TABLE OF CONTENTS REPUBLIC OF THE PHILIPPINES

Department of Public Works & Highways


SURVEY PLAN
ARCHITECTURAL OFFICE OF THE BUILDING OFFICIAL
A-001 PERSPECTIVE, VICINITY MAP,
SITE DEVELOPMENT PLAN,
RECOMMENDING APPROVAL
DRAWING INDEX
A-002 GENERAL NOTES &
SPECIFICATIONS
A-101 LEVEL 1 & 2 FLOOR PLAN
A-102 LEVEL 3 & ROOF PLAN
APPROVED
A-111 REFLECTED CEILING PLAN
A-201 EAST BUILDING ELEVATION
NORTH BUILDING ELEVATION
A-202 SOUTH BUILDING ELEVATION
WEST BUILDING ELEVATION
A-301 BUILDING SECTION THRU AA
A-302 BUILDING SECTION THRU BB
A-401 WINDOW & DOOR SCHEDULE

STRUCTURAL
S-101 GENERAL NOTES, SPECIFICATIONS
MISCELLANEOUS DETAILS
S-102 FOUNDATION PLAN, 2L FRAMING LAND USE AND ZONING
FOOTING & COLUMN DETAIL
S-103 3F FRAMING PLAN, ROOF FRAMING
BEAM & SLAB DETAILS
S-104 STRUCTURAL SECTION

PLUMBING
P-101 PLUMBING GENERAL NOTES,
MATERIAL SPECIFICATIONS, LINE AND GRADE
LEGENDS SYMBOLS &
ABBREVIATIONS, DETAILS
3 N27d 41'E ; 12.00m 4
P-102 GROUND FLR PLUMBING LAYOUT,
ISOMETRIC VIEW
P-103 SECOND, THIRD & ROOF
PLUMBING LAYOUT

ELECTRICAL
E-101 GENERAL NOTES, POWER ARCHITECTURAL
EXISTING HOUSE
TO REMAIN
SINGLE LINE DIAGRAM, LOAD
(NOT PART OF THIS SCHEDULE, SPECIFICATIONS
BUILDING PERMIT E-102 LIGHTING PLAN- LEVELS 1, 2 & 3
APPLICATION)
E-103 POWER PLAN - LEVELS 1, 2 & 3

N62d54'W ; 22.60m

S62d31'E ; 21.32m
1 2 3

3000 6000 ±3002


PROJECT DIRECTORY STRUCTURAL
ARCHITECTURAL:
C
ARCH. JUAN ALEXANDER BARREDO
L14a, Blk2 Crystaldale Subdivision, Baguio City
PORTION OF PORTION OF CP (0947) 913-2412
LOT 7, BLK 2 LOT 9, BLK 2
email: bibjas@yahoo.com
LEVEL 1 OF

6075
STRUCTURAL:
SITE 2000
SIDE
PROPOSED
EXTENSION
2 CAR GARAGE
2000 ENGR. MARK DE GUZMAN
SETBACK
SIDE Bakakeng North, Baguio City SANITARY/ PLUMBING
SETBACK CP (927) 417-6190
300 B
email: mark_deg73@yahoo.com
450

600
400
400

A PLUMBING/ SANITARY:

FRONT SE
ENGR. PEDRO JR E. AQUINO
FRONT SE

4000
DPS Compound, Baguio City
DRIVEWAY

±3145
4000

CP (916) 735-1410

TBACK
email: pedzaquino@gmail.com
TBACK

1
M
PROPERTY
LINE
ELECTRICAL: ELECTRICAL
12.00m SIDEWALK
2 S21d16'W ; WAY ENGR. CESAR TAMESIS
NEW DRIVE
SIDEWALK 86 M. Roxas St. Tabora Barangay, Baguio CIty
ASH STREET UE Tel: (074) 300-3239; CP: (0917)422-1819
BLACK TR RTH email: cesar.tamesis@yahoo.com
NO

VICINITY MAP SITE PLAN


SOIL ANALYSIS:
PLAN BIP STEADFAST GROUND INC.
2 1 NORTH No. 1 Purok 7, Bakakeng North, Baguio City
(74) 442-4190 ; (74) 444-4830
NTS 1:150m
FIRE DEPARTMENT

JA
CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.
PERSPECTIVE, VICINITY MAP, SITE PLAN
PROPOSED HOUSE EXTENSION (3-LEVEL) TABLE OF CONTENTS, PROJECT DIRECTORY
JUSTINE & JOYCE D. CALDERON A-001
SB
JUAN ALEXANDER S. BARREDO Architect, Leed AP Lot 8, Block 2, Black Ash Street, Richview Subdivision,
PRC NO. 16394 VALIDITY: November 18, 2018 Bakakeng, Baguio City, Philippines 31 Unit G. Agno Street, Quezon City, Metro Manila
PTR NO. 3596747 DATE: March 16, 2018
PLACE: Baguio City TIN: 471-545-699
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR BLDG PERMIT APPLICATION
GENERAL NOTES TOPSOIL STOCKPILES
STOCKPILE SITE TOPSOIL REQUIRED FOR RE-USE AND IMPORTED WOOD MATERIAL
COAT WHERE DAY WORK ADJOINS THE OTHER.

