
PN-CP24-B (with PZ-M606-A) 365
PN-CP24-C 249
PN-CP24-C (with PZ-M606-A) 316
PN-CP24-D 264
PN-CP24-D (with PZ-M606-A) 321
PN-CP27-A 430
PN-CP27-B 264
PN-CP27-B (with PZ-M606-A) 321
PN-CP28-A 333
PN-CP28-B 267
PN-CP28-B (with PZ-M606-A) 328
PN-CP31-A (with PZ-M606-A) 314
PN-CP31-B 304
PN-CP31B (with PZ-M606-A) 368
PN-CP31-C 257
PN-CP31-C (with PZ-M606-A) 291
PN-CP31-D 264
PN-CP31-D (with PZ-M606-A) 321
PN-CP15 (FP) 133
PN-CP17 (Retrofit FP) 73
PN-PW00 (DC-DC; -48V) 800
PZ-PW122 (DC-DC: -48V) 3,600
PZ-8PFTB 140
LT CARDS
PN-2AMPA 43
PN-CFTA (6-Party Conference) 31
PN-CFTB (6-Party Conf. with Amp.) 60
PN-2COTD (Metering Pulse) 122
PN-2COTE 168
PN-4COTA-A (Loop Start) 144
PN-8COTQ (Caller ID) 161
PN-8COTR (Loop Start) 146
PN-2CSIA-A 23
PN-2CSIH 76
PN-4DATC 19
PN-2DITA (for Hong Kong) 261
PN-4DIDA 433
PN-4DITB 347
PN-DK00 81
Page 54
PI-286
ISSUE 8
CARD NAME DC Current Consumption (mA)
(at –27V)
LT CARDS (Continued)
PN-2DLCB (-48V) 230
PN-4DLCM 250
PN-4DLCQ 250
PN-4DLCT 488
PN-8DLCL 515
PN-8DLCP 515
PN-2DPCB 94
PN-2ILCA 55
PN-32IPLA 455
PN-32IPLA-A 388
PN-4LCC 181
PN-4LCD-A 269
PN-4LCK (for China) 223
PN-4LCL (for China) 439
PN-8LCAA 453
PN-8LCAK 324
PN-8LCAB (for China) 451
PN-8LCAD (for caller ID) 249
PN-8LCAE (for caller ID, China) 294
PN-2LDTA 256
PN-4LDTA 442
PN-4LLCB 329
PN-M03 (DPC V.35) 107
PN-M10 (Optical Modem) 85
PN-2ODTA 121
PN-4RSTF (Caller ID Sender) 77
PN-4RSTF-A 10
PN-8RSTG 50
PN-4VCTI (VoIP) 138
PN-16VCTA 163
PN-16VCTA-A 151
NEAXMail AD-8(PZ-VM00-M + VM01/R) 507
NEAXMail AD-8(PZ-VM10-M + VM01/R) 507
PN-4ODTA (E&M Type-I) 1,314
PN-4ODTA 85
PN-8IPLA 167
PN-8IPLA + PZ-24IPLA 212
PN-RTA + PZ-M650 178
PN-RTA + PZ-M623 176
PN-RTA + PZ-M649 210
PZ-VM02 (including HD) 1,240
AP CARDS
PN-AP00-B 96
PN-AP00-D 128
PN-BRTA 51
PN-2BRTC 79
PN-4BRTA-A 160
PN-24CCTA 132

Page 55
PI-286
ISSUE 8
CARD NAME DC Current Consumption (mA)
(at –27V)
AP CARDS (Continued)
PN-30CCTA 96
PN-CFTC (32-Party Conference) 70
PN-CFTC-A (32-Party Conference) 146
PN-DAIA (T1 Remote PIM; Main) 132
PN-DAIA-A (T1 Remote PIM; Main) 132
PN-DAIB (T1 Remote PIM; Remote) 122
PN-DAIC (T1 Remote PIM; Exp.) 59
PN-DAID (E1 Remote PIM; Main) 116
PN-DAID-A (E1 Remote PIM; Main) 116
PN-DAIE (E1 Remote PIM; Remote) 111
PN-DAIF (E1 Remote PIM; Exp.) 57
PN-24DTA-C 123
PN-30DTC-C 81
PN-DTA 128
PN-IPTB (VoIP) 442
PN-24PRTA 132
PN-30PRTA 96
PN-4RSTB (MFC) 27
PN-4RSTB-A (MFC) 102
PN-4RSTC (Caller ID Receiver) 57
PN-4RSTC-A (Caller ID Receiver) 112
PN-SC00 (CCH) 49
PN-SC01 (DCH) 44
PN-SC03-B (CSH) 73
PN-SC03-C (CSH) 170
PN-2ILCC 163

