TROOUBLE SHOOTING
Pre-Check
1. Check if power is supplied at Concent and Power Cord is connected properly before repair
2. Check by referring to the followings.

12-1) When power is not supplied

Start

Is Power of primery
DC -TRANS applied?

Check assembly of
wires and do
epairing
s Power of secondary
DC -TRANS applied?

Change DC-TRANS

Is 12V terminal normal?

Change PCB.
REG2/Change PCB

Is 5V terminal normal?

Change PCB.
REG1/Change PCB
Are wire connections of
PANEL PCB normal?

Do repairing

Ia PANEL PCBnormal?

Change PANEL PCB

Change MAIN PCB ASS'Y

44
TROOUBLE SHOOTING
12-2) When there is a trouble with Self Diagnosis

1) Ambient Sensor trouble → (applied to Ambient Sensor Temp type)

Start

Is Ambient Sensor
normal?
Change Ambient
Sensor

Is MAIN PCB (CN32)


insertion normal?

Connector contact
trouble/re-insertion
Is the connection wire between
MAIN PCB connector(CN32)and Temp Sensor normal
(upper part od door)?

Short between
connector Sensors
Is the voltage of both ends (0.5V>V Measured value)
of Ambient Sensor of MAIN PCB
Connector (CN32)normal?

Change Sensor

Is MICOM Pin#57 input (0.5V>V Measured value >4.5V)


voltage normal?

Check soldering
fault,short,
Lead Touch
Change PCB

45
TROOUBLE SHOOTING
2) R-Room Temp Sensor trouble

Start

Is R-Room Temp
Sensor normal?

Change Temp
Sensor
Is the insertion of MAIN PCB
connector(CN30) normal?
Connector contact
trouble/re-insertion
Is the connection between
MAIN PCB connector(CN30) and Temp
Sensor(ORANGE) normal?
Short between
connector Sensors
Is MICOM Pin#59
input voltage normal?
Check soldering
fault,short, Lead Touch
Change MAIN PCB

3) F-Room Temp Sensor trouble

Start

Is F-Room Temp
Sensor normal?

Change Temp
Sensor
Is the insertion of MAIN PCB
connector(CN80) normal?
Connector contact
trouble/re-insertion
Is the connection between
MAIN PCB connector(CN80) and Temp
Sensor(yellow) normal?
Short between
connector Sensors
Is MICOM Pin#58
input voltage normal?
Check soldering
fault,short, Lead Touch
Change MAIN PCB

46
TROOUBLE SHOOTING
4) Defrost Sensor trouble

Start

Is Defrost Sensor
normal?

Change Defrost
Sensor
Is MAIN PCB (CN30)
insertion normal?
Connector contact
trouble/re-insertion
Is the connection wire
between MAIN PCB connector(CN30) and
Defrost Sensor (purple) normal?
Short between
connector Sensors
Is MICOM Pin#60
input voltage normal?
Check soldering fault,
short,Lead Touch
Change MAIN PCB

5) Damper error occurs

Start

Is Damper Heater
normal? (about 144ohm)

Change Damper
Is MAIN PCB Connector
(CN30) insertion normal?
Connector contact
trouble/re-insertion
Is MICOM Pin#54 input
voltage normal? (over 2V)

Normal connection

Is it conditionfor
Damper Off?
Make Damper Off
condition
Change MAIN PCB

47
TROOUBLE SHOOTING
12-3) When COMP does not operate

Pre-Check
1. If it doesnotpass5 min after a desired Temp reached, COMP does not operate.
2. During Defrost, COMP does not operate.
3. With the disconnected F-Sensor or R-Sensor, COMP does not operate because MAIN PCB
picks up theTemp as a desired level.

Start

Is ForcedOperation on?

Run Forced
Operation

Is theMICOM #24 output


"HIGH"(5V)?

Soldering checkout/
Change MICOM
orPCB
Is theIC05 #10
"LOW"?

Change or repair
IC05/Change PCB

Is COMP RELAY normal?

Change or repair
RELAY/Change PCB
Is contact of CONNECTOR
CN70 #9 contact normal

Insert Connector
completely/Check its
connection
Does COMP ASS'Y
Function normally?

