Sepam series 10
Digital protection relays
Catalogue
2012
Sepam series 10 Contents
Introduction 3
Sepam protection relays, the product of experience 3
Presentation 7
Presentation of Sepam series 10 7
Applications 8
Sepam 10 series applications 8
Connection 12
Operating diagram 12
Connection to Sepam series 10 15
Characteristics 16
Protection functions 16
Measurements 17
Electrical characteristics 18
Environmental characteristics 19
Dimensions 21
User-machine interface and dimensions 21
Sensors 22
Core balance CTs CSH120, CSH200, GO110 22
Power supply 23
PS100 High-availability power supply 23
Ordering information 25
Sepam series 10 25
1
2
Introduction Sepam protection relays,
the product of experience
Protection relays constantly monitor the power network and trip the circuit breakers
to isolate the faulty portion under fault conditions: overload, short-circuit, insulation
fault.
The Sepam range of protection relays is designed for all protection applications in
medium-voltage public and industrial distribution networks.
It is made up of four series of relays with increasing performance levels:
Sepam series 10 for simple applications.
Sepam series 20 for current or voltage applications.
Sepam series 40 for current and voltage applications.
Sepam series 60 for demanding applications.
Sepam series 80 for critical or custom applications.
You can be sure of finding the range of products meeting your needs and complying
perfectly with local standards.
Our technicians are always on hand to provide solutions tailored to your needs and
all the technical assistance you may require.
3
Selection guide for all Selection guide for all applications
applications
series 10 series 20
Protections
Current b b b b b
Voltage b b
Frequency b b
phase and phase and earth fault breaker disconnection
Specifics earth fault earth fault overcurrent failure by rate of
overcurrent overcurrent change of
frequency
Applications
Substation A B N S20 S24
Motor M20
Generator
Capacitor
Characteristics
Logic inputs/ Inputs 4 0 0 0 to 10 0 to 10
outputs Outputs 7 3 3 4 to 8 4 to 8
Temperature sensors 0 to 8 0 to 8
Current 3I + Io 3I + Io Io 3I + Io
Channel Voltage 3V + Vo
LPCT (1) Yes
Communication ports 1 1 to 2 1 to 2
IEC61850 Protocol Yes Yes
Redudancy
Goose message
Matrix (2) Yes Yes
Control Logic equation editor
Logipam (3)
Backup Lithium battery (4)
Other Front Memory cartridge
with settings
(1) LPCT: low-power current transducer complying with standard IEC 60044-8.
(2) Control matrix for simple assignment of information from the protection, control and monitoring functions.
(3) Logipam ladder language (PC programming environment) to make full use of Sepam series 80 functions.
(4) Standard lithium battery 1/2 AA format 3.6 V front face exchangeable.
4
Selection guide for all Selection guide for all applications
applications
series 40 series 60
Protections
Current b b b b b b b b
Voltage b b b b b b b
Frequency b b b b b b b
directional directional directional directional directional
Specifics earth fault earth fault and earth fault earth fault earth fault and
phase phase
overcurrent overcurrent
Applications
Substation S40 S41 S42 S43 S44 S60 S62
(5) (5) (5) (5) (5)
S50 S51 S52 S53 S54
Busbar
Transformer T40 T42 T60 T62
(6) (6)
T50 T52
Capacitor C60
Characteristics
Logic inputs/ Inputs 0 to 10 0 to 28
outputs Outputs 4 to 8 4 to 16
Temperature sensors 0 to 16 0 to 16
Current 3I + Io 3I + Io
Channel Voltage 3V, 2U + Vo 3V, 2U + Vo or Vnt
LPCT (1) Yes Yes
Communication ports 1 to 2 1 to 2
IEC61850 Protocol Yes Yes
Redudancy Yes Yes
Goose message Yes
Matrix (2) Yes Yes
Control Logic equation editor Yes Yes
Logipam (3)
Backup 48 hours Lithium battery(4)
Other Front Memory cartridge
Yes
with settings
(1) LPCT: low-power current transducer complying with standard IEC 60044-8.
