Академический Документы
Профессиональный Документы
Культура Документы
1
SoSafe Configurable V1.6
Release Notes
You agree not to reproduce, other than for your own personal, noncommercial use, all or part of this
document on any medium whatsoever without permission of Schneider Electric, given in writing. You also
agree not to establish any hypertext links to this document or its content. Schneider Electric does not
grant any right or license for the personal and noncommercial use of the document or its content, except
for a non-exclusive license to consult it on an "as is" basis, at your own risk. All other rights are reserved.
All pertinent state, regional, and local safety regulations must be observed when installing and using this
product. For reasons of safety and to help ensure compliance with documented system data, only the
manufacturer should perform repairs to components.
When devices are used for applications with technical safety requirements, the relevant instructions must
be followed.
Failure to use Schneider Electric software or approved software with our hardware products may result in
injury, harm, or improper operating results.
Contents .......................................................................................................................... 3
Important Information ...................................................................................................... 4
Documentation ............................................................................................................ 4
Product overview ............................................................................................................. 5
Requirements .................................................................................................................. 6
Supported operating systems ...................................................................................... 6
Microsoft .NET Framework .......................................................................................... 6
PC-Hardware ............................................................................................................... 6
Required access rights ................................................................................................ 6
New features ................................................................................................................... 7
New CPU FW 3.0 ........................................................................................................ 7
New software operators ............................................................................................... 7
Monitor simulation........................................................................................................ 7
New visualization functions .......................................................................................... 7
Fixed issues .................................................................................................................... 8
Documentation
Additional documentation is included in the software package. Some of the documents are in PDF format,
and therefore require a compatible application, such as Adobe Reader™ to view them. Adobe Reader™
is not part of the SoSafe Configurable installation but can be downloaded from the website
www.adobe.com.
Further information on Schneider Electric software products can also be found under
www.schneider-electric.com.
Make sure that you received, read and understood the product manuals for the different hardware
components. Strictly follow the instructions contained in those manuals when operating the devices, and
pay particular attention to any and all safety information.
PC-Hardware
COMPONENT MINIMUM
RAM 256 MB
Free memory space on the hard drive 300 MB
Drive DVD Reader
Keyboard, mouse or compatible
Peripheral devices
pointing device.
USB port up to 3.0
Note: Upon installing this newer SoSafe Configurable version, the older one will be uninstalled
automatically
Modules with versions prior to 3.0 had the limitation of a single guard lock.
• Restart Macro: It includes a logical operator with a maximum of 7 inputs and the restart operator,
and it can also be set as manual restart.
• Timer Operator "Delay Line": When the signal IN is moved to 0 logic level, this operator inserts
a delay to a signal carrying the output OUT to 0 after the time set. If before the end of the set time
the input IN returns to 1, the output OUT still generates a pulse signal with this duration: about 3
times the response time plus the delayed time set.
• Monostable B operator: The operator MONOSTABLE supplies the “out” output with a logic level
1 (TRUE) which is triggered by the rising edge of the signal on input “In”. The logic level 1
remains for the duration of the set time.
• Flip-Flop T operator: The operator T FLIP FLOP stores the status of the Q output (Toggle).
• Reset M1 operator: This operator resets the system in case of errors detected on the inputs or
outputs. This operator generates a reset of the system when the corresponding input is double
transitioned OFF-ON-OFF in less than 5s.
• Network_In input: To improve the management of the network connection, a new Network_In
input has been added. This input must be used in case of connection between CPU OSSD output
and the input of another CPU.
Monitor simulation
The Simulator allows to verify the functionality and correct operation of a project created with the safety
designer before the assembly of the machinery. It allows to activate the inputs of the system manually or
in a programmed way to ensure that the output results obtained are correct.
Additionally, the AutoPan utility is added. The position of the project scheme on the display is
automatically adjusted depending on the location of the selected item.