Вы находитесь на странице: 1из 2

Design hydrostatics report

Design hydrostatics report


Pescador
Designer ERA
Created by M. van Engeland
Comment
Filename FINALERA.fbm
Design length 31.882 (m) Midship location 15.941 (m)
Length over all 36.399 (m) Relative water density 1.0250
Design beam 9.436 (m) Mean shell thickness 0.0000 (m)
Maximum beam 9.507 (m) Appendage coefficient 1.0000
Design draft 4.500 (m)

Volume properties Waterplane properties


Moulded volume 919.54 (m3) Length on waterline 35.076 (m)
Total displaced volume 919.54 (m3) Beam on waterline 9.507 (m)
Displacement 942.53 (tonnes) Entrance angle 78.232 (Degr.)
Block coefficient 0.6096 Waterplane area 289.21 (m2)
Prismatic coefficient 0.7005 Waterplane coefficient 0.8627
Vert. prismatic coefficient 0.7065 Waterplane center of floatation 13.746 (m)
Wetted surface area 487.77 (m2) Transverse moment of inertia 1907.2 (m4)
Longitudinal center of buoyancy 14.829 (m) Longitudinal moment of inertia 23987 (m4)
Longitudinal center of buoyancy -3.169 %
Vertical center of buoyancy 2.647 (m)
Total length of submerged body 35.261 (m)
Total beam of submerged body 9.507 (m)

Midship properties Initial stability


Midship section area 37.23 (m2) Transverse metacentric height 4.721 (m)
Midship coefficient 0.8701 Longitudinal metacentric height 28.732 (m)

Lateral plane
Lateral area 148.03 (m2)
Longitudinal center of effort 15.919 (m)
Vertical center of effort 2.303 (m)

The following layer properties are calculated for both sides of the ship
Location Area Thickness Weight LCG TCG VCG
(m2) (m) (tonnes) (m) (m) (m)
Layer 0 613.32 0.000 0.00 15.834 0.000 (CL) 2.589

Sectional areas
Location Area Location Area Location Area Location Area Location Area
(m) (m2) (m) (m2) (m) (m2) (m) (m2) (m) (m2)
-1.506 9.57 6.023 29.47 13.551 37.29 21.079 37.17 28.607 13.42
0.000 11.35 7.528 34.22 15.056 37.29 22.585 34.76 30.113 8.69
1.506 14.53 9.034 36.73 16.562 37.22 24.090 29.28 31.619 4.27
3.011 19.58 10.540 37.30 18.068 37.29 25.596 23.95 33.124 0.00
4.517 24.62 12.045 37.27 19.573 37.37 27.102 18.58

4/4/2019 1
Design hydrostatics report

Sectional areas
37.5

35.0

32.5

30.0

27.5

25.0

22.5
Area (m2)

20.0

17.5

15.0

12.5

10.0

7.5

5.0

2.5

0.0

0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0 27.5 30.0 32.5

Location (m)

NOTE 1: Draft (and all other vertical heights) is measured from base Z=0.000
NOTE 2: All calculated coefficients based on actual dimensions of submerged body.

4/4/2019 2

Вам также может понравиться