13 calibration

"Kal. -data torque "

Figure: Calibration data for the torque sensor

- Calibration is carried out with the value of the force sensor already converted to the torque
(force * lever arm)

- the number Indicates the identification of the type and position of the sensor

- the nominal value indicates the nominal value of the sensor

- meter: and offset: are the calibration data for the sensor correction

- in the lower part of the LCD display symbols are displayed, which are assigned to the
functions:

Save Stores the calibration data permanently and activates the sensor correction

Measurement. Current reading of the sensor is displayed Goes back to entering the calibration
data

Go to the previous sensor (if available)

Go to the next sensor (if available)

- If the changes have been made, these should be saved with the function key (F1). To exit
the calibration page, please press the arrow key upwards

- the calibration data for the other sensors can be adjusted in the same way.
14 Date / time

Illustration: change of date and time

- Use the arrow keys to toggle between the individual entries such as day / month / year /
hour / minute / second
- press the () button to activate the field to be edited and enter your values with the function
buttons F1, ..., F10
- if the changes have been made, save with the function key (F1) and leave the date / time by
pressing the arrow key upwards

15 parameters

Figure: change the parameters The following parameters can be changed

- torque controller Kp 16 system

- The system menu is divided into six sections with five chapters

- the function keys are used to navigate the setup icons below:

- runtime () neurstart the operating software

- language () change of languages german / english

- systeminfo () additional information about the HMI hardware

- Project info () Additional information about the HMI software

- back () goes back to the service menu

Figure: system menu icons

17 users

- The system administrator can change the function configurations or make system settings
for the device.

- the administrator can specify different access permissions for the device.

- if necessary, the administrator can change the password for the service menu.

18 cleaning, care
- The fully automated laboratory airborne probe is a high-precision test instrument. Each
precision unit should be serviced by a service technician and possibly adjusted every year.
This prevents long-term damage to the device and misalignments on the measuring sensors.
A wear on components is thus detected in good time. Appropriate maintenance contracts with
a test report are offered.

- after each use of the appliance, a thorough cleaning should be carried out. Dust deposits and
residual material must be removed from the appliance.

- no abrasive or aggressive agents may be used to clean the keyboard inside the housing parts.

- special care must be taken when cleaning the threaded bolts and threaded holes, otherwise
damage will be expected when the handles and nuts are tightened.

- We recommend a regular maintenance and control of the adjustment by our service.

19 spare parts list

The following parts can be reordered at APS GmbH at any time.

Item No item Description Lining with clamping screw Extener optional torque sensor
Tensioning device for sample containers (or parts thereof) power cable Ethernet cable
Bedeinungsanleitungen For all other spare parts and spare parts please contact the service of
APS antriebs-, pruf and steuertechbik GmbH.

20 FAQ

effect

KP 300 - display does not light up after switching on

Engine does not start

Moment display is negative

Cause / remedy

Check device fuses on mains connector

Check moment, exceed maximum moment? possibly the transgression can only be one-sided,
with the total moment in the permissible range. Or electronics problem - let the service be
checked.

Check calibration data (offset) bvw. Negative direction was chosen

21 assurance
We provide 6 months warranty on construction and material defects of the automatic
laboratory airborne probe and its construction targets. Wear parts are generally excluded from
warranty claims. The warranty claim begins on the day the goods are properly delivered,
regardless of whether it has been used or not. Deviating claims require the written consent of
the APS antrebs-, pruf and control GmbH. In the event of improper or grossly negligent
handling of the automatic laboratory airborne probe or failure to observe the instructions in
these operating instructions, we can not assume any liability. The opening of the laboratory
airborne probe is only permitted by an employee of APS GmbH or a person authorized by
APS GmbH. Otherwise, any warranty of the tester expires. We reserve the right to make
technical changes to the components of the automatic laboratory airborne probe. This manual
has been prepared with great care and to the best of our knowledge and conscience. Since
mistakes can never be completely avoided despite all efforts, we can not accept any liability
for incorrect information and its consequences. Our general business conditions apply. For
hints and suggestions for improvement, we are always grateful.