Вы находитесь на странице: 1из 10

KINDER MORGAN CANADA INC.

ENGINEERING STANDARDS AND PRACTICES

CUSTODY TRANSFER
POSITIVE DISPLACEMENT METERS

MP 2411, Revision 0, December 1993


KINDER MORGAN CANADA INC.
ENGINEERING STANDARDS AND PRACTICES
MP2411 Revision 0 December 14, 1993 Page 1 of 8
Title: CUSTODY TRANSFER, POSITIVE DISPLACEMENT METERS

TABLE OF CONTENTS
1.0 SCOPE ............................................................................................................... 2
1.1 General................................................................................................ 2
1.2 Pressure Class .................................................................................... 2
2.0 REFERENCE PUBLICATIONS .......................................................................... 2
3.0 DEFINITIONS..................................................................................................... 3
3.1 Fitting .................................................................................................. 3
3.2 Heat ..................................................................................................... 3
3.3 NPS ..................................................................................................... 3
3.4 PN ....................................................................................................... 3
3.5 Pressure-containing parts.................................................................... 3
4.0 DESIGN.............................................................................................................. 4
4.1 General................................................................................................ 4
4.2 Operating Conditions ........................................................................... 4
4.3 Pulse Transmitter ................................................................................ 4
4.4 Counter................................................................................................ 4
5.0 MATERIALS AND MANUFACTURE .................................................................. 5
5.1 Fluids Handled .................................................................................... 5
5.2 Meter Materials .................................................................................... 5
5.3 Meter Flanges ..................................................................................... 5
5.4 Cleaning and Priming .......................................................................... 5
6.0 CHEMICAL TEST REQUIREMENTS ................................................................. 5
7.0 MECHANICAL TEST REQUIREMENTS ............................................................ 6
7.1 General................................................................................................ 6
7.2 Tensile Tests ....................................................................................... 6
8.0 TESTING AND INSPECTION ............................................................................ 6
8.1 Hydrostatic Testing .............................................................................. 6
8.2 Radiographic Inspection ...................................................................... 6
8.3 Ultrasonic Inspection ........................................................................... 6
9.0 DOCUMENTATION AND REPORTING ............................................................. 7
9.1 Information Required ........................................................................... 7
9.2 Marking................................................................................................ 8
KINDER MORGAN CANADA INC.
ENGINEERING STANDARDS AND PRACTICES
MP2411 Revision 0 December 14, 1993 Page 2 of 8
Title: CUSTODY TRANSFER, POSITIVE DISPLACEMENT METERS

1.0 SCOPE
1.1 General
This standard covers the supply of positive displacement meters for custody
transfer. Unless otherwise noted, meters shall be manufactured in
accordance with the latest edition of the API Manual of Petroleum
Measurement, Chapter 5 Section 2, Measurement of Liquid Hydrocarbons by
Positive Displacement Meters.

1.2 Pressure Class


PN 20, PN 50, and PN 100 (ANSI 150, 300, 600)

2.0 REFERENCE PUBLICATIONS


Where reference is made to other publications, such references shall be
considered to refer to the latest edition of that publication. Some reference
publications are supplemented or qualified, or both, by specific requirements in
this standard; reference publications should therefore be applied only in the
context of this standard.

API Manual of Petroleum Measurement Standards, Chapter 5, Section 2,


Measurement of Liquid Hydrocarbons by Positive Displacement Meters;

API 6D Specification for Pipeline Valves;


CSA Z183 Oil Pipeline Systems;
CSA Z245.11 Steel Fittings;
CSA Z245.12 Steel Flanges;
CSA C22 Canadian Electrical Code;
ANSI B16.5 Pipe Flanges and Flanged Fittings;
ANSI B16.9 Wrought Steel Butt-Welding Fittings;
ANSI B16.11 Forged Steel Fittings, Socket-Welding and Threaded;
ASME B31.3 Chemical Plant and Petroleum Refinery Piping;
KINDER MORGAN CANADA INC.
ENGINEERING STANDARDS AND PRACTICES
MP2411 Revision 0 December 14, 1993 Page 3 of 8
Title: CUSTODY TRANSFER, POSITIVE DISPLACEMENT METERS

3.0 DEFINITIONS
The following definitions apply in this standard:

3.1 Fitting
Unless otherwise specified, for the purposes of this standard, the term fitting
shall include the following classes of fittings: flanges; wrought steel butt-
welding fittings; forged steel threaded and socket-welded fittings; and forged
steel branch outlet fittings.

3.2 Heat
Heat shall mean material produced from the same batch of steel tapped from
a melting furnace for forging, or rolling into plate and made into fittings or
flanges using the same forming, welding and heat treatment procedures.