(2) Control matrix for simple assignment of information from the protection, control and monitoring functions.
(3) Logipam ladder language (PC programming environment) to make full use of Sepam series 80 functions.
(4) Standard lithium battery 1/2 AA format 3.6 V front face exchangeable.
5
Selection guide for all Selection guide for all applications
applications
series 80
b b b b b b b b
b b b b b b b b
b b b b b b b b
directional directional disconnection transformer & machine voltage and frenquency capacitor-bank unbalance
earth fault earth fault and by rate of transformer- differential protection for 2 sets of
phase change of machine unit busbars
overcurrent frequency differential
B80 B83
C86
0 to 42 0 to 42 0 to 42 0 to 42
5 to 23 5 to 23 5 to 23 5 to 23
0 to 16 0 to 16 0 to 16 0 to 16
3I + 2 x Io 2 x 3I + 2 x Io 3I + Io 2 x 3I + 2 x Io
3V + Vo 3V + Vo 2 x 3V + 2 x Vo 3V + Vo
Yes Yes Yes Yes
2 to 4 2 to 4 2 to 4 2 to 4
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Lithium battery(4) Lithium battery(4) Lithium battery(4) Lithium battery(4)
Yes Yes Yes Yes
(5) S5X applications are identical to S4X applications with the following additional functions:
b earth fault and phase overcurrent cold load pick-up,
b broken wire detection,
b fault locator.
(6) T5X applications are identical to T4X applications with the following additional functions:
b earth fault and phase overcurrent cold load pick-up
b broken wire detection.
6
Presentation Presentation of Sepam series 10
Sepam series 10 is a high-quality protection relay that represents the most cost-
PB103446_SE
7
Applications Sepam series 10 applications
Protection applications
The primary applications for Sepam series 10 are:
protection of secondary distribution networks (MV/MV and MV/LV substations)
protection of buildings supplied with medium voltage (MV), including office
buildings, shopping centres, industrial buildings, warehouses, etc.
protection of low-voltage networks by tripping a Masterpact NW circuit breaker not
equipped with a Micrologic control unit.
Main HV / MV Secondary
Main HV / MV substation
substation substation
8
Functions Protection functions
Sepam series 10
t
DE53228
9
Functions Protection and measurement
Sepam series 10 functions
N B A External tripping
A Sepam series 10 A can receive, via a logic input, a tripping order from an external
protection device.
N B A Earth-fault current
This function displays the value of the fundamental of the earth-fault current.
For this measurement and for earth-fault protection (ANSI 50N/51N), the zero-
sequence input must be connected either to the common point of the three phase
CTs or to one earth-fault protection CT or to a CSH120, CSH200 or GO110 core
balance CT.
N B A Phase currents
This function displays the rms phase-current values and takes into account
harmonics up to order 13. On Sepam series 10•4••, this function displays the three
phase currents. On Sepam series 10•3••, only the A and C phases are connected
and displayed.
10
Functions Control and monitoring
Sepam series 10
Trip Closing Sepam can be used in all types of circuit-breaker control systems.
orders orders
Functions of the output relays
Relay outputs Standard assignment
O1 Circuit-breaker tripping
A 10
Closing inhibit
9 (ANSI86)
O2 Closing inhibited
O2 8
7 O3 Tripping indication
6
5
4
Trip-circuit supervision
O1
3 N B A
This function continuously monitors the trip circuit to make sure that it has not been
interrupted. The system shown opposite runs a low current through the trip circuit.
Sepam checks that the current is effectively present.
Displays the characteristics of the last fault. Sepam indicates the fault source, the
D 18
Trip
orders
Closing
orders value of the three phase currents and the earth current at the time of tripping.
O4 17
The information is stored in memory until the next fault.