1. THE CONTRACTOR/ BUILDER SHALL CHECK AND VERIFY ALL TOPSOIL. PROTECT STOCKPILES FROM CONTAMINATION BY OTHER LUMBER SHALL BE OF THE RESPECTIVE KINDS FOR THE VARIOUS CEMENT PLASTER CURING:
DIMENSIONS, NOTES AND CONDITIONS ON SITE BEFORE ANY EXCAVATED MATERIAL, WEEDS AND BUILDING DEBRIS. PARTS OF THE WORKS, WELL SEASONED, FREE FROM LARGE DO NOT ALLOW RAPID OR UNEVEN DRYING OUT. KEEP
CONSTRUCTION WORK IS STARTED. ALL DISCREPANCIES SHALL LOOSE UNSOUND KNOTS, SAP, CRACKS, SHAKES OR OTHER CONTINUOUSLY MOIST FOR 2 DAYS AND ALLOW TO DRY FOR 5
BE REPORTED TO THE ARCHITECT. NO WORK OR ORDERING OF DISPOSAL OF SURPLUS MATERIAL IMPERFECTIONS IMPAIRING ITS STRENGTH, DURABILITY AND OR DAYS BEFORE APPLYING FURTHER PLASTER COATS.
MATERIAL MAY BE STARTED UNTIL ALL DIMENSIONED ITEMS HAVE TAKE POSSESSION OF SURPLUS MATERIAL AND REMOVE IT FROM APPEARANCE. SOME WOODEN STRUCTURAL AND FRAMING
BEEN RESOLVED. NO EXTRA CHARGE OF COMPENSATION WILL BE THE SITE. REMOVE CLEARED AND GRUBBED AND GROUND LUMBER MAYBE ROUGH IN DIMENSIONS THAT ARE SHOWN ON THE V-JOINTS
ALLOWED ON ACCOUNT OF ANY DIFFERENCE BETWEEN ACTUAL MATERIAL FROM THE SITE. DISPOSE OF THIS MATERIAL LEGALLY. DRAWINGS. ALL EXPOSED WOODWORKS SHALL BE SMOOTHLY PROVIDE V-JOINTS CUT STRAIGHT THROUGH THE PLASTER TO THE
DIMENSIONS AND THE MEASUREMENTS WHICH MAY BE FOUND AS PLANNED AND IF NECESSARY SAND PAPERED. SUBSTRATE AT THE FOLLOWING LOCATIONS: • JUNCTIONS
INDICATED ON THE DRAWINGS. THE CONTRACTOR SHALL ASSUME CONTROL AND PROTECTION USE APPROVED GOOD LUMBER FOR ALL ROUGH WOOD WORKS. BETWEEN DIFFERENT SUBSTRATE MATERIALS. • ABUTMENTS WITH
FULL AND UNDIVIDED RESPONSIBILITY FOR THE ACCURACY, FIT AVOID EROSION, CONTAMINATION, AND SEDIMENTATION OF THE ALL LUMBER IN CONTACT WITH MASONRY SHALL BE TREATED OTHER FINISHES. • ABUTMENTS WITH DOOR FRAMES.
AND STABILITY OF ALL PARTS OF THE WORK. SITE, SURROUNDING AREAS, AND DRAINAGE SYSTEMS. ENSURE WITH APPROVED WOOD PRESERVATIVES OR TERMITE PROOFING
2. DO NOT SCALE THE DRAWINGS. REFER TO THE WRITTEN THAT WASHOUT DOES NOT ENTER WATERWAYS OR STORMWATER COMPOUND. CONTROL JOINTS
DIMENSIONS PROVIDED. DRAINS. ENSURE THAT THERE ARE NO CROSS CONNECTIONS PROVIDE CONTROL JOINTS 3 TO 6 MM WIDE IN THE FINISH TO
3. ALL LABOR, MATERIALS AND INSTALLATIONS MUST COMPLY BETWEEN STORMWATER SYSTEMS AND SEWERAGE SYSTEMS. THERMAL AND MOISTURE PROTECTION COINCIDE WITH CONTROL JOINTS IN THE SUBSTRATE. FINISH WITH
WITH THE CODES, RULES AND REGULATIONS OF ALL AUTHORITIES KEEP EARTHWORKS AND THE SITE OF THE WORKS FREE OF GROUND SLAB VAPOUR BARRIER RONDO STOPPING BEADS AND FILL WITH A RESILIENT SEALANT.
HAVING JURISDICTION. ANY DISCREPANCY WHICH EXISTS EXCESS WATER. PROVIDE AND MAINTAIN SLOPES, CROWNS, PROVIDE A VAPOUR BARRIER UNDER SLABS ON GROUND
BETWEEN THE REQUIREMENTS BY THE PLANS, SPECIFICATIONS, DRAINS, EXCAVATIONS AND EMBANKMENTS TO ENSURE FREE INCLUDING INTEGRAL GROUND BEAMS AND FOOTINGS. STANDARD
CODES, RULES AND REGULATIONS SHALL BE IMMEDIATELY DRAINAGE. PLACE CONSTRUCTION, INCLUDING FILL, MASONRY, VAPOUR BARRIERS AND DAMP PROOF MEMBRANES: TO AS 2870 PAINTING
BROUGHT TO THE ATTENTION OF THE ARCHITECT, IN WRITING FOR CONCRETE AND SERVICES, ON GROUND FROM WHICH FREE CLAUSE 5.3.3. PROPRIETARY ITEM: FORTECON INSTALLATION LAY ALL PAINTS TO BE USED SHALL BE BOYSEN AND THE FOLLOWING
RESOLUTION. WATER HAS BEEN REMOVED. PREVENT WATER FLOW OVER OVER THE BASE, LAP JOINTS 200 MM AND SEAL THE LAPS AND SHALL BE FOLLOWED:
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY FRESHLY LAID WORK. PENETRATIONS WITH WATERPROOF ADHESIVE TAPE. SEAL FOR EXTERIOR & INTERIOR MASONRY, USE BOYSEN TITAN
BRACING AND PROTECTING ALL WORK DURING CONSTRUCTION PUNCTURES AND TEARS WITH WATERPROOF TAPE BEFORE ELASTOMERIC PAINT W/ PRIMER COAT & 2 FINAL COATS
AGAINST DAMAGE, BREAKAGE, COLLAPSE, DISTORTION AND EXCAVATION POURING CONCRETE.
MISALIGNMENT ACCORDING TO THE APPLICABLE CODES AND SITE SURFACE: EXCAVATE TO GIVE THE LEVELS AND PROFILES PAINTING COVERS COMPLETE PAINTING AND FINISHING OF
STANDARDS. REQUIRED FOR CONSTRUCTION, SITE SERVICES, PAVING, AND DOORS AND WINDOWS WOOD, PLASTERS, CONCRETE, METAL OR OTHER
5. THE CONTRACTOR SHALL COORDINATE THE WORK WITH LANDSCAPING. ALLOW FOR COMPACTION OR SETTLEMENT OR WOOD DOORS SURFACES, EXTERIOR OR INTERIOR OF THE BUILDING. ALL PAINT
MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ALL HEAVING. PROPRIETARY DOORS MANUFACTURED FOR INTERIOR OR MATERIALS SHALL MEET THE REQUIREMENTS OF PAINT
NECESSARY OPENINGS THROUGH WALLS, CEILINGS AND FLOORS. FOOTINGS: EXCAVATE FOR FOOTINGS TO THE REQUIRED SIZES EXTERIOR APPLICATIONS AND FOR THE FINISH REQUIRED. MATERIALS UNDER CLASSIFICATION CLASS “A”. ALL COLORS
6. ALL MATERIALS AND CONSTRUCTION TO BE INCORPORATED IN AND DEPTHS. CONFIRM THAT THE FOUNDATION CONDITIONS MEET SHALL BE IN ACCORDANCE WITH SAMPLES TO BE APPROVED BY
THE WORK SHALL BE IN STRICT ACCORDANCE WITH THE LATEST THE DESIGN BEARING CAPACITY. PAINTING THE OWNER OF THE BUILDING WITH THE ADVICE OF THE
EDITION OF THE ASTM SPECIFICATIONS APPLICABLE AND SHALL FOUNDATIONS: AFTER EXCAVATION, CONFIRM THAT THE BEARING PRIMING: PRIME ALL AREAS SUBJECTED TO PAINT REMOVAL ARCHITECT IN CHARGE OF CONSTRUCTION.
CONFORM TO THE STANDARDS AND RECOMMENDATIONS OF THE CAPACITY IS ADEQUATE. DURING THE COURSE OF FITTING HINGE HOUSINGS, LOCKS AND ALL PAINTS AND OTHER COATINGS SHALL BE MIXED AND APPLIED
VARIOUS TRADE INSTITUTES (ACI, AISC ETC.) WHERE APPLICABLE. BEARING SURFACES: PROVIDE EVEN PLANE BEARING SURFACES THE LIKE, PRIOR TO HANGING. STRICTLY IN ACCORDANCE WITH THE MANUFACTURERS PRINTED
FOR LOADBEARING ELEMENTS INCLUDING FOOTINGS. STEP TO PAINTING: WITHIN FORTY-EIGHT HOURS OF HANGING AND PRIOR INSTRUCTIONS.
ARCHITECTURAL ACCOMMODATE LEVEL CHANGES. MAKE THE STEPS TO THE
APPROPRIATE COURSES IF SUPPORTING MASONRY.
TO THE INSTALLATION OF DOOR HANDLES, WEATHER EXCLUDERS
AND THE LIKE (LATCHES AND LOCKS EXCEPTED), UNDERCOAT ALL TILEWORKS
SPECIFICATIONS GRADING: EXTERNAL AREAS: GRADE TO GIVE FALLS AWAY FROM
BUILDINGS, MINIMUM 2%. GRADE THE GROUND SURFACE UNDER
SURFACES, FOLLOWED BY A MINIMUM 1 FINISHING COAT TO ALL
SURFACES INCLUDING TOP AND BOTTOM EDGES. THE FINAL COAT
VINYL FLOOR TILES
INSTALLATION OF VINYL TILES SHALL NOT COMMENCE UNTIL
GENERAL REQUIREMENTS
SUSPENDED FLOORS AND EXTERNALLY TO DRAIN GROUND OR MAY BE APPLIED AT A LATER STAGE. INTERIOR PAINTING HAS BEEN COMPLETED.
THE WORKS UNDER THIS PROJECT SHALL CONFORM TO ALL THE
SURFACE WATER AWAY FROM BUILDINGS WITHOUT PONDING. FLOOR SURFACES THAT ARE TO RECEIVE VINYL TILES SHALL BE
TECHNICAL DRAWINGS, PLANS AND ALL SPECIFICATIONS HERE
ALUMINUM WINDOW CLEAN, THOROUGHLY DRY, SMOOTH, FIRM AND SOUND, FREE
UNTO STATED. ALL DIMENSIONS, LINES, GRADES SHALL BE IN
PROTECTION, PUMPING & MAINTENANCE WINDOWS SHALL BE OF SLIDING TYPE U.N.O.; 4MM THICK CLEAR FROM OIL, PAINT, WAX AND ANY OTHER DAMAGING MATERIALS.
ACCORDANCE WITH THE NATIONAL BUILDING CODE. OTHER CODES
THE CONTRACTOR SHALL AT ALL TIMES PROTECT THE GLASS ON POWDER COATED ALUMINUM FRAME, AND SHALL BE
APPLICABLE THEREIN SHALL ALSO BE COMPLIED WITH.
EXCAVATIONS AND TRENCHES FROM DAMAGES FROM RAIN TRUE TO THE DIMENSIONS AND PLACEMENTS AS INDICATED IN BATHROOM HOMOGENOUS TILES
THE CONSTRUCTION SHALL COMPLETE ALL PHASES OF WORKS AS
WATER AND ALL OTHER SOURCES OF WATER. THE PLANS. DETERMINE AND MARK LAYOUT OF TILES AS TO JOINT LOCATION,
SHOWN IN THE DRAWINGS. THE BUILDING LINES SHALL BE LAID
HE SHALL PROVIDE AND OPERATE ALL PUMPS OR OTHER POSITION OF TRIMS AND FIXTURES SO AS TO MINIMIZE CUTTING
OUT ACCURATELY WITHIN THE LOT AND ALL OTHER
EQUIPMENT NECESSARY TO DRAIN AND KEEP EXCAVATIONS, PITS FINISHES LESS THAN ONE HALF SIZE OF THE TILE.
MEASUREMENTS SHALL BE CORRECTLY VERIFIED. NO PART OF
TRENCHES AND THE ENTIRE SUB-GRADE AREA FREE OF WATER WOOD BEFORE GROUTING OF JOINTS, TILES SHALL HAVE BEEN LAID IN
THIS BUILDING WITH WINDOW OPENING SHALL BE LESS THAN TWO
UNDER ANY CIRCUMSTANCES AND CONTINGENCIES THAT MAY TANGUILE - FOR ALL EXPOSED WOOD WORKS SUCH AS DOOR PLACE FOR AT LEAST 24 HOURS. GROUTING MORTAR SHALL BE
(2) METERS FROM THE BOUNDARY OF THE LOT, UNLESS THE
ARISE. JAMBS, FRAMES, JOISTS AND CABINETS. WHITE CEMENT WITH GROUT SEALER. CLEAN TILE SURFACE
DIMENSIONS OF THE LOT WILL NOT ALLOW, IN WHICH CASE A
HE SHALL BUILD ALL NECESSARY ENCLOSURES, CONSTRUCT AND THOROUGHLY AS POSSIBLE UPON COMPLETION OF GROUTING
CONCRETE FIREWALL EXTENDING AT LEAST FIVE HUNDRED (500)
MAINTAIN TEMPORARY DRAINAGE FOR THIS PURPOSE. HE SHALL FIBERCEMENT
MILLIMETERS ABOVE THE RIDGE OF THE ROOFING SHALL BE
PROVIDE ALL SHORING, BRACING AND SHEATHING AS REQUIRED 6mm THK HARDIFLEX BOARD - TO BE USED FOR CEILING FINISHES WATERPROOFING
ERECTED ON THE SIDE IN WHICH IS LESS THAN TWO METERS
FOR SAFETY, OR NECESSARY TO SUPPORT ADJOINING WALLS, IN BATHROOM AND TOILETS. INTEGRAL WATERPROOFING (CONCRETE TOPPING) SHALL BE 1
FROM THE LOT LINE.
WALKS, SOILS, STREETS, BUILDINGS, FENCES AND THE LIKE FOR PART PORTLAND CEMENT, 3 PARTS FINE SAND AND 1 KILO
THE PROSECUTION OF THE WORK. ALL THESE TO BE REMOVED PLAIN CEMENT PLASTER (OVER MASONRY) 'SAHARA' ADMIXTURE.
SITE CONSTRUCTION
WHEN WORK IS COMPLETED AND/ OR REQUIRED BY OWNER. JOINTS AND PLASTERING MORTAR SHALL BE COMPOSED OF ONE MEMBRANE WATERPROOFING SHALL BE 'PRIMERO' ELASTOMERIC
SITE CLEARING
THE CONTRACTOR SHALL PROTECT THE EXCAVATION TO BE MADE PART HOLCIM WALLRIGHT CEMENT AND FOUR (4) PARTS SIFTED OR APPROVED EQUAL. MIXTURE SHALL BE APPLIED BY ROLLER,
LIMIT CLEARING TO AREAS OF CUT AND FILL AND AREAS TO BE
BELOW EXISTING GRADE LINE SO THAT THE SOIL OF THE FINE SAND. CLEAN WATER SHALL BE ADDED TO THIS MIXTURE TO PAINT BRUSH OR AIRLESS SPRAY AND SHALL REMAIN TIGHT
OCCUPIED BY CONSTRUCTION, PAVING, LANDSCAPE WORK OR TO
ADJOINING PROPERTY WILL NOT CAVE-IN OR SETTLE AND SHALL FORM A WORKABLE PASTE. UNDER CONDITIONS OF EXPANSION, CONTRACTION AND
OTHER DESIGNATED AREAS. REMOVE EVERYTHING ON OR ABOVE
DEFRAY THE COST OF UNDERPINNING OR EXTENDING THE SURFACE SHALL BE WETTED BEFORE PLASTERING, AND THE VIBRATION OF LOADS.
THE SITE SURFACE, INCLUDING RUBBISH, SCRAP, GRASS,
FOUNDATION OF BUILDINGS ON ADJOINING PROPERTIES. FINISHED SURFACE SHALL BE KEPT WET FOR AT LEAST 72 HOURS. THREE APPLICATIONS IS RECOMMENDED AND EACH COAT IS
VEGETABLE MATTER AND ORGANIC DEBRIS, SCRUB, TREES,
READY MIX SKIM COAT SHALL BE APPLIED TO ALL INTERIOR ALLOWED A MINIMUM OF 24 HOURS CURING TIME BETWEEN EACH
TIMBER, STUMPS, BOULDERS AND RUBBLE. REMOVE GRASSED
FILL SURFACES U.N.O. COAT OR AS RECOMMENDED IN THE PRODUCT MANUFACTURERS
SOIL TO A DEPTH JUST SUFFICIENT TO INCLUDE THE ROOT ZONE.
PLACE FILL IN NEAR HORIZONTAL LAYERS OF UNIFORM THICKNESS WORKMANSHIP: INSTRUCTION MANUAL.
MULCH ALL DEMOLISHED AERIAL VEGETATION AND REDUCE TO
NO GREATER THAN 200 MM AFTER COMPACTION, DEPOSITED PLASTER WORK SHALL BE FINISHED LEVEL, PLUMB, SQUARE AND
PIECES NOT LARGER THAN 75 X 50 X 15 MM AND STOCKPILE FOR
REUSE OR REMOVE FROM SITE.
SYSTEMATICALLY ACROSS THE FILL AREA. COMPACT EACH LAYER TRUE TO LINE WITHIN A TOLERANCE OF 3mm (81") IN 3.00 METERS
TO ACHIEVE THE REQUIRED DENSITY. MAXIMUM DEPTH OF SAND WITHOUT CRACKS, WAVES, BLISTERS, PITS, CRAZING,
FILL: 400 MM. DISCOLORATIONS, PROJECTIONS AND OTHER IMPERFECTIONS.
REMOVAL OF TOPSOIL
REMOVE THE TOPSOIL LAYER OF THE NATURAL GROUND WHICH 1. PLASTER WORK SHALL BE FORMED CAREFULLY AROUND
CONCRETE ANGLES, CONTOURS AND WELL-UP TO SCREEDS.
CONTAINS SUBSTANTIAL ORGANIC MATTER OVER THE AREAS TO
(REFER TO STRUCTURAL SPECIFICATIONS) 2. SPECIAL CARE SHALL BE TAKEN TO PREVENT SAGGING AND
BE OCCUPIED BY CONSTRUCTION AND PAVING. MAXIMUM DEPTH:
MASONRY CONSEQUENT DROPPING OF MORTAR DURING APPLICATIONS.
200 MM.
(REFER TO STRUCTURAL SPECIFICATIONS) 3. THERE SHALL BE NO VISIBLE JUNCTION MARKS IN THE FINAL

JA
CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.
GENERAL NOTES & SPECIFICATIONS
PROPOSED HOUSE EXTENSION (3-LEVEL)
JUSTINE & JOYCE D. CALDERON A-002
SB
JUAN ALEXANDER S. BARREDO Architect, Leed AP Lot 8, Block 2, Black Ash Street, Richview Subdivision,
PRC NO. 16394 VALIDITY: November 18, 2018 Bakakeng, Baguio City, Philippines 31 Unit G. Agno Street, Quezon City, Metro Manila
PTR NO. 3596747 DATE: March 16, 2018
PLACE: Baguio City TIN: 471-545-699
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR BLDG PERMIT APPLICATION
A-301