Change/repair COMP

Check wire assembly/connection

48
TROOUBLE SHOOTING
12-4) When FAN & DAMPER does not operate

Note
"Check out the F-FAN with the Forced Operation selected"
1. F-FAN, R-Room DAMPER and COMP COOLING FAN remains off while COMP is turned off.
2. When Comp is ON, Damper does not always remain ON (including Forced Operaation) and
when R-Room temp reaches to set temp, Damper remains OFF.
3. When R-Room & F-Room get closeed after being opened, each Fan &Damper starts up
immediately. (Comp ON condition)

1) When F-Room FAN(F-FAN) does not operate

Start

Is it during
Forced Operation?

Start Forced Operation


Does Fan operate with
DOOR S/W presses?
Normal F-FAN
When using R600a Option
Is DOOR S/W normal?
Check Is insertion of
Connector CN31 of MAIN PCB Change DOOR S/W
normal?
Is insertion of
CN71(PURPLE) of MAIN PCB
Change Does voltage of normal?
PCB MICOMPIN #62,63 change? Re-insert ConnectorCN71
"0V, 5V"
MICOM #61 :F-DOOR Is voltage of MICOM
#63 :R-DOOR Pin #28 "HIGH"(5V)?

Check soldering / Change PCB NO


Is IC05 #14 "LOW"?

Check soldering / Change PCB

Is FANRELAY normal?

Check RELAY / Change PCB


Is insertion of
CN71(BLUE)of MAIN PCB
normal?
Re-insert ConnectorCN71

Is FANASS'Y normal?

Change or repair FAN


Check wire assembly & connection status

49
TROOUBLE SHOOTING
2) When R-Room DAMPER does not operate

Start

Is DAMPER in
operating conditions?
Forced Operation/
Temp Increase
When using R600a Option Does DAMPER
operates with DOOR S/W
Is insertion of pressed?
Check CN31 of MAIN PCB DAMPER is
Connector normal? normal
Is DOOR S/W normal?
Change Does voltage of Change DOOR
PCB MICOMPIN #62,63 change? S/W
"0V, 5V"
Is insertion of CN90 of
MICOM #61 :F-DOOR MAIN PCB normal?
#63 :R-DOOR Check Connector
CN90 again
Are voltage of MICOM
Pin #43,44,45 outputed?
Check soldering/
Change PCB
Is DAMPER normal?

Change DAMPER
Check wire assembly and connections between Dampers

50
TROOUBLE SHOOTING
3) When COMP COOLING FAN does not operate

Start

Is COMP operating?

Operate Forced
Operation
Is itCOMP COOLING FAN
ON condition?
Stand by or FAN ON
condition Confirm FAN
operating condition

Ambient Temp Range Load Operation Status


Comp Fan operates
Higher than 18 ℃
immediately upon COMP ON
Comp
Fan Between 13℃and 17 ℃ Comp Fan operates in 5 min
DELAY after COMP ON
Comp Fan gets off regardless
Lower than 12 ℃ of COMP

Is MICOM Pin #26


"HIGH"(5V)?
Check soldering /
Change PCB
Is IC3 #12
"LOW"?
Check soldering /
Change PCB
Is RELAY(RY73)
normal?
Check Relay /
Change PCB
Is contact of Connector
CN70(YELLOW)normal?
Check contact of
Connector CN70 again
Check wire assembled status of FAN MOTOR

51
TROOUBLE SHOOTING
12-5) When Defrost does not operate
Pre-Check
1. With a shorted-out Defrost Sensor, the fridge operates normally excepting Defrost(The fault
can be picked up with self-diagnosis, POWER ON/OFF).
2. There will be Heating trouble with a shorted-out Temp FUSE, which contributes to Defrost
by natural Temp increase resulting in a Temp Control problem stemmed from the increased
COMP OFF time.
3. When Defrost Sensor is faulty as OPEN, Heating will not be terminated, and COMP will
remain off following the Temp FUSE short-off.(The fault can be picked up with
self-diagnosis, POWER ON/OFF)

Start

Dose Defrost work upon


Forced Defrost KEY pushed?

