Академический Документы
Профессиональный Документы
Культура Документы
Preparation (Modules)........................................................................................................................................ 20
Planning the System Configuration .........................................................................................................20
S2M Module Overview (COMmander S2M Module, COMmander S2M R Module) ...................................20
Setting the Operating Voltage for the NTPM ......................................................................................21
S0 Module Overview (COMmander 4S0 Module (Rev. 3),
COMmander 4S0 R Module, COMmander 8S0 (R) Module) ...................................................................21
Changing the Operating Mode for Switchable Ports...........................................................................22
Switching Terminators ........................................................................................................................22
VoIP and VMF Module Overview (COMmander 8VoIP (R) Module,
COMmander 16VoIP (R) Module, COMmander VMF (R) Module) .........................................................23
Changing Memory Card......................................................................................................................23
8UP0 Module Overview (COMmander 8UP0 / 8UP0 R Module) ...............................................................24
8a/b Module Overview (COMmander 8a/b / 8a/b R Module) ..................................................................24
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 3
Table of Contents
4 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Table of Contents
Commissioning................................................................................................................................................... 49
Turning on the PBX .................................................................................................................................49
Opening Configuration Manager of the PBX via PC with Permanent IP Address from the
APIPA Address Range ............................................................................................................................49
Opening Configuration Manager of the PBX via PC in the Same Network .............................................50
Transmitting the safety certificate alert for Internet Explorer 8.0 .............................................................51
Transmitting the safety certificate alert for Mozilla Firefox 4.0 ................................................................51
Configuring Basic Settings ......................................................................................................................51
System Activation ....................................................................................................................................52
Connecting the PC to the Ethernet Port ..................................................................................................53
Configuring the Static IP Address in the PC ............................................................................................53
Changing the Ethernet Configuration on the PBX ..............................................................................53
Querying the Ethernet configuration on the PBX ................................................................................54
Putting Analogue End Devices into Operation ........................................................................................54
Putting ISDN System Telephones into Operation ...................................................................................54
Putting Standard ISDN End Devices into Operation ...............................................................................55
Putting VoIP System Telephones into Operation ....................................................................................55
Putting Standard VoIP End Devices into Operation ................................................................................55
Configuration Manual........................................................................................................................................ 56
Example 1: Basic Configuration with Int. Subscribers and Call Distribution .......................................56
Logging into the Configuration Manager ........................................................................................57
Hardware Configuration .................................................................................................................57
IP Configuration..............................................................................................................................57
Port Configuration ..........................................................................................................................58
Internal Telephone Numbers..........................................................................................................59
External Telephone Numbers.........................................................................................................61
Call Distribution ..............................................................................................................................65
End of Basic Configuration.............................................................................................................66
Testing Basic Configuration ...........................................................................................................66
Example 2: Time-dependent Configurations (PBX Profiles) ...............................................................68
Time-dependent Switching (Time Control).....................................................................................69
Configuring Configuration-dependent settings ...............................................................................70
Index ...................................................................................................................................................................... 72
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 5
Important Information
Important Information
This section includes necessary information for operating the devices safely. Before installing and commissioning the PBX, be
sure to read the safety information listed here. Also become familiar with the proper use of the device as well as the technical data.
Safety Information
Warning: Improper handling of the device can result the fixing components of the front plate where
in life-threatening electrical shock and can damage or necessary. Do not insert any electrically conduc-
destroy the PBX. tive objects into the casing, since hazardous vol-
씮 Only a qualified electrician may open the casing. tages continue to apply in the power supply unit of
If necessary, have an authorised dealer commis- the system.
sion the device. 씮 Remove any voltage from the device by dis-
씮 Only a qualified electrician may perform charging any capacitors present, if necessary. In
installation work within an open casing or service the case of a malfunction, the electrolytic capaci-
work using the buttons inside the casing. If tor for the switch-mode power supply can remain
necessary, commission an authorised dealer to charged for a long time even after being turned
perform this work. off.
씮 Read the instructions for the device and keep 씮 If available, also disconnect the devices from
them for future reference. auxiliary power sources (for example, UPS).
씮 Do not make any structural changes to the device
Warning: Touching voltage-carrying conductors or (exception: COMmander 6000R Xtension).
telephone connections may cause a life-threatening
electric shock. 씮 COMmander 6000R: When commissioning a
qualified electrician to upgrade a COMmander
씮 Mount the PBX in the immediate vicinity of an 6000R PBX with the COMmander 6000R
earth wire (potential compensation bar of the Xtension extension set, the power plug must be
house installation). Connect the earth connection unplugged by all means before starting the
of the PBX to the earth wire via a connecting cable assembly. It does not suffice to push the Power
with at least 2.5 mm². button.
씮 The PBX contains hazardous voltages, even out- Only mount the components in a voltage-free
side of the power supply unit (for instance ringer state.
voltages). Work on active, contact-hazardous 씮 COMmander 6000R: After having a COMmander
parts is only permitted after creating a voltage- 6000R with the COMmander 6000R Xtension
free state. extension set upgraded by a qualified electrician,
Working close to active parts is only permitted if the safety of the device has to be checked accord-
these parts are voltage-free or are protected ing to DIN VDE 0701-0702: 2008 or applicable
against direct contact. national regulations.
씮 COMmander 6000: Pull out the power plug of the 씮 For some installation and maintenance work, it is
PBX before commissioning a qualified electrician necessary to open the PBX while it is in operation
to open the casing to install the expansion module (qualified electrician only). Make sure that the
or perform switching or connecting services. PBX is never left unattended while working with
씮 COMmander 6000R/RX: The Power button swit- an open casing.
ches the voltage at the module expansion slots 씮 Be sure to follow the relevant regulations when
and on the main circuit board off. If the system is handling 230 V system voltage and devices
switched off, a qualified electrician can be com- attached to the mains.
missioned to replace or install expansion
modules. 씮 Only operate the device when the casing is
When installing or replacing a module, only touch closed.
6 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Important Information
씮 Only operate the device when it is mounted on the 씮 COMmander 6000R/RX: Make sure not to cover
wall (COMmander 6000) or securely fastened in a the fan on the rear side of the casing.
19" rack (COMmander 6000R/RX).
Caution: Electrostatic charges can destroy sensitive
Warning: Liquid penetrating the casing may cause a components.
life-threatening electric shock and can damage or 씮 Divert electrostatic charges from yourself before
destroy the PBX. touching the circuit boards with your hands or any
씮 Only operate PBX in closed, dry rooms. tools. To do this, touch a metal object, preferably
씮 Only clean the device with a soft moist cloth or earthed, e. g. the earthing terminal of the PBX or
anti-static cloth. a computer housing.
Warning: Damaged connection lines as well as Important: Mechanical loads and electro-magnetic
damage to the casing and to the PBX can cause life- fields can impair PBX operation.
threatening electrical shocks. 씮 Avoid mechanical loads (for example, vibrations).
씮 Only connect the device connection cable with 씮 Avoid proximity to devices that generate electro-
sockets that are designed for that purpose. magnetic fields or react sensitively to them (e. g.
씮 Make sure that the Schuko socket for connecting radio receivers, private mobile radio devices,
the PBX is properly connected (according to VDE amateur radio sets, mobile phones, DECT
0100). The power socket must be located near the systems, or similar).
PBX and be freely accessible at all times. 씮 Do not expose the device to direct sunlight or
씮 Replace damaged connection lines immediately. condensation.
씮 Use original components and original spare parts 씮 Protect the device from soiling, excessive dust
only. and condensation.
씮 Always have a professional carry out repairs 씮 Note the values for ambient temperature and
immediately. Please contact your qualified electri- humidity indicated in the technical data.
cian or the manufacturer directly. Important: A power failure, damaged connection
Warning: Power surges, which can occur during lines/cable sockets or short-circuits in other devices
electrical storms, can cause life-threatening electric in the building systems can put the PBX out of
shocks and can damage or destroy the PBX. operation.
씮 For this reason, do not mount the PBX during an 씮 If you have uninterruptible power supply,
electrical storm. Avoid disconnecting and con- for example, the UPS-5115 Telecom (Auerswald
necting lines during an electrical storm. optional accessory), you can continue operating a
large part of the system during a power failure.
씮 Let a qualified electrician lay all the cables inside
the building – including the cable to the door 씮 If at all possible, be sure to provide a separate
terminal system. electric circuit for the 230 V connection supplying
the PBX.
씮 Protect the devices by installing overvoltage
protection. Important: Make sure to take suitable measures for
protecting your data and yourself from misuse.
Caution: Unauthorised changes to the device can
damage the PBX or breach security and EMC regula- 씮 Prevent unauthorized access to the PBX and its
tions. If security-relevant radio services are disturbed, programming.
the Federal Network Agency can order decommis- 씮 Never disclose user names, PINs, or the public IP
sioning the device according to §14, section 6, Elec- address of the PBX. This does not only concern
tromagnetic Compatibility Act. postings in forums or communities, but also to
씮 Always have a professional carry out repairs. service logs of routers and Wireshark traces.
Please contact your qualified electrician or the 씮 It is important to consistently use all of the
manufacturer directly. available options for assigning passwords. Do not
씮 The memory card of the PBX contains data which use passwords which are easy to guess, such as
is necessary for the operation of the PBX. Do not birthdays.
remove, mount, or format the memory card. The 씮 Make use of the permissions available (pro-
memory card on the base circuit board should gramming authorization, exchange line authoriza-
only be exchanged in the case of service jobs tions, restricted numbers, etc.).
according to the directives of Auerswald service 씮 Check the call data recording of your PBX and the
staff. LOGs of your NAT router regularly for incon-
Caution: Exceeding (even temporarily) the threshold sistencies.
values indicated in the technical data can damage or 씮 Additional information about protecting the
even destroy the PBX. system from misuse can be found in the internet
씮 Note the threshold values indicated in the techni- on the pages of the German Federal Office for
cal data for voltage, electricity, performance, am- Information Security (see www.bsi.bund.de with
bient temperature and humidity. search term = TK-Anlagen).
씮 COMmander 6000: Never cover the vent slots of
the wall casing.
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 7
Important Information
Proper Use
Important: Auerswald products are not designed, There may be some incompatibility in combination
manufactured, or intended for use or resale in with terminals and devices of other vendors that
environments requiring fail-safe performance, such adversely influence the usability of functions.
as in the operation of life-support systems and/or
nuclear facilities. Use or sale of our products for these Note: After a firmware update you usually require a
purposes is only allowed with prior written permission new version of the instructions. Current instructions
by Auerswald for each individual incident. can be found in the internet (see www.auerswald.de
under Service > Products > COMmander 6000 >
Improper use may cause, for example, functional
Documentation).
restrictions or interference, the destruction of the
device or, in a worst case scenario, personal injury.
씮 If you are still uncertain about how to use the External S2M Port
product properly after reading the section below,
please contact your specialised dealer. An external S2M port (not included in the basic assembly)
is designed for connecting to an NTBA using the
씮 Read the instructions for the device and keep
European protocol DSS1 (Euro ISDN). It supports the
them for future reference.
connection type PBX connection. The S2M port provides a
The COMmander 6000, COMmander 6000R and COM- total of up to 30 B-channels. The channels can configured
mander 6000RX devices are telecommunication systems to be directionally dependent (incoming, outgoing or
– referred to as PBXs in the following. These PBXs con- incoming and outgoing).
nect various internal devices with various public telecom-
munication networks, thereby enabling external and inter-
nal calls. For this purpose, the PBXs provide a number of PMP Port
different ports/interfaces.
