Вы находитесь на странице: 1из 5

U N I V E R S A L

®
MAX FLOW SIZES FROM MAX LIQUID PRESSURE 300 PSI (20.69 BAR) SN SERIES
0.5 TO 10 GPM (2 TO 40 LPM) MAX LIQUID PRESSURE 500 PSI (34.48 BAR) SM SERIES
MAX LIQUID PRESSURE 2000 PSI (137.93 BAR) SH SERIES
F L O W M O N I T O R S

27

UNIVERSAL ®

Flow Meters
A Small Vane Style
For Liquids

®
CSA Certified NRTL/C
NRTL/C

CE Marked (as noted)

NIST Traceable Calibration SN Series shown with


Certificate Available “A” style control box

oils, paint, some corrosives,


DESCRIPTION solvents, and air and gases. Meter
bodies are available in aluminum,
These variable-area flow meters anodized aluminum, brass, cast-
have a spring-loaded swinging iron, or nickel-plated cast-iron,
vane. Mounting is in-line and in naval bronze, carbon steel, or F
any position. Straight pipe runs nickel-plated carbon steel, and 316 C
before or after the meter are not stainless steel. Aluminum, brass,
required. The all-mechanical and naval bronze are also avail- A D
sensing system directly drives B G
able with optional nylon orifice
the pointer and remote signaling cover. We offer internal moving
devices. They handle shocks or parts in the following materials: 300 E
flow surges beyond their rated series stainless steel, 316 stainless
capacities. steel, titanium, monel, and tanta-
lum. Choices of materials for seals
are: Buna N, EPR, Viton, and
CALIBRATION Kalrez, and Teflon (Kalrez can be
Fluid enters at A, passes
combined with the others). Please
All flow meters are individually around the semi-circular
consult the factory for compatibility
calibrated for fluids with the vane B. exits at outlet C.
of materials with your application.
viscosity you specify (up to 3000 The vane resists the flow
For air or gas units see the because of the spring D.
SSU/650 centipoise). We also AIR and GAS FLOW METER
compensate for your fluid’s The further the vane is
SELECTION GUIDE, page 91. pushed the larger the
specific gravity. For NIST Trace-
ability please consult factory. passageway E becomes.
This minimizes the pres-
sure drop. The vane
LINE CONNECTION
CONSTRUCTION MATERIALS shaft turns to operate the
pointer F and remote
Ports can be NPT (1/4 to 3/4"),
The meter body, internal moving signal devices such as
flanged (1/4 to 1"), or SAE straight-
parts, and seals are offered in a the switch G.
thread (1/4 to 5/8"). Metric threads
variety of materials to suit a wide such as BSPP, BSPT, JIS, etc. are
range of applications: water, available. (Flanged connections
synthetic, and petroleum based are available.)
27
DIMENSIONS (approximate) in inches

With STANDARD PLASTIC control box (symbol A)


(VALVE IS OPTIONAL
With TAMPER-PROOF enclosure (option T)
3-1/2
ONLY ON SERIES SN,
SWING ALWAYS ON OUTLET SIDE)
RADIUS
5
5-7/8 4-13/16
ELECTRICAL
CONNECTION
4-3/8 3/4 NPT
3-3/8
SWING
RADIUS 5
6-1/4(SN/SM) 5-5/8
4-5/8 7-1/4(SH)
6-1/8(SN/SM) 3-1/4
6
7-1/4(SH)
With 150 lb R.F. flanges
With STANDARD METAL control box (symbol M) (for other flanges consult factory)
Port
10-1/4
Size A (262)
3-3/8 (inches)
4-1/4
1/2 3-1/2
MULTI-PIN PC
3/4 3-7/8
SWING OPT. POSITION 1 4-1/4
RADIUS
MULTI-PIN PC
4-7/16 5-5/8
3-7/8
CONNECTOR "Flow up" or "flow down" dimensions are the same.
6-1/8(SN/SM)
Scale numbers are turned 90° to be right reading. For
7-1/4(SH) additional information on flanged connection see 129.

