tra n sm ission P art s Part Summar y

Complaints Cause Correction


• TCC apply/release problems A sticking lockup relay control sleeve prevents The tightly toleranced, drop-in replacement
• Inadequate lubrication TCC apply or release. Sleeve wear reduces Sonnax lockup relay control valve and sleeve
converter pressure, overheating the fluid, and kit restores proper hydraulic clerances,
• Converter codes
results in bushing and solenoid failure. provides greater valve support and uses
upgraded materials to prevent wear.

Aisin AW 81-40LE, Toyota A340E/F & A650E


Lockup Relay
Control Valve &
Sleeve Kit
Lockup Relay
Part No. Control Valve

77741-02K
• Lockup Relay Control Valve
• Lockup Relay Control Sleeve
A650F Valve Body
Shown Here

Lockup Relay
A340F Valve Body Control Sleeve
Shown Here

81-40LE
Valve Body Shown Here
The Aisin AW 81-40LE, Toyota A340E/F and A650E lockup relay
valves route converter feed fluid pressure to the release side of the converter clutch and apply
fluid into the cooler fluid circuit. Converter feed pressure at the lockup relay control plung-
er valve helps in proper positioning of the inboard lockup relay valve. Wear or sticking at
this plunger valve or sleeve can result in converter apply and release complaints, inadequate
lubrication, overheated fluid, bushing and solenoid failure, and converter codes. The tightly
toleranced drop-in replacement from Sonnax restores the proper hydraulic clearance to main-
tain proper function, and fits all three applications thru special port
arrangements. 20
15
10
25 5
30 0
VACUUM

Features & Benefits


TEST

• Sleeve is manufactured from highly wear-resistant billet aluminum


• Sleeve has been redesigned to eliminate rotational indexing issues
and provide flow 360˚ around the valve to prevent side loading
A650
• Sleeve design incorporates grooves and cross-slots to maximize Valve Body Shown Here
valve support while maintaining proper flow
• Valve is made from hard-coat
anodized aluminum to prevent wear
15
20 10
25 5
30 0
15 VACUUM
20 10 TEST
25 5

You need this if… 30


VACUUM
TEST
0

A vacuum test at the ports indicated fail


to hold at least 18 in-Hg.

A340F 81-40LE