Origin of recorded faults : I>, I>>, Io>, Io>> and thermal overload protection.
A 10
Closing inhibit
9
(ANSI86)
O2 8
7
6
5
N B A Record of last five events
O1 4
3
Displays the characteristics of the last five events. For each event, Sepam indicates
the fault source, the value of the three phase currents and the earth current at the
time of the event and the date and time of the event.
D 5 The events are numbered in order of occurrence and the last five are memorized.
I2 4
2
Recorded events:
I1 1 tripping due to I>, I>>, I>>>,Io>, Io>>, thermal overload protection
tripping via input signal from external device
fault in tripping circuit
circuit-breaker opening and closing initiated by communication
tripping due to I>, I>>, Io> or Io>> (logic discrimination back-up)
Shunt trip unit Closing coil
N B A Operating language
On delivery, the default language is English. The languages that may be selected are
UK English, US English, French, German, Italian, Portuguese, Spanish and Turkish.
11
Connection Operating diagram
N B A Sepam series 10 N
IA
DE53186
IB
IC
A 14
B 13
15
O3 12
25 11
14
24
13
23 10
9
Io > S O2 8
7
Io I > R
12 2-240 A
1 S 1
22
R
CSH120 11 6
CSH200 21 Io >> 5
GO110 O1 4
Io 3
0.2-24 A 2
Reset 1
A A
DE53184
DE53185
B B
C C
B B
15 15
25 25
14 14
24 24
13 13
23 23
12 12
CT
22 Io 1A/5A 22 Io
11 11
21 21
Customization via
Relay outputs Standard assignment
parameter settings
O1 Circuit breaker tripping YES
O2 Circuit breaker lockout YES
O3 Tripping indication YES
12
Connection Operating diagram
N B A Sepam series 10 B
IA
DE53189
IB
IC
I> A 14
B I> 13
15 IA
O3 12
25 max 1 S 11
14 IB R
24
13 IC I >>
23 10
9
49 RMS S O2 8
R 7
S 1
R
6
5
Io > O1 4
Io I > 3
2-240 A 2
12 1 S 1
22
R
11
21 Io >>
Io
0.2-24 A
Reset
A A
DE53188
DE53187_SE
B B
C C
15 B 15 B
25 IA 25 IA max
14 14
24 IB 24
13 13
23 IC 23 IC
Io
12 12 2-240 A
CT 22
1A/5A Io 22
11 CSH120 11
21 Io
CSH200 21 0.2 - 24 A
GO110
Customization via
Relay outputs Standard assignment
parameter settings
O1 Circuit breaker tripping YES
O2 Circuit breaker lockout YES
O3 Tripping indication YES
13
Connection Operating diagram
N B A Sepam series 10 A
IA
DE53192
IB
IC
I> A 14
B IA I> 13
15
max O3 12
25 1 S 11
14 IB R
24
13 IC
I >>
23 10
9
49 RMS S O2 8
R 7
S 1
R
6
5
Io > 1 O1 4
3
I > 2
12 Io
1 S 1
22
R
11
21 Io >>
9
D Ext
I4
8 S
Local / remote
Reset
R
7
External I3 1
6
tripping
C RS 485
1 C
COM
2 S
3 D0
D 18
4 D1
O4 17
68
16
D O5 15
5
Circuit breaker I2
4
closed 14
3 O6 13
2
TCS
Circuit I1 Watchdog
1 12
breaker open 11
O7
10
A A
DE53191
DE53190_SE
B B
C C
15 B 15 B
25 IA 25 IA
14 14
24 IB 24 IB
13 13
23 IC 23 IC
Io
12 12 2 - 240 A
CT 22
1A/5A Io 22
11 CSH120 11
21 Io
CSH200 21 0.2-24 A
GO110
Customization via
Logic inputs Standard assignment
parameter settings
I1 Circuit breaker open NO
I2 Circuit breaker closed NO
I3 External tripping YES
I4 Local / remote YES
Customization via
Relay outputs Standard assignment
parameter settings
O1 Circuit breaker tripping YES
O2 Circuit breaker lockout YES
O3 Tripping indication YES
O4 Circuit breaker closing by remote control NO
O5 Blocking send YES
