Trombe wall

Trombe walls use a combination of thermal mass and glazing to collect and store solar radiation so that it
can be used to heat buildings. The broad idea was patented by Edward Morse in 1881, but it was named
after French engineer Felix Trombe, who along with architectJacques Michel used trombe walls as an
architectural component in the 1960’s.

A thermally massive wall with good solar absorption characteristics (perhaps with a matt, dark-coloured
surface) is orientated facing towards the direction of the sun. The wall is constructed behind a
glazed façade that protects it from external conditions. There is generally a spacebetween
the glazing and the wall. This space can be very narrow, just sufficient to allow air movement between
the glazing and the wall and to provide access for cleaning, or it can be large enough to be habitable.

Solar radiation that penetrates through the glazing will heat up the wall, but the resulting emission of long-
wave infrared radiation from the wall will not re-transmit back through the glazing which is opaque to long-
wave infrared radiation. This creates an effect similar to that which allows greenhouses to trap solar
radiation.

Heat built up in the wall is slowly released into adjacent spaces by radiation and convection. Depending
on the thermal mass of the wall, this heat can be released over long periods of time,
moderating fluctuations in conditions. This is a form of ‘passive’ solar heating, as opposed to an
‘active’ building services heating system.
The design of trombe walls needs to enable them to provide solar heating during colder periods, but not
to generate overheating during warmer periods. This might require the use of external vents, shading or
overhanging eaves to limit peak gains and to enable night time cooling.

The design may also include vents at the top and bottom of the wall (which may be controllable or even
include mechanical assistance) to allow more rapid heat transfer between the wall and the
adjacent space, or it may rely entirely on conduction through the wall. Where vents are included, cooler
air from the adjacent space will enter through the lower vent, will be heated by the wall and so will rise,
and will then return to the adjacent space through the upper vent. Closing the vents at night will prevent
reverse flows occurring and removing heat from the space.

Typically the wall will be 20-40 cm thick, made out of high heat capacity materials such
as masonry or concrete (or even containers filled with water), with the absorbed heat taking up to 10
hours to conduct to the interior.

Installations can also include solar thermal systems to generate hot water.

The efficiency of trombe walls can be improved by the use of double glazing with a low-e coating to
reduce heat losses to the outside. Low-e coatings reduce the effective emissivity of the surface
of glass so that it reflects, rather than absorbs, a higher proportion of long-wave infra-red radiation.
Ideally, the glazing should have exterior insulation, shutters or blinds to prevent heat loss during the night.