(1) Digital Announcement Trunk (DAT)................................................................................................30
(2) Service Capacity ..............................................................................................................................30
22. DATA COMMUNICATIONS ...................................................................................................31
Analog Port Adapter (APR)...................................................................................................................31
23. STATION MESSAGE DETAIL RECORDING (SMDR) .......................................................32
(1) SMDR TERMINAL INTERFACE .................................................................................................32
(2) SMDR OUTPUT FORMAT..............................................................................................................35
24. CALL INFORMATION SYSTEM (CIS) .................................................................................37
25. PROPERTY MANAGEMENT SYSTEM (PMS) INTERFACE .............................................39
26. MESSAGE CENTER INTERFACE (MCI) ............................................................................40
27. OPTICAL FIBER INTERFACE (Production Discontinued) .................................................41
28. VOICE MAIL SYSTEM (NEAXMail AD-8) ...........................................................................41
29. IP TRUNK INTERFACE ........................................................................................................42
30. IP STATION INTERFACE .....................................................................................................43
31. CENTRALIZED MAT..............................................................................................................45
(1) PC Requirements.............................................................................................................................45
(2) Version requirements for MATWorX and Centralized MAT .........................................................45
(3) PBX Requirements...........................................................................................................................46
32. REMOTE MAT .......................................................................................................................47
(1) PC Requirements.............................................................................................................................47
(2) PBX Requirements...........................................................................................................................47
33. Dterm ASSISTANT ...................................................................................................................48
(1) PC Requirements.............................................................................................................................48
(2) System Capacity ..............................................................................................................................49
34. IN-SKIN ROUTER (Production discontinued) ......................................................................50
APPENDIX A: MTBF OF EACH CARD .....................................................................................51
APPENDIX B: CURRENT CONSUMPTION OF EACH CARD ................................................54
APPENDIX C: PORT ALLOCATION...........................................................................................57
(1) General .........................................................................................................................................57
(2) LT Cards ......................................................................................................................................58
(3) AP Cards......................................................................................................................................60
APPENDIX D: Conditions of 32IP PAD and 8IP PAD.............................................................61
Page 5
PI-286
ISSUE 8
1. SYSTEM CAPACITY (Standalone system, 3800 series R13)
This table shows the maximum number of each item in a standalone system (with single MP).
System Capacity Note 1,2
Item
1PIM 2PIM 3PIM 4PIM 5PIM 6PIM 7PIM 8PIM
(No. of Ports) 64 128 192 256 320 384 448 512
LT Card
(No. of Cards) 12 24 36 48 60 72 84 96
(No. of Ports) Max. 256 ports per system
AP Card
(No. of Cards) 12 24
Total Number of Lines 64 128 192 256 320 384 448 512
(Analog Single Line Tel. + Dterm)
IP PAD (No. of Channel) 64 128 192 256
Note 9 (2 cards) (4 cards) (6 cards) (8 cards)
Analog Single Line Telephone Standard 64 128 192 256 320 384 448 512
(Lines) Long Note 5 48 96 144 192 240 288 336 384
Dterm (Lines) Standard 64 128 192 256 320 384 448 512
Long 24 48 72 96 120 144 168 192
Dterm IP/Dterm IP INASET/Dterm SP30 956 892 828 764 700 636 572 508
(Peer to Peer Connection)
Dterm PS (Australia/Asia) 512 Note 6
/ Dterm PSII / III (USA/LA)
WLAN Handset (MH250) 128
Dterm PS + WLAN Handset 512
Cell Station (CS) / Zone Transceiver (ZT) 16 32 48 64 80 96 112 128
24 32
P-P Connection (24) (32)
ISDN Station (2ILCC)
( ): Simultaneous Connection 192 256
P-MP Connection (48) (64)
Loop Start 64 128 192 256
Central Office Trunk (Lines)
DID w/4DIT 48 96 144 192 240 256
4LDT 48 96 144 192 240 256
Tie Line Trunk (Lines) 2W or 4W E&M 48 96 144 192 240 256 256 256
(4ODTA) (12) (24) (36) (48) (60) (72) (84) (96)
( ): Type I w/ PW122
CCIS Trunk (Peer to Peer Connection) Note10 Max. 127
1.5M-AMI DTI: 10, CCIS: 8
DTI/CCIS Digital Link Note 1
2M-AMI Max. 8 Links per system
1.5/2M-AMI
8
(PRT)
ISDN Trunk 2BRT (card)
(Production discontinued)
12 24
4BRT (card) 6 12 18 24 24 24 24 24
IP Trunk Note 3 1 2 3 4 5 6 7 8
PFT Connections 8PFT 8 16 24 32 40 48 56 64
3-Party Conference Max. 16 conference groups per system
6/10-Party Conference 6-Party Max. 4 conference groups per system
(Production discontinued) 10-Party Max. 2 conference groups per system
8-Party Conference Max. 8 conference group per system
32-Party Conference Max. 8 conference group per system
Page 6
PI-286
ISSUE 8
System Capacity (Standalone, Single MP System, Cont’d)
System Capacity
Item
1PIM 2PIM 3PIM 4PIM 5PIM 6PIM 7PIM 8PIM
In-skin Router (Production discontinued) Max. 8 cards per PIM
In-skin SIP Handler 1
Built-in Voice Mail (VM10) 1
DTMF Sender Max. 32 circuits per system
DTMF Receiver 16 32
SN716 Desk Console 8
SN708 Digital Console (Australia)
(Production discontinued)
8
SN709/712/741 Smart Console
(Production discontinued)
8
term
Attendant Terminal (D ATT Position) Max. 8 sets per system
Max. 2 interface ports per system (RS-232C)
SMDR Interface
Max. 1 port per system (IP)
PMS Interface Max. 1 interface port per system (RS-232C or IP)
ACD / MIS or OAI Interface Note 4 Max. 1 interface port per system (IP)
Remote PIM over IP (Number of Sites) 30 (depending on network configurations)
DID Dial Conversion 1,000
Call Forwarding-Outside Set 496
Authorization Code / Forced Account Code
3,000
/ Remote Access to System (DISA) Code
Message Reminder Set 1,024
Name Display / Guest Name Display 512
Speed Calling-Station (Station Speed Dial) Set 10,000
MP built-in SMDR Call Record 1,024
Note 1: The total number of trunk line and DTI channel shall be 256 or less.