O6 Indication of trip circuit fault (TCS) YES
O7 Watchdog NO
14
Connection Connection to Sepam series 10
DE53230
12 O3
11
7-8 and 9-10 Logic output O2
10
9
8 O2
11-12 and Logic output O3
7 13-14
6
5
4 O1
3
2
1
14
for standard and sensitive earth-fault protection
B 24 IB
13 for high sensitivity earth-fault protection (rating
Sepam series 10 N and 10 B. 23 IC
2...240 A)
12
22 Io
2-240 A 11-21 Input for earth-fault current Io, only for high
11
21
Io sensitivity earth-fault protection (rating 0.2..24 A)
0.2-24 A
C 2 Shielding
C S D0 D1
1 2 3 4 3 D0 communication - negative polarity (A)
4 D1 communication - positive polarity (B)
Wiring
Identification Type of terminal Wiring
B Screw, 4 mm (0.16 in) 1…6 mm2 (AWG 18…10) - 2 lugs maximum
Screw clamp, 3 mm 1 wire: 0,2...2.5 mm² (AWG 24...12)
A , C et D
(0,12 in) 2 wires: 0.2...1 mm² (AWG 24...18)
Screw, 4 mm (0,16 in) 6 mm² green/yellow wire (AWG 10)
15
Characteristics Protection functions
1000
Tripping curve
DT: Definite time
SIT/A: IEC standard inverse
VIT/B: IEC very inverse
LTI/B: IEC long-time inverse
EIT/C: IEC extremely inverse
100 MI/D: IEEE moderately inverse
VI/E: IEEE very inverse
EI/F: IEEE extremely inverse
RI
I>, I>>, I>> set points
10 DT curve 0.1...24 In (minimum: 1 A)
LTI/B IDMT curves 0.1...2,4 In (minimum: 1 A)
Accuracy ±5 % or ±0.02 In
RI Drop out/pick up ratio 95 %
SIT/A
Transient overshoot < 10 %
1
Io>, Io>> set points
VIT/B DT curve Standard version Setting range: 0.1…24 Ino
(minimum: 1 A)
Sensitive version Setting range: 0.01…2.4 Ino
(minimum: 0.1 A)
EIT/C
High sensitivity Rating 0.2…24 A Setting range: 0.0004…0.05 Ino
0.1 version (Ino = 470 A)
1 2 5 10 20 I/I>/I>> Rating 2.0…240 A Setting range: 0.004…0.5 Ino
or (Ino = 470 A)
Io/Io>
IDMT curves Standard version Setting range: 0.2…2.4 Ino
IEC curves SI, VI, LTI, EI and RI curve. (minimum: 1 A)
Sensitive version Setting range: 0.01…0.24 Ino
(minimum: 0.1 A)
Sec
DE53194
16
Characteristics Measurements
17
Characteristics Electrical characteristics
18
Characteristics Environmental characteristics
Power frequency for status inputs IEC 60255-22-7 - 300 V CM (1) ; 150 V DM (2)
IEC 61000-4-16 4
Safety
Safety tests
General IEC 60255-27 - -
Dielectric withstand at power frequency IEC 60255-5 - 2 kV 1 mn: logic input/outputs and supply,
IEC 60255-27 RS485 port
ANSI C37.90 - 1.5 kV ; 1 mn between open contacts
Surges 1.2/50 µs IEC 60255-5 5 kV for logic inputs and outputs
IEC 60255-27 3 kV for RS485 port
Insulation resistance IEC 60255-27 - 500 V CM (1) and DM (2)
R > 100 MWB ; R > 10 MWA
19
Characteristics Environmental characteristics
Mechanical robustness
In operation
Vibrations IEC 60255-21-1 2 1 Gn; 10...150 Hz; 1 cycle
Shocks IEC 60255-21-2 2 10 Gn for 11 ms
Earthquakes IEC 60255-21-3 2 2 Gn horizontal, 1 Gn vertical
De-energized
Vibrations IEC 60255-21-1 2 2 Gn; 10...150 Hz; 20 cycles
Shocks IEC 60255-21-2 2 30 Gn for 11 ms
Bumps IEC 60255-21-2 2 20 Gn for 16 ms
Enclosure protection
Front panel IEC 60529 IP54 -
NEMA 250 Type 12 -
Rear panel IEC 60529 IP40 -
Shocks IEC 62262 IK7 2 Joules
Fire resistance IEC 60695-2-11 - 650 °C
20
