Вы находитесь на странице: 1из 10

SINGLY AND DOUBLY REINFORCED BEAM

Width of beam (B)(Input) 250


Depth of beam (D)(Input) 350
Span of the beam (L)(Input) 3500
exposure(Input) moderate
clear cover 30
Effective Depth 314
Fck(Input) 30
Fy(Input) 415
Mu(Input) 37008000
L/d ratio 10
deflection check TRUE
As, min 179.2168674699
As,max 3500
Dia. Of reinforcement(Input) 12
Xu,max/d 0.48
Mu,lim 126753984
Ast reqd 308.0045280933
Ast to be provided 308.0045280933
Area of bar 113.1428571429
Number of bars 3
Ast provided 339.4285714286

CHECK FOR SHEAR STRESS


V(Input) 49380
Shear Stress 0.5643428571
Percentage of reinforcement 0.4323930846
Max Shear Stress(Input) 0.37988
Check for shear stress Prvide shear reinforcement
grade of shear reinforcement(Inp 250
dia of shear reinforcement(Input) 10
Number of Legs(Input) 2
Asv 78.5714285714
shear reinf spacing 567.36
Sv,max1 235.5
Sv,max2 300
Sv final 235.5
shear reinf spacing final 235.5
Es(Input) 200000
Doubly Reinforced
Compression Moment NA
Fsc 560.6687898089
Check for Fsc 361.05
Asc -6904.7057194294
total ast -6565.2771480009
EINFORCED BEAM

mm
mm
mm

mm
mm

N-mm

mm^2
mm^2
mm

design singly reinforced


value is safe

mm^2

mm

mm^2
mm
mm^2
mm^2
mm^2
mm^2
mm^2
SLAB DESIGN ACC. TO IS 456: 2000
INPUTS
Lx(Input) 3500 mm
Ly(Input) 4000 mm
Exposure(Input) mild
clear cover 20 mm
Ly/Lx 1.1428571429 Provide two way slab
Depth of slab(Input) 150 mm
Effective Depth 130 mm
Fck(Input) 30
Fy(Input) 500
effective Span 3630 mm
Dia of bar(Input) 16
LOAD CALCULATION
Self weight of slab 3.25 kn/mm^2
Live load on slab(Input) 2 kn/mm^2
Floor finish(Input) 1 kn/mm^2
Total load 6.25 kn/mm^2
Ultimate load 9.375 kn/mm^2
Design moment and shear forces
αx(Input) 0.055
αy(Input) 0.047
Mu,x 6.31640625 Kn/m
Mu,y 7.05 kn/m
Vux 16.40625 kn
CHECK FOR DEPTH
Depth(d) 41.2661913765 suffiecint depth
Ast min 156 mm^2
Ast reqd, min 126.7918159741 mm^2
Ast reqd,max 7673.2081840259 mm^2
ast final smaler moment 113.4004783315 mm^2
ast final larger moment 7686.5995216685 mm^2
AST final 113.4004783315 mm^2
Check for shear stress
shear stress 0.1262019231
percentage of reinf 5.9127688628
k(Input) 1.3
Tc(Input) 0.29
max shear stress (k*Tc) 0.377
Torsional Reinforcement
Area of torsional reinf 95.0938619806 mm^2
Dist over which reinf is 800 mm
Egde Strip Reinfocement
Ar. Of reinf 156 mm^2
a= 217500
b= -1696500000
c= 2.115E+11
COLUMN DESIGN (Biaxial Bending)
INPUTS
For Major axis (X)
Width of column (B)(Input) 450 mm
Depth of column (D)(Input) 450 mm
Mux(Input) 53790700 Nmm
Muy(Input) 43445300 Nmm
Pu(Input) 875888 N
Diameter of bar (Input) 20
Exposure(Input) moderate
clear cover 30 mm
Effective cover (d') 50 mm
d'/D 0.1111111111
Pt (%)(Input) 1 (assumed)
As, reqd 2025 mm^2
Number of bars 7
Pt, provided 1.0864197531 mm^2
Pt(provided) /fck 0.0362139918
𝑃�/(𝐹𝑐𝑘∗𝑏∗𝑑)
0.1441790947
𝑀��1/(𝐹𝑐𝑘∗𝑏∗𝐷 ∗𝐷)
(Input) 0.09

Mux1 246037500

Area of bar 314.2857142857


Ast provided 2200
For Minor Axis (Y)
Width of column (B)(Input) 450 mm
Depth of column (D)(Input) 450 mm
Pu(Input) 875888 N
Diameter of bar (Input) 20 area of bar
clear cover 30 mm

Effective cover (d') 50 mm


d'/D
𝑀��1/(𝐹𝑐𝑘∗𝑏∗𝐷 ∗𝐷) 0.1111111111
(Input) 0.09
Muy1 246037500
Puz(design load on column) 2733750
Pu/Puz 0.3203979881

αn(Input) 0.6
(Mux/Mux1)^αn+(Muy/Mux)^αn<=1 design is safe
Fck(Input) 30
Fy(Input) 415

Tie Reinforcement
tie dia(Input) 8 mm
Check for dia tie dia is ok mm
final dia 8 mm
Spacing 300 mm
reinforcement comment provide 8 at spacing 300