(Each trunk line and DTI channel are required to assign the “Trunk Number” by system data programming
and maximum number of system parameter for “Trunk Number” is 256.)
Note 2: "PIM" in this table means "Physical PIM."
Page 7
PI-286
ISSUE 8
Note 3: Maximum voice channels per IP trunk card depends on the payload size as follows (payload size can
be assigned by system data programming):
CCIS (p-p/p-mp)
VoIP (H.323)
Note 5: Message Waiting Lamp is not available when the 4LLC is mounted in slot 08 to 11.
Note 6: From 3300 Series R8, maximum 256 PS can be accommodated to the system in addition to the
maximum 512 LT ports.
Ex: 400 Dterms+100 CO Lines=500 LT Ports
Total 600 Ports available
100 PSs
From 3400 Series R9, maximum 512 PS can be accommodated to the system.
The system provides up to 1020 ports (= LT port(max.512) + IP port(max.956) + PS port(max.512).
Page 8
PI-286
ISSUE 8
Note 8: Maximum number of voice channels per IP PAD card depends on the payload size as follows.
32IPLA+16VCTA
Payload Size Maximum Voice Channels per IP PAD
(32IPLA+16VCTA)
G.711 G.729a G.723.1
10ms 12 12 -
20ms 20 20 -
30ms 30 30 24
40ms 32 32 -
8IPLA+24IPLA
Payload Size Maximum Voice Channels per IP PAD
(8IPLA+24IPLA)
G.711 G.729a G.723.1
10ms 20 20 -
20ms 32 32 -
30ms 32 32 24
40ms 32 32 -
PN-8IPLA should be 3A or later version. SP-3213 IPS IPADT PROG-A1 should be 2A or later version.
Note 10: The number of P2P-CCIS trunk is calculated in terms of IP ports. In R8 and earlier release,
P2P-CCIS can be created in additional to TDM ports and IP ports. From 3400 series R9, there
are included in the IP ports (Max. 956).
In R8 and earlier release,
IP ports (Max.448) = DtermIP (Max.448 ports)
In R9 release,
IP ports (Max.956) = DtermIP (Max.956 ports) + P2P-CCIS (Max.127 ports)
Page 9
PI-286
ISSUE 8
2. NUMBERING PLAN
DESCRIPTION NUMBERING PLAN Note 1
Note 2
Station Access Max. 8 digits
Network Station Access Max. 8 digits Note 3
Attendant Access Max. 4 digits
Central Office Trunk Access Max. 4 digits
Tie Line Trunk Access Max. 4 digits
Miscellaneous Trunk Access Max. 4 digits
Service Feature Access Max. 4 digits
Notes:
1. Leading digit must be different.
2.
(1) When AP00 card with AP00 program is used (SMDR, Hotel/PMS, CIS Printer, MCI), station number must be
assigned up to 4 digits. (5-digit station number is available when the leading digit is a fixed number.)
(2) When AP00 card with MRCA program or MP built-in SMDR/PMS is used, station number must be assigned
up to 6 digits.
3. Closed numbering is used when 2000 IPS is connected with a FCCS network via CCIS.
3. CLASS OF SERVICE
CLASS OF SERVICE DESCRIPTION
Telephone Class There are 7 telephone classes depending on the type of telephone set:
(1) Single Line Telephone (DP, DTMF, DP/DTMF)
(2) Dterm
(3) House Phone
(4) Hot Line
(5) Automatic Intercom
(6) Dial Intercom
(7) Manual Intercom
Tenant Class Max. 64 tenant classes are available.
Trunk Restriction Class There are 8 trunk restriction classes as shown below:
(1) Unrestricted
(2) Non-restricted (1, 2)
(3) Semi-restricted (1, 2)
(4) Restricted (1, 2)
(5) Fully restricted
Service Restriction Class Max. 16 service feature classes are available for access to service
features.
Page 10
PI-286
ISSUE 8
4. CONTROL SYSTEM
DESCRIPTION SPECIFICATIONS
6. TRAFFIC CAPACITY
DESCRIPTION SPECIFICATIONS
Page 11
PI-286
ISSUE 8
7. PRODUCT RELIABILITY DATA
Following figures indicate the possibility of a part of system failure.
PIM3 PIM4
<Dual CPU Switching Configuration>
CP27-B M606-A
(10750) (1269)
PW121 8IPLA+24IPLA PW121 CP15 PW121
(13850) (7174) (13850) (3060) (13850)
CP27-B M606-A
(10750) (1269)
PIM3 PIM4
Refer to APPENDIX A for MTBF of each card.
Page 12
PI-286
ISSUE 8
8. POWER REQUIREMENTS
(1) AC Input System
AC Power Requirements
DESCRIPTION SPECIFICATIONS
Battery Requirements
DESCRIPTION SPECIFICATIONS
Page 13
PI-286
ISSUE 8
(2) DC Input System
DC Power Requirements
DESCRIPTION SPECIFICATIONS
Battery Requirements
9. OPEARTING ENVIRONMENT
DESCRIPTION SPECIFICATIONS
Page 14
PI-286
ISSUE 8
10. ELECTRICAL CHARACTERISTICS (CENTRAL OFFICE TRUNK)
System for Asia/Latin America/Middle East/Africa/Russia
DESCRIPTION SPECIFICATIONS
Page 15
PI-286
ISSUE 8
11. TRANSMISSION CHARACTERISTICS
System for Asia/Latin America/Middle East/Africa/Russia
DESCRIPTION SPECIFICATIONS
Page 16
PI-286
ISSUE 8
12. LINE CONDITIONS
DESCRIPTION SPECIFICATIONS
Page 17
PI-286
ISSUE 8
DESCRIPTION SPECIFICATIONS
Receiving Sending
Dial Speed 9 to 22 pps 10 pps +/- 0.8pps
20 pps +/- 0.8 pps
Break Ratio 55 to 77 % 67 +/- 3% or 62 +/- 3%
Inter-Digit Pause Min. 256 msec. 300 to 1,000 msec.(10 pps)
Switch-Hook Flash Detection 384 to 2,300 msec. Not applicable
DESCRIPTION SPECIFICATIONS
Receiving Sending
Signal Code
High Frequency Group 1,209Hz 1,336Hz 1,477Hz
Low Frequency Group 697Hz 1 2 3
770Hz 4 5 6
852Hz 7 8 9
941Hz * 0 #
Page 18
PI-286
ISSUE 8
14. MULTIFREQUENCY COMPELLED (MFC) – R2 SIGNAL
(1) MFC Frequency Value
FREQUENCIES FORWARD SIGNALS(Hz) BACKWARD SIGNALS(Hz)
F0 1,380 1,140
F1 1,500 1,020
F2 1,620 900
F3 1,740 780
F4 1,860 660
F5 1,980 540
1 F0 + F1
2 F0 + F2
3 F1 + F2
4 F0 + F3
5 F1 + F3
6 F2 + F3
7 F0 + F4
8 F1 + F4
9 F2 + F4
10 F3 + F4
11 F0 + F5
12 F1 + F5
13 F2 + F5
14 F3 + F5
15 F4 + F5
Frequency 20 or 25Hz
Voltage 75 or 90Vrms
The 2000 IPS has the capability to detect the above type of signal from Central Office and to transmit the
above type of signal to PBX stations.