A-301
AA

AA
1 2 3 1 2 3
3000 6000 ±3002 3000 6000 ±3002
CLEAR

150 1000 850 1350 3575 775 1300 750


1000

1000 2200 13 EQ. TREADS @ 275 EACH


8 EQ @ 275 EACH

C C
400

retaining wall retaining wall retaining wall


DIV INTO 13 EQ TREADS @ 275

1 2 3 4 5 6

EQ
CLEAR

1424
desk

950
A-302

A-302
UP
STORAGE W4

BB

BB
2100

EQ
POWDER

EQ

1m high wall
potted plants

3200
clerestory window
3575

fixed window

D203
D202
1524x2032

600
W1
queen 1000 ref sink stove BAL

D204
tv

3300
EQ W9 KITCHEN

6075

6075
ACCESSIBLE 450
handrail

±2494
inside cabinet
murphy bed

SUITE 15 rail
1100
CARPORT UP

LAWN
FFL=0.05
1000 875

1624
±1500

closet slab w/ 2% slope to drain


900

1700 1490 550 ENTRY DINING


1200 D201
675
14 DN rail LIVING ROOM
600

ref

830
below
DIV INTO 12 EQ TREADS @ 275

T&B

250 1000
2600

D102 600 200 W5

potted plants
FFL=0.05
±1288

B 1200 B

1000
300 300
D101

450 450
TV

3800
750

600

600
3300

400 1200x3800 400

1250
septic tank below

400 500
400 400 W6
A A

250
W2 W8 W7
W3
BUILDING

975 2915 slab w/ 2% slope


railing

200 ±593
LAWN 225
2400
1200 300 1000 2800
275
SE

2 open to below

±3145

±3145
4000
TBACK @ FR

UP
1200 2365 2200 502
1200

EQ DN
D104
1856

UP 2400
EQ
1006

at
400 high se 1
300

ONT

400
D103
5660
250

1000

LAWN
LAWN UP 4246
1005

800 900
SIDEWALK
WALL TYPES:
FFL=0.00

Existing wall to be retained/ repaired

125mm chb wall w/ min. 1/2" thick plaster on both sides

Option 1: 2x4 steel studs w/ fiberglass batt insulation.


19mm gypsum wall board on both sides
LEVEL 1 LEVEL 2 Option 2: M2 panel with cement plaster, both sides

1
FLOOR PLAN 2
FLOOR PLAN Monolithic concrete wall (use vibrator). Straight to finish
1:75 M 1:75 M Note:
Use Holcim Wallright for cement plastering works.

JA
CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.
FLOOR PLANS
PROPOSED HOUSE EXTENSION (3-LEVEL)
JUSTINE & JOYCE D. CALDERON A-101
SB
JUAN ALEXANDER S. BARREDO Architect, Leed AP Lot 8, Block 2, Black Ash Street, Richview Subdivision,
PRC NO. 16394 VALIDITY: November 18, 2018 Bakakeng, Baguio City, Philippines 31 Unit G. Agno Street, Quezon City, Metro Manila
PTR NO. 3596747 DATE: March 16, 2018
PLACE: Baguio City TIN: 471-545-699
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR BLDG PERMIT APPLICATION
EXISTING HOUSE TO REMAIN

A-301

A-301
AA

AA
1 2 3 1 2 3
3000 6000 ±2852 3000 6000 ±2852

350300 1000 700 3225 1040 1035 950 950 3200 300 3200 950

300
area drain catch basin
75

outline of existing CHB wall to be removed


C 1m high hand railing C

850
2 3 4 5 6 7 8 9 10 11 12 13 14
1500

A-302
clear

A-302
950
DN W4

BB

BB
sliding
W4

1200
T&B D304 T&B
950

slab topping slab topping


HALLWAY D301

200mm high concrete curb


w/ 2% slope w/ 2% slope
1350

200mm high concrete curb


slab slab

1055
D305 600x
topping topping
900
3
30 D
600x
w/ 2% w/ 2%
30 slab topping

6075

6075
900
D
600x 2 W10 slope w/ 2% slope slope
1000

1200
2740 2280 2730
open to
main 100 100
400

W14
entry

outline of level below


2970
below
BDRM 1 BDRM 2
1375

MBR

B B
188

W12
250 800

W13 200mm high concrete curb


120 479

120 465
600

600
530

W11
slope A slab topping A
250

slab w/ 2% 200
530

400 w/ 2% slope 950


400

1200

1365
1600
950
200 800 277
open to below
building setb

±3145

±3145
1650
4000
ack

WALL TYPES:

Existing wall to be retained/ repaired

125mm chb wall w/ min. 1/2" thick plaster on both sides

LEVEL 3 Option 1: 2x4 steel studs w/ fiberglass batt insulation.


19mm gypsum wall board on both sides

1
FLOOR PLAN 2
ROOF PLAN Option 2:
Note:
M2 panel with cement plaster, both sides

1:75 M 1:75 M Use Holcim Wallright for cement plastering works.

JA
CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.
FLOOR PLAN, ROOF PLAN
PROPOSED HOUSE EXTENSION (3-LEVEL)
JUSTINE & JOYCE D. CALDERON A-102
SB
JUAN ALEXANDER S. BARREDO Architect, Leed AP Lot 8, Block 2, Black Ash Street, Richview Subdivision,
PRC NO. 16394 VALIDITY: November 18, 2018 Bakakeng, Baguio City, Philippines 31 Unit G. Agno Street, Quezon City, Metro Manila
PTR NO. 3596747 DATE: March 16, 2018
PLACE: Baguio City TIN: 471-545-699
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR BLDG PERMIT APPLICATION
600 EQ EQ

EQ EQ

EQ EQ

EQ EQ
open to
3rd level CF-1 CF-2

1500
above

EQ
CF-2
EQ EQ CF-2

600

600

600

600
EQ EQ
CF-1
600 EQ EQ EQ 600

EQ

3000
CF-1 400
CF-1
S

1200
900
EQ

EL
CF-2
EQ EQ 600

600

600
EQ EQ
EQ

600

600
S
CF-1

CF-1
CF-1

LEVEL 1 LEVEL 2
1
REFLECTED CEILING PLAN 2
REFLECTED CEILING PLAN
1:75 M 1:75 M

EQ EQ
LEGEND:

EQ
EQ EQ
EQ
EQ

EQ EQ
CF-1 LED LIGHT FIXTURE
CF-2
EQ
EQ

CF-2 S
LED CHANDELIER
EQ

6W LED LIGHT W/ BUILT-IN SWITCH ATTACHED TO OVERHEAD CABINET /


6W LED STRIP LIGHTING CONCEALED IN COVE
EQ
2000

CF-1
EQ EQ
EQ

WALL MOUNTED LED LIGHT FIXTURE (W/ OPTIONAL MOTION SENSOR)


EQ EQ
EQ EQ
S 2 IN 1 SMOKE & HEAT DETECTOR (BATTERY)
CF-1
CF-1 EL EMERGENCY LIGHT (RECHARGABLE)
EQ

CF-1
EQ

CF-1 EXPOSED UNDERSIDE OF STEEL DECKING BY COLORSTEEL. WHITE


CF-2 4.5mm THK FIBERCEMENT DROP CEILING ON 1X2 G.I. PURLINS. ENSURE
CLEARANCE OF 2.2m CLEAR HEIGHT FROM FFL. 3 COATS SEMI-GLOSS
CF-1
SHEET NOTES:
1. REFER TO ELECTRICAL PLANS FOR ADDITIONAL INFORMATION.
2. CEILING DROP (IF REQUIRED BY OWNER) SHALL NOT BE MORE THAN 50mm
LEVEL 3 3. ALL POWER OUTLETS, LIGHTING FIXTURES SHALL BE OWNER SUPPLIED
4. STEEL DECKING SHALL BE MANUFACTURED BY 'COLORSTEEL' OR APPROVED EQUAL.

3
REFLECTED CEILING PLAN VERIFY WITH ARCHITECT STEEL DECKING TYPE AND COLOR
5. PROVIDE 'DRIP EDGING' AROUND SLAB PERIMETER EXPOSED TO WEATHER
1:75 M

JA
CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.
REFLECTED CEILING PLAN
PROPOSED HOUSE EXTENSION (3-LEVEL)
JUSTINE & JOYCE D. CALDERON A-111
SB
JUAN ALEXANDER S. BARREDO Architect, Leed AP Lot 8, Block 2, Black Ash Street, Richview Subdivision,
PRC NO. 16394 VALIDITY: November 18, 2018 Bakakeng, Baguio City, Philippines 31 Unit G. Agno Street, Quezon City, Metro Manila
PTR NO. 3596747 DATE: March 16, 2018
PLACE: Baguio City TIN: 471-545-699
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR BLDG PERMIT APPLICATION
MATERIAL LEGEND
1.1 PAINTED; TITAN ELASTOMERIC; 3 COATS DARK GRAY* (ROUGH FIN)
1.2 PAINTED; TITAN ELASTOMERIC; 3 COATS DOVE GRAY (ROUGH FIN)
1.3 PAINTED; TITAN ELASTOMERIC; 3 COATS BANNISTER WHITE (SMOOTH FIN)

2.1 CONCRETE STRAIGHT TO FINISH; USE CONCRETE VIBRATOR

3.1 UPVC WINDOW FRAME W/ 6mm THK CLEAR GLASS; COLOR WHITE

4.1 STEEL GATE, BALLUSER & FENCE; DAVIES AQUA GLOSS 'PITCH BLACK'

5.1 SOLID WOOD DOOR; STAINED FINISH

7.1 STEEL RAILING (PAINTED 'PITCH BLACK') W/ CLEAR TEMPERED GLASS

8.1 2X6 ALUMINUM TRIM (LAID HORIZONTALLY)

PL PL

1 2 3 A B C
1.2 1.1 3.1 PL 1.1 1.1 3.1 8.1
ROOF LEVEL ROOF LEVEL
FFL=8.10 m FFL=8.10 m

7.1
2700

2700
1.2
1.1
LEVEL 3 1.3 LEVEL 3
FFL=5.40 m FFL=5.40 m
1.3

2700
8100
2700

8100
4.1 1.3
2.1 1.1

LEVEL 2 LEVEL 2
FFL=2.70 m FFL=2.70 m
2700

2700
LEVEL 1 LEVEL 1
top of sidewalk top of sidewalk
0.00 m 0.00 m

1.3 2.1 1.1 4.1 1.3 2.1 2.1 3.1 1.3 1.2 1.1

1
EAST ELEVATION 2
NORTH ELEVATION
1:75 M 1:75 M

JA
CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.
BUILDING ELEVATIONS
PROPOSED HOUSE EXTENSION (3-LEVEL)
JUSTINE & JOYCE D. CALDERON A-201
SB
JUAN ALEXANDER S. BARREDO Architect, Leed AP Lot 8, Block 2, Black Ash Street, Richview Subdivision,
PRC NO. 16394 VALIDITY: November 18, 2018 Bakakeng, Baguio City, Philippines 31 Unit G. Agno Street, Quezon City, Metro Manila
PTR NO. 3596747 DATE: March 16, 2018
PLACE: Baguio City TIN: 471-545-699
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR BLDG PERMIT APPLICATION
MATERIAL LEGEND
1.1 PAINTED; TITAN ELASTOMERIC; 3 COATS DARK GRAY* (ROUGH FIN)
1.2 PAINTED; TITAN ELASTOMERIC; 3 COATS DOVE GRAY (ROUGH FIN)
1.3 PAINTED; TITAN ELASTOMERIC; 3 COATS BANNISTER WHITE (SMOOTH FIN)

2.1 CONCRETE STRAIGHT TO FINISH; USE CONCRETE VIBRATOR

3.1 UPVC WINDOW FRAME W/ 6mm THK CLEAR GLASS; COLOR WHITE

4.1 STEEL GATE, BALLUSER & FENCE; DAVIES AQUA GLOSS 'PITCH BLACK'

5.1 SOLID WOOD DOOR; STAINED FINISH

7.1 STEEL RAILING (PAINTED 'PITCH BLACK') W/ CLEAR TEMPERED GLASS

8.1 2X6 ALUMINUM TRIM (LAID HORIZONTALLY)

