Вы находитесь на странице: 1из 33

Fourniture, Installation & Mise en

Service de MSAN

TUNISIE TELECOM

Description technique et des services

Alcatel-Lucent – Mars 2015


Sommaire

1 INTRODUCTION ........................................................................................................................ 3
2 SOLUTION & BENEFICES POUR TUNISIE TELECOM...................................................... 4
2.1 Solution globale ................................................................................................................................. 4
2.2 Solution FTTC & Indoor: ALU 7302 & 7330 iSAM ...................................................................... 5
2.3 Solution FTTB: ALU 7353 iSAM FTTB ......................................................................................... 9
3 SOLUTION ONT........................................................................................................................ 11
3.1 Type 1 (4 ports Ethernet et 2 ports POTS, WiFi) ........................................................................ 11
3.2 Type 2 (1 port Ethernet) ................................................................................................................. 11
4 SYSTEME DE GESTION MSAN ............................................................................................. 12
5 CABINETS OUTDOOR............................................................................................................. 13
5.1 CABINET OUTDOOR Type 1 ...................................................................................................... 13
5.2 CABINET OUTDOOR TYPE 2 .................................................................................................... 15
5.3 CABINET OUTDOOR TYPE 2B.................................................................................................. 17
5.4 CABINET OUTDOOR TYPE 3 .................................................................................................... 19
5.5 CABINET OUTDOOR TYPE 3B.................................................................................................. 21
5.6 CABINETS OUTDOOR TYPE 4 .................................................................................................. 23
6 SWITCH D’AGGREGATION ................................................................................................... 25
7 Balise de protection .................................................................................................................... 25
8 DESCRIPTION DES SERVICES ............................................................................................. 26
8.1 Gestion de Projet ............................................................................................................................. 26
8.2 Logistique......................................................................................................................................... 28
8.3 Visite de site ..................................................................................................................................... 28
8.4 Installation & Mise en service ........................................................................................................ 28
8.5 Recette .............................................................................................................................................. 30
8.6 Mise en Y (dans le cas de Swap SR ou central) ............................................................................ 31
9 CALENDRIER D’EXECUTION ............................................................................................... 33
9.1 Délai de livraison ............................................................................................................................. 33
9.2 Calendrier de déploiement ............................................................................................................. 33

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 2/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
1 INTRODUCTION

Ce document présente l’offre d’Alcatel-Lucent à TUNISIE TELECOM pour la fourniture, l’installation et la


mise en service des équipements d’accès (MSAN). La solution proposée va permettre à TUNISIE TELECOM
d’atteindre les objectifs envisagés par le projet :
 Satisfaction des besoins en service POTS, DSL, P2P Ethernet fibre et GPON sur les mêmes
équipements d’accès.
 Remplacement progressif des centraux de commutation et les étages d’abonnés obsolètes.
 Se rapprocher le plus possible du client final via des solutions FTTC et FTTB pour offrir plus de
débit.

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 3/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
2 SOLUTION & BENEFICES POUR TUNISIE TELECOM

2.1 Solution globale


Alcatel-Lucent offre sa famille d’équipements ISAM pour servir les besoins de TUNISIE TELECOM :
 Les châssis 7302 (FD-16) pour les configurations les plus larges (indoor et FTTC)
 Les châssis 7330 (FD-8) pour les sites à moyenne densité (indoor et FTTC)
 Les châssis 7353 pour les déploiements en FTTB.

Conformément aux spécifications de TUNISIE TELECOM, toutes les cartes de service et de contrôle sont
interchangeables entre les châssis ALU 7302 et ALU 7330.

Les châssis proposés pour les configurations indoor et FTTC permettront d’offrir non seulement les
services xDSL et POTS mais aussi les services GPON, P2P et GPON depuis le même équipement. La solution
supporte également :
- les fonctionnalités nécessaires pour le raccordement des stations de base pour le réseau
mobile (synchronisation, …)
- la fonctionnalité « vectoring » VDSL2

La plate-forme matérielle ALU 7353, qui fait partie de la famille de produit iSAM, a été optimlisée pour
des déploiements FTTB, dotée de cartes spécifiques.

Intégration dans le réseau de TUNISIE TELECOM :


D’un point de vue intégration de l’iSAM dans le réseau de TUNISIE TELECOM, Alcatel-Lucent garantit
l’interfonctionnement de la fonctionnalité voix avec les Softswitch Huawei en service dans le réseau
TUNISIE TELECOM.

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 4/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
2.2 Solution FTTC & Indoor: ALU 7302 & 7330 iSAM
Type de châssis :
Le châssis ALU 7302 (FD-16) offre la plus large capacité de la famille iSAM, équipé de :
- cartes de contrôle redondantes (1+1),
- jusqu’ à 16 cartes de lignes pouvant être installées dans les slots universelles,
- un débit de 10Gbps pour chaque slot.

La solution ALU 7302 iSAM supporte les fonctionnalités ADSL, VDSL2, VDSL2 vectoring, Voix (POTS/ISDN,
SIP et H248), GPON et P2P et G-SHDSL.

Le châssis ALU 7330 iSAM (FD-8) dispose des mêmes fonctionnalités, avec pour seule différence le nombre
de slots (les cartes de contrôle redondantes en 1+1, jusqu'à 8 cartes de ligne pouvant être installées).

Cartes de controle :
Notre offre comprend les cartes de contrôle NANT-A dans une configuration 1+1 pour tous les sites sauf les
sites avec GPON et/ou avec du VDSL2 Vectoring, où des cartes NANT-E sont nécessaires.

Chaque site est aussi équipé avec une carte de contrôle avec horloge de haute précision, rendue
nécessaire pour la synchronisation des services voix.