Page 19
PI-286
ISSUE 8
16. DIMENSION AND WEIGHT
DESCRIPTION SPECIFICATIONS
DIMENSIONS (W x D x H; mm) WEIGHT (kg)
Main Equipment
PIM (Fully card-mounted) Approx. 430 x 223 x 353 Approx. 11.5
BASE Approx. 430 x 205.2 x 61.6 Approx. 3.0
BASE TRAY (for UL) Approx. 435 x 224.6 x 66.2 Approx. 1.7
Dterm 75 Series
Dterm 8 Approx. 177 x 224 x 76 Approx. 1.0
Dterm 8D Approx. 177 x 229 x 98 Approx. 1.1
Dterm 16D Approx. 177 x 229 x 98 Approx. 1.1
Dterm 32D Approx. 201 x 229 x 98 Approx. 1.1
DSS Console Approx. 177 x 218 x 74 Approx. 0.7
term
D Series i
Dterm 2DT Approx. 165 x 221 x 92 Approx. 0.9
Dterm 4D Approx. 215 x 193 x 142 Approx. 0.9
Dterm 8 Approx. 231 x 217 x 106 Approx. 1.1
Dterm 8D Approx. 231 x 217 x 106 Approx. 1.2
Dterm 16D Approx. 231 x 217 x 106 Approx. 1.2
Dterm 16LD Approx. 232 x 252 x 106 Approx. 1.35
Dterm 32D Approx. 232 x 243 x 106 Approx. 1.3
DSS Console Approx. 175 x 216.3 x 92 Approx. 0.6
Dterm Series i (Russian display model)
Dterm 8D-R Approx. 175 x 226 x 96 Approx. 0.8
term
D 16D-R Approx. 175 x 226 x 96 Approx. 0.8
Dterm 32D-R Approx. 193 x 226 x 96 Approx. 0.9
Attendant Console
SN709/712/741 Smart Console Approx. 264 x 230 x 110 Approx. 1.3
(Production discontinued)
SN716 Desk Console Approx. 277 x 258 x 132 Approx. 1.4
Page 20
PI-286
ISSUE 8
17. Dterm 75 SERIES DIGITAL TERMINALS (Production Discontinued)
DESCRIPTION SPECIFICATIONS
Dterm 8 Dterm 8D Dterm 16D Dterm 32D
Max. Number of Line 8* 8* 16* 32*
/Programmable Feature Keys
Number of Dedicated Feature Keys 11 11 11 11
Speaker YES YES YES YES
Answer YES YES YES YES
Hold YES YES YES YES
Transfer YES YES YES YES
Recall YES YES YES YES
Conference YES YES YES YES
Redial YES YES YES YES
Feature YES YES YES YES
Volume Control YES YES YES YES
Number of Soft Keys NO 4 4 4
Accessories
Headset Jack Connecter Built-in Built-in Built-in Built-in
Note 2
Page 21
PI-286
ISSUE 8
Notes:
1. One of below languages is assigned in system basis.
English
Spanish
Portuguese
French
2. Plantronics Supra-NC Polaris (Product Code: P51N-U 10P) is recommended.
3. It requires an AC/DC adapter.
4. A Dterm can equip only one out of following three adapters at the same time :
- Analog Port Adapter (APR)
- CTI Adapter (CTA)
- IP Adapter (IPW)
5. A Wall Mount Unit is required when the Dterm set with an optional adapter is wall-mounted. The Dterm set
without an optional adapter can be wall-mounted without the Wall Mount Unit.