The PMP port (not included in the basic assembly) is a
These PBXs are structured modularly. The various Protected Monitor Point, based on ITU-T G.772 and ITU-
modules available allow the systems to be extended step T G.703. It is used for transparent protocol measurement
for step depending on how many subscriber connections during NTPM operation. It is suitable for connecting
and ports are required and whether a door terminal measurement devices that support transparent listening
system should be operated from each telephone. in.
The COMmander 6000 is a PBX with a plastic casing
available for wall mounting. The COMmander 6000R and External S0 Port
COMmander 6000RX are PBXs with 19" casings
available for installation in a 19" rack. An external S0 port (not included in the basic assembly) is
designed for connecting an NTBA to the European
The PBXs are suitable for used in the commercial sector protocol DSS1 (Euro ISDN). It supports the following
(midsize companies). The 1COMmander 6000R/RX are connection types:
suitable for use in structured IT/telecommunication
networks.
쐽 Basis access as a PBX connection
쐽
Basis access as a Point-to-Multipoint connection
PBXs have numerous features, including performing the
following tasks: Note: On the NTBA with PBX unit connection, only
쐽 Call Distribution one ISDN device may be operated, in this case, only
the PBX. All other ISDN devices are operated as
쐽
Ensuring availability
internal subscribers of the PBX.
쐽
Charge and call data evaluation On the NTBA with a Point-to-Multipoint connection,
쐽 Cost control other ISDN devices may be operated in addition to
쐽
Central call answering machine (voice mail) and the PBX. If the NTBA is equipped with a 230 V power
fax memory cable and in addition to the PBX, passive devices are
쐽
Group and team administration connected to the NTBA, the NTBA must be con-
nected with a 230 V power socket.
쐽
Transfers
쐽 Call protection Furthermore, it is possible to connect to a digital GSM
gateway.
Important: Many features are not available until they
are set up via the PBX configuration manager.
In order to use of some of the features, it is necessary Ethernet Port
to contact the network provider about activating the
feature. The devices to be connected to the Ethernet port are
dependent on their intended application. The applications
In order to use some of the functions, these have to
listed at the end do not exclude each other.
be released in the Upgrade Center.
In order to use some of the functions, it is necessary For Internet telephony (VoIP), the Ethernet port can be
to extend the hardware. connected to the Internet via a router. The PBX can
manage 100 VoIP accounts for up to 20 different VoIP
8 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Important Information
providers: The PBX supports two different types of VoIP Internal S0 Port
account:
An internal S0 port has similar requirements, such as an
쐽 VoIP accounts with one or more VoIP phone ISDN connection with the Point-to-Multipoint connection
numbers (similar the Point-to-Multipoint type and is suitable for connecting to the following end
connection on ISDN) devices:
쐽
VoIP accounts with a DDI number block (similar to 쐽
COMfortel 1600/2600 system telephones
the PBX connection on ISDN) based on the SIP-
DDI feature (also known as SIP trunking) Important: To support the COMfortel 1600/2600, the
PBX requires firmware version 5.4B or higher.
For internal IP telephony, VoIP end devices can be con-
nected to the Ethernet port via a switch/router. 쐽
COMfortel 1100/1500/2500/2500 AB system
telephones (as of firmware version 4.4E)
The Ethernet port is suitable for connecting the following
end devices (system telephones recommended):
쐽
COMfortel DECT 900 Bases for COMfortel DECT
900C/900
쐽 COMfortel 3500 system telephones 쐽
ISDN telephones in compliance with the Euro
Important: To support the COMfortel 3500, the PBX ISDN Standard (DSS1)
requires firmware version 5.4 or higher. 쐽
ISDN PC controller in compliance with the Euro
ISDN Standard (DSS1)
쐽 COMfortel VoIP 2500 AB system telephones (as of
firmware version 4.4E) Important: The power consumption of the end
쐽 COMfortel DECT IP1040 Bases for COMfortel devices on an S0 port may total a maximum of 4 W. A
DECT 900C and some GAP capable DECT maximum of 160 W is available for all the a/b-, S0-
handsets from other manufacturers (further und UP0 ports together.
information can be found in the internet (see
www.auerswald.de )
쐽 Standard VoIP telephones (SIP) Internal UP0 Port
쐽
Soft phones (SIP) An internal UP0 port is a 2-core interface that, for example,
becomes useful if existing 2-core lines in an analogue
Important: Note that many standard VoIP tele- installation should be used. It is suitable for connecting
phones can only use the functions on the PBX to a one of the following end devices:
limited extent.
쐽
COMfortel 1600/2600 system telephones
For configuration/administration, the Ethernet port can be
connected to a separate PC connected or to a local net- Important: To support the COMfortel 1600/2600, the
work (LAN). PBX requires firmware version 5.4B or higher.
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 9
Important Information
쐽
Analogue telephones with pulse dialling 쐽
Active loudspeakers
쐽 Analogue fax machines 쐽 Music output devices (for example, MP3 or CD
쐽
Analogue answering machines players)
쐽
Modems
쐽 a/b door terminal systems (e. g. TFS-Dialog 300 USB Host Port 2.0
from Auerswald
The USB port is suitable for connecting a single external
Important: Devices using pulse dialling cannot use printer.
the full range of features.
Devices using multi-frequency (DTMF/tone) dialling
must be equipped with a flash button. Basic Assembly
A maximum of 160 W is available for all the a/b-, S0-
und UP0 ports together. The basic assembly on the PBXs includes the following
connection options:
Note: When using a T-Net-capable analogue 쐽 1 Ethernet port for administration as well as
telephone, most T-Net functions can be used via the internal IP and Internet telephony over two
existing function keys on the telephone. external VoIP channels (SIP-compliant according
to RFC 3261, VoIP Codec G.711 µ-Law/a-Law)
Switching Relay
쐽
1 USB host port for connecting a single external
printer
A switching relay (not included in the basic assembly) is
suitable for connecting or controlling the following Important: Operating the PBX without modules and
devices: Systemfreischaltung is not possible.
쐽
Door terminal system according to FTZ 123 D12-0
(for example, TFS Dialog 100 from Auerswald) Hardware Extensions
쐽
Door opener
The PBXs have variable module slots for the following
쐽 Various devices to be switched (for example,
modules (COMmander 6000 five module slots; COM-
alarm sirens)
mander 6000R five module slots (extendable to 15);
Important: The module supplies no switching volt- COMmander 6000RX 15 module slots):
age to the relay contacts, meaning the devices to be 쐽
COMmander S2M (R) module – this is for
switched must be supplied with external voltage. extending the PBX by adding an external S2M port
as well as a PMP port for protocol measurement.
Caution: The relay contacts can handle a maximum
load of 30 V/1 A (therefore, not suitable for a direct
쐽 COMmander 4S0 (R) module – this is for extending
connection to 230 V system voltage). the PBX by adding four S0 ports, separately
switchable between S0 external and S0 internal.
씮 For switching devices operated on voltage, you
therefore need an additional load-switching relay
쐽
COMmander 8S0 (R) module – for extending the
that is compatible with the safety regulations. PBX by adding eight S0 ports, four of which
separately switchable between S0 external and S0
internal; four additional ones are permanently set
Ringer/Alarm Input to S0 internal.
쐽
COMmander 8UP0 (R) module – for extending the
A ringer/alarm input (not a part of the basic assembly) is
PBX by adding eight internal UP0 ports.
suitable for connecting or controlling the following
devices:
쐽
COMmander 8a/b (R) module – for extending the
PBX by adding eight internal analogue ports.
쐽
Door bell button 쐽
COMmander 2TSM (R) module – for extending the
쐽
Output devices for announcement, alarm and PBX by adding two door terminal ports (FTZ 123
monitoring signals (for example, leak warning D12-0), six switching relays, for ringer/alarm
devices) inputs, a second ringer output, a music input and
an audio output.
Second Ringer Output
쐽
COMmander 8VoIP (R) module – use this to
extend the PBX with eight VoIP channels as well
A second ringer output (not included in the basic assem- as with the VoIP Codecs G.723.1, G.726, G.729A/
bly) is suitable for connecting to an external ringer (not a E and iLBC.
house door bell) for additional signalling. 쐽 COMmander 16VoIP (R) module – use this to
extend the PBX with 16 VoIP channels as well as
with the VoIP Codecs G.723.1, G.726, G.729A/E
Music Input/Audio Output and iLBC.
A music input/audio output (not included in the basic 쐽
COMmander VMF (R) module – use this to extend
assembly) is suitable for connecting or controlling the the PBX with 40 voicemail and 40 fax boxes as
following devices: well as eight simultaneously available voicemail/
쐽
Loudspeaker units fax channels.
10 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Important Information
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 11
Important Information
쐽
COMmander S2M R module: 1 Accessories and service parts can be bought at
쐽 COMmander 4S0 R module: 12 specialised stores or in the Internet shop distriCOM at
쐽
COMmander 8S0 R module: 9 http://www.districom.de. (Delivery is provided only in
Germany and Austria.)
쐽
COMmander 8UP0 R module: 9
쐽 COMmander 8a/b R module: 8
쐽
COMmander VMF R module: 1 Configuration/Administration
쐽
COMmander 2TSM R module: 4 The configuration manager on the PBX is contained in the
Note: For a table showing extension limits and point integrated web server and can be opened with a browser.
system, refer to Page 15. This prevents the need to install special programmes on
the computer. You need only an IP-supported operating
system and a compatible browser.
Installation The configuration manager enables you to do the follow-
The PBXs are intended to be operated in closed rooms. In ing tasks:
addition, all of the devices connected to the system must 쐽
Configure the PBX
be located in the building. 쐽 Manage call data
The PBXs enable you to connect some devices directly, 쐽
Manage the recorded voice and fax messages
inasmuch as they are close enough to the PBX. The dis- 쐽
Manage telephone book entries
tance depends on the length of the equipment connection 쐽 Manage wake-up times
cables up to a maximum of 10 m. 쐽
Manage call allowance accounts
If no suitable connection sockets are available or are too 쐽
Manage internal hold music/announcements
far away, you must lay the installation cable permanently. 쐽 Manage data for Least Cost Routing
Warning: Power surges, which can occur during 쐽
Service and maintenance
electrical storms, can cause life-threatening electric
In order to limit the tasks the operator or user must
shocks.
perform, the configuration manager is divided according
씮 Let a qualified electrician lay all the cables inside to three authorisation levels:
the building – including the cable to the door 쐽
Administrator (admin)
terminal system.
쐽 Sub-administrator (sub-admin)
Note: The terminal clamps on the modules are 쐽
User
removable to facilitate installation.
For the COMmander 6000R/RX, no connections are Note: Telephony has always the highest priority in a
made directly to the module itself but rather on the PBX system, even under heavy load conditions.
front panel. Under heavy traffic it might happen that some of the
web pages of the configuration manager are not
responding as fast as usual.