With HIGH-RESOLUTION control box (symbol R, RP, RT, RTV or RTZ)

MOUNTING BRACKETS
(9/32-inch mounting holes)
7-5/8

WALL MOUNTING
BRACKET

5-9/16 SWING
RADIUS 1-7/8
7-1/8(SN/SM) 9
8-1/4(SH) 8-3/4
1-3/16

With TRANSMITTER control box (symbol TP, TT, TTV, TTL, TTZ or X)

2-5/16

4-1/4

SWING
RADIUS
7-1/8
6-3/8
7-7/8(SN/SM)
8 FOOT MOUNTING
8-15/16(SH) BRACKET

With HAZARDOUS LOCATION control box (symbol X)


8 (SH)
9-3/4 8-1/2* *Width with
7-3/16 (SN/SM) PROX. second switch
5-3/8 SWITCH (9-1/4 with
prox. switch)

3-5/8
6-7/8

9
1-1/2

3/4

SWING
RADIUS 7-3/8
28
ENGINEERING DATA SPECIAL OPTIONS

Maximum fluid temperature: High temperature: (option HT) cates adequate flow. Requires
200°F (95°C) requires all-metal construction of switch and switch setpoint.
housing/orifice cover with seals of
Optional max. fluid temperatures: CE marked switches: (option CE)
Viton, EPR, Kalrez or Teflon (compat-
300 & 400°F (150 & 205°C) (option HT) SPDT 3-wire switch for general
ible with fluid). A thermal barrier (heat-
purpose use. Standard on switches
resistant cloth) is added between the
Maximum ambient temp: 150°F (65°C) 1, 1B, 2 and 2B, optional on 3, 4, 61,
housing and the control box, and
CSA listed only to 105°F (40°C) 62, 71 and 72.
must be used with service option "W"
Series SN max. operating pressure: (weatherproof) or "X" (corrosion Tempered-glass window:
(3:1 safety factor): 300 PSI (20.69 BAR) resistant). A metal scale is provided. (option TG) replaces the standard
window. A tempered-glass window
Series SM max. operating pressure: High accuracy: (option HA) modifica- is employed where airborne solvents
tion of full scale to ±3%. Not available or high-ambient temperatures are
(2:1 safety factor): 500 PSI (34.48 BAR)
with transmitter. common.
Series SH max. operating pressure: Identification tag: (option ST) Transmitter-calibrated potentio-
(3:1 safety factor), customer-supplied information is meter: (option TC) the voltage
Iron and steel housings: stamped on a stainless steel tag that signal from the potentiometer is
2000 PSI (137.93 BAR) is attached to the nameplate. recorded and filed at the factory for
Stainless steel housings: Multi-pin connector: (option PC) future reference. When a remote
1200 PSI (82.76 BAR) the male half of a Brad-Harrison type transmitter is ordered, the data
multi-pin connector, is pre-wired to recorded is used for calibration
Readout accuracy, full scale: ±5% without requiring that the flow
switch(es), potentiometer or transmitter
(opt. ±3%, see special option HA) for quick and easy field installation. meter be returned to the factory.
Maximum current for multi-pin connec- Clearance vane: (option Z86)
tors is 7 amps. Refer to Available the swing vane is modified to pro-
FLOW & PRESSURE DROP Output Types for additional ordering vide extra clearance for liquids that
information, page 124. contain particulate. Available for
Fault light: (option FL) a red LED in maximum flow range of 5 TO 9
These units impose a pressure drop GPM. This reduces the turndown.
that increases over rated flow range nameplate indicates when a flow limit
has been reached by internal switch The minimum flow is 1.5 GPM.
from 1.9 to 2.5 psi (2.2 average).
contact. Helpful with multiple meters. Tamperproof kit: (option T)
Add to end of symbol: 1 (1 light), prevents unauthorized changes to
2 (2 lights), A (AC), D (DC), i.e. FL2D. switch settings. Kit consists of a
Only available with service option "W" separate sheet-metal and plexiglass
INSTALLATION weatherproof enclosures or "X" enclosure, anchored to the flow
corrosive service. Requires switch monitor body, blocking access to
Flow monitors mount in-line and are option and switch setpoint. For the switch cam(s).
optional LED colors, consult factory.
typically supported by rigid pipe. For Remote Transmitter Calibration:
additional support when using tubing Red/green fault scale: (option RG) (option RX) coordinates specific
or flexible hose, order special options No increments are shown on scale. meter with its matching remote
W (wall) or F (foot) mounting brackets. The red portion of the scale indicates transmitter (ordered separately)
(Not available on SM and SH series). inadequate flow. Green portion indi- for proper factory calibration.