3.3 NPS
NPS means nominal pipe size, and the NPS system of nominal size
designation is contained in Standards prepared by the American Society of
Mechanical Engineers.

3.4 PN
PN means pressure nominal and the PN system of nominal pressure class
designation is contained in standards prepared by the International
Organization for Standardization (ISO). The numerical part of the
designation approximates the maximum cold working pressure rating in bars
(100 kPa).

3.5 Pressure-containing parts


Those meter parts that, when assembled, form the chamber(s) designed to
contain the pressurized fluid; such parts include bodies, bonnets, covers,
end flanges, and butt-welding ends.
KINDER MORGAN CANADA INC.
ENGINEERING STANDARDS AND PRACTICES
MP2411 Revision 0 December 14, 1993 Page 4 of 8
Title: CUSTODY TRANSFER, POSITIVE DISPLACEMENT METERS

4.0 DESIGN
4.1 General
The meter shall be a straight through, rotary vane, double case, positive
displacement meter with the following requirements:

TABLE 4.1.A -- GENERAL DESIGN REQUIREMENTS


Accuracy Instantaneous flow accuracy shall be  0.15%
Linearity Normal flow rate linearity shall be  0.15%
Units of Measure SI units, cubic meters per hour

4.2 Operating Conditions


The meter shall be designed to operate under the following conditions:

TABLE 4.2.A -- OPERATING CONDITIONS


Pressure Class Max. Operating Pressure (MOP) Design Temperature
PN 20 (ANSI 150) 1900 kPa
PN 50 (ANSI 300) 4960 kPa -29°C to 50°C
PN 100 (ANSI 600) 9930 kPa

Note: Product Temperature -5°C to 25°C

4.3 Pulse Transmitter


The meter shall include a photo-electric pulse security transmitter. The
transmitter shall have dual and complementary pulse output with the
electrical characteristics specified in table 4.3.A. The transmitter shall have
UL and CSA approval for Class 1, Division 1, Group D and meet NEMA 4
requirements.

TABLE 4.3.A -- ELECTRICAL CHARACTERISTICS


Input Load Trigger Thresholds
Dual Pulse Phase Shift
Voltage Impedance Positive Negative
24 Vdc 1 MΩ +4.0 Vdc +3.0 Vdc 90o electrical ± 40° electrical

4.4 Counter
The counter shall be the horizontal type with eight non-resettable digits with
one decimal place plus a graduated disc for hundredths.
KINDER MORGAN CANADA INC.
ENGINEERING STANDARDS AND PRACTICES
MP2411 Revision 0 December 14, 1993 Page 5 of 8
Title: CUSTODY TRANSFER, POSITIVE DISPLACEMENT METERS

5.0 MATERIALS AND MANUFACTURE


5.1 Fluids Handled
All meter materials shall be compatible with the following fluids:
crude oil heavy crude oil gasoline
diesel condensate methanol
MTBE

5.2 Meter Materials


The meter shall be fabricated using the materials specified in table 5.2.A

TABLE 5.2.A -- MATERIAL REQUIREMENTS


Body Trim Elastomers
ASTM A216 WCB
ASTM A216 WCC Standard Buna-N
ASTM A285 GR. C

5.3 Meter Flanges


The meter shall have raised face flange ends. Flanges shall be forged steel
per CSA Z245.12 or equal. Flanges fabricated from plate are uacceptable.

5.4 Cleaning and Priming


If painting is required, the valve shall be thoroughly cleaned, then blast-
cleaned to near white metal per SSPC-SP-10, then prime-coated with 2 to 3
mdft of:

TABLE 5.3.A -- PRIMERS


Paint Manufacturer Primer
Devoe Devran 201
International Intergard EGA088/089
Valspar Valchem 13F62/13R62

6.0 CHEMICAL TEST REQUIREMENTS


The manufacturer shall submit a chemical analysis (ladle, check or product
analysis) for all pressure containing components. The chemical analysis
shall include a report on the following elements and any other intentionally
added elements:

Carbon Manganese Silicon


Phosphorus Sulphur Copper
Nickel Chromium Vanadium
KINDER MORGAN CANADA INC.
ENGINEERING STANDARDS AND PRACTICES
MP2411 Revision 0 December 14, 1993 Page 6 of 8
Title: CUSTODY TRANSFER, POSITIVE DISPLACEMENT METERS

7.0 MECHANICAL TEST REQUIREMENTS


7.1 General
Test results shall be submitted for mechanical properties of all pressure
containing components or from the same type of material, manufactured
using the same procedures and heat treatment, at a frequency of one set of
tests per heat. Where the manufacturer is other than the vendor name
appearing on the Mill Test Certificate, the name of the manufacturer and date
that the component was formed shall be included in the remarks.