Technical Data
12 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Important Information
PC and LAN as well as 2 Ethernet ports Charge pulse configurable: 12/16 kHz
a connection to the Impedances a/b symmetrical
basic unit
Memory card 1 SD card slot
Internal S0 Port
Connection unit COMmander 6000: removable spring clamp
Connection Options on the COMmander S2M (R) Module connection (4-core), on 2 ports per module,
ISDN external 1 external S2M port optional RJ-45 socket
Measuring device 1 PMP port COMmander 6000R/RX: RJ-45 socket
Connection type S0 basis access as Point-to-Multipoint
connection, EURO-ISDN (DSS1), short
Connection Options on the COMmander 4S0 (R) Module passive bus
ISDN internal/external 4 S0 ports, optionally switchable as an Supply voltage 40 V + 5% / – 15%
internal or external S0 port (jumper)
Feeder max. 4 W
End devices max. 2 end devices recommended (max. 8
Connection Options on the COMmander 8S0 (R) Module ISDN end devices, of which max. 2 end
ISDN internal/external 8 S0 ports, 4 of which are optionally devices without separate power feed,
switchable as an internal or external S0 port for example, different ISDN telephones)
(jumper); another 4 are permanently set as Range max. 150 m with typical telephone or
internal S0 ports network cable (twisted-pair) for bus setup;
European standards ENV 41001
Connection Options on the COMmander 8UP0 (R) Module [DINV 41001] and EN 28877 apply to IAE-
termination technology)
ISDN internal 8 UP0-ports
Terminators 100 액, switchable; factory settings on
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 13
Important Information
Range max. 100 m Input voltage configurable: 0 V or 5-15 VAC/DC via the
Terminating resistor 120 펂 door bell button (NC)
Active state Contact is closed for more than 0.5 s.
PMP Port
Connection unit removable spring clamp connection (4-core) Second Ringer Output
Interface 10/100 Base-T (10/100 Mbit/s, RJ-45 Connection unit Cinch connector
twisted-pair), Output level max. 1 Veff
VoIP standard SIP according to RFC 3261 Output resistance 600 펂
VoIP codecs on the G.711
exchange line with VoIP module: G.711, G.723.1, G.726, Music Input
G.729 A/E, iLBC
Connection unit Cinch connector
VoIP codecs, internal G.711
with VoIP module: G.711, iLBC Input level adjustable from -18 to +10 dB (1 Veff)
End devices More than 1 end device per internal VoIP Input resistance Depending on level setting, 25 to 50 k액
channel (overcommitment)
Further Information
USB Host for a Printer Connection Cabinet COMmander 6000: plastic, three piece, consisting
Connection unit USB A socket of mounting frame, mounting rack and cover
COMmander 6000R/RX: closed 19‘‘ plug-in
Interface USB (high speed, V2.0) module, 6 HE, IP 20 rating
Dimensions Basic unit COMmander 6000: 220 mm x 357 mm x
SD card slot (W x H x D) 142 mm
Interface SD or SDHC memory card Basic unit COMmander 6000R/RX: 483 mm x 265
Linux partitions mm x 245/285 mm with handle (installed depth
approx. 300 mm as of the front panel incl. cable
delivered card 2 GB entry in the rear)
COMmander 8VoIP module: 293 x 97 x 20 mm
COMmander 16VoIP module: 293 x 97 x 20 mm
Power Supply Outlet
COMmander S2M module: 293 x 70 x 16 mm
Connection unit removable spring clamp connection (2-core) COMmander 4S0 module: 293 x 98 x 18 mm
Output voltage 12 VDC, 100 mA per door station COMmander 8S0 module: 293 x 98 x 18 mm
COMmander 8UP0 module: 293 x 98 x 18 mm
COMmander 8a/b module: 293 x 98 x 15 mm
Door Terminal Input/Output COMmander 2TSM module: 293 x 80 x 15 mm
Connection unit removable spring clamp connection (2-core) COMmander VMF module: 293 x 97 x 20 mm
COMmander 8VoIP R module: 263 x 146 x 25 mm
Interface FTZ 123 D12-0 COMmander 16VoIP R module: 263 x 146 x 25 mm
COMmander S2M R module: 263 x 146 x 25 mm
Relay Outputs COMmander 4S0 R module: 263 x 146 x 25 mm
COMmander 8S0 R module: 263 x 146 x 25 mm
Connection unit removable spring clamp connection (4 x 2- COMmander 8UP0 R module: 263 x 146 x 25 mm
core and 2 x 3-core) COMmander 8a/b R module: 263 x 146 x 25 mm
Type of contact potential-free, 4 operating current contacts COMmander 2TSM R module: 263 x 146 x 25 mm
(NC), 2 operating and quiescent current COMmander VMF R module: 263 x 146 x 25 mm
contact (NC and NO)
Contact load capacity max. 30 V/1 A
Ringer/Alarm Inputs
Connection unit removable spring clamp connection (4 x 2-
core)
14 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Important Information
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 15
Important Information
Expansion Examples
Description Module (point value)a S0 ports UP0 a/b VoIP Other in/outputs
ports ports channels
Not fully expanded, analog/dig- 3 x 8S0 -R module (48) 1-12 external 24 24 2 (internal –
ital balanced 3 x 8a/b-R module (24) 12-23 internal and exter-
3 x 8UP0 -R module (48) nal)
(= 120)
Not fully expanded analog/dig- 1 x S2M -R module (32) (S2M external) 24 16 2 (internal –
ital balanced 3 x 8S0 -R module (48) 0-4 external and exter-
+ S2M exchange line connec- 2 x 8a/b-R module (16) 20-24 internal nal)
tion 3 x 8UP0 -R module (48)
(= 144)
Complete expansion, focus on 6 x 8S0 -R module (96) 1-16 external 8 64 2 (internal –
analog 8 x 8a/b-R module (64) 32-47 internal and exter-
1 x 8UP0 -R module (16) nal)
(= 176)
Complete expansion, focus on 1 x S2M -R module (32) (S2M external) – 64 2 (internal 2 door terminal ports, 4 ringer
analog + S2M exchange line 5 x 8S0 -R module (80) 0-4 external and exter- inputs, 6 switching relays, 1
connection 8 x 8a/b-R module (64) 36-40 internal nal) audio input, 1 audio output
1 x 2TSM-R analog module (4)
(= 180)
Complete expansion, focus on 9 x 8S0 -R module (144) 1-16 external – 40 2 (internal 2 door terminal ports, 4 ringer
S0 5 x 8a/b-R module (40) max. 56 internal and exter- inputs, 6 switching relays, 1
1 x 2TSM-R analog module (4) nal) audio input, 1 audio output
(= 188)
Complete expansion, focus on 1 x S2M -R module (32) (S2M external) – 32 2 (internal 2 door terminal ports, 4 ringer
S0 + S2M exchange line con- 7 x 8S0 -R module (112) 0-4 external and exter- inputs, 6 switching relays, 1
nection 1 x 4S0 -R module (8) max. 56 internal nal) audio input, 1 audio output
4 x 8a/b-R module (32)
1 x 2TSM-R analog module (4)
(= 188)
Complete expansion, focus on 1 x 8S0 -R module (16) 1-8 external 72 24 2 (internal 2 door terminal ports, 4 ringer
UP0 3 x 8a/b-R module (24) 0-7 internal and exter- inputs, 6 switching relays, 1
9 x 8UP0 -R module (144) nal) audio input, 1 audio output
1 x 2TSM-R analog module (4)
(= 188)
Complete expansion focus on 1 x S2M -R module (32) (S2M external) 72 8 2 (internal 2 door terminal ports, 4 ringer
UP0 + S2M exchange line con- 1 x 8a/b-R module (8) 0 internal and exter- inputs, 6 switching relays, 1
nection 9 x 8UP0 -R module (144) nal) audio input, 1 audio output
1 x 2TSM-Ranalog module (4)
(= 188)
Complete expansion focus on 1 x S2M -R module (32) (S2M external) 40 8 64 (inter- 2 door terminal ports, 4 ringer
VoIP and UP0 + S2M exchange 1 x 8a/b-R module (8) 0 internal nal and inputs, 6 switching relays, 1
line connection 5 x 8UP0 -R module (80) external) audio input, 1 audio output
4 x 16VoIP-R module (64)
1 x 2TSM-R analog module (4)
(= 188)
a.All examples listed above exclusively refer to the systems COMmander 6000RX or COMmander 6000R with COMmander 6000R Xtension.
16 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Important Information
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 17
Important Information
Environmental Notice
For the sake of environmental protection, please If you want us to take over the disposal, please send the
make sure that packaging materials are also properly device to us.
disposed of.
Shipment which is not prepaid cannot be accepted.
Please consult your municipal administration authori-
ties for options of proper and environmentally safe
disposal of the device.
18 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Important Information
Abbreviations Used
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 19
Preparation (Modules)
Preparation (Modules)
This section provides overviews of the connections and setting options for the PBX modules. In addition, this section provides
information about the necessary hardware settings required on the modules before insertion.
Planning the system configuration in advance should prevent needing to make changes later.
Note: For the COMmander 6000R/RX, no connec- on the front panel. The socket assignments on the
tions are made directly to the module itself but rather front panel are described as of Page 34.
햲
햳
햷
햴 햹
햵
햹
햶
햹
햸
햹
햹
Fig. 1: S2M module 햷 Jumper for switching between the external and
햹
햲 Status display LEDs internal S2M ports (internal S2M port currently
not available)
햳 Terminal clamps (removable) for connecting
to the NTPM using terminal clamp panels 햸 A connector for attachment on the base circuit
board 햺
햴 Terminal clamps (removable) for connecting a
measurement device to the PMP (Protected 햹 S2M R Module: Status display LEDs
Monitor Point) 햺 S2M R Module: RJ-45 socket for connecting to
햵 RJ-45 socket for connecting to the NTPM the NTPM
햶 DIP switch for turning the NTPM operating 햻 S2M R Module: Terminal clamps (removable)
voltage on and off for connecting a measurement device to the
PMP (Protected Monitor Point)
20 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Preparation (Modules)
햺 햺 햺 햺 햸 햸 햸 햸
햹 햹 햲 햻 햽
햲 햻 햽
햶 햶 햳 햲 햻 햽
햵 햵
햴 햲 햻 햽
햶 햶
햻 햽
햵 햵
햷 햻 햽
햻 햽
햷 A connector for attachment on the base circuit
Fig. 3: S0 module
햻 햽
햲 S0 module: Terminal clamps (removable) for board
connecting to the S0 ports 1-4 (see circuit 햸 8S0 module: Terminal clamps (removable) for 햽
board label) connecting to the S0 ports 5-8 (see circuit 햽
햳 S0 module: RJ-45 socket for connecting to the board label)
S0 port 1 including LEDs for displaying the sta- 햹 8S0 module: Status display LEDs for
햽
tus of S0 ports 1 and 2 S0 ports 5-8 (see circuit board label) 햽
햴 S0 module: RJ-45 socket for connecting to the 햺 DIP switch for terminators on the S0 ports 5-8
햽
S0 port 3 including LEDs for displaying the sta- (see circuit board label)
tus of S0 ports 3 and 4 햻 4S0 R module: RJ-45 socket for connecting to 햽
햵 A connector for switching the operating mode the S0 ports 1-4 including LEDs for displaying 햽
on the S0 ports (see circuit board label) the status (see label)
햶 DIP switches for terminators on the S0 ports 1- 햽 8S0 R module: RJ-45 socket for connecting to
햽
4 (see circuit board label) the S0 ports 1-8 including LEDs for displaying
the status (see label)
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 21
Preparation (Modules)
S0 external S0 internal
Switching Terminators
Caution: Electrostatic charges can destroy sensitive Steps to Take
components.