Le tableau ci-après donne les différentes options de cartes de contrôle, adpatée selon la fonctionnalité
requise :

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 5/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
Cartes de ligne :
L’image ci-dessous donne un résumé des cartes de ligne les plus courrament utilisées ; elles sont classées
selon la technologie d’accès (Cuivre ou Fibre) :

Compte tenu des exigences de TUNISIE TELECOM concernant la localisation des filtres xDSL (sur les MDF
pour les déploiements indoor et sur les cartes DSL pour les déploiements FTTC), les cartes suivantes font
partie de la solution proposée par Alcatel-Lucent :

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 6/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
1. Carte à 72 lignes POTS avec ou sans filtres intégrés (configurations indoor et FTTC) (NPOT-B)
2. Carte à 24 lignes RNIS BRI (configurations indoor) (NBAT-B)
3. Carte de serveur pour la fonctionnalité H.248
4. Carte à 72 lignes multi-ADSL sans filtres intégrés (configurations indoor et FTTC)(NALT-E)
5. Carte à 48 lignes multi-ADSL avec filtres intégrés (configurations FTTC)(NALS-A)
6. Carte à 72 lignes VDSL sans filtres intégrés (configurations indoor et FTTC)(NVLT-R)
7. Carte à 48 lignes VDSL avec filtres intégrés et support d’ADSL (configurations FTTC)(NVLS-A)
8. Carte à 24 lignes SHDSL avec fonctionnalité MELT(configurations indoor et FTTC)(NSLT-B)
9. Carte à 8 ports GPON (NGLT-C) (configurations indoor)
10. Carte à 36 ports P2P (NELT-B) (configurations FTTC)

Afin d’être capable d’effectuer les tests Board et System Level Vectoring, les cartes suivantes vont être
utilisées:
11. Carte à 48 lignes VDSL2 avec fonctionnalité Board Level Vectoring
12. Carte à 48 lignes VDSL2 avec fonctionnalité System Level Vectoring
13. Carte de processor System Level Vectoring

Fonction VoIP sur les MSANs :


Quant à la fonctionnalité voix sur IP (VoIP), la solution définie dans l’ISAM Voice (ISAM-V) comprend les
différents sous-ensembles suivants :

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 7/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
La solution ALU ISAM-V supporte tous les scénarii de remplacement des centraux « legacy » de
commutation par une technologie H.248 ou bien SIP. De nombreuses références sont disponibles (dont
TUNISIE TELECOM en Octobre 2008) démontrant l’interopérabilité de la solution ALU ISAM-V avec
différents softswitch comme le Softx300 de Huawei, en service dans le réseau de TUNISIE TELECOM.

La carte ISAM Voice Packet Server (NVPS) se comporte comme une gateway de signalisation H. 248.
Compte tenu de sa grande capacité de traitement, il est envisageable et conseillé de la déployer dans un
scénario centralisé, comme indiqué dans le schéma suivant :

Avec un trafic téléphonique de 0,1 Erlang par abonné, la capacité de traitement d’une carte NVPS englobe
5,000 abonnés :

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 8/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
2.3 Solution FTTB: ALU 7353 iSAM FTTB
Pour les configurations FTTB définies par TUNISIE TELECOM, Alcatel-Lucent propose une solution
optimisée : l’ALU 7353 iSAM FTTB.

Alcatel-Lucent propose les cartes suivantes pour les configurations FTTB envisagées par Tunisie Telecom:

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 9/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
Ci-dessous la composition des deux configurations FTTB1 et FTTB2 :

Désignation FTTB1 FTTB2


Carte POTS 64 ports 1 1
Carte ADSL2+ 32 ports, splitters intégrés 2
Carte VDSL2 32 ports, splitters intégrés 2
Fixation au mur 1 1

Note : La carte NT intègre un DSP ainsi qu’une horloge de haute précision pour le support des services
voix.
Note : Pour offrir plus de fléxibilité à TUNISIE TELECOM dans les scénarii de déploiement, les uplinks sont
interchangeables avec le choix de liaison GPON ou GE.

En cas de microcoupure de courant :


Conformément aux besoins de TUNISIE TELECOM, l’équipement ALU 7353 iSAM FTTB reste imperturbable
aux microcoupures de courant : l’ALU 7353 iSAM FTTB a été conçu pour permettre de brancher une
batterie externe et ainsi garantir la continuité du service, même après une microcoupure de courant
comme indiqué dans le schéma ci-dessous :

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 10/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
3 SOLUTION ONT
Pour les déploiements GPON, Alcatel-Lucent propose les ONTs détaillés dans les paragraphes suivants.

3.1 Type 1 (4 ports Ethernet et 2 ports POTS, WiFi)

GPON RGW INDOOR ONT: G-240W-A

 FEATURES  BENEFITS
• GPON Uplink, G.984, G.988 series standard
compliant • Integrated residential
• 2 POTS ports gateway for GPON
• 4 RJ-45 10/100/1000 auto negotiating Network, one box solution
Ethernet ports for FTTH deployment.
• Dynamic Bandwidth Allocation (DBA) • Supports full triple play:
• IPTV, IGMPv2 and IGMPv3 Voice, Data, IPTV
• AMS Managed
• Optical RSSI, advanced PMs and statistics • Full range of fault
support management,
• Per-subscriber, per-service bandwidth configuration, accounting,
performance, and security
G-240W-A •
control
Support bridge Mode or routed Mode for (FCAPS) functions Dimensions 208*142*33(mm)/8.2*5.6*1.3(in.)
2POTS+4GE+WiFi each Ethernet port
Weight 330g
• TR-69 support,TR142 compliant
• Support 100mw 802.11n 2x2 WiFi for Operating 0°C to 45°C
generic customers Temp

• WPS on wireless authorization support Mounting Desk or wall mounted


• 4 SSIDs
Power Spec. +12V (with external AC/DC adapter)
• 2 USB2.0 interfaces
• Firewall, NAT, PPPoE, DHCP Power <18W
• BRCM 6838SOC. Flexible NP solution to Consumption

extend functions according to customers’ LEDs PWR, LINK, AUTH, LAN 1-4, TEL 1-2,
future requirement VOIP, WPS, WLAN, USB, INTERNET

2
COPYRIGHT © 2014 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION

3.2 Type 2 (1 port Ethernet)

ONT TYPE 1 – DATA ONLY ONT (BRIDGED)


G-010G-A

KEY FEATURES

• 1/4x10/100/1000BaseT.
• GPON G.984.1,2,3, OMCI
• Tagging/Retagging/Priority Bit setting
• Full video support with Multicast, IGMP v2 & 3
snooping, expedited leave, IGMP rate limiting
• Operating Case Temp 0 C to +45 C
• Dimensions
•LxWxH 10.5 x 8.2 x 3.65 cm

1
COPYRIGHT © 2014 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 11/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
4 SYSTEME DE GESTION MSAN

La gestion du réseau des MSANs se réalise à travers l’application ALU 5520 AMS, aujourd’hui en service
dans le réseau de TUNISIE TELECOM.

Ce système de gestion du réseau MSANs ayant été mis à jour l’année dernière avec deux nouveaux
serveurs Oracle à base de quatre Core XEON CPUs avec la version ALU 5520 AMS Release 9.1.10, les
équipements proposés dans cette offre (dans la version iSAM R4.4) seront supervisables automatiquement
sans nécessiter de modifications sur ce système de gestion.

