Вы находитесь на странице: 1из 1

PLUMBING NOTES:

1. ALL PLUMBING WORKS SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL

2.
PLUMBING CODE OF THE PHILIPPINES AND LOCAL REGULATIONS AND ORDINANCES.
THE PLUMBING CONTRACTOR SHALL LOCATE AND DETERMINE THE ACTUAL LOCATIONS
MISCELLANEOUS DETAILS
OF EXISTING SANITARY FACILITIES TO CONFIRM WITH THE PROPOSED DESIGN.
3. ALL PIPES SHALL BE INSTALLED AS INDICATED IN THE WORKING DRAWINGS. ANY RELOCATION
REQUIRED FOR PROPER EXECUTION OF OTHER TRADES SHALL BE UPON THE APPROVAL
OF THE SANITARY ENGINEER.
%) SLOPE. NOTES :
4. ALL PIPES PASSING THROUGH WALLS BE PROVIDED WITH SLEEVES. ANGULAR SPACE BETWEEN GRADE WATERPROOF MEMBRANE IS NOT REQUIRED IN SLAB ON GRADE.
ANGELES PIPE AND SLEEVE SHALL BE FILED WITH COAL TAR, ASPHALTIC COMPOUND OR ANY OTHER MATERIAL 10,000mm SQ. MIN. (TYP.)
1.NEOPRENE RUBBER GASKET COMPRESSION TYPE JOINT.
12mm
FOUND EQUALLY APPROVED. 2.DRAINS SHALL BE CONNECTED TO CAST P-TRAP.
3.DRAIN SHALL HAVE A CAST IRON BODY AND SEEPAGE AND A CHROMIUM
5. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS.

100
4.PLATED BRONZE, NICKEL BRONZE OR NICKEL BRASS STRAINER.
6. PROVIDE CONTROL VALVE FOR EACH GROUP OF FIXTURES.
7. UNLESS OTHERWISE SPECIFIED, ALL PLUMBING FIXTURES SHALL BE PROPERLY VENTED, MAXIMUM COUNTER SUNK CONCRETE
A FINISH/TILE FLOOR
COLLAR
SANTA DISTANCE OF VENTILATION FROM FIXTURE SHALL BE 1.50METERS MEASURED ALONG THE LENGTH OF PIPE. PLUG (BRASS)
EPOXY SEALANT
MEXICO ANA 8. ALL HORIZONTAL WASTE PIPING (75ØMM) AND SMALLER SHALL BE LAID WITH A MINIMUM SLOPE OF (ALL AROUND) CEMENT
OUTLET SIZE(mm) A FILL/BED
%) PERCENT AND 100mm AND LARGER PIPES SHALL HAVE ONE PERCENT (1 Y-BRANCH 50 125
9. ALL FIXTURES OR GROUP OF FIXTURES SHALL BE EQUIPPED WITH INDIVIDUAL AIR CHAMBER 1/8 BEND 75 200
100 250 STRUCTURAL
10. SWEEP QUARTER BEND. ONE EIGHT BENDS WHEN THE CHANGE OF FLOW IS FROM HORIZONTAL TO VERTICAL SEWAGE/WASTE SLAB
PIPE
A SINGLE ONE EIGHT BEND COMBINATION MAY BE USED ONLY ON VENT PIPE. PLUG Y-BRANCH
11. NO DOUBLE HUB OR DOUBLE TEE BRANCH SHALL BE USED ON HORIZONTAL SOIL OR WASTE LINES. WHEN NOT THRU RUN WATERPROOF
SAN FERNANDO SM CITY 12. PROVIDE PIPE SLEEVES AT WALL, COLUMNS OR SLAB ONE SIZE BIGGER THAN THE ACTUAL LINES PASSING THROUGH WALL MEMBRANE
SEE NOTE 2 SEE NOTE 1
PAMPANGA COLUMN OR SLAB TO PROTECT FROM BEAKAGE.
13. CLEANOUTS ARE REQURIED UNDER THE FOLLOWING CONDITIONS :
A.) EVERY CHANGES IN HORIZONTAL DIRECTION
BACOLOR
B.) EVERY 15.00M IN HORIZONTAL LINE OF PIPE
NOTE : ESCUTCHEONS SHALL BE PROVIDED AT ALL FINISHED
C.) AT THE END OF ANY HORIZONTAL PIPE LINE SURFACES WHERE EXPOSED PIPING, BARE OR INSULATED
14. ENGINEER-IN-CHARGE TO VERIFY ACTUAL LOCATION AND ELEVATION OF STREET DRAINAGE AND STREET WATER SCORIATED COVER NEOPRENE GASKET PASSES THROUGH FLOORS OR CEILINGS, EXCEPT IN BOILER,
SEE NOTE 2 UTILITY OR EQUIPMENT ROOMS.
SANTA RITA MAINS FOR CONNECTION BEFORE CONSTRUCTION. FINISH FLOOR
INSULATION
15. PROVIDE GRAVEL BEDDING FOR CATCH BASIN AND TRENCH BOTTOM SLAB, AND SAND BACKFILL FOR ALL PVC PIPE
SEALANT METAL JACKET
AND CONCRETE PIPES FOR STORM AND SEWERAGE PIPES: REFER TO DETAILS OF BEDDING AND BACKFILLING TWO PIECE THREADED
ADJUSTABLE HOUSING METAL BAND (TYP)
BACK UP
MATERIAL SEALANT
WATER-PROOF MEMBRANE BACK UP MATERIAL
GUAGUA CEMENT (CLOSED CELL
FIN. FLOOR FLEXIBLE FOAM
Y-BRANCH
RUBBER OR PLASTIC)