1. Switch on: Push both buttons on the DIP switch to be
씮 Only a qualified electrician may open the casing switched to the “on” position. See Fig. 5.
and perform installation work within an open
casing. Switching off: Push both buttons on the DIP switch to
be switched to the “off” position. See Fig. 5.
씮 Divert electrostatic charges from yourself before
touching the circuit boards with your hands or any
tools. To do this, touch a metal object, preferably Fig. 5: Switch setting on the S0 module
earthed, e. g. the earthing terminal of the PBX or
a computer housing.
Requirements
– Previous system planning
Enabled Disabled
– The following is a list of uses for the port in question
(for enabling the terminators):
쐽
The PBX port in question is located at the
beginning/end of a series of devices, for example,
when laying an internal S0 bus in one direction.
쐽
The PBX port in question is only connected to one
device, for example, in a direct connection to an
NTBA with a PBX connection.
– The following is a list of uses for the port in question
(for disabling the terminators):
쐽
The PBX port in question is located in the middle
of a series of devices, for example, when laying an
internal S0 bus in two directions.
쐽
The PBX port in question is connected to an
existing socket, for example, to an NTBA with an
external S0 bus with terminators in the last socket.
22 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Preparation (Modules)
햲
햳 햳
햲
햴
햵
햳 햳
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 23
Preparation (Modules)
햵
햲
햳 햵
햳 햵
햵
햲
햵
햴 햵
햵
Fig. 7: 8UP0 module 햴 A connector for attachment on the base circuit
햵
햲 8UP0 module: Status display LEDs for board
UP0 ports 1-8 (see circuit board label) 햵 8UP0 R module: RJ-45 socket for connecting
햳 8UP0 module: Terminal clamps (removable) to the UP0 ports 1-8 including LEDs for dis-
for connecting to the UP0 ports 1-8 (see circuit playing the status (see label)
board label)
햵
햲 햵
햳 햵
햵
햵
햴 햵
햵
Fig. 8: 8a/b module 햴 A connector for attachment on the base circuit
햵
햲 8a/b module: Terminal clamps (removable) for board
connecting to the internal a/b ports 1-4 햵 8a/b R module: RJ-45 socket for connecting to
햳 8a/b module: Terminal clamps (removable) for the internal a/b ports 1-8 (see label)
connecting to the internal a/b ports 5-8
24 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Preparation (COMmander 6000)
Preparation (COMmander 6000)
This section describes the preparations required before installing and commissioning the device. In addition, information is
provided on how to open the casing and make changes, how to attach it to the wall, as well as how to install modules on the PBX
(not included in the delivery).
In addition, information is given on how to close the casing again after installation work has been completed.
The overview of the base circuit board provides information to facilitate finding the various connection options.
Requirements
– The unlocking tool included
Steps to Take
1. Push the unlocking tool into the opening on the upper
edge of the cover. See Fig. 9.
2. Pull the tool a little towards yourself. See Fig. 9.
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 25
Preparation (COMmander 6000)
햲 햳 햴 햵 햶
햷
햸
햹 햺 햻
햽 햾
햿
헀
헁
Fig. 10: COMmander 6000 base circuit board 햺 LAN Activity LED
햲 Module slot A for universal module use 햻 Connector for connecting the casing and the LED
햳 Module slot B for universal module use (Power LED)
햴 Module slot C for universal module use 햽 SW altern. button
햵 Module slot D for universal module use 햾 SW default button
햶 Module slot E for universal module use 햿 Reset button
햷 System dongle 헀 Status LED
햸 RJ-45 socket (Ethernet) for connecting to a PC Or 헁 USB Host for a Printer Connection
network 헂 SD card slot with memory card of the PBX
햹 LAN Link LED
26 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Preparation (COMmander 6000)
Requirements
– Previous system planning
– Upgrading: Module
Fig. 12: Remove the module
Note: Before inserting the module, first configure the
required settings on the module. See Chapter
Preparation (Modules) on page 20.
Steps to Take
1. Insert the module: Guide the module between the two
circuit board latches and press it vertically down-
wards to the base circuit board until it snaps in se-
curely. See Fig. 11.
Pull out the module: Push the circuit board latch on
the slanted side of the module a short distance away
from the module and then using the other hand,
simultaneously remove the module almost vertically
from the base circuit board. See Fig. 12.
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 27
Preparation (COMmander 6000)
LAN
Steps to Take
1. Use the thumb of one hand to loosen the light grey
3.
2.
latch in the lower part of the casing. See Fig. 13.
2. Use the other hand to pull the blue mounting rack di-
agonally upwards away from the light grey mounting-
frame. See Fig. 13.
28 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Preparation (COMmander 6000)
Steps to Take
Fig. 14: Open the cable channels
1. Pull the small plastic covers out of the opening on the
side out of which the cable should exit. See Fig. 14.
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 29
Preparation (COMmander 6000)
Requirements
Fig. 16: Reinstall the mounting rack
– Mounting frame fastened on the wall
1.
Steps to Take
Note: To prevent the cable in the USB casing socket
from becoming pinched, roll up the cable and place it
near the socket in the cable space.
1. Hold the mounting rack diagonally with the upper
edge towards the wall and install it at the top in the
mounting frame. See Fig. 16 on page 30.
2. In addition, press the lower part of the mounting rack
onto the mounting frame until the lock snaps in.
2.
30 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Preparation (COMmander 6000)
See
Requirements
– After installation, cables carefully reinserted into the Fig. 19: Closing the casing
cable space
Note: This mounting frame is equipped with fastening
hooks. See Fig. 18.
Steps to Take
1. Place the casing cover approx. 15 cm towards the top
by sliding it straight onto the casing. See Fig. 19.
2. Finally, pull the cover vertically downwards until it is in
the correct position.
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 31
Preparation (COMmander 6000R/RX)
Preparation (COMmander 6000R/RX)
This section describes the preparations required before installing and commissioning the device. In addition, information is pro-
vided on how to make changes and mount it in a rack as well as how to upgrade the PBX with modules (not included in the deliv-
ery).
Overviews of base circuit board as well as the connection areas on the front panel should facilitate finding the various connection
options.
햵
햶
햲 햲 햲 햲 햲 햳 햴 햴 햴 햴 햴 햴 햴 햴 햴 햴
햷
Fig. 20: Casing and front panel of the CPU 햸 RJ-45 socket (Ethernet) for connecting to a PC
COMmander 6000R/RX: or network with LAN-Link LED (below) and 햹
햲 Module slots A - E for universal module use LAN-Activity LED (above)
햳 Slot CPU 햹 USB Host for a Printer Connection
햺
햴 COMmander 6000R with Xtension/ 햺 Status LED
COMmander 6000RX: Module slots F- O for 햻 Power LED
햻
universal module use
햽 Power button to switch the 230 V system vol-
햵 Reset button tage 햽
햶 Software alternate button
햷 Software default button
32 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Preparation (COMmander 6000R/RX)
– Screwdriver
Requirements
.
Steps to Take
1. Insert one end of the patch cable into the RJ-45
socket (Ethernet) of the CPU front panel.
2. Insert the other end of the patch cable into one of the
RJ-45 sockets on the adjoining VoIP or VMF R mod-
ule.
3. For additional VoIP/VMF R modules: Insert one end
of the patch cable into the RJ-45 socket still available
on the first module.
4. Insert the other end of the patch cable in one of the
RJ-45 sockets on the second module.
5. Accordingly, repeat step 4 + 5 for each additional mo-
dule.
Note: The free RJ-45 socket on the last VoIP/VMF R
module is used for connecting to the network.
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 33
Preparation (COMmander 6000R/RX)
Fig. 21: S0 port assignment l Fig. 22: Assignment of the a/b port or UP0 port
햲 not in use 햲 not in use
햳 not in use 햳 not in use
햴 2a 햴 not in use
햵 1a 햵 a
햶 1b 햶 b
햷 2b 햷 not in use
햸 not in use 햸 not in use
햹 not in use 햹 not in use
34 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Preparation (COMmander 6000R/RX)
Requirements
– Hand tools and material:
쐽
Screwdriver
쐽
Screws
– The existing connections in the immediate vicinity of
the mounting location:
쐽
A freely accessible 230 V Schuko socket
쐽
NTBA/NTPM of the network provider; for great dis-
tances, hard wiring between the devices is neces-
sary
Warning: Liquid entering the casing can cause life-
threatening electric shocks or damage/destroy the
PBX.
씮 Only operate the device in closed, dry rooms.
Caution: Overheating can damage or destroy the
system.
씮 Note the ambient temperature values indicated in
the technical specifications.
씮 Make sure that heat produced by the device can
be adequately vented into the environment. Do
not install the system in a cabinet without ade-
quate air circulation.
씮 Make sure not to cover the fan on the rear side of
the casing.
Important: Mechanical loads and electro-magnetic
fields can impair PBX operation.
씮 Avoid mechanical loads (for example, vibrations).
씮 Avoid proximity to devices that generate electro-
magnetic fields or react sensitively to them (e. g.
radio receivers, private mobile radio devices,
amateur radio sets, mobile phones, DECT sys-
tems, or similar).
씮 Protect the device from soiling, excessive dust
and condensation.
Steps to Take
1. Push the casing into the rack.
2. Fasten the casing to the right and to the left with the
bracket and the four screws.
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 35
Connecting to the Network Provider
Connecting to the Network Provider
This section describes how to connect to the NTBA or to the NTPM of the network provider. If at all possible, it is determined
whether the device is to be connected directly or the lines are to be laid permanently. In addition, this section provides information
on how to connect the PBX to the Internet (VoIP) using a router. The diagram at the end gives an overview of how to set up the
connection for an ISDN connection and DSL (Fig. 25).
Warning: Touching voltage-carrying conductors or 씮 If available, also disconnect the devices from
telephone connections may cause a life-threatening auxiliary power sources (for example, UPS).
electric shock.
Important: Improper use may cause, for example,
씮 The PBX contains hazardous voltages, even out- functional restrictions or interference, the destruction
side of the power supply unit (for instance ringer of the device or, in a worst case scenario, personal
voltages). Work on active, contact-hazardous injury.
parts is only permitted after creating a voltage-
free state. 씮 Only connect equipment that is compatible with
Working close to active parts is only permitted if the proper use of the PBX.
these parts are voltage-free or are protected Note: For the COMmander 6000R/RX, no connec-
against direct contact. tions are made directly to the module itself but rather
씮 COMmander 6000: Pull out the power plug of the via the connector panel on the front panel. The socket
PBX before commissioning a qualified electrician assignments on the front panel are described as of
to open the casing to install the expansion module Page 34.
or perform switching or connecting services.
DSL router
Requirements Note: If the NTBA is relatively far away from the PBX,
a cable must first be laid.
– S0 module and connection cable (included in the
package) .
Steps to Take
– Enabled operation mode “S0 external” on the S0 port
in question. See Page 22. 1. Insert one end of the ISDN cable into the RJ-45
socket on the external S0 port.