PL PL

C 3.1 1.3 3.1 1.1 B A 3 4.1 2 1.3 1.1 1

ROOF LEVEL ROOF LEVEL


FFL=8.10 m FFL=8.10 m
PL

2700
3.1

2.1
LEVEL 3 LEVEL 3
FFL=5.40 m FFL=5.40 m
8.1

2700
8100
1.1
5.1
2
WEST ELEVATION
1:75 M
LEVEL 2
FFL=2.70 m
7.1
2700

LEVEL 1
top of sidewalk
0.00 m

1
SOUTH ELEVATION
1:75 M

JA
CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.
BUILDING ELEVATIONS
PROPOSED HOUSE EXTENSION (3-LEVEL)
JUSTINE & JOYCE D. CALDERON A-202
SB
JUAN ALEXANDER S. BARREDO Architect, Leed AP Lot 8, Block 2, Black Ash Street, Richview Subdivision,
PRC NO. 16394 VALIDITY: November 18, 2018 Bakakeng, Baguio City, Philippines 31 Unit G. Agno Street, Quezon City, Metro Manila
PTR NO. 3596747 DATE: March 16, 2018
PLACE: Baguio City TIN: 471-545-699
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR BLDG PERMIT APPLICATION
PL

C B A
PROVIDE 2"X2"
CONCRETE 'CANT' STRIP. CONCRETE SLAB TOPPING W/ 2% SLOPE.
APPLY 'PRIMERO' ELASTOMERIC WATER
ENSURE 2% SLOPE TO DRAIN PROOFING. COLOR GREY
EXISTING HOUSE & REPAIR ANY LARGE CRACKS ROOF LEVEL
TO REMAIN IN SLAB. APPLY 3 LAYERS OF FFL=8.10 m
'PRIMERO' WATERPROOFING
(NOT PART OF WORK)

200
TO ENSURE NO MOISTURE
PENETRATES INTO SOIL ROUGH FINISH CEMENT PLASTER.
BELOW. APPLY 3 COATS TITAN ELASTOMERIC

2700
APPLY MOISTURE BARRIER BELOW
SLAB. CONCRETE SLAB TOPPING W/ 2% SLOPE.

200
APPLY 'PRIMERO' ELASTOMERIC WATER
PROOFING. COLOR GREY
APPLY MOISTURE BARRIER BETWEEN MASTERS BEDROOM LEVEL 3
ENTIRE HEIGHT OF RETAINING WALL PROVIDE DRIP MOLD AROUND ENTIRE FFL=5.40 m
AND GROUND. PROVIDE 12" OVERLAPS &
SLAB PERIMETER. USE 21"X21" ALUMINUM
SECURE EVENLY BY DUCT TAPE
ANGLE BAR ADHERED TO SLAB ABOVE.
SILICONE ALL VISIBLE GAPS BETWEEN
UNDISTURBED ANGLE BAR AND SLAB

8100
2700
SOIL
PL
SEE STRUCTURAL SECTION FOR APPLY EXTERIOR GRADE SEALANT

100
RETAINING WALL DETAILS. AROUND ALL EDGES. COLOR TO

200
SHEET S-104 LIVING MATCH WINDOW FRAME
STO KITCHEN ROOM LEVEL 2
FFL=2.70 m
CONTRACTOR TO PROVIDE SOIL
RETENTION MEASURES TO OWNER AND
ENGINEER PRIOR TO IMPLEMENTATION.

2700
APPLY MOISTURE BARRIER BETWEEN
ENTIRE HEIGHT OF RETAINING WALL

750
AND GROUND. PROVIDE 12" OVERLAPS & DRIVEWAY LEVEL 1
SECURE EVENLY BY DUCT TAPE
ACCESSIBLE SUITE BEYOND top of sidewalk
0.00 m
REFER TO S-104 FOR FOOTING DEPTH
PROVIDE MOISTURE PROVIDE ALUMINUM OR STAINLESS
BARRIER BELOW STEEL DOOR THRESHOLD. MAXIMUM
SLAB 10mm LIP. SLOPE EXTERIOR SLAB 2%
UNDISTURBED SOIL AWAY FROM BUILDING.

1
BUILDING SECTION THRU 'AA'
1:75 M

JA
CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.
BUILDING SECTION
PROPOSED HOUSE EXTENSION (3-LEVEL)
JUSTINE & JOYCE D. CALDERON A-301
SB
JUAN ALEXANDER S. BARREDO Architect, Leed AP Lot 8, Block 2, Black Ash Street, Richview Subdivision,
PRC NO. 16394 VALIDITY: November 18, 2018 Bakakeng, Baguio City, Philippines 31 Unit G. Agno Street, Quezon City, Metro Manila
PTR NO. 3596747 DATE: March 16, 2018
PLACE: Baguio City TIN: 471-545-699
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR BLDG PERMIT APPLICATION
PL
1 2 3
PL

200
ROOF LEVEL
FFL=8.10 m

300

2700
2200

2200
OUTLINE OF FLOOR BEYOND

MBR
T&B T&B
LEVEL 3

DIVIDE INTO 14 EQUAL

500
FFL=5.40 m

RISERS AT 192mm
275
TYP

CLEAR
2061

2700
8100
2200

1000
POWDER
STORAGE ROOM
LEVEL 2

200
FFL=2.70 m

2700
750 LEVEL 1
ACCESSIBLE SUITE 2 CAR GARAGE top of sidewalk
0.00 m

1
BUILDING SECTION THRU 'BB'
1:75 M

JA
CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.
BUILDING SECTION
PROPOSED HOUSE EXTENSION (3-LEVEL)
JUSTINE & JOYCE D. CALDERON A-302
SB
JUAN ALEXANDER S. BARREDO Architect, Leed AP Lot 8, Block 2, Black Ash Street, Richview Subdivision,
PRC NO. 16394 VALIDITY: November 18, 2018 Bakakeng, Baguio City, Philippines 31 Unit G. Agno Street, Quezon City, Metro Manila
PTR NO. 3596747 DATE: March 16, 2018
PLACE: Baguio City TIN: 471-545-699
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR BLDG PERMIT APPLICATION
1000

1000
400
2400
2400 800 1600
900 400 750 600 1000
slab soffit
700 1500

400

400

900

500
1500

1600

1600

1600
1100

1200
2300

1900
±2100

±1600

1600
±1000

200 700

700

200 700

200 700
200

200
FFL
1 PC 1 PC 1 PC 3 PCS 1 PC 1 PC 1 PC 1 PC 1 PC, fixed
W1 Accessible Suite W2 Accessible Suite W3 Accessible Toilet W4 2F Powder Rm W5 2F Dining Area W6 2F Dining Area W7 2F Living Area W8 2F Living Area W9 2F Entrance
(viewed from outside) (viewed outside) (viewed outside) 3F Common & MBR T&B (viewed outside) (viewed outside) (viewed outside) (viewed outside) (viewed outside)
(viewed outside)

1200
slab soffit WINDOW NOTES:
400
400 1. ALL WINDOWS SHALL BE POWDER COATED ALUMINUM FRAME, WHITE / uPVC WHITE W/ 4.5mm THK CLEAR GLASS
2. WINDOW MANUFACTURER/ SUPPLIER SHALL VERIFY SITE MEASUREMENTS PRIOR TO FABRICATION
3. WINDOW MANUFACTURER/ SUPPLIER SHALL SUBMIT FRAME SAMPLE FOR ARCHITECT AND OWNER APPROVAL
1200

1700

TAG WxH MATERIAL DESCRIPTION / LOCATION


200 700

D101 900 X 2100 SOLID WOOD PEEP HOLE, DEAD BOLT, SS HEAVY DUTY HINGES
400

FFL D102 700 X 2100 SOLID WOOD W/ SMOKED GLASS


1 PC 1 PC D103 900 X 1600 STEEL ENTRY GATE WITH LOCK, LATCH AND 3 HINGES
800

W10 3F Bedroom 2 W11 3F Bedroom 2 D104 5660 X 1600 STEEL DOUBLE LEAF VEHICLE GATE W LOCK, LATCH & 3 HINGES
(viewed outside) (viewed outside)

1600 D201 900 X 2100 SOLID WOOD SMOKED GLASS, DEAD BOLT, 4 PCS HEAVY DUTY HINGES
400 1000
slab soffit
D202 700 X 2100 SOLID WOOD KEYLESS LEVER, SS HEAVY DUTY HINGES
D203 700 X 2100 SOLID WOOD W/ SMOKED GLASS
400

D204 1500 X 2000 uPVC/ ALUMINUM SLIDING GLASS DOOR

D301 800 X 2100 SOLID WOOD BDRM


1600

1600

D302 800 X 2100 SOLID WOOD BDRM


D303 700 X 2100 SOLID WOOD W/ SMOKED GLASS
1700

D304 800 X 2100 SOLID WOOD BDRM


D305 600 X 1800 GLASS LATCH (VERIFY MANUFACTURER)
200 700

200 700

NOTES:
1. ALL DIMENSIONS ARE APPROXIMATE AND SHOULD BE CHECK MEASURED ON-SITE BEFORE CONSTRUCTION.
400

FFL 2. ALL HARDWARE SHALL BE STAINLESS STEEL BRUSHED FINISH. OWNER SUPPLIED
1 PC 1 PC 1 PC
3. ALL DOOR HANDLES TO BE LEVER TYPE. OWNER SUPPLIED
W12 3F Bedroom 1 W14 2F Living Area W13 3F MBR
(viewed outside) (viewed outside) (viewed outside)

1
WINDOW SCHEDULE 2
DOOR SCHEDULE
1:50 M 1:50 M

JA
CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.
DOOR SCHEDULE
PROPOSED HOUSE EXTENSION (3-LEVEL) WINDOW SCHEDULE
JUSTINE & JOYCE D. CALDERON A-401
SB
JUAN ALEXANDER S. BARREDO Architect, Leed AP Lot 8, Block 2, Black Ash Street, Richview Subdivision,
PRC NO. 16394 VALIDITY: November 18, 2018 Bakakeng, Baguio City, Philippines 31 Unit G. Agno Street, Quezon City, Metro Manila
PTR NO. 3596747 DATE: March 16, 2018
PLACE: Baguio City TIN: 471-545-699
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR BLDG PERMIT APPLICATION
C B A

centerline of main door


35

div into 7 eq @ 275


1000
CONCRETE STAIRS, PROVIDE ROUNDED
LIGHT BROOM FINISH NOSING EDGE, USE

1925\
EDGING TOOL PROVIDED

275
750 750
28 1
±75

275

1200
A-501

1000
-
1
ENLARGED STAIR PLAN 27
3300
15
1500
14
3300
2
1374
1:50 M div into 12 eq treads @ 275 each div into 12 eq treads @ 275 each

C B A
Top of Landing 35
6.89 m

2030
13X38 SOLID WOOD
(3 COATS SPAR
VARNISH) OVER
LEVEL 3
5.40 m
6X38 FLAT BAR,
900

PAINTED BLACK 27

div into 13 eq risers @180

6890 (verify site measurement)


BALLUSTER FROM
275 275 275 275 tread (typ)
6X38 FLAT BAR.
BOLT TO SIDE OF
2340

CONCRETE STEP
25 nosing (typ)
PROVIDE ROUNDED
180

NOSING EDGE, USE

180
EDGING TOOL
25 PROVIDED LEVEL 2
2.70 m 14
750 750

div into 14 eq risers @180


275 tread typ

centerline of main door


25 nosing, typ

2520

180
2
ENLARGED STAIR SECTION LEVEL 1
top of sidewalk
1
1:50 M 0.00 m

JA
CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.
EXTERIOR STAIRS DETAIL
PROPOSED HOUSE EXTENSION (3-LEVEL)
JUSTINE & JOYCE D. CALDERON A-501
SB
JUAN ALEXANDER S. BARREDO Architect, Leed AP Lot 8, Block 2, Black Ash Street, Richview Subdivision,
PRC NO. 16394 VALIDITY: November 18, 2018 Bakakeng, Baguio City, Philippines 31 Unit G. Agno Street, Quezon City, Metro Manila
PTR NO. 3596747 DATE: March 16, 2018
PLACE: Baguio City TIN: 471-545-699
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR CONSTRUCTION
1

CLEAR
950
STORAGE
A-502
2

2 3 4 5 6 P

UP

1
ENLARGED STAIR PLAN
1:20 M 'BIG ASS PLANKS' VINYL
1200 3575 FLOORING
LEVEL 3
FFL=5.40 m

180 180 180

205
180 180 180 180 180 180 180 180 180 180 180 180 180
CHAMFER SLAB
EDGE AS

1950 (min. headroom clearance)