lb
WEIGHT (approximate)
(Kg)
Material of Box A Box M Box R Box T Box X
construction SN SM SH SN SM SH SN SM SH SN SM SH SN SM SH
Aluminum 2.5 2.5 - 3.2 3.2 - 4.5 4.5 - 4.4 4.4 - 5.2 5.2 -
(1.1) (1.1) - (1.4) (1.4) - (2.0) (2.0) - (2.0) (2.0) - (2.3) (2.3) -
Aluminum, nylon bowl 2.3 - - 2.8 - - 4.3 - - 4.2 - - 5 - -
(1.0) - - (1.3) - - (1.9) - - (1.9) - - (2.2) - -
Brass 5.3 5.3 - 5.8 5.8 - 7.6 7.6 - 7.5 7.5 - 8.3 8.3 -
(2.4) (2.4) - (2.6) (2.6) - (3.4) (3.4) - (3.4) (3.4) - (3.7) (3.7) -
Brass, nylon bowl 4.1 - - 4.6 - - 6.4 - - 6.3 - - 7.1 - -
(1.8) - - (2.1) - - (2.9) - - (2.8) - - (3.2) - -
Cast iron 4.9 4.9 5.2 5.4 5.4 6.7 7.2 7.2 8.5 7.1 7.1 8.4 7.9 7.9 9.2
(2.2) (2.2) (2.8) (2.4) (2.4) (3.0) (3.2) (3.2) (3.8) (3.2) (3.2) (3.8) (3.6) (3.6) (4.1)
Carbon steel 4.9 4.9 6.2 5.4 5.4 6.7 7.2 7.2 8.5 7.1 7.1 8.4 7.9 7.9 9.2
(2.2) (2.2) (2.8) (2.4) (2.4) (3.0) (3.2) (3.2) (3.8) (3.2) (3.2) (3.8) (3.6) (3.6) (4.1)
Naval bronze 5.3 5.3 - 5.8 5.8 - 7.6 7.6 - 7.5 7.5 - 8.3 7.5 -
(2.4) (2.4) - (2.6) (2.6) - (3.4) (3.4) - (3.4) (3.4) - (3.7) (3.4) -
Naval bronze, nylon bowl 4.1 - - 4.6 - - 6.4 - - 6.3 - - 7.1 - -
(1.8) - - (2.1) - - (2.9) - - (2.8) - - (3.2) - -
Stainless steel 4.9 4.9 6.2 5.4 5.4 6.7 7.2 7.2 8.5 7.1 7.1 8.4 7.9 7.9 9.2
(2.2) (2.2) (2.8) (2.4) (2.4) (3.0) (3.2) (3.2) (3.8) (3.2) (3.2) (3.8) (3.6) (3.6) (4.1)

29
HOW TO ORDER Select appropriate symbols and build a model code number, as in example shown:

EXAMPLE: SN- A S B 7 GM V - 6 - 320V.9 - A 1 N R - ST - 2D


SERIES
Small vane style
Normal pressure (300 PSI) = SN
Medium pressure (500 PSI) = SM
High press. (2000 PSI) = SH
(SM & SH not avail. with nylon bowl)

HOUSING MATERIAL (Series SN & SM)