Dimensions User-machine interface and
dimensions
User-machine interface
1 Back-lit display
DE53450_SE
2 Status LEDs
3 Fault LEDs
4 Button for Sepam reset and maximeter reset
5 Battery housing (Sepam series 10 A)
6 Protection cover for settings
7 Identification zone
8 Lead-seal accessory
9 Button for setting selection and confirmation
10 Buttons for selection in a menu
11 Button to cancel entry
12 Buttons for setting adjustments
13 Button for menu selection and LED test
14 Menu pictograms
15 Cursor for menu selection
Dimensions
DE53451_SE
21
Sensors Core balance CTs
CSH120, CSH200, GO110
Function
The specifically designed CSH120 and CSH200 core balance CTs are used for direct
residual current measurement. The only difference between them is the diameter.
PE50032
Due to their low voltage insulation, they may be used only on cables with earthed
shielding.
Characteristics
CSH120 CSH200 GO110
Inner diameter 120 mm (4.7 in) 200 mm (7.9 in) 110 mm (4.33 in)
Weight 0.6 kg (1.32 lb) 1.4 kg (3.09 lb) 3.2 kg (7.05 Ilb)
Accuracy ±5 % à 20 °C (68 °F) < 0,5 % (10...250 A)
±6 % max. from -25 °C to 70 °C < 1,5 % (10...250 A)
Core balance CTs CSH120 and CSH200. (-13 °F to +158 °F)
Transformation ratio 1/470
Maximum permissible current 20 kA - 1 s
Operating temperature -25 °C to +70 °C (-13 °Fto +158 °F)
Storage temperature -40 °C to +85 °C (-40 °F to +185 °F)
DE53446
Dimensions A B D E F H J K L
CSH120 mm 120 164 44 190 76 40 166 62 35
in 4.72 6.46 1.73 7.48 2.99 1.57 6.54 2.44 1.38
CSH200 mm 200 256 46 274 120 60 257 104 37
in 7.87 10.1 1.81 10.8 4.72 2.36 10.1 4.09 1.46
GO110 mm 110 110 72 148 - 57 - - -
in 4.33 4.33 2.83 5.83 2.24
22
Power supply PS100 High-availability
power supply
substations
Applications
The power supply unit supplies backup operating power for:
MV switchgear motor mechanisms and circuit breaker coils
Transmission equipment (e.g. radio)
Control units such as RTU or Automatic Transfer System
Protection relays, Fault Passage Indicators and others electronic devices
High availability power supply
A battery ensures uninterrupted operation of the whole substation in the event of
loss of the main supply. The backup power supply unit:
Includes a regulated and temperature-compensated charger
Stops the battery before deep discharge
Carries out a battery check every 12 hours
Backup solution for MV switchgear power needs in Measures battery ageing
the event of micro outages and power interruptions. Forwards monitoring information via a Modbus communication port and output
Easy maintenance with only one battery relays
Battery remote monitoring
High level of insulation to protect the electronic PS100 benefits
devices in harsh MV environments Only one battery
Compliant with standards IEC 60 255-5 (10kV level) Traditional backup power supplies require a set of 2 or 4 batteries to produce 24V
or 48V, with complicated replacement and adjustment of the battery pack. The
PS100 needs only one battery, simplifying replacement. The battery is a standard
sealed lead-acid 12V battery with a 10-year service. It can be purchased easily,
anywhere in the world.
