COMPLETION REPORT

Post Installation

Solar DWS System in Lower


Kurram(FXKI 006)
Table of Contents

1. General Information ................................................................................................................................................ 1


2. Post Installation Completion Verification ........................................................................................................... 1
2.1 Solar Panels .......................................................................................................................................................... 1
2.2 Structure for Solar Panel Mounting ............................................................................................................... 1
2.3 Fencing of Solar System .................................................................................................................................... 1
2.4 Water Pipe ........................................................................................................................................................... 1
2.5 Water Pump ........................................................................................................................................................ 2
2.7 Pump Inverter...................................................................................................................................................... 2
2.8 Cables .................................................................................................................................................................... 2
2.11 Earthing ............................................................................................................................................................... 2
2.13 Others................................................................................................................................................................. 2
2.14 Measured Data.................................................................................................................................................. 2
3. General Remarks ...................................................................................................................................................... 3
4. Pictorial Observations On-site .............................................................................................................................. 4
4.1 Foundation ........................................................................................................................................................ 4
4.2 Str111ucture ..................................................................................................................................................... 5
4.3 PV modules ....................................................................................................................................................... 5
4.4 Pump Inverter .................................................................................................................................................. 6
4.5 Pump / bore output ........................................................................................................................................ 7
4.6 Water Discharge ............................................................................................................................................. 7
4.7 Fencing ............................................................................................................................................................... 8
4.8 Earthing .............................................................................................................................................................. 9
4.9 Cables and Wiring ........................................................................................................................................... 9
4.10 Combiner Box................................................................................................................................................ 10

i
1. General Information
Contract FDPGC/CONS.001/2018 Name Of FATA Development Program
Agreement Ref No Client Government to Community
(FDPGC)
Grant No FXKI 006 Type Solar DWS System

Engineer In
Location Lower Kurram Engr. Tallal Ahmed
charge

Sub
Date Of Visit 05-12-2018 M. Kamran
Engineer
Focal
Contractor Solar Tech Mr Habib
Person
1. PV Analyzer
2. Solar Irradiance Meter
Testing
Type of Document 3. DMM
Approval Report Equipment
Provide by Client 4. Ultra-Sonic Water Level Meter
Used
5. Ultrasonic Water Flow Meter
6. Elcometer

2. Post Installation Completion Verification

2.1 Solar Panels


Solar Panels
Sr. Type Brand Module Qty. Total PV. Observations
Name PV Watt Watt
Mono
Crystalline Tested with PV analyzer,
1 AIDUO 280 76 21280
DMM, results are satisfactory.
(A-grade)

2.2 Structure for Solar Panel Mounting


Structure for Solar Panel Mounting
Sr. Type of material Structures Visual Conditions Observations
1 Angle Iron 25 sets of 3 modules Ok Satisfactory
3 sets of 4 modules
2 Foundations PCC OK Satisfactory

2.3 Fencing of Solar System


Fencing of Solar System
Sr. Type of material Causing shade on PV module? Visual Conditions Observations
1 Solid Iron Bar 6 mm“ No Ok Satisfactory
edged trimmed

2.4 Water Pipe


Water Pipe
Sr. Type Out Put Diameter Length Observations
1 Metal Pipe 3 inch ~100ft Satisfactory
(MS)

1|Page
2.5 Water Pump
Water Pump
Sr. Type Model Capacity Brand Observations
1 Solar Kps6/30/12 17 Hp Komax As per BOQ for motor compatible,
compatible found genuine and operational.

2.7 Pump Inverter


Pump Controller/ Inverter
Sr. Type Brand, Model Capacity Observations
1 Solar Compatible JNTECH, 18.5 kW As per BOQ for pump motor compatible,
JNP18K5H found genuine & working properly.

2.8 Cables
Cables (For Solar Pumping Solution)
Sr. Area Core Quantity Observations
1 16mm 1 core Job completed PV J-Box to PV J-Box
Satisfactory
2 25mm 1 core Job completed PV Arrays to Combiner Box and further to Inverter,
Satisfactory
3 25mm 3 Core Job completed From inverter to submersible pump
Satisfactory

2.11 Earthing
Earthing
Sr. PV & Mounting Inverter Pump Structure SPD Observations
1 OK OK NO OK NA OK

2.13 Others
Others (if any)
Sr. Description Specification/ Functionality Remarks Observations
NA NA NA NA

2.14 Measured Data


Measured Data
Solar Irradiance Water PV Watts (volts Water depth Inverter Data Remarks
at the time of flow (g / & Ampere) from Bore
visit hour) Top
550 (cloudy) 617 VDC OK
1800
7A

2|Page
3. General Remarks

• Over-all quality of necessary equipment's & pump output is satisfactory. Capping


is required for the earthling cable

3|Page
4. Pictorial Observations On-site
4.1 Foundation

4|Page
4.2 Str111ucture

4.3 PV modules

5|Page
4.4 Pump Inverter

6|Page
4.5 Pump / bore output

4.6 Water Discharge

7|Page
4.7 Fencing

8|Page
4.8 Earthing

4.9 Cables and Wiring

9|Page
4.10 Combiner Box

10 | P a g e