INDICATED

25

div into 15 eq risers @ 180 each


typ nosing

2700
12
5
FROM 25X300
HARDWOOD

ENLARGED PLANK, STAINED


FINISH. TYP

2
STAIR SECTION STORAGE POWDER
1:20 M POLISHED CONCRETE/ ROOM
'BIG ASS PLANKS' VINYL
FLOORING

155
LEVEL 2
FFL=2.70 m

JA
CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.
INTERIOR STAIRS DETAIL
PROPOSED HOUSE EXTENSION (3-LEVEL)
JUSTINE & JOYCE D. CALDERON A-502
SB
JUAN ALEXANDER S. BARREDO Architect, Leed AP Lot 8, Block 2, Black Ash Street, Richview Subdivision,
PRC NO. 16394 VALIDITY: November 18, 2018 Bakakeng, Baguio City, Philippines 31 Unit G. Agno Street, Quezon City, Metro Manila
PTR NO. 3596747 DATE: March 16, 2018
PLACE: Baguio City TIN: 471-545-699
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR CONSTRUCTION
3000 200
100 600 100 650 100 650 100 600 100

100 400

200

375

100
400

400
ENLARGED
FENCE PLAN

100

1000
1 ±338 575 925 4231 ±5637 300
1:50 M

A FROM 25X25X6 B HEAVY DUTY


BENECO POST
A-503 ANGLE BAR A-503 CYLINDRICAL
HINGE
POURED
100 clear 25X6mm FLAT
EMBED 50mm CONCRETE,
typ BAR BRACING
SACK RUBBED

300
3000

375
ENLARGED 1700
100

1700
775 100
STAIR SECTION

900
2
1:50 M
LEVEL 1 (top of sidewalk)
FFL=0.00 m

180
EQ 1489 EQ

FROM 25X25X6
ANGLE BAR

300
property line

property line
50X50X6 ANGLE
400

BAR EMBEDDED
100

INTO CONCRETE FROM 50X100X2mm


TUBULAR B.I.
CHAMFERED
EDGE FROM 25X25X6
200mm THICK ANGLE BAR

245
CONCRETE WALL,

1650
SACK RUBBED R45 R95
1000 200 375 METAL FINISH: R64 R114
FROM 2X4 KD
1000 -rust converter
SOLID WOOD NUMBER
-1 coat red oxide primer
DEPRESSED
50

100 227
-3 coats boysen aqua 'gloss it'
300 50

36mm INTO
400

EXISTING EXISTING (pitch black)


CONCRETE
200

SIDEWALK SIDEWALK
LEVEL 1 (top of sidewalk)

50
WALL
FFL=0.00 m
600

HOUSE NO.
3
SECTION THRU 'A' 4
SECTION THRU 'B' 5
DETAIL
1:30 M 1:30 M 1:30 M

JA
CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.
FENCE AND GATE DETAILS
PROPOSED HOUSE EXTENSION (3-LEVEL)
JUSTINE & JOYCE D. CALDERON A-503
SB
JUAN ALEXANDER S. BARREDO Architect, Leed AP Lot 8, Block 2, Black Ash Street, Richview Subdivision,
PRC NO. 16394 VALIDITY: November 18, 2018 Bakakeng, Baguio City, Philippines 31 Unit G. Agno Street, Quezon City, Metro Manila
PTR NO. 3596747 DATE: March 16, 2018
PLACE: Baguio City TIN: 471-545-699
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR CONSTRUCTION
JA
CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.
EXTERIOR IMAGES
PROPOSED HOUSE EXTENSION (3-LEVEL)
JUSTINE & JOYCE D. CALDERON A-601
SB
JUAN ALEXANDER S. BARREDO Architect, Leed AP Lot 8, Block 2, Black Ash Street, Richview Subdivision,
PRC NO. 16394 VALIDITY: November 18, 2018 Bakakeng, Baguio City, Philippines 31 Unit G. Agno Street, Quezon City, Metro Manila
PTR NO. 3596747 DATE: March 16, 2018
PLACE: Baguio City TIN: 471-545-699
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR BLDG PERMIT APPLICATION
JA
CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.
INTERIOR IMAGES
PROPOSED HOUSE EXTENSION (3-LEVEL)
JUSTINE & JOYCE D. CALDERON A-602
SB
JUAN ALEXANDER S. BARREDO Architect, Leed AP Lot 8, Block 2, Black Ash Street, Richview Subdivision,
PRC NO. 16394 VALIDITY: November 18, 2018 Bakakeng, Baguio City, Philippines 31 Unit G. Agno Street, Quezon City, Metro Manila
PTR NO. 3596747 DATE: March 16, 2018
PLACE: Baguio City TIN: 471-545-699
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR BLDG PERMIT APPLICATION
GENERAL NOTES : WALL RECEPTACLES AND PLATES
1.All electrical works herein shall comply with the latest edition Receptacle outlets, shall be 15A, 240 V, 2-pole, 3-wire parallel
ENTRANCE CAP LOAD SCHEDULE
of the Phililpine Electrical Code, the rules and regulations of the slot, grounding type. Fixing screws for wiring devices shall be
local utility company and the laws and ordinances of the local CKT VA PER PROTECTION
concealed from sight. Other special purpose receptacle outlets 2-30 mm² THHN NO.
LOAD DESCRIPTION L.O. C.O.
CIRCUIT
VOLTS AMPS
AT AF
FEEDER WIRE CONDUIT SIZE
enforcing authorities concerned. shall be as indicated in the drawings. Outlet devices shall be as
2. The electrical works shall be under the immediate
in 32 mm RSC
manufactured by Panasonic wide sseries or approved equal. 1 15W LED LIGHTING 7 105 230 0.46 15 50 2 - 2.0 mm² THHN 15 mm Ø PVC
supervision of competent duly licensed Electrical Engineer. Locking type and other special purpose receptacle outlets shall 220V, 1 Phase supply 2 15W LED LIGHTING 16 240 230 1.04 15 50 2 - 2.0 mm² THHN 15 mm Ø PVC
3. All materials, devices, fixtures and equipment to be used be as indicated in the drawings. Appropriate weather proof M 3 15W LED LIGHTING 7 105 230 0.46 15 50 2 - 2.0 mm² THHN 15 mm Ø PVC
such as ballast, led lighting, enclosures, wires & cables, shall fitting metal cast alloy boxes shall be provided for convenience
TO EXISTING LPP 4 CONV. OUTLETS 8 1440 230 6.26 20 50 2 - 3.5 mm² THHN 15 mm Ø PVC
have the ICC mark (imported commodity clearance) ; local outlet where indicated to be weather proof. 5 CONV. OUTLETS 8 1440 230 6.26 20 50 2 - 3.5 mm² THHN 15 mm Ø PVC
products shall bear the PS mark. Provide weatherproof metal receptacle plate cover for each
6 CONV. OUTLETS 10 1800 230 7.83 20 50 2 - 3.5 mm² THHN 15 mm Ø PVC

2-30 mm² THHN


4. All electrical equipment shall be properly grounded in

in 32mm Ø RSC
convenience receptacle outlet indicated as weatherproof.
accordance with the requirements of the latest edition of the 7 WATER HEATER 1 3500 230 15.22 30 50 2 - 5.5 mm² THHN 15 mm Ø PVC
Type and color of receptacle outlet and plates shall be as
Philippine Electrical Code. 8 MICROWAVE OVEN 1 1000 230 4.35 20 50 2 - 3.5 mm² THHN 15 mm Ø PVC
selected by the Architect. Appropriate samples of outlets and
5. All electrical materials and equipment to be used in this plates shall be submitted prior to purchase of devices. 9 REFRIGERATOR 1 385 230 1.67 20 50 2 - 3.5 mm² THHN 15 mm Ø PVC
project shall be brand-new and of approved quality and brand. All utility boxes intended for receptacle outlet devices shall be 10 REFRIGERATOR 1 385 230 1.67 20 50 2 - 3.5 mm² THHN 15 mm Ø PVC
specially designed to receive the particular type of receptacle 11 MICROWAVE OVEN 1 1000 230 4.35 20 50 2 - 3.5 mm² THHN 15 mm Ø PVC
12 RANGE 1 1500 230 6.52 20 50 2 - 3.5 mm² THHN 15 mm Ø PVC
PROJECT SPECIFICATIONS: outlet device to be mounted and should be deep enough to
accept and fit the total number of conductors required as per 13 WATER HEATER 1 3500 230 15.22 30 50 2 - 5.5 mm² THHN 15 mm Ø PVC
CONDUIT AND FITTINGS drawings. Receptacle with Ground Fault Circuit Interrupter 14 WATER HEATER 1 3500 230 15.22 30 50 2 - 5.5 mm² THHN 15 mm Ø PVC
Service entrance conduit shall be IMC (Intermediate Metallic (GFCI) shall be rated 15A, 2P, 3 wire grounding type, 240 V, LIGHTING & POWER PANELBOARD (LPP) 15 SPARE 230 20 50 empty empty
Conduit). parallel slot with 15 milliampere current sensitivity. 16 SPARE 230 20 50 empty empty
Polyvinyl Chloride Conduit (PVC), schedule 40, heavy wall, Duplex conveninence outlets shall have a minimum separation
high impact type with factory made bend, couplings and fittings of 20mm between outlet device. MAIN 100A,2P CB (WP) TOTAL 29 34 19900 20 86.53 100 100 2 - 30 mm² THHN 32 mm Ø RSC
and as manufactured by Neltex, Emerald, Atlanta or approved
equal. PVC conduits shall be embedded in concrete slabs or LIGHTING AND POWER PANELBOARD COMPUTATIONS: THEREFORE:
chb walls. Panelboard for use as service disconnecting means shall 15A 15A Ir = (15.22 x 0.25 + 86.52) x 80% D.F. USE: 2-30mm² THHN in 32mm Ø RSC PIPE
conform to UL Standard. Design shall be such that any =72.26 amps
OUTLETS, BOXES, AND FITTINGS individual breaker can be removed without disturbing adjacent 1 2
Outlet boxes shall be fabricated from PVC boxes as follows: units or without loosening or removing supplemental insulation
A. Ceiling light outlets: 40mm deep, 100mm octagonal box
for 1 or 2 raceway entries ; 55mm deep, 100mm
supplied as a means of obtaining clearances. Panelboard shall
be of weatherproof type. A removable circuit directory shall be
15A 20A
2
LOAD SCHEDULE
octagonal box for 3 or more raceway entries provided for each panel board for field markings of function and 3 4 NTS
B. Light control switch: 40mm deep, 50mm x 100mm utility number or each branch circuit. All directories shall be of
box for 1 or 2 raceway entries in one strap ; 55mm deep, incorrodible material with matching clear plastic holder or
50mm x 100mm utility box for 3 switches in 1 strap. jacket.
20A 20A
Mounting height shall be 1200mm above finish floor. 5 6
C. Convenience outlets: 55mm deep utility box. mounting MOLDED CASE CIRCUIT BREAKERS AND SWITCHES:
height shall be 450mm above finish floor. Provide individual circuit breakers, safety switches and
D. TV cable outlets: 55mm deep utility box ; mounting disconnect switches where indicated on plans. Voltage ratings 30A 20A
height shall be 450mm above f.f.l. shall be suitable in each case of service application.
E. Panel boards inside cabinets: mounting height shall be Enclosures shall be General Purpose, NEMA Type I, except
7 8
1800mm above finish floor. where specifically noted on plans or assembled on panel
cabinets. 20A 20A
JUNCTION AND PULL BOXES All protective devices shall meet NEMA and Underwriter’s
Junction and pull boxes, of Code gauge steel, galvanized shall Laboratories, Inc. specifications. 9 10
be provided as indicated or as required for facilitating the Circuit breakers shall consist of a quick-make, quick-break type

30 SQ. MM BCW
pulling of wires and cables. Pull boxes in finished places shall entirely trip-free operating mechanism with contacts, 20A 20A
be located and installed with the permission and to the arc-interrupter and thermal magnetic trip unit for each pole, all
satisfaction of the Architect and Engineers. magnetic trip unit for each pole, all enclosed in a 11 12
All junction and pull boxes on exposed conduit work shall be molded-phenolic case. The thermal magnetic trip unit shall
provided with hubs for threaded pipe entry and covers provided provide time-delayed overload protection, and in case of
with neoprene gaskets. 30A 30A
overload or short circuit current in any one pole. Circuit
breaker shall be trip indicating, with the tripped position of 13 14
WIRES AND CABLES: breaker handle midway between “ON” and “OFF” positions.
All wires shall be copper, soft-drawn and annealed, shall be of Circuit breaker shall be as manufactured by G.E. or approved
98% conductivity, shall be smooth and true of a cylindrical form equal. SPARE SPARE
and variation shall be within 1% of the actual size called for.
All wires and cables shall comply with the requirements of the
15 16
Underwriters Laboratories, the ASTM and ICEA as they apply
to the particular usage.
All wires and cables shall be as manufactured by Phelps
Dodge, American Wires and Cable Columbia, Philflex, Durex,
or approved equal.
Wires and cables for power and lighting system shall be plastic
insulated for 600 volts working pressure type “THHN” unless GROUNDING WIRE
otherwise noted on plans or specified. CONNECTED TO
WALL SWITCHES AND PLATES
G.I. WATER PIPE
Wall switches shall be rated 15A, 240V, 60 Hz.
Switches shall be for flush mounting type and of the quiet type,
spring operated. The type of switches shall be tumbler
operation and the color, plating and appearance of wall plates
SINGLE
shall be as selected by the Architect. Appropriate samples
shall be submitted prior to the purchase of wall switches and
1
LINE DIAGRAM 3
DESIGN ANALYSIS
face plates. Switches and plates shall be as manufactured by NTS NTS
Panasonic Wide Series or approved equal.

CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.


GENERAL NOTES, SPECIFICATIONS
PROPOSED HOUSE EXTENSION (3-LEVEL) SINGLE LINE DIAGRAM, LOAD SCHEDULE

PRC NO. VALIDITY:


Lot 8, Block 2, Black Ash Street, Richview Subdivision,
Bakakeng, Baguio City, Philippines
JUSTINE & JOYCE D. CALDERON
31 Unit G. Agno Street, Quezon City, Metro Manila
DESIGN ANALYSIS E-101
PTR NO. DATE:
PLACE: TIN:
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR BLDG PERMIT APPLICATION
i (3-way)

2 S S
S h
w/ built-in h
d LPP
b 1 switch

f f g g

e,i

S S
f,g

S d
a d e

S
g g

S a,b,c
f f

1
LEVEL 1 LIGHTING LAYOUT 2
LEVEL 2 LIGHTING LAYOUT
1:75 M 1:75 M

i
3 (3-way) LEGEND:
S
S

LED LIGHT FIXTURE, SURFACE MOUNTED


2 i
S

6W LED LIGHT (BUILT-IN SWITCH) ATTACHED TO


OVERHEAD CABINET / LED COVE LIGHT ABOVE
S

m MIRROR
S
S

WALL MOUNTED LED LIGHT FIXTURE


k j
(W/ MOTION SENSOR)

WALL SWITCH (1200mm height measured from center

S
k j
of plate to ffl)
m
3W

S
THREE-WAY SWITCH

CIRCUIT HOME RUN (numbers inside circle identify


1 circuits)

SHEET NOTES:
1. ALL LIGHTING SHALL BE LED

3
LEVEL 3 LIGHTING LAYOUT 2. LIGHTING FIXTURES SHALL BE SUPPLIED BY OWNER

1:75 M

CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.


LIGHTING LAYOUT
PROPOSED HOUSE EXTENSION (3-LEVEL) LEGEND

PRC NO. VALIDITY:


Lot 8, Block 2, Black Ash Street, Richview Subdivision,
Bakakeng, Baguio City, Philippines
JUSTINE & JOYCE D. CALDERON
31 Unit G. Agno Street, Quezon City, Metro Manila
E-102
PTR NO. DATE:
PLACE: TIN:
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR BLDG PERMIT APPLICATION
600mm
above ffl gfci

REF MIC 5 RAN

1200 mm gfci gfci


above ffl
12
600mm 10 11
above ffl
WP
WP

4 8
gfci MIC
gfci
9
REF
ceiling
7
mounted gfci
WH 1200 mm
above ffl

1
LEVEL 1 POWER LAYOUT 2
LEVEL 2 POWER LAYOUT
1:75 M 1:75 M

WH
13 14 ceiling
WH
ceiling mounted LEGEND:
mounted
LPP LIGHTING & POWER PANELBOARD (locate inside kitchen overhead
cabinet)
6 gfci
DUPLEX CONVENIENCE OUTLET (450 mm from FFL unless noted otherwise)

gfci DUPLEX CONVENIENCE OUTLET INSIDE CABINET

gfci DUPLEX CONVENIENCE OUTLET (w/ Ground Fault Circuit Interruptor)

WP WEATHER PROOF CONVENIENCE OUTLET

1200 mm WH WATER HEATER OUTLET (ceiling mounted)


above ffl 1200 mm
MIC MICROWAVE OUTLET (energy star rated)
above ffl
REF REFRIGERATOR OUTLET (energy star rated)
RAN ELECTRIC STOVE OUTLET (for 2 burner induction)
M HOUSE METER (BENECO supplied)

RG-6 CABLE TV OUTLET (conceal behind tv)

3
LEVEL 3 POWER LAYOUT SHEET NOTES:
1:75 M 1. USE GFCI POWER OUTLETS AT WET AREAS SUCH AS ABOVE KITCHEN COUNTERTOP,
TOILETS & GARAGE
2. ALL POWER OUTLETS SHALL HAVE GROUNDING WIRE

CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.


POWER LAYOUT
PROPOSED HOUSE EXTENSION (3-LEVEL) LEGEND

PRC NO. VALIDITY:


Lot 8, Block 2, Black Ash Street, Richview Subdivision,
Bakakeng, Baguio City, Philippines
JUSTINE & JOYCE D. CALDERON
31 Unit G. Agno Street, Quezon City, Metro Manila
E-103
PTR NO. DATE:
PLACE: TIN:
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR BLDG PERMIT APPLICATION
RT
H
FOOTING EXCAVATION CALCULATION (5 footings):

EX-101
2600

2
F1/F2
2.5m WIDTH X 2.5m LENGTH X 2.3m DEPTH
= 14.37 cu.m. X 4 = 57.48 CU.M (volume #3a)

F3
1.6m WIDTH x 1.6m LENGTH x 2.3m DEPTH
=5.88 cu.m (volume #3b)
5873

EXCAVATION VOLUME SUMMARY:

VACANT LOT
EXISTING 2 LEVEL
HOUSE TO REMAIN Volume #1 = 24.92 cu.m.
Volume #2 = 207.56 cu.m.
EL=7.38 m Volume #3 = 63.36 cu.m.
TOTAL= 295.84 cu.m.
PL
VACANT LOT (FUTURE PLAYGROUND)

MAIN ENTRY
1700

3150

3150
1450

EL=6.82 m

24 32

400

2350
3250

3250
20 PATIO EL=4.47 m

400
PL

1600
900 DIAGONAL HATCH
PLANTERS INDICATES
1600

EL=2.80 m
12 EXTENT OF AREA

1400
PLANTERS EL=1.47 m TO BE
EXCAVATED
10
SITE SECTION area=20.47m

1471
ELEVATED PLANTBOX 2
4409

width=10.14m
EL=1.40 m
1:100 M Volume #2 =207.56 cu.m.
PARKING SPACE
4829

FOR 2 VEHICLES area=17.8m


height=1.4m
1 Volume #1 = 24.92 cu.m.
1257
1357

SIDEWALK
EL=0.00 m
EXISTING

1650 10144 EXTENT OF EXCAVATION LIMIT


142
1
EXCAVATION PLAN
T
BLACK A SH STREE 1:100 M

CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.


EXCAVATION SITE PLAN
PROPOSED HOUSE EXTENSION (3-LEVEL) EXCAVATION SITE SECTION
ENGR. MARK DE GUZMAN
PRC NO. 73948
MSCE, PhDCE
VALIDITY: May 28, 2020
Lot 8, Block 2, Black Ash Street, Richview Subdivision,
Bakakeng, Baguio City, Philippines
JUSTINE & JOYCE D. CALDERON
31 Unit G. Agno Street, Quezon City, Metro Manila
VOLUME COMPUTATION EX-101
PTR NO. 3440907 DATE: Jan 3, 2018
PLACE: Baguio City TIN: 182-874-888
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR CONSTRUCTION
GENERAL NOTES: PROJECT SPECIFICATIONS WATER TEST ON SYSTEM
- Upon completion of the rough-in and before
1. All plumbing works included herein shall be
connecting fixtures, the entire cold water piping
executed according to the provisions of the COLD / HOT WATER LINES
Uniform Plumbing Code of the Philippines, the -shall be polypropylene pipes & fittings, PN-20 system shall be tested at a hydrostatic pressure 1 21
National Plumbing Code, rules and the minimum rating. Jointing shall be by socket fusion. times the expected working pressure in the system
regulations of the concerned city. "Vespo", "Neltex", "Atlanta" or approved equal. during operation and shall remain tight and leak
2. Coordinate the drawing with other related proof.
drawings and specifications. the engineer shall SEWER AND WASTE, STORM DRAIN,
be notified immediately of any discrepancy found DOWNSPOUTS & VENT PIPES DEFECTIVE WORK
therein. -"Neltex" or "Emerald" PVC series 1000. Fittings shall - All defective work, materials replaced and tested
3. All pipes shall be installed as indicated on be pvc w/ solvent cement. will be repeated until satisfactory performance is
plans. any relocations required for proper attained. Caulking of screwed joints or holes will not
execution of other trades shall be with prior WATER METER- "Nibco", "Kitz", "Amico" , "Arad" or be permitted.
approval of the architect/ engineer. approved equal
4. Proposed sanitary utilities shall conform to the DISINFECTION
actual location, depth and inlet elevation of all GATE VALVES- "Kitz" or approved equal -The entire water distribution system shall be
existing pipes and structures as verified by the thoroughly flushed and treated with Chlorine before it
builder. IDENTIFICATION & APPROVAL OF MATERIALS is operated for human use. Disinfection shall be liquid
5. All slopes for horizontal drainage shall -Each length of pipe, fittings, traps, fixtures and Chlorine or hypochlorite and shall be introduced in a
maintain 1% unless otherwise specified. device used in the Plumbing system shall have cast, manner approved as practiced for water distribution
6. Size of water supply pipes to fixtures shall be tamped or marked on it, the manufacturer's trade system.
in accordance with the manufacturer's mark or name, weight, type and classes of product After contact period of not less than 16 hours, the
instructions. when so required by the standard. heavily chlorinated water shall be flushed from the
7. The builder shall verify locations of all existing system with potable water.
utilities at site. He shall coordinate the sewer PITCH
line effluent disposal and water line service -All sewer and drainage pipes shall be pitched 6mm SHEET INDEX
connecting points. per 300mm. but in no case flatter than 3mm per P-101 GENERAL NOTES, DETAILS,
8. All pipe sizes are in millimeters and all 300mm. LEGENDS, SPECIFICATIONS,
dimensions are in meters unless otherwise
specified. ROUGHING IN P-102
SYMBOLS & ABBREVIATIONS
LEVEL 1 PLUMBING LAYOUT,
1
SEPTIC TANK DETAILS
9. All pipe diameter are inside dimension - Roughing-in for pipes and fixtures shall be carried ISOMETRIC VIEW NTS
(nominal) unless otherwise specified. along with the building construction. Correctly P-103 LEVEL 2, LEVEL 3 & ROOF
10. Verify architectural plans for the exact located openings of proper sizes shall be provided PLUMBING LAYOUT
location or setting out of floor drains & floor clean where required in the walls and floors for the
outs. passage of pipes. All items to be embedded in LEGEND, SYMBOLS &
11. All concealed valves or valves at ceiling level concrete shall be thoroughly clean and free from all
shall be provided with access manhole. rust, scale and paint. ABBREVIATIONS
12. Risers and stacks shall be provided with
sway braces every other floor starting at ground CLEANOUTS WATER DISTRIBUTION SYSTEM
floor. -shall be of the same size of the pipe, the location of CWL COLD WATER LINE
13. Upon completion of the water supply system which is extended to an easily accessible place. CWDF COLD WATER DOWN FEED
CWR COLD WATER RISER
or portions of the system and before piping is GV GATE VALVE
covered up, it shall be hydrostatically tested with TRAP M WM WATER METER
-every plumbing fixture of equipment requiring CV CHECK VALVE
potable water at one and a half (1 21) times the HB HOSE BIBB
expected working pressure in the system. connections to the drainage system shall be
14. Required fittings not shown on the plans equipped with a trap. Each trap shall be placed as
WASTE, SEWER AND VENT SYSTEM
shall be provided. near as possible to the fixture. No fixture shall be
15. All fixtures shall be vented unless otherwise double trapped. SP/ WP SOIL PIPE/ WASTE PIPE
VAC VENT AT CEILING
noted. FCO FLOOR CLEAN OUT
16. All vents passing thru roof shall be provided PIPE HANGER INSERTS and SUPPORTS VS VENT STACK
- Horizontal runs of pipe shall be hung with SS SOIL STACK
with metal flashing and anchorage FD FLOOR DRAIN
17. Plumbing drawings are essentially adjustable wrought iron or malleable pipe hangers VSTR VENT STACK THRU ROOF
diagrammatic to the extent that many offset, spaced not over 3m apart. Wrought iron clamps shall AAV AIR ADMITTANCE VALVE

bends, elbows, special fittings and exact be used to support vertical pipe runs or collars
locations of equipment, piping and related spaced not more than 9m apart.
STORM DRAINAGE SYSTEM
accessories are not indicated. the builder shall
carefully study the drawings and actual field DRAINAGE SYSTEM TEST DP DRAIN PIPE
DS DOWNSPOUT
conditions to determine the best method, exact -The entire drainage and venting system shall have
location, routing, obstructions, other trades etc all the necessary openings which can be plugged to ADCB AREA DRAIN / CATCH BASIN

which affect the installation of his work. permit the entire system to be filled with water to the
18. Provide air chamber to all quick closing level of the highest stack vent above the roof. The
valves system shall hold the water for a full 30 min during
which time there shall be no drop greater than 10mm. 2
CATCH BASIN DETAILS
NTS
CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.
GENERAL NOTES, SPECIFICATIONS
PROPOSED HOUSE EXTENSION (3-LEVEL) LEGENDS, SYMBOLS & ABBREVIATIONS, DETAILS