Improved availability of MV/LV substations
The PS100 is designed to ride through power network interruptions of up to 48
hours. It is associated with a battery selected to meet the required backup time.
+
For example, a 38Ah battery provides 12 hours of backup power supply to a SM6
switchboard including 4 Sepam units.
The PS100 protects and optimises the battery with state-of-the-art monitoring.
Battery PS100 A Modbus communication port forwards monitoring data to allow optimised
maintenance operations. Perfect integration with the Easergy range to control and
monitor your distribution network.
The PS100 stops supplying power and reserves an “additional Energy backup” to
PM102301
Main features
DIN rail mounting for easy integration in any LV cabinet or MV/LV substation.
2 power supply outputs:
- 12Vdc - 18W permanent / 100W 20s (for modem, radio, RTU,etc.)
- 48Vdc or 24 Vdc - 300W /1 minute (for switchgear operating mechanism
motors) and 90W / permanent for protection relays, electronic devices, etc.
RJ45 Modbus communication port
2 output relays (AC supply ON, Battery ON)
Diagnostic with LEDs
1 sealed lead-acid 12V battery with a 10-year service life (from 7Ah to 40Ah)
Power supply paralleling available with a 2nd PS100 to increase availability or to
provide additional power
-40°C to +70°C operating temperature
Dimensions : 125 x 165 x 160 mm (H x W x D mm)
References
PS100-24V EMS58580 Back-up Power supply
12V, 24V output
PS100-48V EMS58581 Back-up Power supply
12V, 48V output
Bat24AH EMS58582 Long life battery
12V - 24A.h
Bat38AH EMS58583 Long life battery
12V - 38A.h
23
Power supply PS100 High-availability
power supply
24
Ordering information Sepam series 10
Catalogue numbers
Sepam series 10
Type Cat. no Quantity
Sepam series 10 N 11 A REL59817
Sepam series 10 N 11 E REL59819
Sepam series 10 N 13 A REL59818
Sepam series 10 N 13 E REL59820
Sepam series 10 B 31 A REL59800
Sepam series 10 B 31 E REL59801
Sepam series 10 B 41 A REL59802
Sepam series 10 B 41 E REL59805
Sepam series 10 B 42 A REL59803
Sepam series 10 B 42 E REL59806
Sepam series 10 B 43 A REL59804
Sepam series 10 B 43 E REL59807
Sepam series 10 A 41 A REL59808
Sepam series 10 A 41 E REL59811
Sepam series 10 A 41 F REL59814
Sepam series 10 A 42 A REL59809
Sepam series 10 A 42 E REL59812
Sepam series 10 A 42 F REL59815
Sepam series 10 A 43 A REL59810
Sepam series 10 A 43 E REL59813
Sepam series 10 A 43 F REL59816
Replacement parts
Type Cat. no Quantity
CCA 680 set of spare connectors REL59798
Core balance CTs
Type Cat. no Quantity
Split core balance CTs, dia. 110 mm GO110 50134
Core balance CTs, dia. 120 CSH120 59635
Core balance CTs, dia. 200 CSH200 59636
Model
Earth-fault protection N
Phase-overcurrent and earth-fault protection B
Phase-overcurrent and earth-fault protection,
A
logic inputs and communication port
Supply voltage
24…125 V DC and 100…120 V AC A
110…250 V DC and 100…240 V AC E
220…250 V DC and high-threshold logic inputs F
(1) Uses 1 A/5 A sensors.
(2) Uses CSH CTs.
25