6. Cable length is based on the cable with 0.5mm diameter and without lightning arresters.
Page 22
PI-286
ISSUE 8
18. Dterm Series i (Standard Model)
DESCRIPTION SPECIFICATIONS
term term term term term term term
D 2DT D 4D D 8 D 8D D 16D D 32D D 16LD
Note 9 Note 9
*
Max. Number of Line 2 4 8* 8* 16* 32 16
/Programmable Feature Keys (with LED) (with LED) (with LED) (with LED) (with LED) (with LED) (with LCD)
Number of Dedicated Feature Keys 9 9 11 11 11 11 11
Speaker YES YES YES YES YES YES YES
Answer YES YES YES YES YES YES YES
Hold YES YES YES YES YES YES YES
Transfer YES YES YES YES YES YES YES
Recall YES YES YES YES YES YES YES
Conference YES YES YES YES YES YES YES
Redial YES YES YES YES YES YES YES
Feature YES YES YES YES YES YES YES
MIC YES YES YES YES YES YES YES
Directory NO NO YES YES YES YES YES
Message NO NO YES YES YES YES YES
Volume Control Keys YES YES YES YES YES YES YES
Number of Soft Keys NO 4 NO 4 4 4 4
Indicator on Line/Feature Keys LED LED LED LED LED LED LCD icon
NOTE 7
Green/Red Green/Red Green/Red Green/Red Green/Red Green/Red
LCD Display NO 24 x 3 NO 24 x 3 24 x 3 24 x 3 24 x 3
(Number of Characters x Lines)
Multilanguage display on 24 x 3 LCD Note 1 NO 12 language 12 language 12 language 12 language 12 language 12 language
Call Indicator LED YES YES YES YES YES YES YES
/Message Waiting LED
Accessories
Note 2
Headset Jack Connecter NO NO Built-in Built-in Built-in Built-in Built-in
Hands-Free Unit Built-in Built-in Built-in Built-in Built-in Built-in Built-in
DSS/BLF Console Note 3 Option Option Option Option Option Option Option
Note8
16LD ADM NO NO NO NO NO NO Option
Ancillary Device Adapter (ADA) NO NO Option Option Option Option Option
Note 3,4
Analog Port Adapter (APR) NO NO Option Option Option Option Option
Note 3,4
CT Adapter (CTA) NO NO Option Option Option Option Option
Note 3,4
IP Adapter (IPW) NO NO NO Option Option Option Option
Note 5
Wall Mount Unit NO NO Option Option Option Option Option
AC Adapter NO NO Option Option Option Option Option
Analog Data Port YES NO NO NO NO NO NO
(for modem connection, outgoing call only)
Cabling 1-Pair 1-Pair 1-Pair 1-Pair 1-Pair 1-Pair 1-Pair
Max. Cable Length Note 6
8DLC/4DLC Card 300m 300m 300m 300m 300m 200m 300m
2DLC Card 850 850m 850m 850m 850m 850m 850m
4DLC/2DLC Card with AC Adapter NO NO 1,200m 1,200m 1,200m 1,200m 1,200m
Color White / Black White / Black White / White / Black White / Black White / Black
Black Black
Page 23
PI-286
ISSUE 8
Notes:
1. One of below languages is assigned in system basis (R10 o earlier software).
One of below language can be assigned per terminal basis (R11 or later software).
- Danish
- Dutch
- English
- French (Canadian)
- French (European)
- German
- Italian
- Portuguese (Brazilian)
- Portuguese (European)
- Spanish (Latin)
- Spanish (European)
- Swedish
2. Plantronics Supra-NC Polaris (Product Code: P51N-U 10P) is recommended.
3. It requires an AC/DC adapter.
4. A Dterm can equip only one out of following three adapters at the same time:
(Bundle type Dterm IP (16D/32D) can not equip any of the following adapters.)
- Analog Port Adapter (APR)
- CTI Adapter (CTA)
- IP Adapter (IPW)
5. A Wall Mount Unit is required when the Dterm set with an optional adapter is wall-mounted.
The Dterm set without an optional adapter can be wall-mounted without the Wall Mount Unit.
6. Cable length is based on the cable with 0.5mm diameter and without lightning arresters.
7. LCD beside Line/Feature keys displays only English.
8. 16LD ADM is available with 3500 series R10 or later software.
16LD ADM is not available for China.
9. Dterm 2DT and Dterm 4D are available with 3200 series R6.1 or later software.
Page 24
PI-286
ISSUE 8
18. Dterm Series i (Russian-Display Model; 3600 series R11 or later)
DESCRIPTION SPECIFICATIONS
term term term
D 8D-R D 16D-R D 32D-R
Max. Number of Line 8 16 16
/Programmable Feature Keys (with LED) (with LED) (with LED)
Number of One-Touch Dial Keys NO NO 16
Number of Dedicated Feature Keys 10 10 10
Speaker YES YES YES
Answer YES YES YES
Hold YES YES YES
Transfer YES YES YES
Recall YES YES YES
Conference YES YES YES
Redial YES YES YES
Feature YES YES YES
MIC NO NO NO
Call YES YES YES
Volume Control keys YES YES YES
Number of Soft Keys 4 4 4
Indicator on Line/Feature Keys LED LED LED
Green/Red Green/Red Green/Red
LCD Display 24 x 3 24 x 3 24 x 3
(Number of Characters x Lines)
Note 1
Multilanguage display on 24 x 3 LCD 13 language 13 language 13 language
Call Indicator LED YES YES YES
/Message Waiting LED
Accessories
Note 2
Headset Jack Connecter Built-in Built-in Built-in
Hands-Free Unit Built-in Built-in Built-in
DSS/BLF Console Note 3, 7 Option Option Option
Note8
16LD ADM NO NO NO
Ancillary Device Adapter (ADA) Option Option Option
Note 3,4
Analog Port Adapter (APR) Option Option Option
CT Adapter (CTA) Note 3,4 Option Option Option
Note 3,4
IP Adapter (IPW) NO NO NO
Wall Mount Unit Note 5 Option Option Option
AC Adapter Option Option Option
Cabling 1-Pair 1-Pair 1-Pair
Max. Cable Length Note 6
8DLC/4DLC Card 300m 300m 300m
2DLC Card 850m 850m 850m
4DLC/2DLC Card with AC Adapter 1200m 1200m 1200m
Color White White White
Page 25
PI-286
ISSUE 8
Notes:
1. One of below language can be assigned per terminal basis (R11 or later software).
- Danish
- Dutch
- English
- French (Canadian)
- French (European)
- German
- Italian
- Portuguese (Brazilian)
- Portuguese (European)
- Spanish (Latin)
- Spanish (European)
- Swedish
- Russian
2. Plantronics Supra-NC Polaris (Product Code: P51N-U 10P) is recommended.
3. It requires an AC/DC adapter.
4. A Dterm can equip only one out of following two adapters at the same time:
- Analog Port Adapter (APR)
- CTI Adapter (CTA)
5. A Wall Mount Unit is required when the Dterm set with an optional adapter is wall-mounted.
The Dterm set without an optional adapter can be wall-mounted without the Wall Mount Unit.