PRC NO. VALIDITY:


Lot 8, Block 2, Black Ash Street, Richview Subdivision,
Bakakeng, Baguio City, Philippines
JUSTINE & JOYCE D. CALDERON
31 Unit G. Agno Street, Quezon City, Metro Manila
P-101
PTR NO. DATE:
PLACE: TIN:
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR BLDG PERMIT APPLICATION
ADCB

15
SHO 0Ø
DP
ELEVATED
WATER
C
VA TANK
Ø
50 ADCB

FD VTR
FC
O WC

50Ø VAC SHO

10
0Ø 20Ø CWR
SP

50Ø VS
20 FCO
Ø
CW
L WC
20Ø RISER RISER TO embed water supply line in FD
WATER TANK concrete SLAB.
Typical. LAV
FCO DS
SS
O
ADCB FC

25Ø CWL RISER

150Ø DS

25Ø CWL RISER


AAV

100Ø SP

100Ø SS
20 50
Ø Ø
FC CW VA

20Ø CWL
O L C
2% slab FC
75 O
slope Ø LAV
SP

50Ø VAC WP
O 75Ø

150Ø DP
25Ø CWL FC 10
0 Ø
100Ø SP SP
FCO
WC WC
100Ø SP

100Ø SP
20Ø CWL

LAV
20Ø CWL
20Ø CWL LAV
FD FCO SHO C
SEPTIC VA
Ø
TANK 50 10
(see detail 0 Ø
SP
DS at P-101) O
CB
FC FC
O
LAV
2% slab
slope SP WC

HOSE BIBB 10 ADCB
O FD 10 L
ADCB FC 20 C 0Ø CW
Ø
CW VA SP
20
Ø SP
50
Ø 0Ø
100Ø DP

CHECK VALVE L 10
150Ø DP
100Ø SP

LAV
SP DP
WATER METER 0Ø 0Ø
10 15
M O 20Ø
GATE VALVE FC CWL

L
CONNECT TO CW
Ø
CONNECT TO BAWADI WATER R 25
EXISTING LINE BE K
H AM TAN
DRAINAGE LINE 3-C TIC
P
SE

ADCB
CONNECT TO
EXISTING

M
DRAINAGE LINE
INE
EL
AG
AIN
DR IN
ING MA
IST
ISOMETRIC LAYOUT
R

1
LEVEL 1 PLUMBING LAYOUT NNE
CT
T O
EX

CW
FR
OM
WA
TE

2
1:75 M CO
25
Ø NTS

CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.


LEVEL 1 PLUMBING PLAN
PROPOSED HOUSE EXTENSION (3-LEVEL) ISOMETRIC PLAN

PRC NO. VALIDITY:


Lot 8, Block 2, Black Ash Street, Richview Subdivision,
Bakakeng, Baguio City, Philippines
JUSTINE & JOYCE D. CALDERON
31 Unit G. Agno Street, Quezon City, Metro Manila
P-102
PTR NO. DATE:
PLACE: TIN:
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR BLDG PERMIT APPLICATION
ELEVATED
WATER
TANK FLOAT VALVE
2% slope
to drain 20Ø CWL

ADCB ADCB
150Ø DP

150Ø
DP
20Ø CWL 20Ø RISER TO
WATER TANK
VTR 150ØDS

1%
n
ai
dr

sl
op
to

e
e
op

to
sl

dr
200mm high CHB curb

200mm high CHB curb


1%

ai
n
1% slope to drain
1% min
slope

1% min

ROOF LEVEL PLUMBING LAYOUT


slope

3
1:75 M

existing septic
tank to remain CHB curb
200mm high
1% min
slope

100Ø SS
(relocate
existing)
10
(re


loc

DP
ate

50Ø VAC 20Ø CWL 50Ø VAC 20Ø CWR


20Ø CWR
d)

20Ø CWL

DS CCO SS DS SS
CCO 100Ø SP DS
FD (relocate

75Ø WP
SHO
existing)
100Ø

WC
SP

20Ø CWL LAV WC


WC
75Ø WP
50Ø VAC FCO
(above slab)
CCO 100Ø SP (under slab/ inside drop ceiling) LAV FCO FCO 1%
slope
LAV
20Ø CWL (embedded in slab)

100Ø DP

2
LEVEL 3 PLUMBING LAYOUT 1
LEVEL 2 PLUMBING LAYOUT
1:75 M 1:75 M
CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.
LEVEL 2, LEVEL 3 & ROOF LEVEL PLUMBING PLAN
PROPOSED HOUSE EXTENSION (3-LEVEL)
PRC NO. VALIDITY:
Lot 8, Block 2, Black Ash Street, Richview Subdivision,
Bakakeng, Baguio City, Philippines
JUSTINE & JOYCE D. CALDERON
31 Unit G. Agno Street, Quezon City, Metro Manila
P-103
PTR NO. DATE:
PLACE: TIN:
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR BLDG PERMIT APPLICATION
GENERAL NOTES: Stripping schedule of forms and shores:
1. Foundation & slab on grade 24 hours
1. In the interpretation of these drawings, indicated dimensions 2. Suspended slab 8 days
shall govern and distances or sizes shall not be scaled for 3. Concrete walls 18 hours
construction purposes. 4. Beams 14 days
2. The contractor shall coordinate with the architect, structural
engineer, sanitary engineer, electrical engineer and other REINFORCING STEEL BARS:
consultants and trades for the exact size, number, dimensions and All reinforcing bars shall conform to ASTM a615 grade 33 for DIA
location of sleeves or openings thru floor slabs, beams and walls. 12 and smaller bars and grade 40 for diameter 16 and larger bars.
3. All slabs, beams, girders and other structural elements which Steel reinforcing bars to be used for this project shall consist of
are not indicated, detailed, designated or inadvertently omitted but standard deformed structural bars meeting ASTM specifications.
are necessary shall be coordinated with architectural and other The steel reinforcements for concrete shall be formed accurately
allied engineering plans to complete the structural works in according to the sizes of the columns, beams, footings, slabs etc. LENGTH OF LAP COMPRESSION SPLICES (mm)
accordance with the intent of the plans and specifications . where they are to be used. They shall be tied together at each bar BAR SIZE (mm) f'c = 21.0 MPa (3000 psi) f'c = 28.0 MPa (4000 psi) f'c = 34.5.0 MPa (5000 psi)
4. It is the contractors responsibility to provide adequate shoring intersection with Gauge No. 16 wire or by welding. CHB
16 420 390 360 WALL
and bracing for the existing and proposed structures to counter No steel reinforcement should be installed unless it is free from
any imposed loads during construction. 20 540 510 450
rust, scale or other coating which would destroy or reduce the
25 720 600 540
bond with concrete. The reinforcement bars must be positioned CONT. L-SHAPED DOWEL

400
28 810 720 690
STRUCT'L SPECIFICATIONS: such that there is space between the steel at the sides and bottom
of the forms. 32 900 780 720
ALTERNATELY INSTALLED
TO MATCH CHB
EROSION CONTROL AND PROTECTION 36 990 900 810 HORIZONTAL BARS
MINIMUM CONCRETE COVER FOR REINFORCING BARS:
Avoid erosion, contamination, and sedimentation of the site,
1. Unprotected by membrane on ground or external surfaces: 40
surrounding areas, and drainage systems. Ensure that washout SCHEDULE OF CONCRETE HOLLOW BLOCK REINFORCEMENT CONCRETE
mm.
does not enter waterways or stormwater drains. Ensure that there POST
2. Protected by membrane on ground: 30 mm. BLOCK REINFORCEMENT
are no cross connections between stormwater systems and NOTE
3. Internal surfaces: 20 mm. THK (mm) HORIZONTAL VERTICAL
sewerage systems.
4. Footings: 50 mm 400

400
Keep earthworks and the site of the works free of excess water. 100 10 mm Ø @ 600mm o.c. 10 mm Ø @ 600mm o.c. A. MINIMUM LAP SPLICE=GREATER OF 30 BAR DIAMETERS OR 400mm
5. Aggressive soil or salty environment: 65 mm. B. PROVIDE 1-16 mm Ø VERTICAL BAR @ CORNERS, INTERSECTIONS,
Provide and maintain slopes, crowns, drains, excavations and
150 10 mm Ø @ 600mm o.c. 10 mm Ø @ 600mm o.c. END OF WALLS AND EACH SIDE OF OPENING *FOR SIZE AND SPACING OF
embankments to ensure free drainage. Place construction,
CAMBER REQUIREMENTS: HOR & VERT. BARS, SEE
including fill, masonry, concrete and services, on ground from C. WHERE CHB WALLS ADJOIN COLUMNS, RC BEAMS & WALLS, SCHEDULE OF CONCRETE
Unless otherwise noted on the plans or specifications, camber all
which free water has been removed. Prevent water flow over 200 10 mm Ø @ 600mm o.c. 10 mm Ø @ 600mm o.c. DOWELS SHALL MATCH CHB REINFORCEMENT. HOLLOW BLOCK
rc beams at least 10mm for every 4000mm of clear span except
freshly laid work. D. LINTEL BEAMS SHALL BEAR AT LEAST 400mm ON EACH SIDE OF REINFORECEMENT
for cantilever beams which shall be 50mm for every 3000mm of
clear span. MASONRY WALL OPENING
EXCAVATION
Unless otherwise noted in plans or specifications, camber all RC
Site surface: Excavate to give the levels and profiles required for
construction, site services, paving, and landscaping. Allow for
slabs 8mm per 3000mm of shorter span and 14mm for every INTERSECTION WALL
2000mm of cantilever slabs.
compaction or settlement or heaving.
FOUNDATION NOTES
Footings: Excavate for footings to the required sizes and depths.
Provide temporary removal of water from any source during
Confirm that the foundation conditions meet the design bearing
construction.