Aluminum =D
Aluminum, nylon bowl = A*
Aluminum (hard coated) =E
Brass =F
Brass, nylon bowl = B*
Cast iron =C
Cast iron, nickel plated =N FLUID CHARACTERISTICS
Carbon steel =M Viscosity number followed by a ‘V’ (for SSU),
Carbon steel, nickel plated =J ‘C’ (for centipoise), or 'CS' (for centistokes) plus
Naval bronze =U the fluid specific gravity. (32V1.0 would mean
Naval bronze, nylon bowl = W* water.) For dual viscosity give two numbers
Stainless steel (316) = I separated by a slash (example: 320/500V1.0)
*Available only on Series SN
PORT SIZE
HOUSING MATERIAL (Series SH) NPT Flange SAE St.-Thd. Pipe Size Max
Cast iron =C Symbol Symbol Symbol Inches MM gpm
Cast iron, nickel plated =N 2 2F 4T 1/4 6.350 8
Carbon steel =M 3 3F 6T 3/8 9.525 8
Carbon steel, nickel plated =J 4 4F 8T 1/2 12.70 10
Stainless steel (316) - - 10T 5/8 15.87 10
rated to 1200 PSIG liquid =I 6 6F - 3/4 19.05 10
- 8F - 1 25.40 10
Note: Metric threads such as BSPP, BSPT,
INTERNAL MOVING PARTS JIS, etc. are available, consult factory
Stainless steel (300 series & 416) =S Note: Units with flanges measure 10-1/4 inches
Stainless steel (316) = I
face to face. (Refer to page 129 for
Titanium (N/A in SH) =T additional flange information)
Monel (N/A in SH) =L
Tantalum (N/A in SH) =R
VALVE (FLOW CONTROL) Series SN only
No Symbol = No Valve
V = Valve (brass) SN bodies only on models
SEAL MATERIAL to 7 GPM (25 LPM)
Buna N =B Not available on carbon steel or stainless steel housings.
EPR =E
Viton =F
Kalrez =J SCALE CALIBRATIONS
Kalrez (dynamic) and Teflon (static) GH = Calibrated in gallons per hour
(all-metal units only) =T GM = Calibrated in gallons per minute
Kalrez (dynamic) and Buna N (static) =A LM = Calibrated in liters per minute
Kalrez (dynamic) and EPR (static) =H GLM = Dual scales (GPM and LPM)
Kalrez (dynamic) and Viton (static) =K DGM = Dual viscosity on GPM scale
DLM = Dual viscosity on LPM scale
CMH = Cubic meters per hour
IGM = Calibrated in imperial gallons per minute
For specific calibrated increments and other scales
consult factory

MAX FLOW RATING


Minimum Gallons Per Minute GPM CMH
Minimum Liters Per Minute LPM Viscosity Calibrations Reading Reading
Viscosity Calibration Reading (SSU) Increments Min - Max Min - Max
(SSU) Increments Min - Max Round Box Other Boxes
Round Box Other Boxes 500 .025 .05 .1 - 0.5 .025 - .1
500 .10 .25 .5 - 2 250 .05 .125 .25 - 1 .025 - .25
250 .20 .5 1 - 4 100 .05 .25 .5 - 1.5 .05 - .4
100 .25 .5 1 - 6 100 .10 .25 .5 - 2 .1 - 1
100 .25 1 2 - 8 32 .10 .5 .5 - 3 .25 - 2
32 .5 1 2 - 10 32 .20 .5 .5 - 4 .5 - 2.5 Consult factory
32 1 2 2 - 20 32 .25 .5 .5 - 5 for compatibility
32 1 2.5 5 - 25 32 .25 .5 1 - 6 of construction
32 1 2.5 5 - 30 32 .25 .5 1 - 7 Consult materials with the
32 1 5 5 - 35 32 .25 1 1 - 8 factory for fluid involved.
32 2 5 10 - 40 32 .25 1 1 - 9 increments
32 .5 1 2 - 10

Note: Custom scales are available in any units and increments on special order

30
INITIAL SWITCH SETTING
No symbol = Lowest possible
Or, give setting(s) in GPM or LPM. Also a symbol
to indicate that accuracy is desired during increasing
flow (U) or decreasing flow (D). (2D would mean
that switch should actuate when flow rate decreases
to 2 GPM.) Settings are field adjustable.