– Enable the terminators at both ends of the connection
– in the NTBA and in the PBX on the external S0 port 2. Insert the other end of the ISDN cable into the RJ-45
in question. See Page 22. socket on the NTBA.
36 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Connecting to the Network Provider
Steps to Take
NT
1. Attach the wires to the four terminal clamps in the NT.
Connecting the Primary Rate Interface (NTPM) Directly to the S2M Port
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 37
Connecting to the Network Provider
Screen
Installing Cable Between S2M Port and Primary Multiplex Interface (NTPM)
Warning: Power surges, which can occur during Steps to Take
electrical storms, can cause life-threatening electric
shocks or damage/destroy the PBX.
1. Attach the wires to the four terminal clamps in the
NTPM.
씮 Let a qualified electrician lay all the cables inside
the building. Note: Refer to the NTPM terminal diagram in the doc-
umentation provided by the manufacturer.
Note: This type of connection is only available for the
COMmander 6000.The necessary terminal clamps 2. Connect the NTPM to the terminal clamps on the S2M
are not provided on the front panel of the ports. See Fig. 28.
COMmander 6000R/RX.
Requirements Fig. 28: Wire the NTPM and the S2M port.
– S2M module
– Enabled NTPM operating voltage on the S2M module
in as far as the NTPM is not powered by a separate
power plug. See Page 21.
Note: When using this operating voltage, the UB+
and UB- contacts on the S2M module must be con-
nected to the NTPM.
– Depending on the manufacturer and the local
conditions for one of the following NTPMs:
쐽
NTPM (NTBA with connection plate)
쐽
NTPMKU (NTBA with T-shaped mounting element
and copper connection)
쐽
NTPMKU (NTBA with T-shaped mounting element
and optic fibre connection)
– Distance/line length between devices - maximum of
NTPM Or
100 m
– Installation cable (for example, J Y (St) Y nx2x0.6)
with the following characteristics:
쐽
4-core or 6-core when using the NTPM operating
voltage on the S2M module
쐽
unscreened; however: screened for unfavourable
conditions, for example, near a strong transmitter
or an electrical power line
38 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Connecting to the Network Provider
Requirements
– Minimal distance between the devices
– Broadband Internet connection (for example, DSL
router, TV cable router)
– Existing network (LAN) with the following characteris-
tics:
쐽
Data transmission rate 100 Mbit/s
Note: For VoIP data communication in combination
with the transmission of limited amounts of data, a
data transmission rate in the LAN of 10 Mbit/s is suf-
ficient under certain circumstances. For VoIP data
communication in combination with the transmission
of large amounts of data (for example, downloads),
we recommend upgrading to a data transmission rate
of 100 Mbit/s. For this purpose, replace not only all of
the active network components (for example, the
switch and router) but also all of the passive network
components (for example, cables and wall sockets).
For reliable support of 100 Mbit/s, you need cables
and wall sockets of at least Category 5 (CAT5).
쐽
To use DiffServ to prioritize speech packets:
DiffServ support of all active network components
available and enabled
쐽
A router that is specifically designed for VoIP data
communication (“SIP aware”)
Note: If this is not the case, several of the ports on the
router necessary for VoIP data communication must
be enabled (RTP port and SIP-UDP ports) (“Port For-
warding”). A list of the ports used in the PBX can be
found in the configuration manager on the PBX under
Overview > Ports.
Important: Opening a port on the NAT-Router poses
a danger. Therefore additional measures for protec-
tion have to be taken.
– Patch cable
Steps to Take
1. Insert the end of the cable into the Ethernet socket on
the PBX.
2. Insert the other end of the cable into the output socket
on the router or into an existing network outlet.
Note: To connect the DSL router to the network
provider, please refer to the documentation provided
by the network provider included with the router. See
also Fig. 25 on page 36.
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 39
Connecting Analogue End Devices
Connecting Analogue End Devices
This section describes how to connect different analogue end devices to the a/b port of a COMmander 8a/b module. If at all
possible, it is determined whether the device is to be connected directly or the lines are to be laid permanently.
Warning: : Touching voltage-carrying conductors or 씮 If available, also disconnect the devices from
telephone connections may cause a life-threatening auxiliary power sources (for example, UPS).
electric shock.
Important: Improper use may cause, for example,
씮 The PBX contains hazardous voltages, even out- functional restrictions or interference, the destruction
side of the power supply unit (for instance ringer of the device or, in a worst case scenario, personal
voltages). Work on active, contact-hazardous injury.
parts is only permitted after creating a voltage-
free state. 씮 Only connect equipment that is compatible with
Working close to active parts is only permitted if the proper use of the PBX.
these parts are voltage-free or are protected Note: For the COMmander 6000R/RX, no connec-
against direct contact. tions are made directly to the module itself but rather
씮 COMmander 6000: Pull out the power plug of the via the connector panel on the front panel. The socket
PBX before commissioning a qualified electrician assignments on the front panel are described as of
to open the casing to install the expansion module Page 34.
or perform switching or connecting services.
Note: : If the end device is placed a considerable 2. Connect adapter to the RJ-45 socket that belongs to
distance away from the PBX, the cable and the wall the internal a/b port.
sockets must be permanently installed. See Page 40.
Installing Cables and Wall Sockets for the Internal a/b Port
Warning: Power surges, which can occur during Requirements
electrical storms, can cause life-threatening electric
– Installation cable (for example, J Y (St) Y 2x2x0.6)
shocks or damage/destroy the PBX.
with the following characteristics:
씮 Let a qualified electrician lay all the cables inside 쐽 One twisted pair per a/b port
the building.
쐽 Unscreened; however: screened for unfavourable
씮 Do not use the a/b ports to connect external
conditions, for example, near a strong transmitter
private branch exchanges.
or an electrical power line
Note: For a structured cable installation configured
– A TAE jack with the following characteristics:
on the COMmander 6000R/RX, CAT5 cables and
CAT5 wall sockets are used instead of the cables and 쐽
For telephones or combination fax/answering
wall sockets listed here. To connect an analogue machines, a single TAE jack with F-coding (a
device, a commercially-available RJ-45-TAE adapter socket labelled with an “F”)
is required. 쐽
For fax machines, modems and answering
machines, a TAE jack that also has a socket with
Important: For structured cable installation on a
N-coding.
COMmander 6000R/RX, the line length all of the
applicable end devices must be taken into account. Note: Outside of Germany, use RJ-45 sockets or the
analogue wall sockets normally used in the country in
question.
40 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Connecting Analogue End Devices
Steps to Take
1. Lay the line.
Note: Prevent interference. Avoid laying long
lengths of parallel lines, especially next to mains.
Twist the pairs.
2. Attach the wires to the two terminal clamps in the
internal a/b port. See Fig. 29 on page 41.
3. Connect the wall sockets to the terminal clamps in the
internal a/b port. See Fig. 29.
Further Steps
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 41
Connecting ISDN End Devices
Connecting ISDN End Devices
This section describes how to connect different ISDN end devices to the S0 or UP0 port of a COMmander 4/8S0 (R) or COMman-
der 8UP0 (R) module. If at all possible, it is determined whether the device is to be connected directly or the lines are to be laid
permanently.
Warning: Touching voltage-carrying conductors or 씮 If available, also disconnect the devices from
telephone connections may cause a life-threatening auxiliary power sources (for example, UPS).
electric shock.
Important: Improper use may cause, for example,
씮 The PBX contains hazardous voltages, even out- functional restrictions or interference, the destruction
side of the power supply unit (for instance ringer of the device or, in a worst case scenario, personal
voltages). Work on active, contact-hazardous injury.
parts is only permitted after creating a voltage-
free state. 씮 Only connect equipment that is compatible with
Working close to active parts is only permitted if the proper use of the PBX.
these parts are voltage-free or are protected Note: For the COMmander 6000R/RX, no connec-
against direct contact. tions are made directly to the module itself but rather
씮 COMmander 6000: Pull out the power plug of the via the connector panel on the front panel. The socket
PBX before commissioning a qualified electrician assignments on the front panel are described as of
to open the casing to install the expansion module Page 34.
or perform switching or connecting services.
Connecting Cable and Wall Sockets to the Internal S0 Port (Internal S0 Bus)
Warning: Power surges, which can occur during tions (RJ-45 jacks with integrated terminators) are
electrical storms, can cause life-threatening electric used.
shocks or damage/destroy the PBX.
Important: For structured cable installation on a
씮 Let a qualified electrician lay all the cables inside COMmander 6000R/RX, the line length all of the
the building. applicable end devices must be taken into account.
Note: For a structured cable installation configured
on the COMmander 6000R/RX, CAT5 cables and Requirements
CAT5-wall sockets are used instead of the cables
and wall sockets listed here. Instead of terminators – Enabled operation mode ”S0 internal” on the S0 port
installed in the wall sockets, pluggable bus connec- in question. See Page 22.
42 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Connecting ISDN End Devices
Internal S0 port
on the PBX
max. 1000 m
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 43
Connecting ISDN End Devices
Terminator
Further Steps Resistances
44 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Connecting ISDN End Devices
connected to the UP0 port, another UP0/S0 adapter is 2. Another end device or two COMfortel 1100/1500/
required. 1600/2500/2500 AB/2600 units: Connect the end
devices to the UP0/S0 adapter.
Steps to Take
1. Single COMfortel 1100/1500/1600/2500/2500 AB/ Further Steps
2600: Connect the system telephone to the RJ-45 쑱 To finish commissioning, you need to set up an
socket on the internal UP0 port. internal phone number for each end device in the
Another end device or two COMfortel 1100/1500/ configuration manager.
1600/2500/2500 AB/2600 units: Insert the UP0/S0
adapter into the RJ-45 socket on the internal UP0 port.
Installing Cable and the Wall Socket on the Internal UP0 Port
Warning: Power surges, which can occur during – One UP0/S0 adapter, depending on the device to be
electrical storms, can cause life-threatening electric connected
shocks or damage/destroy the PBX.
Note: To connect a single COMfortel 1100/1500/
씮 Let a qualified electrician lay all the cables inside 1600/2500/2500 AB/2600 system telephone, no UP0/
the building. S0 adapter is required. If two COMfortel 1100/1500/
Note: For a structured cable installation configured 1600/2500/2500 AB/2600 system telephones should
on the COMmander 6000R/RX, CAT5 cables and be connected to the UP0 port, another UP0/S0 adapter
CAT5 wall sockets are used instead of the cables and is required.
wall sockets listed here. Note: When using a UP0/S0 adapter, you do not need
Important: For structured cable installation on a to use an ISDN wall socket. The UP0/S0 adapter can
COMmander 6000R/RX, the line length all of the be mounted permanently on the wall and firmly
applicable end devices must be taken into account. connected with both screw terminals on the back of
the PBX. See Fig. 37 on page 46.
Requirements
Steps to Take
– Installation cable (for example, J Y (St) Y 2x2x0.6)
with the following characteristics: 1. Lay the line.
쐽 One twisted pair per UP0 port Note: Prevent interference. Avoid laying long lengths
쐽 unscreened; however: screened for unfavourable of parallel lines, especially next to mains. Twist the
conditions, for example, near a strong transmitter pairs.
or an electrical power line
2. Attach the wires to the two middle terminal clamps in
– An ISDN connection socket (for example, IAE or the internal UP0 port. See Fig. 39 on page 46.
