Loading for foundation design-0m above ground(Exterior)

Acceptance Criteria
Allowable elastic lateral deflection at the top of the post 76mm
Allowable elastic deflection at the ground level of the post 25mm
Allowable vertical movement of the posts 10mm
Allowable differential vertical movement between the posts 25mm

Load Cases
Post load (Motor post) 0m above ground
Uplift DownforceLateral Moment
DL+0.6Wus 5.549 X -4.055 26.2302 kN
0.6DL+0.6Wus 6.164 X -4.076 25.4969 kN
DL+0.6Wdp X -6.975 4.054 14.5192 kN
0.6DL+0.6Wus 6.164 X -4.076 25.4969 kN
Maximum 6.164 -6.975 -4.076 26.2302 kN

Post load (Simple post-Inner Post) 0m above ground


Uplift DownforceLateral Moment
DL+0.6Wds x -12.124 11.412 19.062 kN
DL+0.6Wds x -12.124 11.412 19.062 kN
DL+0.6Wds -12.124 11.412 19.062 kN
0.6DL+0.6Wus 12.612 X -10.77 -17.9891 kN
Maximum 12.612 -12.124 11.412 19.062 kN

Post load (Simple post-Edge Post) 0m above ground


Uplift DownforceLateral Moment
DL+0.6Wds x -12.124 11.412 19.062 kN
DL+0.6Wds x -12.124 11.412 19.062 kN
DL+0.6Wds -12.124 11.412 19.062 kN
0.6DL+0.6Wus 12.612 X -10.77 -17.9891 kN
Maximum 12.612 -12.124 11.412 19.062 kN

Maximum post height


Height the lateral load is applied 0 mm
Height the lateral deflection is measured 0 mm