Alcatel-Lucent suggère de faire une mise à jour des nœuds existants dans le réseau de Tunisie Telecom
qui sont dans release 4.3 vers le release 4.4 afin de n’avoir qu’un seul release dans le réseau. C’est une
des options proposées dans la partie commerciale de notre offre.

Le dimensionnement du système de gestion ALU 5520 AMS déployé l’année dernière dans le NOC de
TUNISIE TELECOM couvre aussi bien la gestion des nœuds et des lignes existantes que ceux exigés dans le
présent cahier de charge pour la portée maximale sur trois années, avec 90 accès simultanés d’opérateur
avec un comportement semblable à celui d’aujourd’hui. Si le nombre d’interactions par opérateur change
considérablement, l’achat des serveurs plus puissants peut devenir souhaitable. C’est une des options
proposées dans la partie commerciale de notre offre.

Interfaces nord de l’ALU 5520 AMS :


L’application ALU 5520 AMS supporte les interfaces ouvertes vers des systèmes OSS :
 L’application IDM pour l’inventaire
 L’application APC pour la configuration
 L’application OAD pour les alarmes
 L’application SDC pour la performance
Note : Comme alternative, les systèmes OSS peuvent aussi être interconnectés par une « gateway TL1 ».

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 12/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
5 CABINETS OUTDOOR

Ce chapitre se focalise sur la description des Cabinets Outdoor utilisés dans les configurations de type
FTTC.

5.1 CABINET OUTDOOR Type 1


Ci-dessous sont représentés les schémas du cabinet prévu pour les configurations FTTC Type 1 de
dimensions (1050 x 700 x 600) avec 100 paires côté ISP et 100 paires côté OSP :

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 13/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
D’autres informations sont listées ci-après :
- Dimensions internes du cabinet : 1050(h) x 700(l) x (600 (p)+HEX(p))
- Consitution du cabinet :
o Alliage d’aluminium, paroi double,
o portes frontales pour la partie électronique,
o porte latérale pour la partie MDF et batteries,
o 20U disponible pour les équipements, redresseurs et ODF

- Catégorie de protection: IP55 à EN 60 529/10.91

- Technique de refroidissement : Heat Exchanger type 35W/K.

- Les redresseurs proposés sont :


o de marque Delta,
o de type modulaire, avec des emplacements prévus dans les cabinets pour de futures
extensions,
o Modèle = DPS 850B-48-3 19IN CellD 40 avec 2 redresseurs de 850W :
• équipé d’un contrôleur PSC3
• 3 disjoncteurs de charge (jusqu’à 6 possible)
• 1 disjoncteur de batterie (jusqu’à 2 possible)
o Les batteries sont du type Sonnenschein A412/50 série de batteries GEL 50Ah offrant
un backup de 4h. (10h courant de recharge)

- Les MDF proposés sont basés sur des modules Nexans :


o Côté ISP: 1x 100pair Compax
o Côté OSP: 1x 100pair Compax

- Un Optical Distribution Frame (ODF) de 48 ports, pré-équipé pour 2 connections optiques, type
LC + 2 pigtails.

Note : La gestion des alarmes de l’environnement se réalise via l’ISAM

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 14/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
5.2 CABINET OUTDOOR TYPE 2
Ci-dessous sont représentés les schémas du cabinet prévu pour les configurations FTTC Type 2 (1x7330).

Sloped roof with louvers

100
MDF/MEC
separation plate AC meter
box

MDF cable hole


80mm(h)x350mm(d)

Wooden board
ISAM 7330

400

600

1750
MDF
1500

ODF 1U(h) x 19IN (w)


ODF 1U(h) x 19IN (w)
Battery cable through Rectifier/distribution 1U(h)
250

MEC and MDF AC distribution


3U(h) x19IN (w) x150(d)
grounding bars
700
300

Cable entries Leoch Leoch


LPG12-45 LPG12-45
String #1 String #2
50

1020

1030

Cable Entry

Equipment
Side Door
Side Door

Wooden board

+ power
Sonnenschein
400
350

720

MD
A412/50
F String #1
String #2

250
HEX
MDF cable
hole

MEC and MDF


AC meter box
grounding bar Front Door

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 15/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
D’autres informations sont listées ci-après :
- Dimensions du cabinet (externes) : 1750(h) x 1029(l) x 731 (p)
- Constitution du cabinet :
o Alliage d’aluminium, paroi double,
o portes frontales pour la partie électronique,
o porte latérale pour la partie MDF et batteries,
o 24U disponible pour les équipements, redresseurs et ODF
- Catégorie de protection: IP55 à EN 60 529/10.91
- Cabinet 220 V AC externe dime 600*400*250mm sur coté droite avec fenetre en plexiglass et
protection métallique.
- Technique de refroidissement : Heat Exchanger type 80W/K

- Les redresseurs proposés sont :


o de marque Delta,
o de type modulaire, avec des emplacements prévus dans les cabinets pour de futures
extensions,
o Modèle = DPS 850B-48-3 19IN CellD 40 avec redresseurs :
 3x850W pour.
 équipé d’un contrôleur PSC3
 3 disjoncteurs de charge (jusqu’à 6 possible)
 2 disjoncteur de batterie (jusqu’à 2 possible)

- Les batteries sont du type Leoch LPG12-45 : 2 séries de batteries GEL 45Ah offrant un backup
de 4h. (10h courant de recharge)

- Les MDF proposés sont basés sur des modules Sunsea :


o côté ISP: max 384p.
o côté OSP: max 1400p

720

MDF hole
ALARMS
96 96

96
OSP 96 OSP
100p 100p

OSP OSP OSP


Hooks for jumper

100p 100p 100p


1500

wires

OSP OSP OSP


100p 100p 100p

OSP OSP OSP


100p 100p 100p
MDF grounding bar

OSP OSP OSP


100p 100p 100p

Clamp bar

- Un Optical Distribution Frame (ODF) de 2*24 ports, pré-équipé pour 2 connections optiques,
type LC + 2 pigtails.

Note : La gestion des alarmes de l’environnement se réalise via l’ISAM

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 16/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
5.3 CABINET OUTDOOR TYPE 2B
Ci-dessous sont représentés les schémas du cabinet prévu pour les configurations FTTC Type 2B (1x7330).