UAE8) 3. With an ISDN wall socket: Connect the IAE or UAE8
Caution: Terminators integrated into the wall sockets socket to the terminal clamps on the internal UP0 port.
are destroyed and can therefore cause damage to the See Fig. 39, Fig. 36 and Fig. 38 on page 46.
device. Only UP0/S0 adapters: Connect both screw terminals
씮 Do not install terminators on one end of a line at the back of the UP0/S0 adapter to the terminal
connected to the UP0 port, as opposed to the S0 clamps on the internal UP0 port. See Fig. 37 on
port. Terminators are already integrated into the page 46.
end devices (COMfortel 1100/1500/1600/2500/ 4. With an ISDN wall socket: If necessary, connect the
2500 AB/2600 or UP0/S0 adapters). UP0/S0 adapter.
씮 Remove the terminators already integrated in the
wall sockets in order to use the sockets on the UP0
port. Further Steps
– Distance/line length between the devices depends on 쑱 Connect the end devices to the wall socket or to the
the cable used: connection sockets on the UP0/S0 adapter.
쐽 Maximum 600 m for a screened cable with a pair 쑱 To finish commissioning, you need to set up an inter-
diameter of 0.6 mm nal phone number for each end device in the config-
쐽 Maximum 1000 m for an unscreened cable with a uration manager.
pair diameter of 0.6 mm
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 45
Connecting ISDN End Devices
UAE8
IAE
46 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Connecting VoIP End Devices connecting
Connecting VoIP End Devices connecting
This section describes how to connect different VoIP end devices to the Ethernet port.
Warning: Touching voltage-carrying conductors or 씮 If available, also disconnect the devices from
telephone connections may cause a life-threatening auxiliary power sources (for example, UPS).
electric shock.
Important: Improper use may cause, for example,
씮 The PBX contains hazardous voltages, even out- functional restrictions or interference, the destruction
side of the power supply unit (for instance ringer of the device or, in a worst case scenario, personal
voltages). Work on active, contact-hazardous injury.
parts is only permitted after creating a voltage-
free state. 씮 Only connect equipment that is compatible with
Working close to active parts is only permitted if the proper use of the PBX.
these parts are voltage-free or are protected Note: For the COMmander 6000R/RX, no connec-
against direct contact. tions are made directly to the module itself but rather
씮 COMmander 6000: Pull out the power plug of the via the connector panel on the front panel. The socket
PBX before commissioning a qualified electrician assignments on the front panel are described as of
to open the casing to install the expansion module Page 34.
or perform switching or connecting services.
Steps to Take
1. Insert the end of the cable into the Ethernet socket on
the end device.
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 47
Connecting Other Devices
Connecting Other Devices
This section describes how to connect a printer to the COMmander 2TSM (R) module of the PBX for printing out call data.
Warning: Touching voltage-carrying conductors or 씮 If available, also disconnect the devices from aux-
telephone connections may cause a life-threatening iliary power sources (for example, UPS).
electric shock.
Important: Improper use may cause, for example,
씮 The PBX contains hazardous voltages, even out- functional restrictions or interference, the destruction
side of the power supply unit (for instance ringer of the device or, in a worst case scenario, personal
voltages). Work on active, contact-hazardous injury.
parts is only permitted after creating a voltage-
free state. 씮 Only connect equipment that is compatible with
Working close to active parts is only permitted if the proper use of the PBX.
these parts are voltage-free or are protected Note: For the COMmander 6000R/RX, no connec-
against direct contact. tions are made directly to the module itself but rather
씮 COMmander 6000: Pull out the power plug of the via the connector panel on the front panel. The socket
PBX before commissioning a qualified electrician assignments on the front panel are described as of
to open the casing to install the expansion module Page 34.
or perform switching or connecting services.
Requirements
– USB cable
– Printer compatible with PCL4 printer language (HP
Laserjet)
Note: You can use any printer with at least PCL4
emulation and USB port. PCL6 or PCL5c emulation is
downward compatible and includes PCL4.
– Minimal distance between the devices (up to 5 m)
Note: If the distance between the printer and the PBX
is greater than approx 2 m, the cable must be laid per-
manently.
Steps to Take
1. Insert one end of the cable into the USB socket on the
PBX (see Fig. 10 on page 26 or Fig. 20 on page 32).
2. Insert the other end of the cable into the USB socket
on the printer.
Further Steps
쑱 Hotel printing function: At the end of commissioning,
you need to enable the hotel function and set it up in
the configuration manager.
48 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Commissioning
Commissioning
This section describes how to place the PBX into operation. This includes turning on the PBX, setting up the network connection
between the computer and the PBX as well as logging into the web interface on the PBX for setting up the initial configuration.
After this, you will learn how to put each individual end device into operation.
Requirements
– Earthed PBX (see Page 30 and Page 34)
Steps to Take
1. Connect the PBX with a freely accessible 230 V
mains socket. For a COMmander 6000R/RX, additio-
nally turn the PBX on using the “Power” switch:
The “Status” LED and the “Power” LED light up in
red and orange for several seconds/minutes. Fig. 41: “Power” LED
Note: If the “Power” LED remains continuously lit in 쑱 Open the Configuration Manager of the PBX
red, an error has occurred. Please contact your (Page 49 or Page 50).
dealer or the manufacturer directly. 쑱 Configure the Basic Settings (Page 51).
The LEDs are easily visible on the front panel of the
COMmander 6000R/RX. 쑱 Perform system activation (Page 52).
If you press the Power button for 4 to 14 seconds
쑱 Put the End Devises into Operation (ab Page 54).
during the boot process, the PBX will be powered
down immediately. Note: Switching off/shutting down the PBX is descri-
bed in detail in the Operation and Configuration Ins-
tructions.
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 49
Commissioning
Steps to Take Note: The data will be encrypted even if you do not
transmit the safety certificate to your working environ-
1. Start a browser (for example, Mozilla Firefox). ment.
2. Enter the IP address of the PBX in the address field Since the safety exception rule was saved perma-
of the browser:
nently in the Mozilla Firefox, no more safety warnings
http://169.254.1.240
will be provided after accessing the PBX.
Important: In the case of some browsers, superflu-
After transmitting the safety certificate in the Internet
ous zeroes may cause problems. For this reason, you
Explorer you will still receive a safety warning.
should not enter e.g. 169.254.001.240 instead of
169.254.1.240. The configuration manager of the PBX will open
for entering the basic settings.
3. Press the enter key.
Since the PBX forces an HTTPS connection, Further Steps
your browser will provide a saftey warning (be-
cause of the missing safety certificate). 쑱 Configure the Basic Settings (Page 51).
50 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Commissioning
– Knowledge of the admin user password and admin The login dialog opens.
password of your PBX.
5. Enter the admin user password and admin password.
1. Start Internet Explorer 8.0. Note: After installing the safety certificate in the Inter-
net Explorer you will still receive a safety warning.
2. Enter the IP address of the PBX in the address field
of the browser.
– Knowledge of the admin user password and admin 7. Click on Confirm Security Exception.
password of your PBX.
The login dialog opens.
Steps to take 8. Enter the admin user password and admin password.
1. Start Mozilla Firefox 4.0. The configuration manager of the PBX will open.
2. Enter the IP address of the PBX in the address field Note: 쑱Since the safety exception rule was saved
of the browser. permanently in the Mozilla Firefox, for example, no
more safety warnings will be provided after accessing
3. Press the enter key. the PBX.
Your browser will provide a saftey warning.
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 51
Commissioning
System Activation
52 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Commissioning
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 53
Commissioning
Requirements
## 8 * 94 0 # Query the DHCP client status.
– An internal telephone with tone dialling and CLIP
## 8 * 94 1 # Query the IP address.
capability, in order to display CLIP information sent
from the PBX ## 8 * 94 2 # Query the subnet mask.
– Existing authorisation “Controlling the PBX via tele- ## 8 * 94 3 # Query the gateway address.
phone”
You will then hear the confirmation tone
Steps to Take (pulsating tone).
– Earthed PBX (see Page 30 and Page 34) The end device is ready for operation.
– Earthed PBX (see Page 30 and Page 34) 2. Select the language.
– Firmware version 4.4E oder higher for the telephone 3. Enter the internal phone number as an MSN for the
end device.
The end device is ready for operation.
54 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Commissioning
– Earthed PBX (see Page 30 and Page 34) 2. Enter the internal phone number as an MSN for the
end device.
The end device is ready for operation.
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 55
Configuration Manual
Configuration Manual
This section describes the procedure for the basic configuration of the COMmander 6000 series step by step using examples
(see also Opening Configuration Manager of the PBX via PC in the Same Network on page 50).
Example 1
NT with Point-to-Multipoint Connection NT with Point-to-Point Connection VoIP account with the VoIP provider sipgate
Telephone numbers provided by the net- PBX base number provided by the Exchange line access number (account
work provider (MSNs): 4712, 4713, 4714 network provider: 4711 with exten- number): 80
sion range (DDIs) 0-50 Data provided by the provider:
User name xxxyyy
Password yxz123
Internet telephone number 987654321
DSL router
connects the network
with the DSL connection
PC PC
Location Ethernet interface
Germany External S0 ports
Country prefix: 0049 on the COMmander 8S0 module
Cremlingen
Local prefix: 05306
System telephone
COMfortel VoIP 2500 AB
Internal: 36
Internal a/b ports External: 4712
on the COMmander 8a/b module External extension: 4711-36
System telephone
COMfortel 1100
Internal: 32
Analogue telephone External: 4712
COMfortel 500 External extension: 4711-32 System telephone
Internal: 21
COMfortel 2500
External: 4712 (delayed)
Internal: 30
External extension:
External: 4712 and 987654321
4711-21
External extension: 4711-0
56 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Configuration Manual
Hardware Configuration
Assign the existing modules to the corresponding expan- The Slot column lists each module slot (Slot A to
sion slots. E and, if necessary, Slot F to O).
Requirements 2. In the Usage list field, select the module that has
been inserted in the associated module slot. For
– Configuration manager, opened with sufficient au- available module slots, select not defined.
thorization
Note: Note that parameters set here correspond to
Steps to take the real hardware settings on your PBX. If this is the
case, the settings are marked in black. If this is not the
1. Open the page Hardware > Selection of modules. case, the settings are marked in red.
IP Configuration
Configure the IP configuration for the PBX (CPU), the VMF/VoIP Module
VoIP (R) and the VMF (R) module.
Requirements
Important Contact the responsible system adminis-
trator and configure the settings according to his – Configuration manager, opened with sufficient au-
instructions. thorization
Steps to take
1. Open the page Administration > IP configuration.
2. If you would like to allocate a permanent IP address
CPU to the module, clear the check box for the module
(e. g. 8VoIP module - Slot E).
Requirements
3. Under IP address enter the desired IP address for
– Configuration manager, opened with sufficient au- the corresponding module.
thorization
4. If necessary, change the entered subnet mask for the
Steps to take corresponding module under Subnet mask.
1. Open the page Administration > IP configuration. 5. If necessary, change the entered gateway for the cor-
2. Under Ethernet configuration of the CPU, change responding module under Gateway.
the settings made during commissioning for the con-
nection to a PC or to the network, if necessary. Further steps
쑱 Save your settings before you leave the page.
Further steps
쑱 Save your settings before you leave the page.
