HGF Non-Sparking 185 kW 6P 315C/D/E 3Ph 3300 V 50 Hz IC411


- TEFC - B3R(E)
Product: 13046906

The HGF motors can be adapted to many different applications, and are available even in the Non-
Sparking version (protection type Ex nA). Able to operate in explosive atmospheres like Zone 2, Group II,
Temperature Class T3, HGF motors ensure the safety of applications on the Oil & Gas, Paper & Cellulose,
Sugar & Ethanol industries, among others.

Product features

Standard IEC 60034-1

Frequency 50 Hz

Voltage 3300 V

Number of poles 6

Degree of Protection IP55

Synchronous speed 1000 rpm

Output rating 185 kW

Mounting Foot-mounted

Flange Without

Mounting B3R(E)

Terminal box¹ Right position

Enclosure IC411 - TEFC

https://www.weg.net/catalog/weg/SE/en/Electric-Motors/IEC-Hazardous-Area-Motors/Non-Sparking-Motors/Low-Voltage-Non-Sparking-Motors/H… 1/7
4/10/2019 HGF Non-Sparking 185 kW 6P 315C/D/E 3Ph 3300 V 50 Hz IC411 - TEFC - B3R(E) | HGF - Non-Sparking Ex nA | Low Voltage Non…

   

PRODUCT DETAILS
Technical Data

Electric Motors

Frame 315C/D/E

Output 185 kW

Number of Poles 6

Frequency 50 Hz

Rated speed 983 rpm

Slip 1.70 %

Rated voltage 3300 V

Rated current 41.5 A

L. R. Amperes 257 A

LRC 6.2

No load current 17.3 A

Rated torque 183 kgfm

Locked rotor torque 150 %

Breakdown torque 229 %

Locked rotor time 21s (cold) 12s (hot)

Moment of inertia (J) 10.8 kgm²

Insulation Class F

Service factor 1.00

Temperature rise 80 K

Duty Cycle S1

Starting Method Direct On Line

https://www.weg.net/catalog/weg/SE/en/Electric-Motors/IEC-Hazardous-Area-Motors/Non-Sparking-Motors/Low-Voltage-Non-Sparking-Motors/H… 2/7
4/10/2019 HGF Non-Sparking 185 kW 6P 315C/D/E 3Ph 3300 V 50 Hz IC411 - TEFC - B3R(E) | HGF - Non-Sparking Ex nA | Low Voltage Non…

Ambient temperature -20°C to +40°C


   
Altitude 1000 m.a.s.l.

Degree of Protection IP55

Enclosure IC411 - TEFC

Mounting B3R(E)

Rotation¹ Both (CW and CCW)

Noise level² 68.0 dB(A)

Approx. weight³ 1970 kg


(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to
be changed after manufacturing process.; (4) At 100% of full load.

E ciency

50% 75% 100%

93.3  93.7  93.9 

Power factor

50% 75% 100%

0.69  0.79  0.83 

Features

Frame Material Cast Iron 

Impregnation Method Vacuum Pressure


Impregnation (VPI) 

Regreasing System At Drive end and Non-drive


end 

Space Heater Voltage 200 - 240 V 

Main terminal box hole M63x1,5 

Terminal Block HGF Connection Pins 

Accessories Terminal Box With 

Shaft Locking Device With 

Drain Rubber, automatic 

https://www.weg.net/catalog/weg/SE/en/Electric-Motors/IEC-Hazardous-Area-Motors/Non-Sparking-Motors/Low-Voltage-Non-Sparking-Motors/H… 3/7
4/10/2019 HGF Non-Sparking 185 kW 6P 315C/D/E 3Ph 3300 V 50 Hz IC411 - TEFC - B3R(E) | HGF - Non-Sparking Ex nA | Low Voltage Non…

Shaft Material SAE 4140 Carbon Steel 

Painting
 
 -
RAL 5009 214P (ISO 12944 
C4) 

Grounding Lugs Double 

Fan Cover material Cast Iron 

Tropicalized Painting Without 

Fan material Aluminum 

Bearing cap Yes- Bearing Cap 

Winding thermal protection PT100 - 3 wires 2 per phase  

Bearing thermal protection PT100 - 3 wires 1 on DE


bearing 
PT100 - 3 wires 1 on NDE
bearing 

Balancing Method 1/2 Key 

Drip Cover Without 

ABOUT THIS PRODUCT

https://www.weg.net/catalog/weg/SE/en/Electric-Motors/IEC-Hazardous-Area-Motors/Non-Sparking-Motors/Low-Voltage-Non-Sparking-Motors/H… 4/7
4/10/2019 HGF Non-Sparking 185 kW 6P 315C/D/E 3Ph 3300 V 50 Hz IC411 - TEFC - B3R(E) | HGF - Non-Sparking Ex nA | Low Voltage Non…

   

Ventilation System
The cooling system offers lower noise levels, with reductions of up to 7 dB(A), in addition to the higher
mechanical strength and optimal air ow.

Frame
The motor frame consist of a single piece of high strength cast iron. External and internal ns, in
conjunction with the fan and fan cover, provide the maximum heat dissipation avoiding the overheating of
the motor.

https://www.weg.net/catalog/weg/SE/en/Electric-Motors/IEC-Hazardous-Area-Motors/Non-Sparking-Motors/Low-Voltage-Non-Sparking-Motors/H… 5/7
4/10/2019 HGF Non-Sparking 185 kW 6P 315C/D/E 3Ph 3300 V 50 Hz IC411 - TEFC - B3R(E) | HGF - Non-Sparking Ex nA | Low Voltage Non…

   

Endshields
The endshields are built with cast iron (up to frame 400), further increasing the strength and reliability of the
whole.

Terminal Box
Through its oversized dimensions and versatility, the motors will offer easy connection, and can be supplied
according to the customer’s preference, with ying leads, terminal pins or screws (for high voltage motors),
etc. Terminal boxes can be rotated in 90°.

https://www.weg.net/catalog/weg/SE/en/Electric-Motors/IEC-Hazardous-Area-Motors/Non-Sparking-Motors/Low-Voltage-Non-Sparking-Motors/H… 6/7
4/10/2019 HGF Non-Sparking 185 kW 6P 315C/D/E 3Ph 3300 V 50 Hz IC411 - TEFC - B3R(E) | HGF - Non-Sparking Ex nA | Low Voltage Non…

   

Sleeve Bearings
Motors may be tted with sleeve bearings as an optional feature in direct coupling applications. Sleeve
bearings require less maintenance due to the fact that the lubrication intervals are up to three times longer
than the lubrication intervals of conventional bearings.

WEG SCANDINAVIA AB

Box 27, 435 21 Mölnlycke Visit: Designvägen 5, 435 33 Mölnlycke Göteborg - Västra Götaland County / Sweden

Phone: +46 31 888000

Fax: +46 31 170264

Email: info-se@weg.net

  

Privacy Policy | Cookie Statement | Terms and Conditions | RSS | © 2019 WEG. All rights reserved.

https://www.weg.net/catalog/weg/SE/en/Electric-Motors/IEC-Hazardous-Area-Motors/Non-Sparking-Motors/Low-Voltage-Non-Sparking-Motors/H… 7/7

Вам также может понравиться