All elements are optimised for low inrush current across the
VDE 40030313
permissible voltage range.
UL E319928
CSA pending
Variants
Type Blizzard Blizzard Blizzard Blizzard
50L 20W 200L 30W 50H 40W 200H 65 W
Nominal Power Output at 10ºC (50ºF) 20W 30W 40W 65W
Typical Peak Inrush Current (Arms) 230V/115V 0.6/0.8 1.8/2.2 1.6/2.0 5.5/5.5
Maximum Body Temperature (30ºC ambient) 74ºC (165ºF) 105ºC (221ºF)
Electrical Protection Class II
Ingress Protection (EN60529) IP20
•
•
Dual voltage 100-240V AC
•
UL94V-0 high temperature plastic housing
Touch safe heater; does not exceed 74ºC (165ºF) L version, 105ºC
•
(221ºF) H version
•
Optimised for low inrush current
•
Self-regulating, highest power at low ambient temperature
•
Easy connection, finger guard with integrated terminal block
•
Fixing - 35mm DIN-Rail mount (EN 50022)
Complies RoHS (EU Directive 2002/95/EC)
The information contained in this brochure is subject to change without notice. DBK Technitherm Ltd. Tel: ++44 (0)1443 237927 info-uk@dbk-group.com
Data is given for illustration purposes only and does not release the customer
Unit 11, Llantrisant Business Park Fax: ++ 44 (0)1443 237867 www.dbk-group.com
from independent application tests.
Llantrisant, Pontyclun
09/14