6. Cable length is based on the cable with 0.5mm diameter and without lightning arresters.
7. DSS/BLF Console is one for Dterm series I (Standard Model).
Page 26
PI-286
ISSUE 8
19. ATTENDATNT CONSOLE
DESCRIPTION SPECIFICATIONS
Smart Console (SN709/712/741) Desk Console (SN716)
(Production discontinued)
Number of Loop Keys Note 1 6
Number of Multi-Function Keys 6 4
Incoming Call Identification keys 6 6
Function Keys 8 18
PAGE Key Yes Note 2 Yes
REC Key No Yes
Mute Key No Yes
Night Key Yes Note 3 Yes
Position Busy Key Yes Note 3 Yes
Volume Control Key Yes Note 4 Yes
(Receiver volume, Ringer
volume, LCD contrast)
LED indicator on Loop Keys / 2-Color
Function Keys (Green, Red)
LCD Display Yes
(Number of Characters x Lines) (40 x 4)
Handset/Headset Jack Connector Yes
Note 5
Page 27
PI-286
ISSUE 8
20. MAINTENANCE ADMINISTRATION TERMINAL (MAT)
(1) PC Requirements for MAT
For Windows 2000/ Me / XP / 2003 (Windows 2003 is available from MATWorX Ver.11)
DESCRIPTION SPECIFICATIONS
Minimum Recommended
CPU PentiumⅡ 350 MHz PentiumIV 1GHz
RAM 128MB 256MB
Hard Disk Drive (HDD) 230MB or more
Monitor SVGA (800 x 600) SVGA (1,024 x 768)
High color (16-bit) True Color (32-bit)
15-inch or larger monitor
Peripherals LAN Interface Card, CD-ROM Drive,
Floppy Disk Drive, Keyboard, Mouse
Note: Key FD (name with –B1) with Software License Authentication can be loaded from a PC with Microsoft
Windows XP, 2000 and NT4.0 (SP5 or later version), in addition to Windows 95 (OSR2 or later version),
98, Me. Key FD (name with –A1) with non-Software License Authentication must be loaded from a PC
with Windows 95 (OSR2 or later version), 98, Me.
OS Compatibility of MATWorX
DESCRIPTION SPECIFICATIONS
Page 29
PI-286
ISSUE 8
21. ANNOUNCEMENT SERVICE
(1) Digital Announcement Trunk (DAT)
Page 30
PI-286
ISSUE 8
22. DATA COMMUNICATIONS
Analog Port Adapter (APR)
DESCRIPTION SPECIFICATIONS
Page 31
PI-286
ISSUE 8
23. STATION MESSAGE DETAIL RECORDING (SMDR)
(1) SMDR TERMINAL INTERFACE
Note 5
I/O Port RS port of MP card No. 0-3 port of AP00- card
Number of Stations Registered Max. 1,020 stations Max. 504 stations Max. 1,020 stations
Pseudo-Answer Timing for Charging 8 to 40 sec. (programmable in 4-sec. increment)
Start
Charging to a Transferred Call Note 6 The Following options are available by data programming:
(1) Split charging to both transfer destination station and the
transferring station.
(2) Charging to the final transfer destination.
(3) Charging to the first transfer destination station.
Notes:
1. Built-in SMDR on RS-232C cannot be provided when SPN-AP00B MRC-C(AP) or earlier is used.
2. In Built-in SMDR on RS-232C, MP reset clears the call records stored in buffer memory.
3. Built-in SMDR on RS-232C can be used for remote office in Centralized Billing of CCIS network.
4. 5-digit station number is available when the leading digit is fixed number.
5. RS-232C Interface port is max. 2 ports per system.
6. In case of call transfer between an Attendant Console and a station, the charging is made to the station,
in any data programming.
7. SMDR for internal calls is available from 3600 series R11 or later software.
AP00 must be SPN-AP00B MRC-F (AP) or later (PN-AP00-B with SC-3480 PROG-B1) or later / SPN-AP00D
MRC-B(AP) (PN-AP00-D with SC-3682 IPS MRCA PROG-D1).
Page 32
PI-286
ISSUE 8
Notes:
1. Built-in SMDR on IP is available from 3400 series R9 software.
2. Built-in SMDR on IP cannot be provided when SPN-AP00B MRC-C(AP) or earlier is used.
3. In Built-in SMDR on IP, MP reset clears the call records stored in buffer memory
4. In case of call transfer between an Attendant Console and a station, the charging is made to the station,
in any data programming.
5. SMDR for internal calls is available from 3600 series R11 or later software.
Page 33
PI-286
ISSUE 8
Notes:
1. When the number of call records stored reaches the buffer capacity, new call records will be lost.
2. When the number of call records stored reached the buffer capacity, the system operates in one of the
following methods, by data programming.
(1) No new call record is stored.
(2) New call record is stored by deleting the oldest call record.
3. Figure in parenthesis is buffer memory capacity when Expansion Memory (PZ-M537) is equipped on
AP00B card.
4. When both SMDR and CIS are used in the system, the buffer memory capacity is Max. 26,000 calls
including CIS buffer memory.
Page 34
PI-286
ISSUE 8
(2) SMDR OUTPUT FORMAT
Notes:
1. This feature is available from 3400 series R9 software.
2. This feature is available from 3300 series R8 software.
3. When a communication is disconnected, the billing information is stored at local office.
4. Firmware program (SC-3168 IXS AP PROG-A1) issue 2 or later is required.
5. The billing information cannot be output at local office.
When a failure of center office occurs or the CCIS link is disconnected, the billing information is stored at
local office.
6. SPN-AP00B MRC-E(AP) or later / SPN-AP00D MRC-B(AP) do not support the following features
- SMDR 1400IMS format - Hotel Printer - CIS
Page 35
PI-286
ISSUE 8
Notes:
1. For output to built-in SMDR on RS-232C, one message is sent at intervals of one second unidirectionally.
For output to built-in SMDR on IP, one message is sent each time a request is received from SMDR terminal.
2. Output to built-in SMDR on RS-232C and output to built-in SMDR on IP cannot be performed at the same
time.
3. Built-in SMDR cannot be provided when SPN-AP00B MRC-C(AP) or earlier is used.
Page 36
PI-286
ISSUE 8
Type of Calls Applicable to SMDR Outgoing Call / Incoming Call / Tandem Call
Service
Number of CIS Printer Max. 2 printers per system
Number of CIS Control Terminals Max. 8 Dterm sets with LCD per system
(Dterm)
Max. Rate of Call Charge $0.00 to $999.99
per Station
Terminal Interface
Physical Interface RS-232C
Synchronization Asynchronous
Transmission Speed 300 / 1,200 / 2,400 / 4,800 bps
Type of Reports
Call Record This report provides detailed call information on a station or a station
group basis. Information included are;
• Calling Station Number
• Dialed Number
• Call Start Time
• Call Duration
• Call Charge
• Account Code
• Authorization Code
Totaled Call Charge This report provides a total amount of call charge on a station or a
station group basis.