Sloped roof with louvers

100
MDF cable hole
80mm(h)x350mm(d)

MDF/MEC
separation plate
AC meter box

ISAM 7330

Wooden board

400

2000
600
MDF

ODF 1U(h) x 19IN (w)


ODF 1U(h) x 19IN (w)
Rectifier/distribution 1U(h)
250

MEC and MDF AC distribution Battery cable


3U(h) x19IN (w) x150(d) through
grounding bars
700
350

Cable entries Leoch Leoch


LPG12-45 LPG12-45
String #1 String #2
50

1020
1030

Cable Entry
Side Door

Equipment
Side Door

Wooden board

+ power
400

Sonnenschein
350

720

MD
A412/50
F String #1
String #2

250
HEX
MDF cable
hole

MEC and MDF AC meter box


grounding bar Front Door
Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 17/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
D’autres informations sont listées ci-après :
- Dimensions du cabinet (externes) : 2000(h) x 1029(l) x 731 (p)
- Constitution du cabinet :
o Alliage d’aluminium, paroi double,
o portes frontales pour la partie électronique,
o porte latérale pour la partie MDF et batteries,
o 24U disponible pour les équipements, redresseurs et ODF
- Catégorie de protection: IP55 à EN 60 529/10.91
- Cabinet 220 V AC externe dime 600*400*250mm sur coté droite avec fenetre en plexiglass et
protection métallique.
- Technique de refroidissement : Heat Exchanger type 80W/K

- Les redresseurs proposés sont :


o de marque Delta,
o de type modulaire, avec des emplacements prévus dans les cabinets pour de futures
extensions,
o Modèle = DPS 850B-48-3 19IN CellD 40 avec redresseurs :
 3x850W .
 équipé d’un contrôleur PSC3
 3 disjoncteurs de charge (jusqu’à 6 possible)
 2 disjoncteur de batterie (jusqu’à 2 possible)

- Les batteries sont du type Leoch LPG12-45 : 2 séries de batteries GEL 45Ah offrant un backup
de 4h. (10h courant de recharge)

- Les MDF proposés sont basés sur des modules Sunsea :


o côté ISP: max 672p.
o côté OSP: max 1800p
720

MDF hole
ALARMS

96 96
96 96
96
96
96

OSP OSP OSP


100p 100p 100p
Hooks for jumper

OSP OSP OSP


100p 100p 100p
wires
1850

OSP OSP OSP


100p 100p 100p

OSP OSP OSP


100p 100p 100p

OSP OSP OSP


MDF grounding bar

100p 100p 100p

OSP OSP OSP


100p 100p 100p

- Un Optical Distribution Frame (ODF) de 2*24 ports, pré-équipé pour 2 connections optiques,
type LC + 2 pigtails.

Note : La gestion des alarmes de l’environnement se réalise via l’ISAM

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 18/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
5.4 CABINET OUTDOOR TYPE 3
Ci-dessous sont représentés les schémas du cabinet prévu pour les configurations FTTC Type 3 (1x7302).

1030

240 790

Sloped roof with

100
louvers

MDF cable hole Air exhaust space


80mm(h)x450m
m(d)

MDF/MEC

NTIO/17
NTB/18
NTA
01
02
03
04
05
06
07
08

09
10

12
13
14
15
16
11
separation plate AC meter
box

ISAM7302

Fan unit

Wooden board
Connector area

MDF
Air intake space

400

2000
600
ODF 1U(h) x 19IN (w)
ODF 1U(h) x 19IN (w)

Rectifier/distribution 3U(h)

AC distribution Battery cable


3U(h) x19IN (w) x150(d)
through
700

MEC and MDF


grounding bars 710
350

Cable entries 2xLPG12-85 2xLPG12-85


String#1 String#2

1030
240

Cable Entry
Side Door

Equipment
Wooden board
Side Door

400
350

+ power
Leoch LPG12-85
Sonnenschein
720

MDF
A412/50
String #1
String #2

250

HEX
MDF cable
hole

MEC and MDF AC meter box


grounding bar Front Door
Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 19/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
D’autres informations sont listées ci-après :
- Dimensions du cabinet (externes) : 2000(h) x 1029(l) x 731 (p)
- Constitution du cabinet :
o Alliage d’aluminium, paroi double,
o portes frontales pour la partie électronique,
o porte latérale pour la partie MDF et batteries,
o 24U disponible pour les équipements, redresseurs et ODF
- Catégorie de protection: IP55 à EN 60 529/10.91
- Cabinet 220 V AC externe dime 600*400*250mm sur coté droite avec fenetre en plexiglass et
protection métallique.

- Technique de refroidissement : Heat Exchanger type 150W/K

- Les redresseurs proposés sont :


o de marque Delta,
o de type modulaire, avec des emplacements prévus dans les cabinets pour de futures
extensions,
o Modèle = DPS 850B-48-3 19IN CellD 40 avec redresseurs :
 2x2900W.
 équipé d’un contrôleur PSC3
 3 disjoncteurs de charge (jusqu’à 6 possible)
 2 disjoncteur de batterie (jusqu’à 2 possible)

- Les batteries sont du type Leoch A412-85 : 2 séries de batteries GEL 78Ah offrant un backup de
4h. (10h courant de recharge)

- Les MDF proposés sont basés sur des modules Sunsea :


o côté ISP: max 768 paires.
o côté OSP: max 1800 paires.
720

MDF hole
ALARMS
96 96
96 96 96

96 96 96

OSP OSP OSP


100p 100p 100p
Hooks for jumper

OSP OSP OSP


100p 100p 100p
wires
1850

OSP OSP OSP


100p 100p 100p

OSP OSP OSP


100p 100p 100p

OSP OSP OSP


MDF grounding bar

100p 100p 100p

OSP OSP OSP


100p 100p 100p

- Un Optical Distribution Frame (ODF) de 2*24 ports, pré-équipé pour 2 connections optiques,
type LC + 2 pigtails.

Note : La gestion des alarmes de l’environnement se réalise via l’ISAM

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 20/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
5.5 CABINET OUTDOOR TYPE 3B
Ci-dessous sont représentés les schémas du cabinet prévu pour les configurations FTTC Type 3B (1x7302+
1*7330).