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 57
Configuration Manual
Port Configuration
Port configuration is the basic set-up for the inserted mod- Internal UP0 ports
ules as well as for the CPU. The connection assignments Configure the internal UP0 port on the COMmander 8UP0
for the ports must be set depending on the proper use and (R) module.
adapted to the actual connection options on site.
Note: For a COMmander 8a/b (R) module, COM- Requirements
mander 8VoIP (R) module, COMmander 16VoIP (R) – Configuration manager, opened with sufficient
module or COMmander VMF (R) module, no port authorization
configuration is necessary.
– Inserted COMmander 8UP0 (R) module
Steps to take
1. Open the page Hardware > Portkonfiguration.
Internal and external S0 ports 2. Under Usage, configure the UP0 ports for the corre-
Configure the internal and external S0 ports on the COM- sponding module (e. g. 8UP0 module - Slot E) as an
mander 4S0/8S0 or COMmander 4S0/8S0 R module. internal port as you wish. (Unused ports are set to
available.)
NoteNote that parameters set here correspond to the
actual port configuration on your PBX (which port is NoteFor UP0 ports, the kind of connection is automat-
set to internal or external). If this is the case, the set- ically configured as PTMP connection.
tings are marked in black. If this is not the case, the
Further steps
settings are marked in red.
쑱 Save your settings before you leave the page.
The port configuration on the COMmander 4S0 (R)
module is the same as the configuration described
here.
Requirements
– Configuration manager, opened with sufficient VoIP channels
authorization
Requirements
– Inserted COMmander 4S0/8S0 (R) module
– Configuration manager, opened with sufficient
Steps to take authorization
1. Open the page Hardware > Port configuration. Steps to take
2. Under Usage, configure the S0 ports for the corre- 1. Open the page Administration > VoIP configura-
sponding module (e. g. 8S0 module - Slot E) as an tion.
internal or external port as you wish. (Unused ports
are set to available.) 2. In the External VoIP channels list field under Distri-
bution of the VoIP channels, select the desired
3. On the external S0 ports under Kind of connection, number. Take into account the capacity of your Inter-
configure the connection type of the NTs you have re- net connection.
quested from your network provider. (When using in- Note: The PBX has two VoIP channels by default.
ternal ports, the connection type is automatically set When using a VoIP module, the two VoIP channels
to a PTMP connection.) included by default are switched off! The number of
4. On the external S0 ports under Additional functions, VoIP channels available when using VoIP modules
activate, if necessary, S0 bus monitoring in order to consists of the number of channels on the VoIP mod-
prevent waiting times on the external dial tone (rec- ules together with the additional channels enabled on
ommended). the PBX dongle via the Upgrade Center.
Further steps
쑱 Save your settings before you leave the page.
58 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Configuration Manual
- Internal telephone numbers for automatic reception 6. a/b, S0, UP0 ports: In the Port list field, select the port
- Internal basis telephone numbers for open callbacks connected to the end device.
- Internal telephone numbers for door terminals 7. In the Device type list field, select a suitable type for
- Internal telephone numbers for audio outputs your end device.
- Short-code numbers
- Emergency numbers 8. Click Saving.
Double assigning a number is not possible! For the subscriber a user PIN (PIN) and a user
On the page Overviews > Telephone numbering password (Password) are generated automati-
plan, you can get an overview of the internal tele- cally.
phone numbers already assigned at any time. 9. Repeat step 2 to 8 for all additional telephone num-
The telephone numbers can consist of two to four dig- bers.
its. Using telephone numbers with few digits (two or Note: The usage of VoIP telephones on the PBX is
three-digit numbers) inevitably restricts the possible only possible after a successful login. For logging in
supply of telephone numbers with more digits. For the PBX, the configured user password and the user
example, if the telephone number 12 is assigned, the name are used for authentication. As user name, the
telephone numbers 120-129 and 1200-1299 are no internal telephone number (Telephone number) is
longer available. used.
For some functions, only telephone numbers with a You can change the user PINs and passwords config-
maximum of 3-digits can be assigned because the ured automatically:
last digit is need for the function (e. g., door terminal Contrary to passwords, all PINs in the PBX are
numbers, telephone numbers for open callbacks). unique. I. e., it is not possible to configure the same
PIN twice.
쐽 PIN: Exactly 6 digits
Digits
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 59
Configuration Manual
쑱 ISDN device or system telephone: Enter the internal 4. In the Name entry field, enter a suitable name with a
telephone number as (first) MSN. maximum of 16 characters.
60 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Configuration Manual
Further steps
쑱 Save your settings before you leave the page.
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 61
Configuration Manual
ISDN Point-to-Multipoint Connection 6. In the Name entry field, enter a suitable name with a
maximum of 16 characters.
In the PBX, configure each existing ISDN Point-to-
Multipoint connection with the telephone numbers pro- 7. In the Ringer rhythm list field, select the desired
vided by the network provider. ringer rhythm for external calls via this telephone
number.
Requirements
8. Click Saving.
– Configuration manager, opened with sufficient
authorization 9. Repeat step 4 to 8 for all additional MSNs.
– External S0 port in connection type Point-to-Multipoint Note: A change under GSM and LCR is only neces-
connection (see Hardware Configuration on page 57 sary in exceptional cases (for example, when operat-
and Internal and external S0 ports on page 58). ing a GSM gateway).
Under Charge information, a change is only neces-
Steps to take sary if problems are caused by call charges.
1. Open the page Public switched tel. networks > Under CLIP no screening and Telephone numbers
ISDN connections > PTMP connection. for CLIP no screening a change is only necessary if
2. In the list field at the top under PTMP connection, se- you would like to transfer special telephone numbers.
lect the external S0 port.
3. In the Name of the PTMP connection entry field, en-
ter a name with a maximum of 16 characters.
4. Click New. ISDN Point-to-Point Connection
5. In the from entry field under Multiple subscriber In the PBX, configure each existing ISDN Point-to-Point
number (MSN), enter your first available MSN. connection with the telephone numbers provided by the
network provider.
5. In the from entry field under DDI number block Further steps
(DDIs), enter the extension range with the lowest
쑱 Save your settings before you leave the page.
DDI.
Note: Make sure to follow the instructions provided 쑱 Click Configure, to configure further settings for the
by your network provider for entering the DDI number ISDN PTP connection.
block exactly. If you want to enter a one or two-digit 씮 A change under GSM and LCR is only necessary
DDI range, your network provider must provide you in exceptional cases (for example, when operat-
with one and two-digit DDIs. The same applies to a ing a GSM gateway).
two and three-digit DDI range. 씮 By enabling CCBS and/or CCNR a callback on
You can also enter the zero with the exact number of busy (CCBS) or on no reply (CCNR) can be
digits of the DDIs (e.g. DDI number block 00-99). offered to external callers if the service feature
Next, you need to assign an internal call destination has been released by the network operator.
to each of these multi-digit DDIs (e.g. 00 and 01) in 씮 You can disable the transfer of Charge informa-
the call distribution. Then the PBX will only react tion if it causes problems on an external connec-
when the number of digits has been reached, i.e. tion.
when the caller has dialled 00 or 01, for example, as
62 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Configuration Manual
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 63
Configuration Manual
PTP connection: For VoIP accounts with a DDI VoIP Point-to-Point Connection
number block based on the SIP-DDI feature (also
known as SIP trunking). Requirements
PTMP connection: For VoIP accounts with one or – Configuration manager, opened with sufficient
more VoIP telephone numbers. authorization
6. Click Saving. – Created VoIP account with kind of connection PTP
7. Repeat step 2 to 6 for all additional accounts. connection (see VoIP accounts on page 63)
VoIP Point-to-Multipoint Connection 3. In the PBX base number entry field, enter the PBX
base number (without extension).
Requirements 4. In the from: entry field under DDI number block
– Configuration manager, opened with sufficient (DDIs), enter the extension range with the lowest
authorization DDI.
– Created VoIP account with kind of connection PTMP Note: Make sure to follow the instructions provided
connection (see VoIP accounts on page 63) by your provider for entering the DDI number block
exactly. If you want to enter a one or two-digit DDI
Steps to take range, your provider must provide you with one and
two-digit DDIs. The same applies to a two and three-
1. In the Exchange line access number (account
digit DDI range.
number) entry field, enter an internal telephone
number from the telephone numbering plan (see In- 5. In the until: entry field under DDI number block
ternal Telephone Numbers on page 59). (DDIs), enter the extension range with the highest
DDI.
2. In the User name, Password and, if necessary, Au-
thorization ID entry fields, enter the access data pro- Note: For linear call distribution (Public switched
vided for login. tel. networks > Call distribution > Linear call dis-
3. Click New. tribution) you only have to enter differing DDIs for the
connection. I. e., for similar internal telephone num-
4. In the Multiple subscriber number (MSN) entry bers and external extension numbers, in linear call
field, enter your first available MSN. distribution a 1:1-assignment is made automatically
for the DDIs from the DDI number block (DDIs).
5. In the Display name entry field, enter a name with a
maximum of 16 characters. For linear call distribution you can configure the ringer
rhythm under Ringer rhythm for above mentioned
6. In the Ringer rhythm list field, select the desired
PTP connection.
ringer rhythm for external calls via this telephone
number. 6. Click Saving.
7. Click Saving. 7. Click Back.
8. Repeat step 3 to 7 for all additional MSNs.
9. Click Back.
Note: When using the provider T-Online, the Internet
phone numbers received from the provider must be
entered under User name, Multiple subscriber
number (MSNs) and Display name.
64 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Configuration Manual
Call Distribution
Call distribution is required to establish a connection 3. In the second list field Call distribution for, select
between the external telephone numbers already config- one of the following options:
ured and the internal subscribers.
VoIP or ISDN point-to-point connection:
When using a Point-to-Multipoint connection (ISDN and PBX base number [DDI number block]|Name
VoIP), the internal telephone numbers are individually
assigned to the MSNs. Under DDI the entered DDIs are listed.
On a Point-to-Point connection (ISDN and VoIP), the con- ISDN point-to-multipoint connection: Slot ... - Port
figuration of a linear call distribution is usual (e. g., a call ...|Name
to 4711-21 is distributed to the internal subscriber tele-
Under MSN the entered MSNs are listed.
phone number 21). This includes having assigned internal
telephone numbers that lie in the extension number range VoIP point-to-multipoint connection: Account
(DDIs) assigned by the network provider. Call distribution name
can then occur automatically.
Under MSN the entered MSNs are listed.
Organisational, system-dependent or company internal
guidelines can require diverging from linear telephone 4. Point-to-point connection: Select or clear the Linear
number assignments in particular situations. To do this, call distribution (external = internal) check box.
the PBX gives you the option of configuring divergent call
5. Point-to-point connection with linear call distribution:
distribution. This configuration is done in two steps. In the
first step, the PBX is notified which telephone numbers If necessary, click New.
are to be taken out of the linear call distribution. In the sec- In the DDI entry field, enter a DDI differing from the
ond step, the telephone numbers are directly assigned linear call distribution.
internal subscribers. Click Saving.
If multiple internal devices should be accessible over an Note: DDIs that differ from the linear call distribution
external telephone number, an internal group, to which must be in the entered DDI number block.
the subscribers in question are assigned, is selected as
the destination for the call distribution. 6. In the Internal tel. no. | Name list fields, select an in-
ternal telephone number for each external telephone
number (MSN or DDI).