PIPE
1/8 BEND
SEWAGE/WASTE
PIPE SLEEVE
PLUG Y-BRANCH
WHEN NOT THRU RUN
ESCUTCHEON SLEEVE
SPRING CLIP TYPE
VICINITY PLAN N NOTES : 1. WATER-PROOF MEMBRANE ARE NOT REQUIRED IN SLAB ON GRADE.
MIN. 8mm CLEARANCE

PIPE WITHOUT INSULATION PIPE WITH INSULATION


2. CHROMIUM-PLATED BRONZE, NICKEL BRONZE, NICKEL BRASS OR
STAINLESS STEEL FLUSH TYPE ACCESS COVER PLATE.

REDUCING TEE
SM CITY PAMPANGA
15mm HOSE BIBB
15mm FEMALE ADAPTER
UNION
MALE ADAPTER
SM CITY PAMPANGA A A B B

GATE VALVE
6505 mm

150 500 1100 700 505 300 700 350 700 350 700 450

JEEPNEY TERMINAL II 1
533 200

200
400 150
550
800

FOOD DISPLAY
OVER HEAD CABINET

350
3400 mm

3400 mm
3050

C DINING AREA C
1217

D
1300

D
COUNTER

MALE ADAPTER
150 500

300

2
150

W1 W2 D1

150250 1850 400 2015 140 1400 300

6505 mm

A B

FIN. FLOOR LINE


FIN. GRADE LINE

JOSE ABAD SANTOS AVENUE


PIPE SLEEVE THRU FLOOR
SEE DETAIL
FROM WATER METER
JOSE ABAD SANTOS AVENUE A A

6505 mm
B B
150 500 1100 700 505 300 700 350 700 350 700 450

OROTEL 1
533 200

200
400 150

PIPE SLEEVE THRU FOOTING


550

SF2 FLOOR CENTER


800

FOOD DISPLAY
OVER HEAD CABINET

MSE PAMPANGA
350
3400 mm

3400 mm

SEE DETAIL
3050

C DINING AREA C
1217

D D
1300

COUNTER
150 500

300

2
150

W1 W2 D1

150250 1850 400 2015 140 1400 300

6505 mm

A B

EAST GATE CENTER

HOTEL SOGO

SIDEWALK
SIDEWALK SIDEWALK

JOSE ABAD SANTOS AVENUE

LOCATION PLAN SITE DEVELOPMENT PLAN N


N
Note : These drawings as instruments MACS
of service, are the property and VICINITY MAP
documents of the Architect. It shall LOCATION PLAN
MAY 15, 2019
.\12.jpg J.A.R ARCHITECTURE AND DESIGN STUDIO
ENGINEER be unlawful for any person without
the written consent of the Architect
or authors of said documents, to
PROPOSED AFFINITEA SHOP MR. PATRICK MUSNI SITE DEVELOPMENT PLAN
PLUMBING NOTES
P - 01
JAN. 07, 2019 MISCELLANEOUS DETAILS
duplicate or copy said documents. Bus Bay, SM City Pampanga, San Fernando,
[RA 545 Sec. 25 (4)] Pampanga

Вам также может понравиться