Вы находитесь на странице: 1из 1

1 2 3 4 5 6

50000

10000 10000 10000 10000 10000

BASE TYPE A BASE TYPE A BASE TYPE A BASE TYPE A BASE TYPE A BASE TYPE A
2300x2300x400Dp 2300x2300x400Dp 2300x2300x400Dp 2300x2300x400Dp 2300x2300x400Dp 2300x2300x400Dp

1
1

1
BASE BASE BASE BASE BASE BASE

C0

C0
C0

C0

C0

C0
A
7300

2300
1150 1150

BASE TYPE A BASE TYPE A BASE TYPE A BASE TYPE A BASE TYPE A BASE TYPE A
2300x2300x400Dp 2300x2300x400Dp 2300x2300x400Dp 2300x2300x400Dp 2300x2300x400Dp 2300x2300x400Dp
BASE BASE BASE BASE BASE BASE

1150
2

2
2

2
C0

C0
C0

C0

C0

C0
2300
B COLUMN DIMENSIONS:

1150
A A COLUMN DIMENSIONS
C01 500x500x4600
C02 500x500x1800

FOUNDATION LAYOUT
SCALE 1:75

No BARS TOTAL BENDING


MEMBER PER DIA LENGTH NUM- MARK SC
OF MEMB BER A B C D E/r

N.G.L
600

1000
400

1150 1150

2300

SECTION A-A
SCALE 1:20

8 10 12 16 20 25 32 40 TOT Date
R Det by
Y Ref Dwg
TOT Job No

Revision

Schedule No

REFERENCE DRAWINGS APPROVER: Q.M.S CHECKING SYSTEM No. 11 MALOKIBA INDUSTRIAL PARK
Scale.
NAME: 1 BRUNEL ROAD
DRAWN BY: N MALINDISA EVANDER, MPUMALANGA
Drawing no.
Pr. No. 2280 PROPOSED SPORTSFIELD
DRAWING CHECK: M WAYITI R19012-PMB-STR-001
P.O. Box 3211
For: ROBUST CONSULTING SECUNDA GRAND STAND & LIGHTING POST
DRAWING REVIEW: F KAMBA Client drawing no.
Revisions

ENGINEERS (PTY) LTD 2302


FOUNDATION LAYOUT
Sign: DESIGN ENG.: F KAMBA Tell: 086 117 7726
A1 2019/04/01 ISSUED FOR INFORMATION NM Fax: 086 535 3817 PLANS & SECTION DETAILS
Date:
No. Date Description Initial
DESIGN REVIEW: M WAYITI E-mail: info@robustengineers.co.za Revision No. A1

Вам также может понравиться