DOWEL

DOWEL
capacity. CONT. L-SHAPED DOWEL
Dewatering shall be carefully and properly performed to avoid

400

400
Foundations: After excavation, confirm that the bearing capacity is TO MATCH CHB
disturbing the foundations and slab bearing surfaces. 2-12Ø TOP BARS
adequate. 1 HORIZONTAL BARS
Contractor shall design, install and monitor excavations, retention 10 Ø STIRRUPS 1-12 Ø

200

200
Bearing surfaces: Provide even plane bearing surfaces for
systems as required for protection of adjacent properties and @ 150 O.C.
loadbearing elements including footings. Step to accommodate 1-12 Ø
CONCRETE
provide all measures and precautions necessary to minimize 2-12Ø BOT BARS
level changes. Make the steps to the appropriate courses if 150 100 POST
settlement and prevent damage to adjacent existing or new
supporting masonry.
construction.
Grading external areas: Grade to give falls away from buildings,
Prepare conditions of concrete supply and placement of the SECTION 400

400
minimum 2%. Grade the ground surface under suspended floors 1 10 mm Ø
complete foundation for the full thickness as a continuous
and externally to drain ground or surface water away from STIRRUPS @
monolithic casting. 150mm O.C. *FOR SIZE AND SPACING OF
buildings without ponding. HOR & VERT. BARS, SEE
CHB
CONCRETE HOLLOW BLOCKS (CHB) SCHEDULE OF CONCRETE
FILL CHB WALL CHB WALL WALL
HOLLOW BLOCK
All materials and workmanship shall be in accordance with the
Place fill in near horizontal layers of uniform thickness no greater REINFORECEMENT
applicable standards and specifications of the National Concrete
than 200 mm after compaction, deposited systematically across 1-16 mm Ø BAR
OPENING
Masonry Association and Uniform Building Code.
the fill area. Compact each layer to achieve the required density.
All masonry walls shall be reinforced according to the following CHB WALL
Maximum depth of sand fill: 400 mm.
schedule of concrete hollow block reinforcement unless otherwise CORNER WALL DETAIL
indicated on the plans.
CONCRETE MIXES AND PLACING:
All cells containing reinforcing bars or inserts shall be completely POURED
Unless otherwise indicated in plans or noted in the specifications, 1-16 Ø
filled with concrete grout. CONCRETE
VERT BARS
the minimum 28 days cylinder compressive strength shall be as
provide 1-10Ø extra vertical bars at corners, intersections, end of DOOR (TYPICAL)
follows:
walls and each side of openings. JAMB CONCRETE
1. Foundation 24.0 mpa. (3500 psi) FFL POST CHB
All CHB shall be laid plumb, true to line, with level and accurately WALL
2. Columns 24.0 mpa. (3500 psi)
spaced courses, and shall reveal corners plumb and true with
3. Floor slabs & beams 24.0 mpa. (3500 psi) 400 400
4. Slab on grade 17.0 mpa. (2500 psi)
each course’s breaking joints halfway with the course
below. Units shall be dampened before laying; joints shall
DETAIL ELEVATION
Concrete shall be deposited in it's final position without
be 3/8” mortar. The mortar on both horizontal and vertical joints
segregation, re-handling or flowing, placing shall be done
shall be battered on the blocks at the time of laying and not
preferably with buggies, buckets or wheel barrows. No chutes will
be allowed except to transfer concrete from hoppers to buggies,
flushed or grouted in place. TYPICAL DETAIL OF 100mm & 150mm LINTEL
wheel barrows or buckets in which case they shall not exceed six BEAMS OVER DOORS, WINDOWS & OPENINGS TYPICAL CONNECTION
meters in aggregate length.
No depositing of concrete shall be allowed without the use of OF CHB & R.C.
vibrators unless authorized in writing by the structural engineer
and only for unusual conditions where vibration is extremely
difficult to accomplish.
All concrete shall be kept moist for a minimum of seven (7)
consecutive days immediately after pouring by the use of wet 1
TYPICAL DETAILS
burlap, fog spraying, curing compounds or other approved NTS
methods.
CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.
GENERAL NOTES, SPECIFICATIONS
PROPOSED HOUSE EXTENSION (3-LEVEL) BUILDING SECTION
ENGR. MARK DE GUZMAN
PRC NO. 73948
MSCE, PhDCE
VALIDITY: May 28, 2020
Lot 8, Block 2, Black Ash Street, Richview Subdivision,
Bakakeng, Baguio City, Philippines
JUSTINE & JOYCE D. CALDERON
31 Unit G. Agno Street, Quezon City, Metro Manila
TYPICAL STRUCTURAL DETAILS S-101
PTR NO. 3440907 DATE: Jan 3, 2018
PLACE: Baguio City TIN: 182-874-888
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR CONSTRUCTION
1 2 3 1 2 3
3000 6000 ±3002 3000 6000 ±3002

UPDATE EXISTING STAIRS


1050 1450 1450 1050 1000 1850
C1 C1 C1a C2 C2 C2a
C B-1 B-1 B-1 C
GB GB GB

UPDATE EXISTING STAIRS


1600
975
2500

2500
F3

2900
1600
GB (ground beam) F2 F2 CS1

BB1

6075
GB

6075
S1

BB1
CS1
SOG-1 SOG-1 SFL=2.52 750 1100

SOG-1 SFL=2.70

2625
SFL=0.05

1450
B B
1450

650 600250
300

EXISTING STAIRS
300
450 450

GB BB1 C3

600
UPDATE
600
C3 400

1050
400
400
400
A CS1 A
C1 F1 C1
1050

1450 1050 200


F1 200 800

±3145
±3145
1050 1450 2
LEVEL 2 FRAMING PLAN
1:75 M
2500 2500 1600

75

75

75
60
0
TY
P.

1600
FOUNDATION PLAN

2500

2500
1 75
1:75 M

ENLARGED PLAN OF F3
75 75 THICKNESS=0.40m
C1 C2 C3 C1a C2a Reinforcement=
9 pcs 16Ø bothways
300

300
450
400

400

ENLARGED PLAN OF F1 ENLARGED PLAN OF F2


THICKNESS=0.40m THICKNESS=0.50m
400 400
COLUMN 400 300 400 Reinforcement=13 pcs 20Ø bothways Reinforcement=28 pcs 20Ø bothways

4
SCHEDULE 12-20Ø Main Bar; 10-20Ø Main Bar; 10-20Ø Main Bar; 12-16Ø Main Bar; 10-16Ø Main Bar;
10Ø Ties at 7-75 mm; 10Ø Ties at 7-75 mm; 10Ø Ties at 7-75 mm; 10Ø Ties at 7-75 mm; 10Ø Ties at 7-75 mm; FOOTING SCHEDULE
1:30 M Rest @ 100 mm Rest @ 100 mm Rest @ 100 mm Rest @ 100 mm Rest @ 100 mm 3
1:40 M
CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.
FOUNDATION PLAN, LEVEL 2 FRAMING PLAN
PROPOSED HOUSE EXTENSION (3-LEVEL) FOOTING SCHEDULE, COLUMN SCHEDULE
ENGR. MARK DE GUZMAN
PRC NO. 73948
MSCE, PhDCE
VALIDITY: May 28, 2020
Lot 8, Block 2, Black Ash Street, Richview Subdivision,
Bakakeng, Baguio City, Philippines
JUSTINE & JOYCE D. CALDERON
31 Unit G. Agno Street, Quezon City, Metro Manila
S-102
PTR NO. 3440907 DATE: Jan 3, 2018
PLACE: Baguio City TIN: 182-874-888
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR CONSTRUCTION
1 2 3 1 2 3

S-104
3
3000 6000 ±3002 3000 6000 ±3002

1000 700 3225 2076 950 1650


950
C2 C2 C2a
B-1 B-1 B-1 C B-1 C

950
CONCRETE STAIRS

BB-1

BB-2
6075

6075
S1
BB-1

BB-2
CS1 S1 CS1 CS1 CS1

B B
BB-1 BB-2

480

480
C3

600

600
C1
CS1 A CS1 A
650

750 200

120

120
1365
1650 750 200
200 800

±3145

±3145
1
LEVEL 3 FRAMING PLAN 2
ROOF SLAB FRAMING PLAN
1:75 M 1:75 M

BB-1 (BAND BEAM) BB-2 BOTTOM BAR


LENGTH / 3 LENGTH / 3 TAG SLAB THICKNESS MAIN REINF.
REINFORCEMENTS
REMARKS
D

450 450
S1 200 mm 12Ø @ 125mm B.W. NA on steel deck
SE

HEIGHT
200

200

SOG 100 mm 12Ø @ 600mm B.W. NA slab on grade


U

AT SUPPORTS & MIDSPAN AT SUPPORTS & MIDSPAN


7 pcs-16Ø continuous top bars 5 pcs-16Ø continuous top bars
T

7 pcs-16Ø continuous bot bars 5 pcs-16Ø continuous bot bars


L/5 L/5 ANCHOR
O

TAG SLAB THICKNESS MAIN REINF. TEMP REINF. REMARKS


Use 10Ø stirrups spaced @ Use 10Ø stirrups spaced @ LENGTH (CLEAR SPAN) LENGTH
N

75mm on center 75mm on center


CS1 200 mm 12Ø @ 125mm 12Ø @ 250mm 500mm on steel deck
B-1 GB (GROUND BEAM)
300 300 400 400

SLAB SCHEDULE
450

450

400

400
4
NTS
BEAM AT SUPPORTS
5-16mm cont. top bars
AT MIDSPAN
3-16mm cont. top bars
AT SUPPORTS
5-16mm cont. top bars
AT MIDSPAN
3-16mm cont. top bars

3
SCHEDULE 3-16mm cont. bot bars 5-16mm cont. bot bars

Use 10Ø stirrups. 1 spaced @ 75mm, rest @ 175mm


3-16mm cont. bot bars 5-16mm cont. bot bars

Use 10Ø stirrups. 1 spaced @ 75mm, rest @ 175mm


1:30 M

CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.


LEVEL 3 FRAMING PLAN, ROOF SLAB FRAMING PLAN
PROPOSED HOUSE EXTENSION (3-LEVEL) SLAB SCHEDULE, BEAM SCHEDULE
ENGR. MARK DE GUZMAN
PRC NO. 73948
MSCE, PhDCE
VALIDITY: May 28, 2020
Lot 8, Block 2, Black Ash Street, Richview Subdivision,
Bakakeng, Baguio City, Philippines
JUSTINE & JOYCE D. CALDERON
31 Unit G. Agno Street, Quezon City, Metro Manila
S-103
PTR NO. 3440907 DATE: Jan 3, 2018
PLACE: Baguio City TIN: 182-874-888
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR CONSTRUCTION
C B A

BLDG LINE OF EXISTING 2 STOREY


±3230
verify site
ROOF LEVEL

200
USE 2 LAYERS 5" CHB LAID FFL=8.10 m
ALTERNATELY W/ 10Ø HOR
& VERT REBAR SPACED @ 25
400mm O.C.
M2 PANEL,
NON-LOAD

2700
NEARING

276
EXISTING WALL TO BE
REMOVED
MASTERS BEDROOM LEVEL 3

200
FFL=5.40 m

COMPACTED FILL

2700
8100
300
PROPOSED OUTLINE OF
'STEPPED' EXCAVATION.
GENERAL CONTRACTOR
TO SUBMIT EXCAVATION LIVING
METHODOLOGY FOR STO KITCHEN ROOM
SFL LEVEL 2
OWNERS & ENGINEER'S

200
FFL=2.70 m
APPROVAL
150

OUTLINE OF EXISTING
2 LAYERS CONTINUOUS 'STEPPED' RETAINING
HORIZONTAL AND WALL TO BE REMOVED

2700
VERTICAL REBAR

1
10 MIL MOISTURE BARRIER,
FULL HEIGHT OF S-104
400
RETAINING WALL LEVEL 1
ENTRY
SFL ACCESSIBLE SUITE top of sidewalk
0.00 m
OUTLINE OF GRADE

1500 TYPICAL

1500 TYPICAL
100
2 LAYERS: BEAM
HORIZONTAL REBAR=12Ø @ 150mm O.C. (2 layers)
OUTLINE OF COLUMN
VERTICAL REBAR= 12Ø @ 100mm O.C. (2 layers)
BEYOND

COLUMN FOOTING
(SEE FOOTING SCHEDULE)

TYPICAL RETAINING
1
WALL ELEVATION DETAIL 2
STRUCTURAL SECTION
1:50 M 1:50 M
CONSULTANT PROJECT NAME OWNER SHEET CONTENTS SHEET NO.
ENLARGED STRUCTURAL SECTION
PROPOSED HOUSE EXTENSION (3-LEVEL)
ENGR. MARK DE GUZMAN
PRC NO. 73948
MSCE, PhDCE
VALIDITY: May 28, 2020
Lot 8, Block 2, Black Ash Street, Richview Subdivision,
Bakakeng, Baguio City, Philippines
JUSTINE & JOYCE D. CALDERON
31 Unit G. Agno Street, Quezon City, Metro Manila
S-104
PTR NO. 3440907 DATE: Jan 3, 2018
PLACE: Baguio City TIN: 182-874-888
COPYRIGHT RESERVED. THIS PLAN AND DESIGN ARE, AND AT ALL TIMES REMAIN THE EXCLUSIVE PROPERTY OF THE
ARCHITECT OF RECORD AND CANNOT BE USED OR REPRODUCED WITHOUT THE ARCHITECT'S WRITTEN CONSENT. ISSUED FOR CONSTRUCTION

Вам также может понравиться