nvlad CALIBRATION NVLAE CAB CODE wosEvE-0 Certificate of Calibration Fluke Park Laboratory Description: Field Metrology Well with Process Readout Certificate Number: 86407046 Manufacturer: Fluke Date of Calibration: 07 oct 2016 Model: 9242 Date Due: Serial Number: a6A868 ‘Temperature: 20.010 26.0°C Status: As-Found: New Relative Humidity: 20 1070 %RH As-Left: In Tolerance Pressure: 95 to 103 kPa Calibration: = Full Issue Date: 07 Oct 2016 Procedure: HCT301-1 Customer: INTERWORLD HIGHWAY LLC JONESTOWN PA, PONumber: 9126031 ‘This calibration is traceable to the Si through recognized national measurement institutes (NIST, PTB, NPL. NIM, NRC, etc.) ratiometric techniques, or natural physical constants and is in compliance with ISQAEC?7026-2008 and ANSUNCSL 2540,1. The calibration nas been completed in accordance with the Fluke Corporate Quality System document OSD 111.0. Calibration certificates without identification of the authorzing person are not cate This certificate apples to only the item identified and shall not be reproduced other than in full without the specific wnitten approval by Fluke Corporation This calibration certificate may contain data that is not covered by the Scope of Accreditation The unaccredited {est points, where appiicable, are indicated by an asterisk (*). or confined to clearly marked sections The cortficate shall not be used to claim product certification, approval, or endorsement by NVLAP. NIST. or any agency of the U.S. Government. Measurement uncertainties at the time of test are given where applicable. They are calculates in accordance with the method described in the ISO Guide to the Expression of Uncertainty in Measurement. The reported expanded {inceriainty of measurement is stated as the standard uncertainty of measurement multiplied by the coverage factor k such that the coverage probability corresponds to approximately 86 % ‘Comments: es SEY cere +. seag70es Be Electronically signed by meer ee oere Rg Approved Signatory Sr aes0s8 i Ivars tkstrums 7H satan Metrologist Fluke Corporation Telephone internet ___ Page 1 of 4 6920 Seaway Blvd 877.385.3225, www flukecal.com Rev 20160922" Everett, WA 98203 USA Certificate Number: 86407046 Date of Calibratio: Standards Used Description Serial Number Due-pate 35866 Digital therroreter 26032 R 1560 Therroneter, “Black Stack” Base Unit 808223 2562-H Precision Digite] Thennoneten Boso7e ov-2016 2562-H Precision Digital Thermonete> Bian? tow-2036 5628 Plotinu Resistance Tnernonete~ 178e 5628 Platinun Resistance Thermometer 2247 V7 emar-2027 1529-8 Thermoneter, Chud-E4, 4-PRT/Thenaistor 54889 “way-2027 5616 Therristor Prove 890201 26-Nov-2626 5610 Thermistor Probe 8222908 26-Nov-2016 5780A OC Reference Stancare 9595607 23-wov-2016 7498 Stendarc Resistor Set 80002 25-Nov-2676 Field Metrology well Test station 5 nck Quality Manuals This calibration has been completed in accordance with’ + The Fluke Corporate Quality Manual, QSD 111.0, Revision 118, Dated August, 2014 and/or + The Fluke 17025 Quality Manual, QSD 111.41, Revision 005, Dated Sept. 2014 The instrument described herein consists of a heat source component and a built-in process readout component This calibration pertains to both components. The heat source component was calibrated by direct measurement of generated temperatures using the pertinent reference standards listed in the "Test Equipment” section of this report. The calioration was performed using test insert Model 914x-INST a5 described in the user manual. This insert is similar to insert “C° but is designed to accommodate the test PRTS and aid in the performance of the axial gradient calibration. The calibration data, internal calibration constants, and uncertainties are shown on the following page(s) of this report. The temperature ‘accuracy testis self-explanatory. The axial differential temperature test is more complex. Due to the nature of the axial differential temperature characteristic and the influence of the test equipment on the test result, this test utilizes tolerances which do not precisely match the instrument specification. However, the unique tolerances used are intended to determine the axial differential temperature tolerance status based on the published specifications, ‘The temperature observations were performed in both increasing and decreasing directions. The process readout component was calibrated directly using laboratory transfer standards as listed in the "Test Equipment” section of this report. The calibration data, internal calibration constants, and uncertainties are shown con the following page(s) of this report. The calibration uncertainties are shown at a coverage factor of 2 (k=2). All known significant sources of uncertainty have been considered. Any limitations or remarks pertaining to this instrument and/or calibration are shown below, Additionally, out of tolerance indications, if any, are identified along with the corresponding data on the data pages of this report, Calibration uncertainties have been taken into account in the determination of tolerance status using risk analysis algorithms. When using the instrument in a catibration process, tis recommended that the instrument specifications be used as the contribution of the instrument rather than the calibration uncertainties, The instrument tolerances are shown on the report at a confidence interval of 95% The sections labeled Temperature Stability, Axial Differential Temperature and/or Maximum Hysteresis contain data that are not covered by the NVLAP Scope of Accreditation Page 2 of 4 Model 9142 Serial No., SBA868 Certificate No 88407046 ‘6 Found Data No As Found Data Reauired Certificate of Calibration [— As Left Data Data 1D: B6280115507327 Calioration Constants TEMP? 0.099 TEMP2 0.194 TEMP3 0.342 GRADi -0.014 GRAD2 0.016 GRAD3 0.000 _ Control Constants TEMPPS 2.0 TEMPINT 300 TEMPOER 4.0 Temperature Accuracy Set-point °C Actual ~~ -25:000 24,984 0.000 0.007 50.000 49.995 100.000 100.013 160,000 149,995 ‘Temperature Stability Observed *C Setpoint "S| (2 Sigma) “25.000 0.001 160.000 0.002 Axial Differential Temperature Sor-point"C _Target°C Actual °C. ‘0.000 0.000 0.000 0.003 0.010 0.004 0.010 0.015 Etror°C 0.016 0.007 0.008 0.013 0.008 Tolerance °C 20.010 30.010 Error °C. 0.000 0.003 0.006 0.005: 0.200 $0,200 20.200 Uncenamty +£0.0040 20.0055 PassiFai) e Pp Tolerance *C_Uncertainty £0,040 40.040 40.040 20.040 20.020 +0020 40.025 20.030 PassiFail veveD Passail_ > Pe Pp P This report shall not be reproduced except i fll without writen approval of Flake Calibration Page 3 ot 4

Вам также может понравиться