MDF Equipment Equipment

Sloped roof with louvers


MDF cable hole
60mm(h)x450mm(d)

MDF/MEC Air exhaust space


separation plate

ISAM7302/2
NTIO/17
NTB/18
NTA
01
02
03
04
05
06
07
08

09
10

12
13
14
15
16
11
ISAM 7330

Wooden board
MDF Fan unit

Connector area
AC power and Fiber cable

400
hole Air intake space

2000
600
60mm(d)x300mm(h)
ODF 1U(h) x 21'' (w)
Rectifier/distribution 5U(h) ODF 1U(h) x 21'' (w)

AC distribution
3U(h) x19IN (w) x150(d)
250

700
Leoch LPG12-125 Leoch LPG12-125
Cable entries 280(h) x 345(w) 280(h) x 345(w)
x 172(d) x 172(d)
100

1770

MEC and MDF


grounding bars
Battery cable through
MDF cable
hole Battery cable
through
Cable Entry 1790

Equipment Equipment
Sonnenschein A412/120 Sonnenschein A412/120
Wooden board

Side Door

223(h) x 669(w) 223(h) x 669(w)


400
350
850

Side MDF x 736(d) x 736(d)


door

250
HEX HEX

AC meter box
MEC and MDF
grounding bar
Front door Front door

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 21/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
D’autres informations sont listées ci-après :
- Dimensions du cabinet (externes) : 2000(h) x 1773(l) x 868 p)
- Constitution du cabinet :
o Alliage d’aluminium, paroi double,
o portes frontales pour la partie électronique,
o porte latérale pour la partie MDF et batteries,
o 24U disponible pour les équipements, redresseurs et ODF
- Catégorie de protection: IP55 à EN 60 529/10.91
- Cabinet 220 V AC externe dime 600*400*250mm sur coté droite avec fenetre en plexiglass et
protection métallique.

- Technique de refroidissement : Heat Exchanger type 2*120 W/K

- Les redresseurs proposés sont :


o de marque Delta,
o de type modulaire, avec des emplacements prévus dans les cabinets pour de futures
extensions,
o Modèle = DPS 850B-48-3 19IN CellD 40 avec redresseurs :
 3*2900 W.
 équipé d’un contrôleur PSC3
 3 disjoncteurs de charge (jusqu’à 6 possible)
 2 disjoncteur de batterie (jusqu’à 2 possible)

- Les batteries sont du type Leoch A412-150 : 2 séries de batteries GEL 150Ah offrant un backup
de 4h. (10h courant de recharge)

- Les MDF proposés sont basés sur des modules Sunsea :


o côté ISP: max 1152 paires.
o côté OSP: max 2000 paires.
800

MDF hole ALARMS

96 96 96 96

96 96 96 96

96 96 96 96

OSP OSP OSP OSP


100p 100p 100p 100p
Hooks for jumper
wires
1800

OSP OSP OSP OSP


100p 100p 100p 100p

OSP OSP OSP OSP


100p 100p 100p 100p

OSP OSP OSP OSP


100p 100p 100p 100p Power/Optical
Cable Through

OSP OSP OSP OSP


100p 100p 100p 100p
Clamp bar

MDF GND
bar
Cable Entry

- Un Optical Distribution Frame (ODF) de 2*24 ports, pré-équipé pour 2 connections optiques,
type LC + 2 pigtails.
Note : La gestion des alarmes de l’environnement se réalise via l’ISAM

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 22/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
5.6 CABINETS OUTDOOR TYPE 4
Ci-dessous sont représentés les schémas du cabinet prévu pour les configurations FTTC Type 4 (2x7302).

MDF Equipment Equipment

Sloped roof with louvers


MDF cable hole
60mm(h)x450mm(d)

MDF/MEC Air exhaust space Air exhaust space


separation plate

ISAM7302/2
NTIO/17

NTIO/17
NTB/18

NTB/18
AC meter
NTA

NTA
01
02
03
04
05
06
07
08

09
10

12
13
14
15
16

01
02
03
04
05
06
07
08

09
10

12
13
14
15
16
11

11
box
ISAM7302/1

Wooden board
MDF Fan unit Fan unit

Connector area Connector area


AC power and Fiber cable

400
hole Air intake space Air intake space

2000
600
60mm(d)x300mm(h)
ODF 1U(h) x 21'' (w)
Rectifier/distribution 5U(h) ODF 1U(h) x 21'' (w)

AC distribution
3U(h) x19IN (w) x150(d)
250

700
Leoch LPFG12- Leoch LPFG12-
Cable entries 150 287(h) x 150 287(h) x
450(w) 450(w)
x 551(d) x 551(d)
100

1770

MEC and MDF


grounding bars
Battery cable through
MDF cable
hole Battery cable
through
Cable Entry 1790
Wooden board

Side Door

Sonnenschein A412/120 Sonnenschein A412/120


400
350

Equipment Equipment
223(h) x 669(w) 223(h) x 669(w)
850

Side MDF x 736(d) x 736(d)


door

250

HEX HEX

AC meter box

MEC and MDF


grounding bar
Front door Front door

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 23/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
D’autres informations sont listées ci-après :
- Dimensions du cabinet (externe) : 2000(h) x 1773(l) x 868 (p)
- Constitution du cabinet :
o Alliage d’aluminium AlMg3,
o paroi double,
o 2 portes frontales pour la partie électronique,
o 1 porte latérale pour la partie MDF
o 31U disponible pour les équipements, redresseurs et ODF

- Catégorie de protection: IP55 à EN 60 529/10.91


- Cabinet 220 V AC externe dime 600*400*250mm sur coté droite avec fenetre en plexiglass et
protection métallique.

- Technique de refroidissement : Heat Exchanger type (installé sur la porte): 2 x150W/K.

- Les redresseurs proposés sont :


o de marque Delta,
o de type modulaire, avec des emplacements prévus dans les cabinets pour de futures
extensions,
o Modèle = DPS 2900B-48-3 avec redresseurs :
 3x2900W
 équipé d’un contrôleur PSC3
 Les batteries sont du type Leoch A412-150 : 2 séries de batteries GEL 150Ah
offrant un backup de 4h. (10h courant de recharge)

- Les MDF proposés sont basés sur des modules Nexans :


o côté ISP: max 1152 paires.
o côté OSP: max 2000 paires. 800

MDF hole ALARMS

96 96 96 96

96 96 96 96

96 96 96 96

OSP OSP OSP OSP


100p 100p 100p 100p
Hooks for jumper
wires
1800

OSP OSP OSP OSP


100p 100p 100p 100p

OSP OSP OSP OSP


100p 100p 100p 100p

OSP OSP OSP OSP


100p 100p 100p 100p Power/Optical
Cable Through

OSP OSP OSP OSP


100p 100p 100p 100p
Clamp bar

MDF GND
bar
Cable Entry

- Un Optical Distribution Frame (ODF) de 24 ports, pré-équipé pour 2 connections optiques, type
LC + 2 pigtails.
Note : La gestion des alarmes de l’environnement se réalise via l’ISAM

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 24/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
6 SWITCH D’AGGREGATION

Afin d’éviter les connexions en cascade, un switch d’agrégation est proposé dans le cas où plusieurs MSAN
sont déployés sur un même site.

