Вы находитесь на странице: 1из 11

Mould Prevention knowledge

Production CFS DC / Call out

Future Plan
TAIEASY INTERNATIONAL CO., LTD
Process control of Mould Problem

Fabric
moisture Keep cleaning in Good Condition to
measuring work shop store the goods

Keep clean
Garment measures Dry room & set
warehouse &
moisture before up dehumidified
carton put on
pack machine
pallet

TAIEASY INTERNATIONAL CO., LTD


• Keep Dry and Clean
• Make sure workshop, warehouse are well ventilated if possible keep
humidity below 50%
• Keep the exhaust fan open and well air ventilation.
• Monitor the temperature and humidity at the fabric warehouse

TAIEASY INTERNATIONAL CO., LTD


• Keep Dry and Clean
• Make sure workshop, warehouse are well ventilated if possible keep humidity
below 50%
• Monitor the temperature and humidity at the sewing line.

TAIEASY INTERNATIONAL CO., LTD


• Never Allow to clean the
warehouse with wet mops.
• Arrange properly the garments
during stacking at warehouse
• Keep the exhaust fan open.
• Well air Ventilation
• Monitor the temperature and
humidity at the store
garments.

TAIEASY INTERNATIONAL CO., LTD


• Never Allow to clean the
warehouse with wet mops.
• Keep warehouse door
closed in rainy days.
• Keep the exhaust fan open.
• Well air Ventilation
• Cartons must be put on the
pallets and away from wall.
• Monitor the temperature
with record.

TAIEASY INTERNATIONAL CO., LTD


Requirement moisture index
Standard
Types Of Fabric Remarks
Humidity
Wool 24
Cotton 67
Viscose 55
Linen / Flax 77
Nylon 67
Polyester 39
Silk 35
Acrylic 40

TAIEASY INTERNATIONAL CO., LTD


Moisture Standard for blend composition
For Example
60cotton/40polyester
Base on requirement moisture index
of cotton is 67 and polyester is 39

67X60%+39X40%=40.2+15.6=55.8

TAIEASY INTERNATIONAL CO., LTD


Temperature and Humidity Daily monitoring
TAIEASY INTERNATIONAL CO., LTD
Temperature and Humidity Monitoring
NOTE: Acceptable temperature 32 degree Standard, 33 degree at risk and 35 degrees immediate precaution.

Temperature Actual Humidity Actual Not Checked


Date Time Accepted Remarks
required Temperature required Humidity Accepted by

TAIEASY INTERNATIONAL CO., LTD


Question for Dry room
• Humidity Standard
• Temperature Standard
• Size of the dry room each HP dry machine
• How to arrange the garments? In hanger rack or troley Tray
• What exactly time for in/out at dry room
• Fabrication requirements for Humidity/temperature
• Standard for moisture index

TAIEASY INTERNATIONAL CO., LTD


TAIEASY INTERNATIONAL CO., LTD

Вам также может понравиться