Вы находитесь на странице: 1из 8

Modular Safety Controller V2.

1
SoSafe Configurable V1.6
Release Notes

Software version 1.6.1


Release date 2018-07-10
Document build 18.07.10.16.25

This document contains important information


about the SoSafe Configurable software. Please read the complete
document before you run the product.

Software component SoSafe Configurable 1.6


Document build 18.07.10.16.25 Page 1 of 8
The information provided in this documentation contains general descriptions and/or technical
characteristics of the performance of the products contained herein. This documentation is not intended
as a substitute for and is not to be used for determining suitability or reliability of these products for
specific user applications. It is the duty of any such user or integrator to perform the appropriate and
complete risk analysis, evaluation and testing of the products with respect to the relevant specific
application or use thereof. Neither Schneider Electric nor any of its affiliates or subsidiaries shall be
responsible or liable for misuse of the information contained herein. If you have any suggestions for
improvements or amendments or have found errors in this publication, please notify us.

You agree not to reproduce, other than for your own personal, noncommercial use, all or part of this
document on any medium whatsoever without permission of Schneider Electric, given in writing. You also
agree not to establish any hypertext links to this document or its content. Schneider Electric does not
grant any right or license for the personal and noncommercial use of the document or its content, except
for a non-exclusive license to consult it on an "as is" basis, at your own risk. All other rights are reserved.

All pertinent state, regional, and local safety regulations must be observed when installing and using this
product. For reasons of safety and to help ensure compliance with documented system data, only the
manufacturer should perform repairs to components.

When devices are used for applications with technical safety requirements, the relevant instructions must
be followed.

Failure to use Schneider Electric software or approved software with our hardware products may result in
injury, harm, or improper operating results.

Failure to observe this information can result in injury or equipment damage.

© 2018 Schneider Electric. All Rights Reserved.

Software component SoSafe Configurable 1.6


Document build 18.07.10.16.25 Page 2 of 8
Contents

Contents .......................................................................................................................... 3
Important Information ...................................................................................................... 4
Documentation ............................................................................................................ 4
Product overview ............................................................................................................. 5
Requirements .................................................................................................................. 6
Supported operating systems ...................................................................................... 6
Microsoft .NET Framework .......................................................................................... 6
PC-Hardware ............................................................................................................... 6
Required access rights ................................................................................................ 6
New features ................................................................................................................... 7
New CPU FW 3.0 ........................................................................................................ 7
New software operators ............................................................................................... 7
Monitor simulation........................................................................................................ 7
New visualization functions .......................................................................................... 7
Fixed issues .................................................................................................................... 8

Software component SoSafe Configurable 1.6


Document build 18.07.10.16.25 Page 3 of 8
Important Information

Documentation
Additional documentation is included in the software package. Some of the documents are in PDF format,
and therefore require a compatible application, such as Adobe Reader™ to view them. Adobe Reader™
is not part of the SoSafe Configurable installation but can be downloaded from the website
www.adobe.com.

Further information on Schneider Electric software products can also be found under
www.schneider-electric.com.

Make sure that you received, read and understood the product manuals for the different hardware
components. Strictly follow the instructions contained in those manuals when operating the devices, and
pay particular attention to any and all safety information.

Software component SoSafe Configurable 1.6


Document build 18.07.10.16.25 Page 4 of 8
Product overview
The Modular Safety Controller offer is composed of a controller with a variety of expansion modules. The
safety controller can be expanded up to 128 digital inputs, 16 solid state or relay safety outputs, and up to
28 (status) diagnostic outputs. The offer is configured by using SoSafe Configurable software.
SoSafe Configurable is used for the following tasks:
• Creating / Editing an application project (safety application)
• Compiling the project
• Sending the project to the Safety Controller
• Online Monitoring of the Safety Controller configuration
• Project documentation
• Application simulation

Software component SoSafe Configurable 1.6


Document build 18.07.10.16.25 Page 5 of 8
Requirements

Supported operating systems


This software can be installed onto the following operating systems:
• Microsoft Windows 7 32/64 Bit with latest service pack
• Microsoft Windows 8.1 32/64 Bit with latest service pack
• Microsoft Windows 10 32/64 Bit with latest service pack

Microsoft .NET Framework


SoSafe Configurable requires Microsoft .NET Framework 3.5 (or higher)

PC-Hardware
COMPONENT MINIMUM
RAM 256 MB
Free memory space on the hard drive 300 MB
Drive DVD Reader
Keyboard, mouse or compatible
Peripheral devices
pointing device.
USB port up to 3.0

Required access rights


For the execution of SoSafe Configurable, no special access rights are required.

Note: Upon installing this newer SoSafe Configurable version, the older one will be uninstalled
automatically

Software component SoSafe Configurable 1.6


Document build 18.07.10.16.25 Page 6 of 8
New features

New CPU FW 3.0


The CPU can support 2 Guard Locks on the status output in addition to those available on the OSSD,
bringing the total to three.

Modules with versions prior to 3.0 had the limitation of a single guard lock.

New software operators


• Logical Macro: Groupings can be created with a maximum of three operators of different types
for a total of max. 8 inputs.
This allows to increase the maximum number of operators used (now 64).
With the introduction of the macro you have an average increase of about 30% of the number of
operators.

• Restart Macro: It includes a logical operator with a maximum of 7 inputs and the restart operator,
and it can also be set as manual restart.

• Timer Operator "Delay Line": When the signal IN is moved to 0 logic level, this operator inserts
a delay to a signal carrying the output OUT to 0 after the time set. If before the end of the set time
the input IN returns to 1, the output OUT still generates a pulse signal with this duration: about 3
times the response time plus the delayed time set.

• Monostable B operator: The operator MONOSTABLE supplies the “out” output with a logic level
1 (TRUE) which is triggered by the rising edge of the signal on input “In”. The logic level 1
remains for the duration of the set time.

• Flip-Flop T operator: The operator T FLIP FLOP stores the status of the Q output (Toggle).

• Reset M1 operator: This operator resets the system in case of errors detected on the inputs or
outputs. This operator generates a reset of the system when the corresponding input is double
transitioned OFF-ON-OFF in less than 5s.

• Network_In input: To improve the management of the network connection, a new Network_In
input has been added. This input must be used in case of connection between CPU OSSD output
and the input of another CPU.

Monitor simulation
The Simulator allows to verify the functionality and correct operation of a project created with the safety
designer before the assembly of the machinery. It allows to activate the inputs of the system manually or
in a programmed way to ensure that the output results obtained are correct.

New visualization functions


In this release, zoom + and zoom- are available. These functions can be activated pressing the CTRL key
on the keyboard and simultaneously rotating the mouse wheel.

Additionally, the AutoPan utility is added. The position of the project scheme on the display is
automatically adjusted depending on the location of the selected item.

Software component SoSafe Configurable 1.6


Document build 18.07.10.16.25 Page 7 of 8
Fixed issues
• The "select all network" command did not operate correctly if the network starts from a single
OSSD
• If you connect OSSD StatusOut to serializer input you had an error message and the connection
was forbidden
• Short command CTRL + O and CTRL + S are now functional
• Company information is saved by default

Software component SoSafe Configurable 1.6