Type of Output
Immediate Printout This allows an immediate printout of Call Record after completion of
each call.
Interim Report This report allows a display or a printout of Call Record or Totaled
Call Charge by the key operation from the CIS Control Terminal
(Dterm).
After display or printout, the information is still remained in the system.
Audit Report This report allows a display or a printout of Call Record or Totaled
Call Charge by the key operation from the CIS Control Terminal
(Dterm).
After display or printout, the information is deleted from the system.
Charging Method
H-Method Unit Time (call duration) is fixed, and Charging Rate per Unit Time
varies depending on the destination (area).
K-Method Charging Rate per Unit Time is fixed, and Unit Time varies depending
on the destination (area).
Flat Rate Fixed charge per call, regardless of call duration and destination.
Metering Pulse The system counts up the number of Metering Pulse from Central
Office, and calculates call charge on each call with the preprogrammed
charging rate per pulse.
Page 37
PI-286
ISSUE 8
DESCRIPTION SPECIFICATIONS
Notes:
1. The buffer memory capacity includes that for SMDR.
2. When the system is a center office of Centralized Billing in CCIS network, the buffer memory capacity is max.
800 calls.
3. In case of call transfer between an Attendant Console and a station, the charging is made to the station,
in any data programming.
4. SPN-AP00B MRC-E(AP) or later / SPN-AP00D MRC-B(AP) do not support the following features.
- PMS
- SMDR 1400IMS format
- Hotel Printer, CIS
Page 38
PI-286
ISSUE 8
25. PROPERTY MANAGEMENT SYSTEM (PMS) INTERFACE
Page 39
PI-286
ISSUE 8
26. MESSAGE CENTER INTERFACE (MCI)
Page 40
PI-286
ISSUE 8
Note:
Tie line connections via optical modem are available between 2000 IPS systems.
Page 41
PI-286
ISSUE 8
29. IP TRUNK INTERFACE
FUNCTION SPECIFICATIONS NOTES
CODEC
G.729a Yes Reduce complexity of 8K CS-ACELP
G.723.1 Yes 5.3/6.3K MP-MLQ/ACELP
G.711 Yes 64K PCM
FAX FAX Relay based on T.30 G3 FAX
for CCIS Support V.17, V.29 and V.27ter
PBX Signaling
CCIS Note1 Yes (P-MP)
CCIS connected to Yes (P-MP)
FCCS Note 1
QSIG No
H.323 Client Note 2 Yes
Connection to H.323 Yes
Gatekeeper Note2
Dynamic Jitter Buffer Max. 300msec.
Ethernet Interface 10M/100M Ethernet
with RJ-45 connector
Number of IP Trunks Max. 8 Max. 1 IPT per Physical PIM
(Card-type IPT)
Number of Voice Channels Max. 127ch The number of IPT voice channels is
per System included in the condition of max. 256
trunks per system.
Number of Voice Channels Max. 16ch per IPT.
per IP Trunk Note3
QoS
TOS, IP Precedence Yes
Diffserv Yes (H.323 only)
Echo Canceller G.168 Roundtrip time: up to 32msec.
Modem Connection No
Tandem Connection
64K TDM Yes
TDM with Compression No
Notes:
1. CCIS signaling over IP are provided by either Virtual IP trunks (no hardware required) or IP trunk cards.
The Virtual IP trunks can be used when the distant office is 2000 IPS or 2400 IPX only.
(When the distant system is M100MX/2000IVS or 7400 ICS (IMX), the IP trunk cards are required.)
2. H.323 signaling requires IPT cards.
3. The number of Voice Channels per IP Trunk depends on the payload size as follows (payload size can be
assigned in system programming.):
Page 42
PI-286
ISSUE 8
30. IP STATION INTERFACE
FUNCTION SPECIFICATIONS NOTES
PN-32IPLA-A(32ch) PN-8IPLA(8ch)
CODEC G.711/G.729a/G.723.1 G.711 (64Kbps)
G.7291 (8Kbps)
G.723.1 (5.3Kbps/6.3Kbps)
Dterm IP Signaling
PROTIMS Over IP Yes
H.323 with Gatekeeper No
Dynamic Jitter Buffer Max. 300msec.
Ethernet Interface 10M/100M Ethernet 100Mbps is recommended.
with RJ-45 connector
Number of IP Stations per Max. 956 The number depends on the
System system configuration.
Number of IP PADs Max. 8 Max. 2 IP PADs per FP Note 1.
per system
Number of Voice Channels 32ch. 8ch. Max.16ch. when using
per IP PAD (Max. 32ch G.723.1.
w/PZ-24IPLA)
Payload Size G.711: 10ms to 40ms (Default: 40ms) Can be assigned in system
G.729a: 10ms to 40ms (Default: 40ms) programming (10ms
G.723.1: 30ms (fixed) increment).
FAX T.30 G.711/G.726 Refer to APPENDIX D for
G.711/G.726 pass-through detailed conditions.
pass-through
Modem No G.711/G.726 G.711 pass through: 14.4k-24Kbps
pass-through G.726 pass through: 9.6k-14.4kbps
QoS
TOS, IP Precedence Yes
Diffserv Yes
Echo Canceller G.168 Roundtrip time: up to
64msec.
Modem Connection No
VLAN Note 2 Yes Yes
(IEEE 802.1Q (IEEE 802.1P
compliant) compliant)
System Registration Login/Logout with password, Login ID and password can
MAC address authentication be
encrypted.
Bandwidth Control Note 3 Yes
Notes:
1. The IP PADs are required for the following connections/statuses:
z Connections between Dterm IP stations and legacy stations/trunks
z Connections between Dterm IP stations and IP trunk cards (CCIS/H.323)
z CCIS connections via IP from/to legacy stations/trunks
z CCIS connections via IP with M100MX/2000IVS or 7400 ICS (IMX)
z While Dterm IP stations are on hold (Consultation Hold, Call Transfer, etc.)
z When any override service is activated (Executive Right of Way, etc.)
z Conference features (three/four-party, 6/10-party, 32-party) including Dterm IP stations
Page 43
PI-286
ISSUE 8
The IP PADs are not required for the following connections/statuses:
z Connections between Dterm IP stations
z Connections for CCIS networking via IP from/to Dterm IP stations
(Distant systems must be 2000 IPS or 2400 IPX)
2. VLAN feature is available from 3100 series software.
The VLAN ID can be assigned to MP, IP PAD, and Dterm IP telephones respectively.
