1 Objective:
To determine the volume flow rate of 2-stage air compressor
2 Equipment:
2 stage air compressor unit
Orifices meter
Temperature scale
Bourdon tube pressure gauge
3 Theory:
The Volume flow rate is the volume of fluid which passes per unit time .An orifice meter
is a device used for measuring flow rate, for reducing pressure or for restricting flow. Either
a volumetric or mass flow rate may be determined, depending on the calculation associated
with the orifice plate. As shown in figure .
𝟐𝜹𝑷 𝑨𝟐
𝑽̇ = 𝑪𝒅 √ ×
𝝆𝒂𝒊𝒓 𝟐
√𝟏 − (𝑨𝟐 )
𝑨 𝟏
𝑷 = 𝛒𝐠𝐡
Where
𝑽̇=volume flow rate of the fluid
𝑪𝒅 =coefficient of discharge = 𝟎. 𝟔𝟓
𝜹𝑷= differential pressure at discharge
𝒌𝒈
𝝆=density of fluid at inside manometer = 826 𝒎𝟑
𝒎
g=gravitational acceleration = 9.81 𝐬𝐞𝐜𝟐
𝒌𝒈
𝝆𝒂𝒊𝒓 =Density of air = 1.225 𝒎𝟑
𝑨𝟏 = Area of larger orifice
𝑨𝟐 =Area of smaller orifice
4 Prove :
We know that
𝑣 ′ = 𝐴1 𝑉1 = 𝐴2 𝑉2
𝑉′
𝑉1 = Equation no 2
𝐴1
𝑉′
𝑉2 = Equation no 3
𝐴2
Put Eq .2 andEq. 3 in Eq.1
2 2
1 𝑣′ 1 𝑣′
𝑝1 − 𝑝2 = 𝜌 ( ) − 𝜌 ( )
2 𝐴2 2 𝐴1
2 2
1 𝑣′ 𝑣′
= 𝜌 (( ) − ( ) )
2 𝐴2 𝐴1
2 2
𝑝1 − 𝑝2 𝑣′ 𝑣′
2 =( ) −( )
𝜌 𝐴2 𝐴1
𝐴2 2𝛿𝑝
𝑣′ = ∗√
2 𝜌𝑎𝑖𝑟
√1 − (𝐴2 )
𝐴1
𝐶𝑑 = 𝑐𝑜𝑒𝑓𝑓𝑖𝑐𝑖𝑒𝑛𝑡 𝑜𝑓 𝑑𝑖𝑠𝑐ℎ𝑎𝑟𝑔𝑒
5 Experimental Procedure:
Connect an electric supply to the compressor unit.
Start the compressor by switching the button on panel.
Open the discharge air valve to maintain pressure in the intake tank.
Record the motor speed and compressor speed
Fix no of revolution per minute and after 5 bar stop supplying pressure.
Record the readings of pressures after stage 1 and stage 2 in the intake and discharge.
Record the temperatures of ambient air, after stage 1, after stage 2, in the air receiver and
after the air receiver discharge valve.
Adjust the pressure in the air receiver and again record the above data.
Repeat experiment to record at least 3 readings
6 Safety precautions:
Protective gloves must be used if handling toxic materials or where there is a high
temperature present.
Always use ear muffs while working in noisy place.
Safety goggles should always be used when there is a risk to the eyes
Don’t drink water near any electrical instrument so that to prevent short circuit.
7 Table of Readings:
10 Applications: