1. Which type of DIMMs are supported by the M7 processor?

DDR4 (*)

2. How many DIMM slots are supported by the M7 processor?


16 (*)

3. Which statement is true?


The SPARC M7 processor uses the fourth generation CMT Core, referred to as S4 (*)

4. How many virtual CPUs can the M7 support considering that each thread can be
a virtual CPU?
256 (*)

5. Which three statements are true about M7 processors?


Each M7 processor provides coherency links, referred to as CLINKs (*)
CLINKS are used on both the M7 and T7 servers (*)
CLINKS provide for inter-processor connections (*)

6. How does the M7 processor implement SSM within its silicon?


By implementing 8 DAX units to function as co-processors (*)

7. How many layers of cache does the SPARC M7 processor have?


4 (*)

8. Which response is the definition of a DAX?


A co-processor with the M7 processor that offloads the data compression and
decompression functions from the software threads (*)
A memory control unit chip outside of the M7 processor (*)

9. What is the total amount of level 3 cache that the M7 processor supports?
64 Mbytes (*)

10. Which two features are part of the SPARC M7 processor�s power management
features ?
Dynamic Voltage Frequency Scaling (*)
power gating (*)

11. Which type of link is an inter-processor cache coherent connection?


CLINK (*)

12. Which systems use the SPARC M7 processor?


SPARC T7-2 (*)
SPARC T7-4 (*)
Oracle SuperCluster M7 (*)

13. Which is the function of the Mystic River ASIC?


I/O Hub (*)

14. What enhancements to the SPARC M7 processor contribute to security at all


layers of the stack?
Improvements to on-chip cryptography (*)

15. What is the maximum memory configuration in a SPARC T7-4 server?


64 DIMM slots (*)

16. Which can fail, yet allow the T7 servers continue to operate and power on?
Single power supply (*)

17. What are two benefits of DIMM sparing?


1 out of 16 DIMMs per socket can be spared (*)
Migration of contents from failing DIMM takes place, with no visible impact on
performance (*)

18. What is the benefit of VersaBoot?


Boots Solaris's root filesystem from firmware-inaccessible storage (*)

19. How many processor chips does the SPARC T7-4 server have?
4 SPARC M7 32-core 4.13Ghz CPUs (*)

20. How many processor chips does the SPARC T7-2 server have?
2 SPARC M7 32-core 4.13Ghz CPUs (*)

21. Which can fail, yet allow the T7 servers continue to operate?
Single fan and and single power supply (*)

22. What is the maximum memory configuration in a SPARC T7-1 server?


16 DIMM slots with memory mezzanine (*)

23. In which two ways does being glueless impact the SPARC T7-2 and T7-4
servers?
The processors are directly connected (*)
The system directory is fine-grain interleaved in processors (*)

24. Which components are located in a single T7-4 server processor module?
2 CPUs, 32 DIMM slots, 12 BoBs (*)

25. Which three statements are true?


The SPARC T7-1 is the replacement for the SPARC T4-1 server (*)
The SPARC T7-2 is the replacement for SPARC T5-2 server (*)
SPARC T7-4 is the replacement for the SPARC T5-4 server (*)

26. Which components are located in a T7-4 server main module?


8 drive bays, 4 IOHs, server processor module (*)

27. How many processor chips does the SPARC T7-1 server have?
1 SPARC M7 32-core 4.13Ghz CPU (*)

28. What is the maximum memory configuration in a SPARC T7-2 server?


32 DIMM slots with memory risers (*)

29. What is the recommended number of people to install a SPARC T7 server?


2 (*)

30. Select two ways the boot process been enhanced from the conventional boot
process with the SPARC T7?
VersaBoot, where the server is booted via a firmware-inaccessible storage device,
iSCSI or eUSB (*)
Fallback Boot, where the server is booted via an image stored on the SP (*)

31. What do you type to login to the SP in a SPARC T7 server?


Root and changeme (*)

32. What is a key benefit of Automated Service Request (ASR)?


ASR software resolves problems faster by automatically opening service requests for
Oracle's qualified server products when specific faults occur (*)

33. What do you type to power on a SPARC T7server?


Start / system (*)
34. What is the password for root in your initial SP login?
changeme (*)

35. When installing a SPARC T7 server in a rack you should?


Load servers into a rack from the bottom up (*)

36. What are two options that can function as a systems console during the SPARC
T7 installation?
ASCII terminal (*)
Workstation (*)

37. Which resource are you required to use at a customer site for server
installation?
EIS Installation Checklists (*)

38. What are three standard safety precautions to remember when installing any
SPARC T7 Server?
Always load servers into a rack from the bottom up so that it will not become top
heavy and tip over. (*)
Installation requires two people and a lift. (*)
Deploy the anti-tilt bar on the equipment rack before beginning an installation.
(*)

39. How can you boot a SPARC T7 server?


Using all of these options (*)

40. What is the CMA?


Cable Management Arm (*)

41. Which one of these SPARC T7 server installation steps are in the correct
order?
Prepare terminal access, turn on power to the SP, monitor the boot process via
ILOM, and power on the server and set up the operating system. (*)

42. To remove the T7-4 rear chassis sub assembly you must:
Remove the front components, remove the rear components, remove the screws that
secure the RCSA to the chassis from the front, pull the RCSA from the rear. (*)

43. Which three of these T7-2 server components are FRUs?


Motherboard (*)
Fan cage assembly (*)
Power supply backplane (*)

44. In the T7-4 where is the eUSB is located?


On the rear IO board (*)

45. Which two of these T7-4 server components are FRUs?


Cable kit (*)
Processor module (*)

46. In the T7-2, to remove the fan cage assembly, you must:
Remove the memory risers, remove the fans, remove the cables, remove the screws
that secure memory riser guide and pull it up out of the server, pull the fan cage
assembly up out of the server. (*)

47. Which three of these T7-1 server components are CRUs?


SAS SSD (*)
PCIe card (*)
Memory mezzanine (*)

48. Which three of these T7-4 server components are CRUs?


Main module (*)
Rear IO module (*)
Processor module (*)

49. In the T7-2, to remove the power supply backplane, you must:
Remove the memory risers, the air baffle, the power supplies, the power supply
ribbon cable and cover, and the bus bar screws. (*)

50. Which three of these T7-1 server components are FRUs?


DVD drive (*)
Motherboard (*)
Disk backplane (*)

Вам также может понравиться