Page 56
PI-286
ISSUE 8
APPENDIX C: PORT ALLOCATION

(1) General

DESCRIPTION SPECIFICATIONS NOTES


Number of Ports for LT Cards
Max. 512 ports per system Including Dterm IP Telephones
Max. 64 ports per PIM
Number of Ports for AP Cards
- Basic AP Port (Basic HW) Max. 128 ports per system
- Expanded AP Port (Expanded HW) Max. 128 ports per system

Port Allocation of Time Division Switch

128 ports per FP 64 ports


64 ports
128 ports per FP 64 ports User for LT Cards and Dterm IP Telephones
64 ports (64 ports per PIM, 512 ports per system)
128 ports per FP 64 ports
64 ports
128 ports per FP 64 ports
64 ports
128 ports Used for AP Cards
(256 ports per system)
128 ports 3-way Conference, Music on Hold, Built-in Modem,
DAT, DTMF Sender/Receiver, Audible Tone (DTG), DK
128 ports

128 ports Not Used

Page 57
PI-286
ISSUE 8
(2) LT Cards

CARD NAME NUMBER OF PORTS


PER CARD
PN-2AMPA 4
PN-CFTA (6-Party Conference) 10
PN-CFTB (6-Party Conf. with Amp.) 10
PN-2COTD (Metering Pulse) 2
PN-2COTE (Metering Pulse) 2
PN-4COTA-A (Loop Start) 4
PN-4COTG (Caller ID) 4
PN-8COTQ (Caller ID) 8
PN-8COTR (Loop Start) 8
PN-2CSIA-A 8
PN-2CSIH 8
PN-4DATC 8
PN-2DITA (for Hong Kong) 2
PN-4DITB 4
PN-4DIDA 4
PN-DK00 0
PN-2DLCB (-48V) 2
PN-4DLCM 4
PN-4DLCQ 4
PN-4DLCT (-48V) 4
PN-8DLCL 8
PN-8DLCP 8
PN-2DPCB 4
PN-2ILCA 8
PN-32IPLA / PN-32IPLA-A 32
PN-4LCC 4
PN-4LCD-A 4
PN-4LCK (for China) 4
PN-4LCL (for China) 4
PN-8LCAA 8
PN-8LCAK 8
PN-8LCAB (for China) 8
PN-8LCAD (for caller ID) 8
PN-8LCAE (for caller ID, China) 8
PN-2LDTA 2
PN-4LDTA 4
PN-4LLCB 4
PN-M03 (DPC V.35) 0
PN-M10 (Optical Modem) 0
PN-2ODTA 2
PN-4RSTF (Caller ID Sender) 4
PN-4RSTF-A (Caller ID Sender) 4
PN-8RSTG 8
PN-4VCTI (VoIP) 4
PN-16VCTA / PN-16VCTA-A 0
PZ-VM00-M (NEAXMail AD-8) 8
PZ-VM10-M (NEAXMail AD-8) 8

Page 58
PI-286
ISSUE 8
CARD NAME NUMBER OF PORTS
PER CARD
PN-VM01/R (NEAXMail AD-8) 0
PN-4ODTA 4
PN-8IPLA 8
PZ-24IPLA 24
PN-8IPTA (SIP Trunk) 8
PZ-VM02 0