7. Click Saving.
8. Repeat step 2 to 7 for all additional external connec-
Configuring call distribution tions.
In the PBX, configure the call distribution for each entered
external telephone number.
In the PBX, configure the linear call distribution for the
entered DDI number range as well as the differing call dis-
tribution.
Requirements
– Configuration manager, opened with sufficient
authorization
– Configured subscribers/groups (see Internal sub-
scribers on page 59 or Internal groups on page 60)
– Configured external connections (see External Tele-
phone Numbers on page 61)
Steps to take
1. Open the page Public switched tel. networks > Call
distribution.
2. In the first list field Call distribution for, select one of
the following options:
ISDN point-to-point connections
ISDN point-to-multipoint connections
VoIP point-to-point connections
VoIP point-to-multipoint connections
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 65
Configuration Manual
Steps to take
• Open one of the following pages:
Subscribers: Overviews > Telephone numbering
plan
Groups: Overviews > Groups
Call distribution: Overviews > Call distribution
Note: You can use the printing function in your
browser to print out this overview.
It is advisable to print the page in landscape format.
66 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Configuration Manual
씮 ... check whether the internal telephone number If none of the telephones that are accessible over an
called has been assigned to the telephone in external connection (NT) ring, ...
question (see Overviews on page 66).
씮 ... disconnect the NT for approx. 5 seconds from
씮 ... check whether the telephone bell is switched off the 230-V- power supply (pull the power plug) and
(see the manual for the telephone). the exchange line connection (pull the TAE con-
씮 ... check the registration status and, if necessary, nector). If you can now make outbound calls
the access data on VoIP telephones. again, this means that the NT was disrupted. If the
malfunction remains, notify your line fault service.
If the connection is immediately disconnected after
picking up the VoIP telephone being called or no call-
ing is possible, ...
씮 ... check the codec configured in the telephone
and change it, if possible. The PBX supports the
following codecs: G.711 and iLBC.
If no incoming call on a VoIP telephone is possible,
although it has been registered, ...
씮 ... check the codec configured in the telephone
and change it, if possible. The PBX supports the
following codecs: G.711 and iLBC.
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 67
Configuration Manual
Example 2
Configuration 1 Configuration 2 Configuration 3
Name: Business hours Name: Night-weekend Name: Holiday
Identification number: 201 Identification number: 202 Identification number: 203
Call distribution: as in Call distribution: as configuration 1 Call distribution: as configuration 1
Example 1 on page 56 except 4711-0 and 4712 except 4711-0 and 4712
to 20 (analogue answering machine) to 20 (analogue answering machine)
8:00 18:00
Monday
8:00 18:00
Tuesday
8:00 18:00
Wednesday
8:00 18:00
Thursday
8:00 18:00
Friday
Saturday
Sunday
0:00
Holiday
68 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Configuration Manual
5. Repeat step 2 to 4 for all additional configurations. he configuration that was last valid on the previous
day is always transmitted to the next day. Therefore,
6. If necessary, change the name config-1 under Con- it is not necessary to activate a configuration at mid-
figuration name (up to 16 characters). night if the configuration had already been activated
on the previous day or also on other days in the past.
7. In order to change the automatically assigned identi-
fication numbers, double-click in the corresponding Important: An activated holiday is taken into account
line under Identification number and enter a 2 to 4- from 12 p.m. of the one day until 12 p.m. on the fol-
digit identification number. lowing day.
On an activated holiday, the switching times for the
Further steps corresponding weekday are taken into account if no
holiday switching times have been entered (holiday).
쑱 Save your settings before you leave the page.
If the normal sequence is interrupted by special
쑱 Configure the configuration-dependent settings for switching times/configurations on a holiday, the con-
the created configurations (see Configuring Configu- figuration of the day before is valid at the beginning of
ration-dependent settings on page 70). the holiday as long as it is switched over (automati-
cally or manually). If, for example, another holiday fol-
쑱 If necessary, copy a configured configuration to trans- lows a holiday, the last valid configuration of the holi-
mit the configuration-dependent settings for new con- day before remains switched on as long as the
figurations (Copy). configuration is switched over the second holiday.
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 69
Configuration Manual
If the holiday end at 12 p.m. the usual configuration Switching automatic configuration
for the weekday is switched on (even if a configura-
tion was manually switched on during the holiday).
switchover on/off
Configuring the holidays is done in the calendar of the
Requirements
PBX on the page Functions > Calendar.
In addition to or instead of public holidays, you can – Configuration manager, opened with sufficient au-
also use the calendar to enter company holidays. thorization
– At least two configured configurations
– Configured switching times
– Current PBX time
Copying switching times
Copy the switching times for the first weekday set to the
weekdays with the same switching times. Steps to take
1. Open the page Time control > Configurations.
Requirements
2. Select or clear the Automatic configuration switch-
– Configuration manager, opened with sufficient over check box.
authorization
– Switching times configured for a weekday
70 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Configuration Manual
Further steps
쑱 Save your settings before you leave the page.
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 71
Index
Index
A Ethernet interface
Abbreviations Used ................................................................. 19 Network provider, connecting to .......................................... 39
Alarm input .............................................................................. 10 Ethernet port ............................................................................. 8
PC, connecting .................................................................... 53
Analogue port, internal .............................................................. 9
Cable, installing ................................................................... 40 Ethernet port, connecting PC .................................................. 53
End devices, connecting ..................................................... 40 Extension limits ....................................................................... 15
Audio output ............................................................................ 10 Extensions ............................................................................... 10
Extensions, maximum ............................................................. 11
B External S0 port
Base circuit board (COMmander 6000) .................................. 26 Cable, installing ................................................................... 37
Basic configuration .................................................................. 56 Network provider, connecting to .......................................... 36
Call distribution .................................................................... 65 External S2M port
Call distribution, overview ................................................... 66 Network provider, connecting to .......................................... 37
External telephone numbers ............................................... 61
Group members, assign ...................................................... 61 G
Groups with delayed ringer ................................................. 61 Guarantee ....................... see leaflet „Conditions of Guarantee,
Groups, create .................................................................... 60 Information Service“
Groups, overview ................................................................ 66
Hardware configuration ....................................................... 57 I
Internal telephone numbers ................................................ 59
Installation
IP configuration ................................................................... 57
General ............................................................................... 12
ISDN connection ................................................................. 62
Location ............................................................................... 61 Internal S0 port
Port configuration ................................................................ 58 Cable, installing ................................................................... 42
Subscribers, create ............................................................. 59 End devices, connecting ..................................................... 42
Subscribers, overview ......................................................... 66 Internal UP0 port
Test ..................................................................................... 66 Cable, installing ................................................................... 45
Time-dependent .................................................................. 69 End devices, connecting ..................................................... 44
Voice over IP (VoIP) ............................................................ 63 ISDN end devices, putting into operation ................................ 55
Basic configuration, time-dependent ....................................... 68
Configuration-dependent settings ....................................... 70 M
Profile assignment, groups .................................................. 71 Manual, configuration .............................................................. 56
Profile assignment, subscribers .......................................... 71 Memory Card (VMF (R) module)
changing .............................................................................. 23
C Minimum requirements PC ...................................................... 18
Cable channels, opening in mounting frame ........................... 29
Mounting frame, disconnecting from mounting rack ............... 28
Casing
Mounting frame, mounting on wall .......................................... 29
Mounting on the wall ........................................................... 28
Mounting rack, installing .......................................................... 30
Casing, closing
COMmander 6000 ............................................................... 31 Music input .............................................................................. 10
Casing, mounting in rack ......................................................... 35
N
Casing, opening Network provider, connecting to .............................................. 36
COMmander 6000 ............................................................... 25
Notice symbols .......................................................................... 6
CE symbol ....................... see leaflet „Conditions of Guarantee,
NTPM operating voltage, setting ............................................. 21
Information Service“
COMmander 4S0(R) module ................................................... 21 O
COMmander 8S0(R) module ................................................... 21 On/Off switch (COMmander 6000R/RX) ................................. 49
COMmander S2M (R) module ................................................. 20 Operation
COMmander VoIP/VMF modules, connecting ........................ 27 using standard telephones .. see Short Operation Instructions
COMmander 6000R/RX ...................................................... 33 (Auerswald Mega Disk and www.auerswald.de)
Commissioning ........................................................................ 49 Operation ............ see Operation and Configuration Instructions
Configuration ....... see Operation and Configuration Instructions (Auerswald Mega Disk and www.auerswald.de)
(Auerswald Mega Disk and www.auerswald.de) Overview
Configuration manual .............................................................. 56 Base circuit board (COMmander 6000) ............................... 26
Copyright ................................................................................. 18 COMmander 16VoIP (R) module ........................................ 23
COMmander 4S0(R) module ............................................... 21
D COMmander 6000R/RX ...................................................... 32
COMmander 8a/b (R) module ............................................. 24
Declaration of conformity ................... see leaflet „Conditions of
COMmander 8S0(R) module ............................................... 21
Guarantee, Information Service“
COMmander 8U P0 (R) module ........................................... 24
E COMmander 8VoIP (R) module .......................................... 23
COMmander S2M (R) module .............................................. 20
Earthing
COMmander VMF (R) module ............................................ 23
COMmander 6000 ............................................................... 30
COMmander 6000R/RX ...................................................... 34 P
End devices, power consumption ........................................... 17 PBX
Environmental Notice .............................................................. 18 Basic configuration .............................................................. 56
Ethernet configuration ............................................................. 53 Basic configuration, time-dependent ................................... 68
72 COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12
Index
Q
Quick setup ............................................................................. 50
R
Ringer input ............................................................................. 10
Ringer output, second ............................................................. 10
RJ-45 socket assignment
on the COMmander 4S0 R, 8S0 R, 8UP0 R or
8a/b R module ..................................................................... 34
on the COMmander S2M R module .................................... 34
S
S0 port, external ........................................................................ 8
Cable, installing ................................................................... 37
Network provider, connecting to .......................................... 36
S0 port, internal ......................................................................... 9
Cable, installing ................................................................... 42
End devices, connecting ..................................................... 42
S2M port, external ...................................................................... 8
Network provider, connecting to .......................................... 37
Safety certificate ................................................................ 50, 51
Safety information ..................................................................... 6
Serial port
Printer, connecting .............................................................. 48
Service ......... see leaflet „Conditions of Guarantee, Information
Service“
Static IP address, configuring ................................................. 53
Subscribers, release (system activation) ................................ 52
Switchable ports, operating mode ........................................... 22
Switching relay ........................................................................ 10
System activation .................................................................... 52
System configuration, planning ............................................... 20
System telephones
Putting into operation .......................................................... 55
T
Technical data ......................................................................... 12
Telephone numbers, enter
External numbers ................................................................ 61
Internal numbers ................................................................. 59
Terminators ............................................................................. 22
Time control (basic configuration) ........................................... 69
U
UP0 port ..................................................................................... 9
Cable, installing ................................................................... 45
End devices, connecting ..................................................... 44
UP0 port, internal ....................................................................... 9
Upgrade Center
system activation ................................................................. 52
COMmander 6000/R/RX - Firmware Version 5.6 - Installation and Commissioning Instructions 05 12/12 73
884316 05 12/12
For the sake of the environment – 100% recycled paper