Is concerned Defrost Sensor


Temp higher than 12 ℃?
Is power supplied to
Defrost Heater?
Maintain Forced Operation
for a certain time
Is MICOM #25
"HIGH"(5V)?
Check soldering,
Change PCB
Is output #11 of IC05
low?
Check IC3 /
Change PCB
Is Defrost Heater
Relay (RY72) normal?
COMMON RELAY RY71 Check RELAY /
Defrost Heater RY72 Change PCB

Is contact of Connector
N70(browwn) normal?
Check contact of
Connector CN70 again
Is Temp FUSE in EVAP.
normal?
Change Temp FUSE
Is Defrost Heater
shorted out?
Change EVAP. ASS'Y
Check wire assembly

52
TROOUBLE SHOOTING

Does the Function return to


the normal after Heating ?
Normal

Is each concerned Defrost


Sensor Temp higher than the
terminated Temp? Change concerned
Concerned Sensor resistance
measurement(Appendix TABLE) Sensor

Is the input voltage of


MICOM #9 higherthan the
voltage upon the
Concerned Sensor resistance terminated Temp? Change Temp pick-up
measurement(Appendix TABLE) part, Change PCB

Change PCB

53
TROOUBLE SHOOTING
12-6) When Alarm Sound continues without stop

Note
1. When Door gets open, Door Open alarm ("Ding Dong") goes off in 2 minutes with Door
pened.When Door remains open after this, the alarm goes off every minute.
2. When Door Switch is not pressed well, MICOM considers it as opened and alarming sound
goes off. Room Lamp becomes OFF in 10 minutessince it detectsDoor Open (based on
R600a).In this case, even though Door gets opened, Room Lamp does not comes ON.

1) When “Ding Dong ” sound continues

Start
When using R600a Option

Is insertion of MAIN
PCB Connector (CN70)
(PURPLE) normal?
Connector
contact Is insertion of Contact trouble of
defedct, CN31 of MAIN PCB Connector, Insert
Re-insert normal? it again

Does DOOR S/W come


in & out well?

Repair DOOR
S/W pressing part

Is DOOR S/W in itself


normal?
Does voltage of
MICOMPIN #62,63 Change DOOR
change? "0V, 5V" S/W
R-DOOR SIGNAL #63
F-DOOR SIGNAL #62
Are wire connections
between DOOR S/W and
PCB normal?

Repair connection
part
Change PCB /Re-confirm operation

54
Diagnostics
2) When “Beep Beep” sound continues

Start

Is Forced Operation/
Defrost selected?
Cancel Forced Operation/
Defrost
Does buzzing sound
go off when plugging out and
plugging in again?
PCB is normal

Check Lead Touch & foreign substances


around TEST S/W (MICOM #33)

Note
1. "Beep-Beep" sounds do not go off except Forced Operation & Forced Defrost.
2. It is checckableatPanel PCB when Forced Operation or Forced Defrost is selected, so when
error occurs, check it andcorrect theerror.

3) When PANEL PCB doesn ’t light up

Start

Is MAIN PCB 12V normal?


(REG101)
Check REG101 parts,
Change PCB

Is Connector of Upper
Hinge Cover inserted well?
Re-insert Connector,
Check contacts

Is insertion of MAIN PCB


Connector (CN50) normal?
Re-insert MAIN PCB
Connector, Check contacts

Is inssertion of PANEL
PCB Connector normal?
Re-insert PANEL PCB
Connector, Check contacts
Change PANEL PCB

55
TROOUBLE SHOOTING

4) When PANEL PCB KEY is not selected

Start

Is Connector of Upper
Hinge Cover inserted well?
Re-insert Connector,
Check contacts

Is insertion of MAIN PCB


Connector (CN50) normal?
Re-insert MAIN PCB
Connector, Check contacts

Is inssertion of PANEL
PCB Connector normal?
Re-insert PANEL PCB
Connector, Check contacts

Is there any pressed KEY


amoong 4 keys?
Re-assemble PANEL
PCBCOVER
Change PANEL PCB

56
TROOUBLE SHOOTING
12-7) When Room Lamp does not light up

Note
1. Because Room Lamp is basically controled with Door Switch, PCB does not control it.

1) When F&R----Room Lamps do not light up

Start

Is DOOR SwitchOPEN?

DOOR SWITCH
OPEN

Is RoomLAMP(R,F)
normal?

Change LAMP

Is DOOR SWITCH normal?

Change DOOR
SWITCH

Is MICOM #62, 63 "0V"?


R DOOR SIGNAL #63
F DOOR SIGNAL #62
Check wires again
/ Change PCB

Is MICOM#27,#30
HIGH (5V)?
R LAMP #30
F LAMP #27
Check LEAD
TOUCH / Change
PCB
Is MAIN PCB RELAY
normal (RY77,RE74)?
R LAMP RELAY RY77
F LAMP RELAY RY74
Check RELAY /
Change MAIN PCB
Check wires again / Change PCB