Alcatel-Lucent propose l’équipement 7210SAS-M pour ces sites, avec les caractéristiques suivantes :

7 Balise de protection
Comme demandé par TUNISIE TELECOM, notre offre inclus des balises de protection destinées aux sites
Outdoor (au nombre de 40 balises).

Il est à noter que chaque balise de protection est en tube acier galvanisé de longueur 110 cm (dont 100
cm au dessus du sol), le diamètre du tube est de 114 mm avec une épaisseur de 2mm installé sur un socle
en béton armé de dimension 50x50x20 cm. Le béton est coulé dans le tube lors de la réalisation du socle
pour obtenir une résistance élevée à la torsion et au choc. Le socle et l’intérieur du tube sont renforcés
par un ferraillage léger. Le tube est peint en couleur rouge et blanc.

Note : Le nombre de sites Outdoor protégés dépendant de l’emplacement des Cabinets Outdoor, le BOQ
pourra être revu suite aux conclusions du site survey.

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 25/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
8 DESCRIPTION DES SERVICES

Ce paragraphe décrit l’organisation mise en place par Alcatel-Lucent pour la réalisation du projet de
fourniture, d’installation et de mise en service de MSAN.

Les paragraphes qui suivent décrivent les services de déploiement proposés :


 Gestion de Projet,
 Visite de site,
 Installation & Mise en service,
 Tests de recette,
 Mise en Y et swap,
 Interfonctionnement entre les MSAN et les Softswitch du réseau de TUNISIE TELECOM

Le personnel d’Alcatel-Lucent pourrait-être amené dans certains cas à utliser des outils et logiciels
propriétaires. Il est à noter que notre offre ne comprend pas la vente, ni le transfert des licences de ces
outils et logiciels.

Les services de formation et de Garantie/Maintenance sont décrits dans des documents séparés, comme
exigé par TUNISIE TELECOM.

8.1 Gestion de Projet


L’organisation mise en place pour la réalisation de ce projet est présentée ci-dessous :

GPM
Fakhreddine Ayachi

PM Sourcing & Subco Mgmt


MSM
Fakhredine Project Office
Hatem Bouallègue Farouk Ben Hassine
Ayachi

TPM Roll-out OM
Hafedh Guizani Makram Zellit Corinne Davenne

Integration Field Force PFC


Team Team (I&C)

PMO/PMS
Faouzia Ben Khalifa

Quality Support

Les rôles et fonctions mentionnés dans l’organigramme sont détaillés ci-après :

GPM (Global Program Manager ou Chef de Projet)


Le Chef de Projet doit être le point d’entrée unique de TUNISIE TELECOM pour tous les aspects
contractuels du projet.

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 26/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
Son rôle est de planifier, contrôler et surveiller tous les aspects de ce projet. Il est responsable de la
gestion des équipes d’Alcatel-Lucent et de toutes les activités du projet depuis son lancement jusqu’à sa
clôture.

Le Chef de Projet assure le contrôle du projet en respectant les processus standards de gestion de projet :
 Analyse des risques
 Contrôle et suivi des changements/modifications
 Critères d’acceptation et de recette
 Réunion d’avancement à intervalle régulier
 Rapport d’avancement

Le Chef de Projet établit, en accord avec TUNISIE TELECOM, un plan projet détaillé qui doit inclure au
minimum le calendrier d’exécution du projet avec tous ses jalons importants. TUNISIE TELECOM doit ainsi
remplir les pré-requis de préparation des sites selon le calendrier.

Un rapport d’avancement régulier est communiqué à TUNISIE TELECOM tout au long du projet.

En plus de cela, des réunions d’avancement régulières entre le Chef de Projet et les responsables du
projet de TUNISIE TELECOM sont programmées afin de suivre de près le déroulement du projet. La
fréquence de ces réunions est fixée au moment du lancement du projet.

PM (Project Manager)
Le Project Manager est responsable du déploiement du projet depuis la définition technique de la solution
(avec la contribution du TPM) jusqu’à son implémentation sur le site (en se reposant sur le Roll-Out
manager).

TPM (Technical Program Manager ou Chef de Projet Technique)


Le Chef de Projet Technique est responsable de l’implémentation technique de la solution globale, et à ce
titre il est en charge de l’analyse de risques.

Roll-Out (Responsable des Opérations)


Le Responsable des Opérations a en charge la gestion des équipes et des personnes qui réalisent le
repérage des sites, l’installation, le câblage, les tests et la recette.
Il reçoit le rapport des équipes d’installation et de recette, et il est par conséquent le point d’escalade
des équipes d’installation et de recette.

MSM (Maintenance Service Manager)


Le MSM est le point de contact unique de TUNISIE TELECOM pour tous les aspects liés à la garantie et au
contrat de Maintenance des équipements déployés.

Project Office
Le Project Office englobe les fonctions suivantes :
- Order Management pour le lancement des commandes, le suivi des expéditions et la
facturation associée
- Project Financial Controller (Contrôle de gestion financière lié au projet)
- PMO/PMS pour, entre autre, le suivi du dédouannement des équipements, des recettes
provisoire et définitive
- Quality Support pour la démarche qualité sur le projet (garantir le suivi du process,
amélioration de la satisfaction client)

Sourcing & Subco Management (Service Achats)


Le service achats est en relation avec les sous-traitants et fournisseurs pour les besoins du projet.

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 27/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
8.2 Logistique
Le dédouanement du matériel importé est pris en charge par Alcatel-Lucent. Les droits et taxes sont à la
charge de Tunisie Telecom.
Alcatel-Lucent a la responsabilité du transport du matériel dédouané jusqu’au dépôt de Tunisie Telecom.
Alcatel-Lucent prend en charge aussi le transport du matériel du dépôt de Tunisie Telecom jusqu’au site à
installer.

