Вы находитесь на странице: 1из 16

Modern Jaya Sentausa CV

Jl. Raya Candi V/752, Malang, , Ph 0341-560 811, Fax 0341-556 256 Ver
TRUSS DETAIL SHEET Job Ref: GLB11
_______________________________________________________________________________
Customer: Pak Anton Site Addr: GreenLand Blok B 11

TRUSS DATA CHORDS WEBS


Truss Type : Std 1 4 75W80/55 u.o.n 75W80/55
TC pitch 1 : 35.00 4 6 75W80/55
Thickness : 33 1 6 75W80/55
Spacing : 1200
TC Battens : 350
TC Restraint: 350
BC Restraint: 1700
Timber Group: Steelumba
Building Importance : Residential
Roofing Material : Concrete tile-normal 510 Pa
Ceiling Material : 13mm P/Bd to battens 84 Pa
Overhang design assumes structural fascia.
Truss Mark <S1 > 1 Single Truss

< > = # screws @ joints, [ ] = # screws @ gussets


Steelfast Truss
All screws 10g 16x16 self drilling hex head

2930R 52R
52R 2930R

1464R 1465R 1465R 1464R

840V 1680V 840V


<3,3>
[4,4]
6(1772) o/all

<3> <3>

7 5

1 2 3 4

<5> <3,3> <3,3> <5>


(0) (2) camber (2) (0)
4.4 kN React (LSD) 4.4 kN React (LSD

1/Sldr 1/Sldr
1600R 1600R 1600R

Span 4800
Modern Jaya Sentausa CV
Jl. Raya Candi V/752, Malang, , Ph 0341-560 811, Fax 0341-556 256 Ver
TRUSS DETAIL SHEET Job Ref: GLB11
_______________________________________________________________________________
Joint 1 Joint 2 Joint 3 Joint 4

<5> <3,3> <3,3> <5>


Joint 5 Joint 6 Joint 7
[4,4]

<3> <3,3> <3>

Dimensional limitations(mm)
Edge End Spacing
Dist. Dist.
10g screw 7 14 14
12g screw 8 16 16
Modern Jaya Sentausa CV
Jl. Raya Candi V/752, Malang, , Ph 0341-560 811, Fax 0341-556 256 Ver
TRUSS DETAIL SHEET Job Ref: GLB11
_______________________________________________________________________________
Customer: Pak Anton Site Addr: GreenLand Blok B 11

TRUSS DATA CHORDS WEBS


Truss Type : Std 1 5 75W80/55 u.o.n 75W80/55
TC pitch 1 : 35.00 5 8 75W80/55
Thickness : 33 1 8 75W80/55
Spacing : 1200
TC Battens : 350
TC Restraint: 350
BC Restraint: 1700
Timber Group: Steelumba
Building Importance : Residential
Roofing Material : Concrete tile-normal 510 Pa
Ceiling Material : 13mm P/Bd to battens 84 Pa
Overhang design assumes structural fascia.
Truss Mark <S2 > 1 Single Truss

< > = # screws @ joints, [ ] = # screws @ gussets


Steelfast Truss
All screws 10g 16x16 self drilling hex head

458R 3906R 52R


52R 3907R 732R

1133R 1316R 1456R 1456R 1316R 1133R

650V 1405V 2240V 1405V 650V


<3>
[4,4]
8(2332) o/all

<3,3> <3,3>

9 7

<3> <3>

10 6

1 2 <4,3,3> 3 4 5

<6> <3,3> <3,3,3> <3,3> <6>


(0) (3) camber (3) (3) (0)
5.9 kN React (LSD) 6.3 kN React (L
1/Sldr 1/Sldr

1600R 1600R 1600R 1600R

375 Span 6400 600


Modern Jaya Sentausa CV
Jl. Raya Candi V/752, Malang, , Ph 0341-560 811, Fax 0341-556 256 Ver
TRUSS DETAIL SHEET Job Ref: GLB11
_______________________________________________________________________________
Joint 1 Joint 2 Joint 3 Joint 4

<6> <3,3> <3,3,3> <3,3>


Joint 5 Joint 6 Joint 7 Joint 8
[4,4]

<6> <3> <3,3> <3>


Joint 9 Joint 10 Joint 11

<3,3> <3> <4,3,3>

Dimensional limitations(mm)

Edge End Spacing


Dist. Dist.
10g screw 7 14 14
12g screw 8 16 16
Modern Jaya Sentausa CV
Jl. Raya Candi V/752, Malang, , Ph 0341-560 811, Fax 0341-556 256 Ver
TRUSS DETAIL SHEET Job Ref: GLB11
_______________________________________________________________________________
Customer: Pak Anton Site Addr: GreenLand Blok B 11

TRUSS DATA CHORDS WEBS


Truss Type : Std 1 5 75W80/55 u.o.n 75W80/55
TC pitch 1 : 35.00 5 8 75W80/55
Lh cut-off : 1250 10 8 75W80/55
Thickness : 33
Spacing : 1200
TC Battens : 350
TC Restraint: 350
BC Restraint: 1700
Timber Group: Steelumba
Building Importance : Residential
Roofing Material : Concrete tile-normal 510 Pa
Ceiling Material : 13mm P/Bd to battens 84 Pa
Overhang design assumes structural fascia.
Truss Mark <S3 > 3 Single Trusses

< > = # screws @ joints, [ ] = # screws @ gussets


Steelfast Truss
All screws 10g 16x16 self drilling hex head

2381R 52R
52R 3907R 732R

183R 740R 1456R 1456R 1316R 1133R

980V 1405V 2240V 1405V 650V


<3>
[3,3]
8(2332) o/all

<3,3> <3,3>

9 7

<3,3>
10 <3>

1 2 3 4 5

<4> <3,3> <3,3,3> <3,3> <5>


(0) (0) camber (1) (2) (0)
4.5 kN React (LSD) 5.3 kN React (LSD

1/Sldr 1/Sldr

200R 1599R 1600R 1599R

Span 5150 600


Modern Jaya Sentausa CV
Jl. Raya Candi V/752, Malang, , Ph 0341-560 811, Fax 0341-556 256 Ver
TRUSS DETAIL SHEET Job Ref: GLB11
_______________________________________________________________________________
Joint 1 Joint 2 Joint 3 Joint 4

<4> <3,3> <3,3,3> <3,3>


Joint 5 Joint 6 Joint 7 Joint 8
[3,3]

<5> <3> <3,3> <3>


Joint 9 Joint 10

<3,3> <3,3>
Modern Jaya Sentausa CV
Jl. Raya Candi V/752, Malang, , Ph 0341-560 811, Fax 0341-556 256 Ver
TRUSS DETAIL SHEET Job Ref: GLB11
_______________________________________________________________________________
Customer: Pak Anton Site Addr: GreenLand Blok B 11

TRUSS DATA CHORDS WEBS


Truss Type : Std 1 4 75W80/55 u.o.n 75W80/55
TC pitch 1 : 35.00 4 7 75W80/55
Lh cut-off : 2000 8 7 75W80/55
Thickness : 33
Spacing : 1200
TC Battens : 350
TC Restraint: 350
BC Restraint: 1700
Timber Group: Steelumba
Building Importance : Residential
Roofing Material : Concrete tile-normal 510 Pa
Ceiling Material : 13mm P/Bd to battens 84 Pa
Overhang design assumes structural fascia.
Truss Mark <S4 > 2 Single Trusses

< > = # screws @ joints, [ ] = # screws @ gussets


Steelfast Truss
All screws 10g 16x16 self drilling hex head

1465R 52R
52R 3907R 732R

183R 1282R 1456R 1316R 1133R

1505V 2240V 1405V 650V


<3>
[3,3]
7(2332) o/all

<3,3> <3,3>

8 6

<3>

1 2 3 4
<3> <3,3,3> <3,3> <4>
(0) (1) camber (1) (0)
4.1 kN React (LSD) 4.9 kN React (LSD)

1/Sldr 1/Sldr

1050R 1600R 1599R


Modern Jaya Sentausa CV
Jl. Raya Candi V/752, Malang, , Ph 0341-560 811, Fax 0341-556 256 Ver
TRUSS DETAIL SHEET Job Ref: GLB11
_______________________________________________________________________________
Joint 1 Joint 2 Joint 3 Joint 4

<3> <3,3,3> <3,3> <4>


Joint 5 Joint 6 Joint 7 Joint 8
[3,3]

<3> <3,3> <3> <3,3>

Dimensional limitations(mm)
Edge End Spacing
Dist. Dist.
10g screw 7 14 14
12g screw 8 16 16
Modern Jaya Sentausa CV
Jl. Raya Candi V/752, Malang, , Ph 0341-560 811, Fax 0341-556 256 Ver
TRUSS DETAIL SHEET Job Ref: GLB11
_______________________________________________________________________________
Customer: Pak Anton Site Addr: GreenLand Blok B 11

TRUSS DATA CHORDS WEBS


Truss Type : Mono 1 3 75W80/55 u.o.n 65C80/55
TC pitch 1 : 35.00 6 4 75W80/55 1 6 75W80/55
Lh cut-off : 178 3 5 75W80/55
Thickness : 33 3 4 75W80/55
Spacing : 1200
TC Battens : 350
TC Restraint: 350
BC Restraint: 1700
Timber Group: Steelumba
Building Importance : Residential
Roofing Material : Concrete tile-normal 510 Pa
Ceiling Material : 13mm P/Bd to battens 84 Pa
Overhang design assumes structural fascia.
Truss Mark <M1 > 2 Single Trusses

< > = # screws @ joints, [ ] = # screws @ gussets


Steelfast Truss
All screws 10g 16x16 self drilling hex head

732R 2747R 235R

1215R 1531R 150

124V 821V 1700V

<3>

(1897) o/all4

<3,3>
5

<3,3>

1 2 3

<3> <3,3> <3,3>


(0) (0) camber (0)
3.7 kN React (LSD) 2.8 kN React (LSD)
1/Sldr 1/Sldr

995R 1254R
Modern Jaya Sentausa CV
Jl. Raya Candi V/752, Malang, , Ph 0341-560 811, Fax 0341-556 256 Ver
TRUSS DETAIL SHEET Job Ref: GLB11
_______________________________________________________________________________
Joint 1 Joint 2 Joint 3 Joint 4

<3> <3,3> <3,3> <3>


Joint 5 Joint 6

<3,3> <3,3>
Modern Jaya Sentausa CV
Jl. Raya Candi V/752, Malang, , Ph 0341-560 811, Fax 0341-556 256 Ver
TRUSS DETAIL SHEET Job Ref: GLB11
_______________________________________________________________________________
Customer: Pak Anton Site Addr: GreenLand Blok B 11

TRUSS DATA CHORDS WEBS


Truss Type : T/Gird 1 4 75W80/55 u.o.n 75W80/55
TC pitch 1 : 35.00 4 5 75W80/55
Station : 1200 5 7 75W80/55
Thickness : 33 1 7 75W80/55
Spacing : 1200
TC Battens : 350
TC Restraint: 350
BC Restraint: 1700
Timber Group: Steelumba
Building Importance : Residential
Roofing Material : Concrete tile-normal 510 Pa
Ceiling Material : 13mm P/Bd to battens 84 Pa
Overhang design assumes structural fascia.
Truss Mark <TG1 > 1 Single Truss

< > = # screws @ joints, [ ] = # screws @ gussets


Steelfast Truss
All screws 10g 16x16 self drilling hex head

671R 1334R 142R 2614R 142R 1334R 671R

1333R 1307R 1307R 1333R

765V 765V 765V

<5,3> <3,3> <5,3>

7 6 5(840) o/all

1 2 3 4
<5> <3,3> <3,3> <5>
(0) (2) camber (2) (0)
6.0 kN React (LSD) 6.0 kN React (LSD

1/Sldr 1/Sldr

1746R 1307R 1746R

550 Span 4800 550


Modern Jaya Sentausa CV
Jl. Raya Candi V/752, Malang, , Ph 0341-560 811, Fax 0341-556 256 Ver
TRUSS DETAIL SHEET Job Ref: GLB11
_______________________________________________________________________________
Joint 1 Joint 2 Joint 3 Joint 4

<5> <3,3> <3,3> <5>


Joint 5 Joint 6 Joint 7

<5,3> <3,3> <5,3>

Dimensional limitations(mm)
Edge End Spacing
Dist. Dist.
10g screw 7 14 14
12g screw 8 16 16
Modern Jaya Sentausa CV
Jl. Raya Candi V/752, Malang, , Ph 0341-560 811, Fax 0341-556 256 Ver
TRUSS DETAIL SHEET Job Ref: GLB11
_______________________________________________________________________________
Customer: Pak Anton Site Addr: GreenLand Blok B 11

TRUSS DATA CHORDS WEBS


Truss Type : Valley 1 3 65C80/55 u.o.n 65C80/55
TC pitch 1 : 35.00 3 4 75W80/55
Thickness : 33 1 4 75W80/55
Spacing : 1200
TC Battens : 350
TC Restraint: 350
BC Restraint: 1700
Timber Group: Steelumba
Building Importance : Residential
Roofing Material : Concrete tile-normal 510 Pa
Ceiling Material : 13mm P/Bd to battens 84 Pa
Overhang design assumes structural fascia.
Truss Mark <V1 > 1 Single Truss

< > = # screws @ joints, [ ] = # screws @ gussets


Steelfast Truss
All screws 10g 16x16 self drilling hex head

894R 52R
52R 894R

1007R 1007R

486V

<3>
[3,3]
4(578) o/all

1 2 3

<3> <3> <3>


(0) (0) camber (0)
1.9 kN React (LSD) 1.9 kN React (LSD)

825R 825R

Span 1650
Modern Jaya Sentausa CV
Jl. Raya Candi V/752, Malang, , Ph 0341-560 811, Fax 0341-556 256 Ver
TRUSS DETAIL SHEET Job Ref: GLB11
_______________________________________________________________________________
Joint 1 Joint 2 Joint 3 Joint 4
[3,3]

<3> <3> <3> <3>

Dimensional limitations(mm)

Edge End Spacing


Dist. Dist.
10g screw 7 14 14
12g screw 8 16 16
Modern Jaya Sentausa CV
Jl. Raya Candi V/752, Malang, , Ph 0341-560 811, Fax 0341-556 256 Ver
Detailer:<None> CUTTING DETAILS Job Ref: GLB11
_______________________________________________________________________________
Customer: Pak Anton Site Addr: GreenLand Blok B 11

2 Bottom Chords
75x33 W80/55
1 - 4500 : 1/S2
1 - 2100 : 1/S2
90.00º 90.00º
Length: 4500

9 Bottom Chords
75x33 W80/55
3 - 5150 : 3/S3
2 - 4800 : 1/TG1
90.00º 90.00º
Length: 5150 : 1/S1
2 - 4399 : 2/S4
2 - 2400 : 2/M1
1 Bottom Chord
65x33 C80/55
1 - 1464 : 1/V1

90.00º 90.00º
Length: 1464

1 Horizontal Top Chord


75x33 W80/55
1 - 2614 : 1/TG1

90.00º 90.00º
Length: 2614

18 Top Chords
75x33 W80/55
6 - 4691 : 1/S2
: 3/S3
90.00º 90.00º
Length: 4691 : 2/S4
1 - 4416 : 1/S2
2 - 3714 : 2/M1
2 - 2982 : 2/S1
3 - 2433 : 3/S3
2 - 2147 : 2/TG1
2 - 893 : 2/V1

2 Top Chords

Length: 1517 75x33 W80/55


2 - 1517 : 2/S4
Modern Jaya Sentausa CV
Jl. Raya Candi V/752, Malang, , Ph 0341-560 811, Fax 0341-556 256 Ver
Detailer:<None> CUTTING DETAILS Job Ref: GLB11
_______________________________________________________________________________
Customer: Pak Anton Site Addr: GreenLand Blok B 11

57 Webs
75x33 W80/55
6 -2266 W 3 2/S4
W 4 1/S2
90.00º 90.00º
Length: 2266 W 5 3/S3
10 -1852 W 3 1/S2
W 4 2/S4
W 4 3/S3
W 5 1/S2
W 6 3/S3
2 -1841 W 2 2/S1
2 -1829 W 2 2/S4
2 -1737 W 5 2/M1
2 -1595 W 1 2/S4
10 -1446 W 2 1/S2
W 3 3/S3
W 5 2/S4
W 6 1/S2
W 7 3/S3
2 -1431 W 4 2/M1
3 -1095 W 2 3/S3
3 -1070 W 1 3/S3
1 -1008 W 2 1/TG1
3 - 977 W 1 3/TG1
2 - 964 W 1 2/S1
7 - 937 W 1 1/S2
W 6 2/S4
W 7 1/S2
W 8 3/S3
2 - 214 W 1 2/M1

5 Webs
65x33 C80/55
2 - 913 W 2 2/M1
2 - 888 W 3 2/M1
90.00º 90.00º
Length: 913 1 - 511 W 1 1/V1