7.2 Tensile Tests


The tensile properties of each pressure containing part in the valve shall be
in accordance with the applicable material standard or specification.

8.0 TESTING AND INSPECTION


8.1 Hydrostatic Testing
Hydrostatic testing shall conform to Kinder Morgan Canada Inc. Standard
MP4140. Castings containing repair welding that was made to correct
hydrostatic test defects shall be stress relieved or heat treated after welding.

8.2 Radiographic Inspection


All welds in pressure containing parts shall be radiographically tested through
their entire length and shall meet the requirements of paragraph UW-51 of
ANSI/ASME Boiler and Pressure Vessel Code, Section VIII, Division 1. Such
inspection shall be performed after final heat treatment.

8.3 Ultrasonic Inspection


Where approved by Kinder Morgan Canada Inc., welds may be ultrasonically
inspected. Welds so inspected shall meet the requirements of Appendix 12
of ANSI/ASME Boiler and Pressure Vessel Code, Section VIII, Division 1.
KINDER MORGAN CANADA INC.
ENGINEERING STANDARDS AND PRACTICES
MP2411 Revision 0 December 14, 1993 Page 7 of 8
Title: CUSTODY TRANSFER, POSITIVE DISPLACEMENT METERS

9.0 DOCUMENTATION AND REPORTING


9.1 Information Required
As a minimum, the vendor shall provide all information listed in Table 9.1.A.
The information listed for proposal shall accompany the vendors quotation.
Information listed for approval shall be submitted within four (4) weeks of the
award of the purchase order. Information listed under delivery shall be
submitted within four (4) weeks of delivery of the meter.

TABLE 9.1.A -- INFORMATION REQUIREMENTS


Information provided with Proposal
Information provided for Approval
Information provided Upon Delivery
 Technical description of design and specifications;
 Outline dimensional drawing showing configuration and components;
 Transmitter Wiring Diagrams;
 Priced list of recommended spare parts and options;
 Schedule showing design, detailed drawings, construction, testing, and delivery;
Make and specifications of all auxiliary components such as switches and
 sensors;
 Pressure drop through meter @ minimum, maximum, and design flow rates;
 Identification of coating systems provided;
 Welding procedures to be used in meter fabrication;
  Identification of all materials used for meter pressure containing parts;
  Identification of all materials used for internals;
  Identification of all materials used in the meter trim;
  Identification of all elastomers and non-metallic meter parts;
Two (2) reproducible, dimensional drawings for the meter including bill of
  materials;
Meter calibration certificates, supporting documents and meter calibration
 curves;
 Heat or product analysis for all pressure containing components;
Tensile test results for yield strength, tensile strength and elongation for all
 pressure containing components;
 Pressure test results for all testing requested on meter;
Report outlining the nondestructive inspection completed on any welded
 components and the results;
 Five (5) copies of operation and maintenance manuals.
KINDER MORGAN CANADA INC.
ENGINEERING STANDARDS AND PRACTICES
MP2411 Revision 0 December 14, 1993 Page 8 of 8
Title: CUSTODY TRANSFER, POSITIVE DISPLACEMENT METERS

9.2 Marking
Each meter shall be affixed with a nameplate which shall include the
following information as a minimum:

Manufacture's name Pressure rating at operating temperature


Model number Design capacity
Serial Number Tag number
Nominal Size Purchase order number
SHEET
MP2411 – POSITIVE DISPLACEMENT
METERS DATA SHEET REV

PRESSURE
APPLICATION SIZE (NPS)
CLASS

SPECIFIC GRAVITY RANGE VISCOSITY1 (mm3/sec at 10°C)

DESIGN TEMP RANGE -29°C to 50°C MAX VISCOSITY

OPERATING TEMP RANGE -5°C TO 25°C DESIGN VISCOSITY

MOP (kPa per Table 4.2.A) MIN VISCOSITY

MAX FLOW RATE (m3/hr) FLUIDS HANDLED

DESIGN FLOW RATE (m3/hr) Crude oil Methanol Diesel


M.T.B.E. Gasoline Condensate
MIN FLOW RATE (m3/hr) Heavy crude oil

UNITS OF REGISTRATION Cubic meters per hour

NUMBER OF PULSES PER CUBIC METER 10,000

DIRECTION OF FLOW

METER REQUIREMENTS

END CONFIGURATION Flanged


HYDRO TESTING (per MP 4401)
FLANGE-END FACING Raised Face

DESIGN STANDARD API Chapiter 5 Manual of Petroleum Measurement Standards

OTHER REQUIREMENTS:

1) viscosities in excess of 200 mm2/sec will require greater internal clearances