Calibration certificate Model: EARTH INSULATION TESTER Date: 18.12.2017 Serial No.: 17470366 Pentaumagpy Korres: Petkovéek Signature: Date Placed in Service:_--_______ ue Date: Matrel Recommended Cal Interval: 12 months Metre Fe date may be established (by the customer) by adcing the “Recommended Cal Interval” tothe "Date Placed In Service.” No. Function /Ubat=5,5V_____|_Input_|_Low limit _ Reading [Uncertainty [High limit 1 Outloo ication, KeyS.rotary switch, buzzer oxime 7 2 Low ohm 2200 0,002 0002 0,00 0.01 0.028 een 4,002 ose 1,00 0,01 1,049 19,008 18602 18,79 ott 19,402 19000 13432 1890 1 19570 Continuity _ oe OK 3 Clamp Current 0,0mA oma OT of 0.3mA 10mA g2mA 99 ot 10,8 mA joomA 95,0 99,3 1 4105 mA 4A 950mA 998 001 1.05.8 108 950A 9,99 os 105A Eee Lie eA 99,9} OA 4 Test > 0a 1 10V Utest 510 kD 4 545. V - 7 900 ka 8955 BA insulation resistance / Un=80V 0.000M8 0,001 0,003Ma Riso 1,000M2 0,009 1,053M2_ 190M 13 198,6Mo Uiso outpul) 10M0 SV aa 65 52 Ingulation resistance / Un =250V 0.100 M0 0,001 0,104M Riso ye.00Ma ——18,60M2_——19,06 0.12 12.400 490,0Ma —*186,0M2._—*188,8 42 194,.0Ma mag 195 or 8G 53 Insulation resistance / UN=1000V 1008 98,9 06 102,2Ma Riso 1.9069 1,88 003 1.97602 20,062 19,7 03 46a Uiso output) 10M 1050 1048 7 1100 Short circuit current 2,51 3,0mA 6 Voltage AG/ DC 0 2v ee 551 8 7 Earth resistance 0,01 0.01 0.030 four - lead method. 0950 1,01 0,01 1,052 49592 — 189,8 A 194,19 soot eee 70h 0.0 eo 4900Ka —*18,05k2 19,35 O11 19,95 k2 Probe influence Re. Rpmax __1.00% __ Geeta 0d eee 8 Earth resistance 1 clamp 49,008 jas92 18,90 ot 19410 eR nitee eT o0neeee 20.01 @ Earth resistance 2 clamp 1,008 0932 1,00 0.01 1,070 at foamy 18018. __ 18.58 028 18,970 40 S232 por header — _ OK — ‘All results in accordance with technical specification. Reference instruments: No. lnstrument Type Cerificate No. Due 1 Calbaton System 19100, Wavetek 7c01256 91.72018 20750577 METREL dd Tel: (+386 1) 7558 200 “% METREL’ tenet 2 ela HORJUL — hittp://aww.metrel.si oe mara @metrel.s! Metrel Certificate of Calibration Practices The Metrel Quality System is certified by BVQI according to Quality standard ISO 9001 : 2008, Certificate No. SL21120Q. The Metre! hereby certifies that the above instrument was calibrated in accordance with applicable Metrel calibration procedures during the manufacturing process. These processes are ISO 9001 controlled and are designed to assure that the instrument will meet its published specification. The Metrel further certifies that the measurement standards and instruments used during the calibration of this instrument are traceable to the (inter)national standards. The policies and procedures at this facility comply with EN ISO/IEC 17025. Environmental conditions: Temperature: 23 °C 4 5 °C Relative humidity: 10 % to 75 % Calibration Procedure: “Name of Model / Type" Uncertainty: The reported expanded uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by coverage factor k = 2, which for a nominal distribution corresponds to a coverage probability of approximately 95%. The standard uncertainty of measurement has been determined in accordance with EA Publication EA-4/02 Td, “=O bole fore Edo Reven Janko Mole Chief Executive Officer Head of Calibration Laboratory

Вам также может понравиться