The number of trigger events is limited only by the available tool memory
(up to 8 megabytes). For example, the standard tool can record 10 days
of standard data at 2 sec/sample with an additional 10 trigger events
recording up to 5 seconds of ultra fast data (40,000 samples/sec) per
event.
Applications
Well stimulation
Perforating (Dynamic/Static underbalance monitoring or perforation efficiency
Fracturing
Reservoir Monitoring
Well Testing
Standard Pressure / Temperature surveys
High operating pressure and temperature Reduces power consumption and battery cost.
Ensures no data loss in the event of battery disconnection, depletion or premature failure. Allows multiple transient events
Very large Non-Volatile Flash memory
to be recorded in a single run.
Probe Aberdeen Technical Centre • Unit 9, Energy Development Centre, Aberdeen Energy Park • Claymore Drive, Bridge of Don •
Aberdeen, AB23 8GD • UK • T +44 1224 708470 • F +44 1224 824957 • www.probe1.com
Rev 1.1 Feb 2015
IntelleX™
Ultra-Fast Pressure Gauge (25kpsi)
SEN-0010-0120
Specifications
Outside Diameter 1.29 in (32.7 mm)
Length (Standard) 21.6 in (0.55 m)
Weight 5 lbs (2.26 Kgs)
Housing 17-4PH (Standard) or NACE MR-01-75 Compatible
Standard: 25,000 psi (172MPa)
Pressure Stability: ± 0.3% FS per 3 months
Resolution: 0.01 psi @ 10,000 psi & 1 sample/sec or 0.15 psi @ 10,000 psi & 40,000 samples/sec
Accuracy: ± 0.05% FS <150°C, ± 0.05% FS <150°C and ± 0.10% FS < 175°C
2 X ‘AA’ Lithium Batteries, 1.4 Ahr, 6-8 Vdc, 180°C (optional 200°C battery available, 1.1 Ahr)
Power (>20 days operations from a single battery @ 1 second)
(>2 days operation from a single battery @ 40k)
Probe Aberdeen Technical Centre • Unit 9, Energy Development Centre, Aberdeen Energy Park • Claymore Drive, Bridge of Don •
Aberdeen, AB23 8GD • UK • T +44 1224 708470 • F +44 1224 824957 • www.probe1.com
Rev 1.1 Feb 2015