Вы находитесь на странице: 1из 2

BD-700 AIRCRAFT MAINTENANCE MANUAL - PART I

OXYGEN

Introduction

The oxygen system supplies oxygen to the flight crew and the
passengers during an emergency.

General Description

Refer to Figure 1.

The oxygen system supplies oxygen to the flight crew and passengers
during cabin depressurization, smoke contamination, or other
emergencies. Four oxygen storage cylinders supply oxygen to the
flight crew and the passengers. The oxygen is breathed through the
quick donning pressure demand-type face-masks, with mask mounted
regulators. The oxygen system is filled through a ground servicing
panel at the nose of the aircraft on the left hand side.

EFFECTIVITY: ALL
35-00-00 Page 1
Dec 12/2003
BD-700 AIRCRAFT MAINTENANCE MANUAL - PART I

STORAGE
GROUND CYLINDERS
SERVICE−PANEL OVERBOARD
PRESSURE−GAUGE DISCHARGE
INDICATOR
FILLER VALVE

GROUND
SERVICE PANEL

STORAGE CYLINDER
PRESSURE− GAUGE

REGULATOR

PRESSURE
SWITCH
PRESSURE
TRANSDUCER LEGEND

CHECK VALVE Cockpit/cabin supply line


Storage−cylinder fill line

GSD3500000_001
HP Discharge line
ALTIMETRIC VALVE LP Discharge line

TO EICAS TO EICAS HP Capillary lines for indication


CABIN OXYGEN
SUPPLY− LINE PILOT/COPILOT
STOWAGE BOXES AND
CREW OXYGEN MASKS

Oxygen System - Schematic


Figure 1

EFFECTIVITY: ALL
35-00-00 Page 2
Jan 18/2005

Вам также может понравиться