Note that the multiple VLAN IDs cannot be assigned to each device.
3. Bandwidth Control feature is available from 3100 series software.
Page 44
PI-286
ISSUE 8
31. CENTRALIZED MAT
(1) PC Requirements
MATWorX version
Version 10 or earlier OK NG
Version 11 or later NG OK
Page 45
PI-286
ISSUE 8
DESCRIPTION SPECIFICATIONS
PBX requirements NEAX 2000 IPS, NEAX7400ICS M100MX/NEAX2000 IVS,
or M100MX Retrofit system Note1
(M100MX/2000IVS: Release 3.2 or later software version Note2)
Network Configuration CCIS network (including CCIS network via IP) Note3
Connection Note4 RS232C Interface or LAN connection
Number of offices Up to 255 offices per CCIS/IP network
Number of networks Up to 5 networks
Number of networks 5 networks Note5
for Fault Alarm Detection
Notes:
1. M100MX Retrofit system must be a local office.
2. This software version is required in each center and local office for M100MX/2000IVS systems..
The center office must have an Expansion Memory Card (PZ-M537) on a MP card.
3. Centralized MAT cannot supervise the network connected by Event based CCIS and IP with H.323
protocol.
4. Modem connection is not available.
5. The number of networks depends on the period as follows (period can be assigned in Centralized
MAT.):
Page 46
PI-286
ISSUE 8
32. REMOTE MAT (Production discontinued)
(1) PC Requirements
DESCRIPTION SPECIFICATIONS
NEAX 2000 IPS / M80VS / M100
M100MX / 2000IVS
(incl. M100MX Retrofit system)
Required Software 2000IPS GD version or later
: All version
M100MX/2000IVS
: Release 2.1 or later
Number of remote offices Up to 1,000 offices GD version or earlier : Max.60 offices
J version or later : Max.540 offices
Interface condition RS232C (Serial port)
Connection Modem connection
Page 47
PI-286
ISSUE 8
33. Dterm ASSISTANT
(1) PC Requirements
Page 48
PI-286
ISSUE 8
(2) System Capacity
DESCRIPTION SPECIFICATIONS
Page 49
PI-286
ISSUE 8
34. IN-SKIN ROUTER (Production discontinued)
DESCRIPTION SPECIFICATIONS
Page 50
PI-286
ISSUE 8
APPENDIX A: MTBF OF EACH CARD
CARD NAME FIT MTBF (YEARS)
LT CARDS (Continued)
PN-8DLCP 1,848 61.8
PN-2DPCB 11,415 10.0
PN-2ILCA 5,849 19.5
PN-32IPLA 11,216 10.2
PN-32IPLA-A 11,112 10.3
PN-4LCC 1,367 83.5
PN-4LCD-A 1,961 58.2
PN-4LCK (for China) 1,375 83.0
PN-4LCL (for China) 1,752 65.2
PN-8LCAA 1,934 59.0
PN-8LCAK 1,226 93.1
PN-8LCAB (for China) 1,934 59.0
PN-8LCAD (for Caller ID) 2,174 52.5
PN-8LCAE (for Caller ID, China) 2,374 48.1
PN-2LDTA 1,546 73.8
PN-4LDTA 5,625 20.3
PN-4LLCB 1,792 63.7
PN-M03 (DPC V.35) 7,815 14.6
PN-M10 (Optical Modem) 1,750 65.2
PN-2ODTA 2,965 38.5
PN-4RSTF (Caller ID Sender) 699 163.3
PN-4RSTF-A 2,763 41.3
PN-8RSTG 133 858.3
PN-4VCTI (VoIP) 1,435 79.5
PN-16VCTA 2,674 42.7
PN-16VCTA-A 2,675 42.7
PZ-VM00-M (NEAXMail AD-8) 8,589 13.3
PZ-VM10-M (NEAXMail AD-8) 7,582 15.1
PZ-VM01/R (NEAXMail AD-8) 582 196.1
PN-4ODTA 5,625 20.3
PN-8IPLA 5,997 19.0
PZ-24IPLA 1,177 96.9
PN-8IPLA + PZ-24IPLA 7,174 15.9
PN-8IPTA (SIP Trunk) 5,997 19.0
PN-RTA + PZ-M650 5,492 20.9
PN-RTA + PZ-M623 3,470 32.9
PN-RTA + PZ-M649 5,792 19.7
PZ-VM02 19,103 6.0
AP CARDS
PN-AP00-B 5,196 22.0
PN-AP00-D 12,761 9.0
PN-BRTA 8,207 13.9
PN-2BRTC 4,124 27.7
PN-4BRTA-A 6,566 17.4
PN-24CCTA 4,625 24.7
PN-30CCTA 4,082 28.0
PN-CFTC (32-Party Conference) 6,000 19.0
PN-CFTC-A (32-Party Conference) 6,312 18.1
Page 52
PI-286
ISSUE 8
CARD NAME FIT MTBF (YEARS)
AP CARDS (Continued)
PN-DAIA (T1 Remote PIM; Main) 13,414 8.5
PN-DAIA-A (T1 Remote PIM; Main) 13,414 8.6
PN-DAIB (T1 Remote PIM; Remote) 13,356 8.5
PN-DAIC (T1 Remote PIM; Exp.) 8,941 12.8
PN-DAID (E1 Remote PIM; Main) 17,199 6.6
PN-DAID-A (E1 Remote PIM; Main) 17,199 6.6
PN-DAIE (E1 Remote PIM; Remote) 18,122 6.3