8.3 Visite de site


Le repérage des sites est la possibilité d’évaluer les locaux de TUNISIE TELECOM afin de s’assurer et de
vérifier que les sites sont bien adaptés à l’installation des équipements proposés. Les points qui sont
passés en revue lors de la visite de repérage des sites sont :
 Accès au site, aux salles,
 Disponibilité de l’alimentation,
 Conditions environnementales,
 Espace et emplacement pour les équipements proposés,
 Contraintes de sécurité,
 Contraintes de câblage,
 Equipements périphériques.

Le partage des responsabilités sur les pré-requis de chacun des sites est discuté et agréé lors de cette
visite. A la suite du repérage des sites, un rapport est rédigé et une copie est envoyée à TUNISIE
TELECOM.

Il est recommandé que le repérage de site soit effectué le plus tôt possible. L’objectif de ces repérages
est d’établir les pré-requis physiques pour l’installation. Le repérage est effectué sur chacun des sites de
TUNISIE TELECOM par Alcatel-Lucent et avec un représentant de TUNISIE TELECOM.

Dans le but de respecter le planning du projet, Alcatel-Lucent se réserve le droit de demander l’accès aux
sites à tout moment pour réaliser le repérage, à condition que la demande soit faite suffisamment à
l’avance.

Dans le cas où une nouvelle visite serait nécessaire pour terminer le repérage, pour des raisons en dehors
d’Alcatel-Lucent, des charges supplémentaires pour le temps passé, le matériel et les dépenses
occasionnées peuvent être appliquées.

8.4 Installation & Mise en service


8.4.1 Installation & Mise en service des sites Indoor
L’installation & Mise en service des équipements proposés dans notre offre est réalisée par Alcatel-Lucent.
Les activités sont :
 Déballage des équipements et des câbles associés,
 Pose et fixation des bâtis, avec la connexion vers le coffret d’énergie 48V mis à disposition par
Tunisie Telecom dans la salle équipement (distance maximale de 10m) et la mise à la terre,
 Installation des cartes réseaux et de contrôle dans les châssis,
 Installation des jarretières Fibre Optique jusqu’à l’ODF existant de Tunisie Telecom,
 Installation des câbles depuis les équipements vers le répartiteur client :
o Pose des réglettes incluses dans notre offre sur les répartiteurs de TUNISIE TELECOM,
o Pose des câbles sur les chemins de câble existants vers le répartiteur de TUNISIE TELECOM
selon les longueurs mentionnées dans la liste du matériel. Au cas où des nouveaux chemins
de câble sont nécessaires, cet item est prévu dans notre offre financière en option.
o Connexion des câbles sur le répartiteur de TUNISIE TELECOM,
o Etiquetage et test des câbles,
 Installation des cartes de ligne, de trafic et des modules splitter.

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 28/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
 Démarrage des équipements et mise en service
 Integration au niveau du système de gestion.

TUNISIE TELECOM a la responsabilité de fournir les ateliers d’énergie, les prises à la terre adaptées à la
connexion des équipements proposés dans notre offre. Il est grandement conseillé que la distance entre
eux ne dépasse pas les 10 mètres.

Les pré-requis au début de l’installation sont :


 Repérage de site effectué,
 Configuration des équipements connue pour chacun des sites,
 Autorisation d’accès aux sites et bâtiments (et éventuellement remise de clés pour les sites
distants non occupés),
 Les coordonnées d’un contact de TUNISIE TELECOM pour toute question liée aux équipements,
 Garantie absolue que les sites sont prêts pour l’installation.

8.4.2 Installation & Mise en service des sites avec Cabinet Outdoor
En ce qui concerne les sites nécessitant l’installation d’un Cabinet Outdoor, Alcatel-Lucent réalisera les
prestations suivantes.
Un schéma général d’installation est donné ci-après :

SR Tranchée 5 m max Cabinet Outdoor Socle en béton

Niche
Energie
Trottoir

Chambre L2

Rue

Chambre SR existante Infrastructure TT existante

Infrastructure TT existante Chambre existante

Nouvelle infrastructure à réaliser Nouvelle Chambre L2T et


niche à réaliser

Partie Génie civil sur l’infrastructure incluant :


- Survey site
- Réalisation des plans de recollement (pré-requis : fourniture par Tunisie Télécom des plans
des infrastructures existantes sous forme électronique)

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 29/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
- Fouille traditionel (1,00 x 0,40 m) et pose de 4 fourreaux HDPE de diamètre extérieur 40 mm
pour les distances inférieures à 5m .
Pose et enrobage des fourreaux dans du sable
Remblai avec de la terre tamisé exempt de caillou
Compactage par couche de 20 cm
- Fourniture et installation d’un puit de terre (résistance < 10 Ohm)
- Confection d’un socle en béton dimensionné selon le cabinet à installer (béton armé)
- Construction d’un muret en brique de dimension P.0,25 m x L. 0,6m x H.1,4 m abritant la
niche pour le compteur énergie primaire. Les démarches administratives auprès de l’opérateur
d’électricité (STEG) ainsi que l’installation du compteur est à la charge de Tunisie Telecom.
- Construction d’une chambre L2 (Longueur, Largeur, Hauteur : 116x38x60 cm) avec trappe en
tôle striée galvanisée servant au passage des câbles d’énergie primaire, de distribution cuivre
et de Fibre Optique.
- Réalisation des masques de fourreaux dans la chambre SR existante.
- Fourniture et pose des balises de protection (si jugé nécessaire) simultané à la réalisation du
génie civil
- Réfection des surfaces en béton, asphalte ou repose des pavés autobloquants existants.

Partie câblage dans le cas d’une mise en Y incluant :


- Pose du câble cuivre de passe entre la chambre SR et le cabinet outdoor
- Raccordement et réalisation des manchons voir …8.6.2 Mise en Y
- NB : la pose du câble FO jusqu’au cabinet outdoor est sous la responsabilité de Tunisie
Telecom

Partie Installation du cabinet outdoor incluant :


- Pose et fixation du Cabinet Outdoor sur le socle en béton
- Installation des batteries et raccordement à l’atelier d’énergie fourni avec le Cabinet Outdoor

Partie raccordement et mise en service du cabinet outdoor incluant :


- Raccordement de l’énergie primaire entre le compteur et le cabinet outdoor (Inclus fourniture
et pose du cable d’énergie)
- Raccordement des câbles Cuivre entre l’équipement et le MDF fourni avec le Cabinet Outdoor
- Raccordement des Jarretières Optiques sur l’ODF fourni avec le Cabinet Outdoor
- Démarrage des équipements et mise en service
- Intégration au niveau du système de gestion

Les pré-requis au début de l’installation sont :


 Repérage de site effectué,
 Définition de la localisation du cabinet outdoor et fourniture des plans de l’infrastructiure
existante sous forme électronique par Tunisie Telecom
 Obtention par Tunisie Telecom de toutes les autorisations nécessaires, entre autre celle de
l’occupation du trottoir et de la construction.
 Configuration des équipements connue pour chacun des sites,
 Les coordonnées d’un contact de TUNISIE TELECOM pour toute question liée aux équipements,
 Garantie absolue que les sites sont prêts pour l’installation.

