KB12180 12V 18Ah(20hr) - LONG LIFE

The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid electrolyte
is absorbed by separators and plates and thus immobilized. Should the battery be
accidentally overcharged producing hydrogen and oxygen, special one-way valves allow the
gases to escape thus avoiding excessive pressure build-up. Otherwise, the battery is
completely sealed and is, therefore, maintenance-free, leak proof and usable in any position.

Battery Construction
Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte
Raw material Lead dioxide Lead ABS ABS Rubber Copper Fiberglass Sulfuric acid

General Features Performance Characteristics


● Absorbent Glass Mat (AGM) technology Nominal Voltage 12V
for efficient gas recombination of up to Number of cell 6
99% and freedom from electrolyte
Design Life 10 years
maintenance or water adding.
● Not restricted for air transport-complies Nominal Capacity 77oF(25oC)
with IATA/ICAO Special Provision A67. 20 hour rate (0.90A, 10.5V) 18Ah
● UL-recognized component. 10 hour rate (1.78A, 10.5V) 17.8Ah
● Can be mounted in any orientation. 5 hour rate (3.19A, 10.5V) 15.95Ah
● Computer designed lead, calcium tin alloy 1 hour rate (12.7A, 9.6V) 12.7Ah
grid for high power density. Internal Resistance
● Long service life, float or cyclic Fully Charged battery 77oF(25oC) 16mOhms
applications. Self-Discharge
● Maintenance-free operation. 3% of capacity declined per month at 20oC(average)
● Low self discharge.
Operating Temperature Range
Discharge -20~60oC
Dimensions and Weight Charge -10~60oC
Storage -20~60oC
Length(mm / inch) 181 / 7.13 o o
Max. Discharge Current 77 F(25 C) 225A(5s)
Width(mm / inch) 77 / 3.03
Height(mm / inch) 167 / 6.57 Short Circuit Current 850A
Total Height(mm / inch) 167 / 6.57 Charge Methods: Constant Voltage Charge 77oF(25oC)
Approx. Weight(Kg / lbs) 5.5 / 12.1 Cycle use 2.30-2.35VPC
Maximum charging current 6.8A
Temperature compensation -30mV/oC
Standby use 2.23-2.27VPC
Temperature compensation -20mV/oC

Discharge Constant Current (Amperes at 77oF25oC)


End Point
5min 10min 15min 30min 1h 3h 5h 10h 20h
Volts/Cell
1.60V 70.9 48.0 38.1 21.2 12.7 4.85 3.38 1.88 0.96
1.65V 68.7 46.8 37.2 20.7 12.4 4.77 3.31 1.85 0.95
1.70V 66.3 45.6 36.2 20.2 12.3 4.69 3.25 1.82 0.94
1.75V 63.6 44.4 35.3 19.7 12.1 4.61 3.19 1.78 0.90
1.80V 60.8 43.2 34.3 19.3 11.9 4.53 3.10 1.75 0.89
Discharge Constant Power (Watts at 77oF25oC)
End Point
5min 10min 15min 30min 1h 3h 5h 10h
Volts/Cell
1.60V 135 86.1 69.3 39.4 24.1 9.3 6.28 3.58
1.65V 131 84.6 68.1 38.9 23.9 9.2 6.21 3.54
1.70V 126 83.2 67.0 38.3 23.6 9.1 6.13 3.51
1.75V 122 81.7 65.8 37.7 23.4 9.1 6.05 3.47
1.80V 117 80.2 64.6 37.2 23.2 9.0 6.04 3.43
(Note)The above characteristics data are average values obtained within
three charge/discharge cycles not the mimimum values.

page1 of 2
KB12180 12V18Ah - LONG LIFE

Discharge characteristic (25 C)


O

Charged

Voltage
Current
Volume
Constant voltage charging
characteristic (0.25CA,25 C)
o

13.0
(%) (XCA) (V)
12.0
140

120 0.25
15.0
Voltage(v)

11.0 Charged Volume


100 0.20
10.0
14.0 Charge Voltage
80
0.15
13.0
9.0 60
0.10
40 12.0
8.0
20 0.05
11.0 Charging Current
0
0 1 2 3 5 10 20 30 60 2 3 5 10 20 30 0 0
min h 0 2 4 6 8 10 12 14 16 18 20
Discharge time Charging time (hours)

Relationship between
Self-discharge characteristic
charging voltage and temperature
110

100
15.6
90

Capacity(%)
C y c le
Voltage(V)

15.0 Use
80
14.4
70
S ta n d
13.8 by Use
60 o o o
C C C
13.2 50

40
-10 0 10 20 30 40 50 60 0 2 4 6 8 10 12 14 16 18 20
Ambient temperature( oC) Storage time: months

Cycle service life in relation to


Life characteristics of Standby use
120 depth of discharge
120

100
100
Capacity(%)
Capacity(%)

80
80

60 60
Testing conditions:floating voltage:2.27 to 2.30V Cell 100% D.O.D. 50% D.O.D. 30% Depth of discharge
ambient temperature: 25 oC(77 oF)
40 40

20 20

0 200 400 600 800 1000 1200 1400


0 1 2 3
Life(year) Number of cycles(cycles)

Temperature effects on float life Temperature effects on capacity


10
120

100
C
0 .0 5
Life(years)

0 .1 C
Capacity (%)

80
2.30V Cell 0 . 2 C
1 60
1 .0 C
40
2 .0 C
3 .0 C
20

0.1 0
10 20 30 40 50 60
-20 -10 0 10 20 30 40 50( oC)
Temperature( oC)

THE INTERNATIONAL CERTIFICATION NETWORK