Simple Flow High Resolution Visual Indication of Flow Rate


Rate Indication Visual Indication of with Transmitted Output
with Optional Flow Rate with Optional
Switching Transmitted Output

fe

s
Sa
s

he
ca n Sw V hes

he
w al
CONTROL BOX & READOUT

O tiom ut 4- itch ual

itc
l S igit
In T na wi witc l

& te es l

y
at m pt te l S sua

itc
n it ch ua

l
4- ion ter t 0 m s
t

Sw
l
ith n d O afe Sw Vis
pu

ca
e

na D
tio sm it is
A

a i
Give one symbol each for box (1),

4- & nsm tion h V

i
In n & ns s Out
ith

io h

is

n
Po itt lly- nal ith

pt it
ze

tio
r
di ra l th
w

O rw

t
p it
sm ca tio r w

In
readout (2), service (3),

tio ra he d

O w
Si

ca
pt e pu 2
s

pt A T s ut

In A T itc put
ca T itc te
he

er
Vo ica ans es
an si Op itte

& er
/O m he tp

Lo
x

e A io r
um

di ge w it
flow direction (4), and all Bo

itt
ow m Sw ut
itc

In lta l S sm
W 20 itc Ou

n itt
h
m

R 20 O it

sm

us
Fl 20 al O
im

In lta tio m
Sw
tic

Vo iona ran

S
4- Sw ter
special options (5), in that order

do
in

an
as

al

ar
l e

n a

Tr
d r
Pl

na m

tio Tr
Po ion
x

az
e
Bo

io tio

A
rd

ca e
pt

H
m
Tr trin

di g
pt n
da

O
al

ds
O te

w te

20
et
an

ith

ol
4-
M

H
St

1. BOXES
Choose box-type first A M R RP RT RTV RTZ TP TT TTV TTL TTZ X

2. READOUTS (switches)
0 = Scale & pointer only • • • • • • • • • • •
1 = One 3-wire SPDT, CE • • • • • • • • • •
1B = One 3-wire hi-vibrat SPDT,CE • • • • • • • • • •
2 = Two 3-wire SPDT, CE • •
2B = Two 3-wire hi-vibrat SPDT,CE • •
3 = One 4-wire SPDT • • • • • • • • • •
4 = Two 4-wire SPDT • •
61 = One high-temp. • • • • • • •
62 = Two high-temp • •
71 = One 3-wire gold contact SPDT • • • • • • • • • •
72 = Two 3-wire gold contact SPDT • •
53 = One hermetically-sealed • • • •
54 = Two hermetically-sealed • •
7 = One SPDT haz. location •
7C = One SPDT Cenelec approved •
17 = One DPDT haz. location •
17C = One DPDT Cenelec approved •
30 = One SPST haz. loc. prox. •
31 = Two SPST haz. loc. prox. •
11 = Pneumatic • •
3. SERVICE
N = Oil and dust tight (Type 12) •
W = Weatherproof (Type 4) • • • • • • • • • • • • •
X = Weatherproof, corr. (Type 4X)
* • • • • • • • • • • •
4. FLOW DIRECTION
R = Left to right • • • • • • • • • • • • •
L = Right to left • • • • • • • • • • • • •
U = Up • • • • • • • • • • • • •
D = Down • • • • • • • • • • • • •
5. SPECIAL OPTIONS
Multiple options allowed
HT = High-temp. *
400°F 400°F 400°F 300°F 300°F 300°F 300°F 300°F 300°F 300°F
HA = High Accuracy ( 3%) • C/F •
C/F C/F C/F C/F C/F C/F C/F C/F
ST = Stainless steel ID tag • • • • • • • • • • • •
PC = Multi-pin connector • • • • • • • • • •
FL = Fault light • •
C = CSA enclosure/PVC window • • • • • • • • • • • • •
CE = CE marked† • • •
TG = Tempered glass window • • • • • • • • • • •
V = 1-5 VDC output • •
Y = 2-10 VDC output • •
TC = Transmitter calibrated pot • •
RX = For use with remote trans. • •
RG = Red/green fault scale •
W = Wall mounting • • • • • • • • • • • • •
F = Foot mounting • • • • • • • • • • • • •
T = Tamperproof •
Z86 = Clearanced vane 5 GPM • • • • • • • • • • • • •
• †CE
Indicates availability
* Box
standard on switches
material is polysulphone Optional location available, see M box drawing
1, 1B, 2, 2B, optional on 3, 4, 61, 62, 71 and 72
C/F Consult factory

31 Form Catalog SNMH-103.01