8.5 Recette
Après l’installation et la Mise en service des équipements proposés, leur recette peut alors débuter. La
recette a pour but d’amener les équipements dans un état opérationnel et prêt à fonctionner. Cela inclut
la programmation, la configuration et les tests unitaires des équipements.

La recette est assurée par le personnel d’Alcatel-Lucent. Les activités sont :

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 30/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
 Vérification du câblage des équipements proposés,
 Configuration des cartes réseau (inclus le téléchargement des logiciels),
 Configuration du bâti sur le gestionnaire de réseau,
 Création des cartes de ligne sur le gestionnaire de réseau,
 Tests fonctionnels de bout en bout sur les cartes de ligne (1 ligne est testée par carte de ligne –
carte LT),
 Tests de recette,
 Rédaction du rapport de recette.

Le rapport de recette est signé conjointement par Alcatel-Lucent et TUNISIE TELECOM dans le cas où
aucun problème n’aurait été détecté. TUNISIE TELECOM reçoit une copie de ce rapport.

8.6 Mise en Y (dans le cas de Swap SR ou central)


Avec la prestation de Mise en Y et de swap de SR et central, TUNISIE TELECOM cherche à migrer les
équipements d’accès obsolètes vers les MSANs proposés dans la présente consultation.

TUNISIE TELECOM pourra bénéficier de la grande expérience d’Alcatel-Lucent dans les réseaux fixes
« Legacy » ainsi que les réseaux de nouvelle génération ; cela garantira à TUNISIE TELECOM une maîtrise
dans les opérations de migration.

Ci-après sont listées les différentes étapes :


Pré-requis :
- réunion de lancement entre TUNISIE TELECOM et Alcatel-Lucent dans le but de définir la
stratégie de basculement.
- fourniture par TUNISIE TELECOM de la base de données des abonnés raccordés aux MDFs ou SR

A l’issue de cette phase, un ensemble de documents (document de stratégie de migration, de process de


migration) sera rédigé et servira de référence pour la suite des opérations.

8.6.1 Cas d’un central (configuration Indoor)


Phase préparatoire :
Alcatel-Lucent réalisera :
- un sonnage au niveau des MDFs ainsi que la vérification de la continuité de chaque ligne
d’abonné à basculer (ainsi que la mise à jour de la base de données fournie par TUNISIE
TELECOM)
- la mise à jour de la base de donées
- la mise en Y des abonnés à basculer

TUNISIE TELECOM devra :


- Préconfigurer le softswitch et les MSANs pour les abonnés à basculer,
- Fournir les données de configuration des abonnés à basculer (selon le format à établir lors de
la réunion de lancement),

Opérations de Swap :
Alcatel-Lucent réalisera :
- L’isolation coté legacy des abonnés à basculer au niveau des Y installés précédemment

TUNISIE TELECOM devra :


- informer ces abonnés d’éventuelles perturbations
- Désactiver les abonnés à basculer sur les Switchs Legacy
- Activer les abonnés à basculer sur les MSANs et le Softswitch
- S’assurer du bon routage dans le réseau IP

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 31/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
Opérations post-swap (après une période d’observation par TUNISIE TELECOM) :
Alcatel-Lucent réalisera :
- Le décâblage des abonnés legacy basculés précédemment (au niveau de la mise en Y entre le
coté vertical et horizental du MDF)

8.6.2 Cas d’un SR (configuration Outdoor)


Phase préparatoire :
Alcatel-Lucent réalisera :
- un sonnage au niveau du SR (ainsi que la mise à jour de la base de données fournie par TUNISIE
TELECOM)
- la mise à jour de la base de donées
- Au niveau de la chambre existante du SR, réalisation d’un manchon sur le câble de distribution
et la mise en Y des abonnés à basculer à l’aide de connecteurs. Tunisie Telecom se chargera
de la fourniture des manchons, connecteurs et câble de passe entre la chambre existante et le
cabinet Outdoor
- Fermeture provisoire du manchon
- Au niveau du MDF coté cabinet Outdoor : raccordement du câble de passe coté vertical

TUNISIE TELECOM devra :


- Préconfigurer le softswitch et les MSANs pour les abonnés à basculer,
- Fournir les données de configuration des abonnés à basculer (selon le format à établir lors de
la réunion de lancement),

Opérations de Swap :
Alcatel-Lucent réalisera :
- L’isolation coté legacy des abonnés à basculer

TUNISIE TELECOM devra :


- informer ces abonnés d’éventuelles perturbations
- Désactiver les abonnés à basculer sur les Switchs Legacy
- Activer les abonnés à basculer sur les MSANs et le Softswitch
- S’assurer du bon routage dans le réseau IP

Opérations post-swap (après une période d’observation par TUNISIE TELECOM) :


Alcatel-Lucent réalisera :
- Le débranchement et le démontage de l’ancien câble de distribution entre la chambre
existante et le SR
- Fermeture définitive du manchon

8.6.3 Périmètre POTS & ISDN-BRA


Notre offre comprend le basculement des abonnés POTS et ISDN-BRA pour les quantités mentionnées dans
le BOQ. Dans le cas où d’autres technologies d’accès devront être basculées (xDSL entre autre), Alcatel-
Lucent proposera une offre complémentaire.

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 32/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.
9 CALENDRIER D’EXECUTION

9.1 Délai de livraison


Le délai de livraison proposé est de 3 mois après l’entrée en vigueur de chaque commande (le lieu de
livraison est un entrepôt de Tunisie Telecom).

9.2 Calendrier de déploiement


Après l’entrée en vigueur de chaque commande, une réunion de lancement de projet sera organisée entre
Alcatel-Lucent et Tunisie Telecom, durant laquelle le calendrier du déploiement sera discuté.

Fin du Document

Fourniture, Instatallation et Mise en Description technique & services MSAN - Mars2015 Page 33/33
Service de MSAN – Mars 2015

All rights reserved. Passing on and copying of this document, use and communication of its content is not permitted without written authorisation.

Вам также может понравиться