DDR4 (*)
4. How many virtual CPUs can the M7 support considering that each thread can be
a virtual CPU?
256 (*)
9. What is the total amount of level 3 cache that the M7 processor supports?
64 Mbytes (*)
10. Which two features are part of the SPARC M7 processor�s power management
features ?
Dynamic Voltage Frequency Scaling (*)
power gating (*)
16. Which can fail, yet allow the T7 servers continue to operate and power on?
Single power supply (*)
19. How many processor chips does the SPARC T7-4 server have?
4 SPARC M7 32-core 4.13Ghz CPUs (*)
20. How many processor chips does the SPARC T7-2 server have?
2 SPARC M7 32-core 4.13Ghz CPUs (*)
21. Which can fail, yet allow the T7 servers continue to operate?
Single fan and and single power supply (*)
23. In which two ways does being glueless impact the SPARC T7-2 and T7-4
servers?
The processors are directly connected (*)
The system directory is fine-grain interleaved in processors (*)
24. Which components are located in a single T7-4 server processor module?
2 CPUs, 32 DIMM slots, 12 BoBs (*)
27. How many processor chips does the SPARC T7-1 server have?
1 SPARC M7 32-core 4.13Ghz CPU (*)
30. Select two ways the boot process been enhanced from the conventional boot
process with the SPARC T7?
VersaBoot, where the server is booted via a firmware-inaccessible storage device,
iSCSI or eUSB (*)
Fallback Boot, where the server is booted via an image stored on the SP (*)
36. What are two options that can function as a systems console during the SPARC
T7 installation?
ASCII terminal (*)
Workstation (*)
37. Which resource are you required to use at a customer site for server
installation?
EIS Installation Checklists (*)
38. What are three standard safety precautions to remember when installing any
SPARC T7 Server?
Always load servers into a rack from the bottom up so that it will not become top
heavy and tip over. (*)
Installation requires two people and a lift. (*)
Deploy the anti-tilt bar on the equipment rack before beginning an installation.
(*)
41. Which one of these SPARC T7 server installation steps are in the correct
order?
Prepare terminal access, turn on power to the SP, monitor the boot process via
ILOM, and power on the server and set up the operating system. (*)
42. To remove the T7-4 rear chassis sub assembly you must:
Remove the front components, remove the rear components, remove the screws that
secure the RCSA to the chassis from the front, pull the RCSA from the rear. (*)
46. In the T7-2, to remove the fan cage assembly, you must:
Remove the memory risers, remove the fans, remove the cables, remove the screws
that secure memory riser guide and pull it up out of the server, pull the fan cage
assembly up out of the server. (*)
49. In the T7-2, to remove the power supply backplane, you must:
Remove the memory risers, the air baffle, the power supplies, the power supply
ribbon cable and cover, and the bus bar screws. (*)