Page 59
PI-286
ISSUE 8
(3) AP Cards

X: Available ==: Not Available


CARD NAME NUMBER OF PORTS AP HIGHWAY
PER CARD
Basic HW Expanded HW
(128 time slots) (128 time slots)
PN-AP00-B 2 X ==
PN-AP00-D 2 X ===
PN-BRTA 2 X ==
PN-2BRTC 4 X ==
PN-4BRTA-A 8 X X
PN-24CCTA 25 X X
PN-DTA (CCT-24ch) 25 X X
PN-30CCTA 32 X X
PN-DTA (CCT-30ch) 32 X X
PN-CFTC 32 X X
PN-CFTC-A 32 X X
PN-DAIA (T1 Remote PIM; Main) 0 == ==
PN-DAIA-A (T1 Remote PIM; Main) 0 == ==
PN-DAIB (T1 Remote PIM; Remote) 0 == ==
PN-DAIC (T1 Remote PIM; Exp.) 0 == ==
PN-DAID (E1 Remote PIM; Main) 0 == ==
PN-DAID-A (E1 Remote PIM; Main) 0 == ==
PN-DAIE (E1 Remote PIM; Remote) 0 == ==
PN-DAIF (E1 Remote PIM; Exp.) 0 == ==
PN-24DTA-C 24 X X
PN-DTA (T1) 24 X X
PN-30DTC-C 31 X X
PN-DTA (E1) 31 X X
PN-IPTB (VoIP) 0 == ==
PN-24PRTA 25 X X
PN-DTA (PRT-24ch) 25 X X
PN-30PRTA 32 X X
PN-DTA (PRT-30ch) 32 X X
PN-4RSTB (MFC) 4 X ==
PN-4RSTB-A (MFC) 4 X ==
PN-4RSTC (Caller ID Receiver) 4 X ==
PN-4RSTC-A (Caller ID Receiver) 4 X ==
PN-SC00 (CCH) 1 X ==
PN-DTA (Event Based CCIS) 1 X ===
PN-SC01 (DCH) 1 X ==
PN-SC03-B (CSH) 4 X ==
PN-SC03-C (CSH) 4 X ==
PN-2ILCC 8 X ==

Page 60
PI-286
ISSUE 8

APPENDIX D: Conditions of 32IP PAD and 8IP PAD


From the 3300 Series R8, two types of IP PAD are available with the conditions shown in the table below.
According to these conditions, the IP PAD channel expansion and network node expansion should be
performed.

Combination of IP PAD and Software Version


X: Available / -: Not Available
IP PAD 3200 R6.2 or former 3300 R8 or later
32IP PAD X X
8IP PAD - X

FAX over IP Protocol


X: Available / -: Not Available
IP PAD T.30 G.711 Pass-through G.726 Pass-through
32IP PAD PN-32IPLA-A (SC-3353)+ X X X
(w/VCT) PN-16VCTA-A (SP-3815) (R6.2 or later) (R8 or later) (R9 or later)
32IP PAD PN-32IPLA-A (SC-3353) --- X ---
(w/o VCT) (R9 or later)
8IP PAD PN-8IPLA (SC-3213) --- X ---
(R8 or later)
PN-8IPLA (SC-3386) --- X X
(R8 or later) (R8 or later)

Connectivity of FAX over IP


IPS IPS IPS IPS IPX IPX MC
8IPLA 32IPLA 32IPLA IPT IPPAD IPPAD
(w/ VCT) (w/o VCT) (w/ VCT) (w/o VCT)
IPS G.711/G.726 G.711/G.726 G.711 Not G.711/G.726 G.711 G.711/G.726
8IPLA pass-through pass-through pass-through available pass-through pass-through pass-through

IPS G.711/G.726 G.711/G.726 G.711 Not G.711/G.726 G.711 G.711/G.726


32IPLA pass-through pass-through pass-through available pass-through pass-through pass-through
(w/VCT) T.30 T.30 T.30
IPS G.711 G.711 G.711 Not G.711 G.711 G.711
32IPLA pass-through pass-through pass-through available pass-through pass-through pass-through
(w/o VCT)
8IPLA: PN-8IPLA with SC-3386, 32IPLA: PN-32IPLA-A with SC-3353, VCT: PN-16VCTA-A with SP-3815

Page 61
PI-286
ISSUE 8

Required bandwidth for FAX Connection


IP PAD Connection Conditions Required Bandwidth (One-way)
32IPLA-A/ T.30, G.711, Payload=40ms 150 kbps (estimated)
16VCTA-A T.30, G.729a, Payload=40ms 23.6 kbps (FAX Payload=78 byte)
Communication speed=14.4kbps
(No IP Header compression in Router)
T.30, G.729a, Payload=40ms 16.6 kbps (FAX Payload=78 byte)
Communication speed=14.4kbps
(with IP Header compression in Router)
8IPLA/ G.711 pass-through, Payload=40ms 72 kbps (FAX Payload=320 byte)
24IPLA (No IP Header compression in Router)
G.711 pass-through, Payload=40ms 65 kbps (FAX Payload=320 byte)
(with IP Header compression in Router)
G.726 pass-through, Payload=40ms 40 kbps (FAX Payload=160 byte)
(No IP Header compression in Router)
G.726 pass-through, Payload=40ms 33 kbps (FAX Payload=160 byte)
(with IP Header compression in Router)
Note: This data does not include MAC Header.