PN-DAIF (E1 Remote PIM; Exp.) 7,840 14.6
PN-24DTA-C 4,625 24.7
PN-30DTC-C 3,504 32.6
PN-DTA 4,213 27.1
PN-IPTB (VoIP) 5,757 19.8
PN-24PRTA 4,625 24.7
PN-30PRTA 4,082 28.0
PN-4RSTB (MFC) 5,607 20.4
PN-4RSTB-A (MFC) 5,733 19.9
PN-4RSTC (Caller ID Receiver) 12,349 9.2
PN-4RSTC-A (Caller ID Receiver) 16,301 7.0
PN-SC00 (CCH) 8,816 12.9
PN-SC01 (DCH) 8,188 13.9
PN-SC03-B (ICH/CSH) 6,816 16.8
PN-SC03-C (CSH) 8,224 13.9
PN-2ILCC 13,754 8.3
Page 53
PI-286
ISSUE 8
APPENDIX B: CURRENT CONSUMPTION OF EACH CARD
CARD NAME DC Current Consumption (mA)
(at –27V)
MP / FP / POWER / PFT
PN-CP24-A (MP) 430
PZ-M606-A (Ethernet Interface)
PN-CP26-A (Retrofit MP) 321
PZ-M606-A (Ethernet Interface)
PN-CP26-B (Retrofit MP) 252
PN-CP26-B (with PZ-M606-A) 311
PN-CP24-B 316
PN-CP24-B (with PZ-M606-A) 365
PN-CP24-C 249
PN-CP24-C (with PZ-M606-A) 316
PN-CP24-D 264
PN-CP24-D (with PZ-M606-A) 321
PN-CP27-A 430
PN-CP27-B 264
PN-CP27-B (with PZ-M606-A) 321
PN-CP28-A 333
PN-CP28-B 267
PN-CP28-B (with PZ-M606-A) 328
PN-CP31-A (with PZ-M606-A) 314
PN-CP31-B 304
PN-CP31B (with PZ-M606-A) 368
PN-CP31-C 257
PN-CP31-C (with PZ-M606-A) 291
PN-CP31-D 264
PN-CP31-D (with PZ-M606-A) 321
PN-CP15 (FP) 133
PN-CP17 (Retrofit FP) 73
PN-PW00 (DC-DC; -48V) 800
PZ-PW122 (DC-DC: -48V) 3,600
PZ-8PFTB 140
LT CARDS
PN-2AMPA 43
PN-CFTA (6-Party Conference) 31
PN-CFTB (6-Party Conf. with Amp.) 60
PN-2COTD (Metering Pulse) 122
PN-2COTE 168
PN-4COTA-A (Loop Start) 144
PN-8COTQ (Caller ID) 161
PN-8COTR (Loop Start) 146
PN-2CSIA-A 23
PN-2CSIH 76
PN-4DATC 19
PN-2DITA (for Hong Kong) 261
PN-4DIDA 433
PN-4DITB 347
PN-DK00 81
Page 54
PI-286
ISSUE 8
CARD NAME DC Current Consumption (mA)
(at –27V)
LT CARDS (Continued)
PN-2DLCB (-48V) 230
PN-4DLCM 250
PN-4DLCQ 250
PN-4DLCT 488
PN-8DLCL 515
PN-8DLCP 515
PN-2DPCB 94
PN-2ILCA 55
PN-32IPLA 455
PN-32IPLA-A 388
PN-4LCC 181
PN-4LCD-A 269
PN-4LCK (for China) 223
PN-4LCL (for China) 439
PN-8LCAA 453
PN-8LCAK 324
PN-8LCAB (for China) 451
PN-8LCAD (for caller ID) 249
PN-8LCAE (for caller ID, China) 294
PN-2LDTA 256
PN-4LDTA 442
PN-4LLCB 329
PN-M03 (DPC V.35) 107
PN-M10 (Optical Modem) 85
PN-2ODTA 121
PN-4RSTF (Caller ID Sender) 77
PN-4RSTF-A 10
PN-8RSTG 50
PN-4VCTI (VoIP) 138
PN-16VCTA 163
PN-16VCTA-A 151
NEAXMail AD-8(PZ-VM00-M + VM01/R) 507
NEAXMail AD-8(PZ-VM10-M + VM01/R) 507
PN-4ODTA (E&M Type-I) 1,314
PN-4ODTA 85
PN-8IPLA 167
PN-8IPLA + PZ-24IPLA 212
PN-RTA + PZ-M650 178
PN-RTA + PZ-M623 176
PN-RTA + PZ-M649 210
PZ-VM02 (including HD) 1,240
AP CARDS
PN-AP00-B 96
PN-AP00-D 128
PN-BRTA 51
PN-2BRTC 79
PN-4BRTA-A 160
PN-24CCTA 132
Page 55
PI-286
ISSUE 8
CARD NAME DC Current Consumption (mA)
(at –27V)
AP CARDS (Continued)
PN-30CCTA 96
PN-CFTC (32-Party Conference) 70
PN-CFTC-A (32-Party Conference) 146
PN-DAIA (T1 Remote PIM; Main) 132
PN-DAIA-A (T1 Remote PIM; Main) 132
PN-DAIB (T1 Remote PIM; Remote) 122
PN-DAIC (T1 Remote PIM; Exp.) 59
PN-DAID (E1 Remote PIM; Main) 116
PN-DAID-A (E1 Remote PIM; Main) 116
PN-DAIE (E1 Remote PIM; Remote) 111
PN-DAIF (E1 Remote PIM; Exp.) 57
PN-24DTA-C 123
PN-30DTC-C 81
PN-DTA 128
PN-IPTB (VoIP) 442
PN-24PRTA 132
PN-30PRTA 96
PN-4RSTB (MFC) 27
PN-4RSTB-A (MFC) 102
PN-4RSTC (Caller ID Receiver) 57
PN-4RSTC-A (Caller ID Receiver) 112
PN-SC00 (CCH) 49
PN-SC01 (DCH) 44
PN-SC03-B (CSH) 73
PN-SC03-C (CSH) 170
PN-2ILCC 163
Page 56
PI-286
ISSUE 8
APPENDIX C: PORT ALLOCATION
(1) General
Page 57
PI-286
ISSUE 8
(2) LT Cards
Page 58
PI-286
ISSUE 8
CARD NAME NUMBER OF PORTS
PER CARD
PN-VM01/R (NEAXMail AD-8) 0
PN-4ODTA 4
PN-8IPLA 8
PZ-24IPLA 24
PN-8IPTA (SIP Trunk) 8
PZ-VM02 0
Page 59
PI-286
ISSUE 8
(3) AP Cards
Page 60
PI-286
ISSUE 8
Page 61
PI-286
ISSUE 8
Page 62